Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
Foods ; 12(3)2023 Jan 19.
Artigo em Inglês | MEDLINE | ID: mdl-36765990

RESUMO

Amaranth 11S globulins (Ah11Sn) are an excellent source of essential amino acids; however, there have been no investigations on the characterization of their techno-functional properties at different pH conditions and NaCl concentrations, which are necessary for food formulations. In this work, we report a new two-step purification method for native Ah11Sn with purity levels of ~95%. LC-MS/MS analysis revealed the presence of three different Ah11Sn paralogs named Ah11SB, A11SC, and Ah11SHMW, and their structures were predicted with Alphafold2. We carried out an experimental evaluation of Ah11Sn surface hydrophobicity, solubility, emulsifying properties, and assembly capacity to provide an alternative application of these proteins in food formulations. Ah11Sn showed good surface hydrophobicity, solubility, and emulsifying properties at pH values of 2 and 3. However, the emulsions became unstable at 60 min. The assembly capacity of Ah11Sn evaluated by DLS analysis showed mainly the trimeric assembly (~150-170 kDa). This information is beneficial to exploit and utilize Ah11Sn rationally in food systems.

2.
Food Chem ; 396: 133681, 2022 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-35853375

RESUMO

A microvolumetric method for surface hydrophobicity (H0) determination of proteins using a Nanodrop fluorospectrometer was developed. This method reduces the protein and fluorophore quantities that are necessary for sample preparations and readings by two and three orders of magnitude, respectively, compared to conventional methods. In addition, readings can be obtained in just 2-6 s. Bovine serum albumin (BSA) and 1-anilino 8-naphthalene sulfonic acid (ANS) were used for the first optimization of appropriate fluorophore-protein conditions for H0 determination (20 µM ANS, 0.5-4 µM BSA, pH 5). Based on validation guidelines, the novel method shows linear behavior, good intraday precision, accuracy, and sensitivity. This method was robust against several factors, as determined by a Youden-Steiner test. Additional surface hydrophobicity determinations using several proteins demonstrate suitable method applicability. The present microvolumetric method provides a reliable technique to determine the H0 of proteins for pharmaceutical, biotechnological, and food applications.


Assuntos
Corantes Fluorescentes , Soroalbumina Bovina , Naftalenossulfonato de Anilina , Interações Hidrofóbicas e Hidrofílicas , Ligação Proteica , Soroalbumina Bovina/metabolismo , Espectrometria de Fluorescência
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA