Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
1.
Magn Reson Med ; 86(3): 1194-1211, 2021 09.
Artigo em Inglês | MEDLINE | ID: mdl-33847012

RESUMO

PURPOSE: A standard MRI system phantom has been designed and fabricated to assess scanner performance, stability, comparability and assess the accuracy of quantitative relaxation time imaging. The phantom is unique in having traceability to the International System of Units, a high level of precision, and monitoring by a national metrology institute. Here, we describe the phantom design, construction, imaging protocols, and measurement of geometric distortion, resolution, slice profile, signal-to-noise ratio (SNR), proton-spin relaxation times, image uniformity and proton density. METHODS: The system phantom, designed by the International Society of Magnetic Resonance in Medicine ad hoc committee on Standards for Quantitative MR, is a 200 mm spherical structure that contains a 57-element fiducial array; two relaxation time arrays; a proton density/SNR array; resolution and slice-profile insets. Standard imaging protocols are presented, which provide rapid assessment of geometric distortion, image uniformity, T1 and T2 mapping, image resolution, slice profile, and SNR. RESULTS: Fiducial array analysis gives assessment of intrinsic geometric distortions, which can vary considerably between scanners and correction techniques. This analysis also measures scanner/coil image uniformity, spatial calibration accuracy, and local volume distortion. An advanced resolution analysis gives both scanner and protocol contributions. SNR analysis gives both temporal and spatial contributions. CONCLUSIONS: A standard system phantom is useful for characterization of scanner performance, monitoring a scanner over time, and to compare different scanners. This type of calibration structure is useful for quality assurance, benchmarking quantitative MRI protocols, and to transition MRI from a qualitative imaging technique to a precise metrology with documented accuracy and uncertainty.


Assuntos
Processamento de Imagem Assistida por Computador , Imageamento por Ressonância Magnética , Espectroscopia de Ressonância Magnética , Imagens de Fantasmas , Razão Sinal-Ruído
2.
Mil Med ; 185(Suppl 1): 50-56, 2020 01 07.
Artigo em Inglês | MEDLINE | ID: mdl-32074359

RESUMO

INTRODUCTION: There is mounting evidence of respiratory problems related to military service in the Middle East in the past two decades due to environmental exposures during deployment (eg, sand storms and burn pits). This pilot study tests the hypothesis that regional lung function in subjects with prior deployment in Iraq and/or Afghanistan with suspected War Lung Injury (WLI) would be worse than subjects with normal lung function. MATERIALS AND METHODS: Five subjects meeting the inclusion and exclusion criteria were recruited for this pilot study. All subjects underwent spirometry, high-resolution chest computed tomography imaging, and 19F MRI. RESULTS: While the WLI subjects had normal pulmonary function tests and normal high-resolution chest computed tomography evaluations, their regional lung function from 19F MRI was abnormal with compartments with poor function showing slower filling time constants for ventilation. The scans of suspected WLI subjects show higher fractional lung volume with slow filling compartments similar to patients with chronic obstructive pulmonary disease in contrast to normal subjects. CONCLUSIONS: This is consistent with our premise that WLI results in abnormal lung function and reflects small airways dysfunction and suggests that we may be able to provide a more sensitive tool for evaluation of WLI suspected cases.


Assuntos
Imagem por Ressonância Magnética de Flúor-19/métodos , Lesão Pulmonar/diagnóstico por imagem , Adulto , Campanha Afegã de 2001- , Feminino , Imagem por Ressonância Magnética de Flúor-19/instrumentação , Imagem por Ressonância Magnética de Flúor-19/estatística & dados numéricos , Humanos , Guerra do Iraque 2003-2011 , Masculino , Pessoa de Meia-Idade , Oxigenoterapia/métodos , Projetos Piloto , Sistema de Registros/estatística & dados numéricos , Inquéritos e Questionários , Estados Unidos
3.
Magn Reson Med ; 79(1): 48-61, 2018 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-29083101

RESUMO

The MRI community is using quantitative mapping techniques to complement qualitative imaging. For quantitative imaging to reach its full potential, it is necessary to analyze measurements across systems and longitudinally. Clinical use of quantitative imaging can be facilitated through adoption and use of a standard system phantom, a calibration/standard reference object, to assess the performance of an MRI machine. The International Society of Magnetic Resonance in Medicine AdHoc Committee on Standards for Quantitative Magnetic Resonance was established in February 2007 to facilitate the expansion of MRI as a mainstream modality for multi-institutional measurements, including, among other things, multicenter trials. The goal of the Standards for Quantitative Magnetic Resonance committee was to provide a framework to ensure that quantitative measures derived from MR data are comparable over time, between subjects, between sites, and between vendors. This paper, written by members of the Standards for Quantitative Magnetic Resonance committee, reviews standardization attempts and then details the need, requirements, and implementation plan for a standard system phantom for quantitative MRI. In addition, application-specific phantoms and implementation of quantitative MRI are reviewed. Magn Reson Med 79:48-61, 2018. © 2017 International Society for Magnetic Resonance in Medicine.


Assuntos
Mapeamento Encefálico/métodos , Imageamento por Ressonância Magnética/métodos , Imagens de Fantasmas , Algoritmos , Biomarcadores/metabolismo , Calibragem , Meios de Contraste/química , Elasticidade , Humanos , Processamento de Imagem Assistida por Computador , Modelos Lineares , Modelos Teóricos , Perfusão , Valores de Referência , Reprodutibilidade dos Testes , Razão Sinal-Ruído
4.
Chest ; 144(4): 1300-1310, 2013 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-23722696

RESUMO

BACKGROUND: Fluorine-enhanced MRI is a relatively inexpensive and straightforward technique that facilitates regional assessments of pulmonary ventilation. In this report, we assess its suitability through the use of perfluoropropane (PFP) in a cohort of human subjects with normal lungs and subjects with lung disease. METHODS: Twenty-eight subjects between the ages of 18 and 71 years were recruited for imaging and were classified based on spirometry findings and medical history. Imaging was carried out on a Siemens TIM Trio 3T MRI scanner using two-dimensional, gradient echo, fast low-angle shot and three-dimensional gradient echo, volumetric, interpolated, breath-hold examination sequences for proton localizers and PFP functional scans, respectively. Respiratory waveforms and physiologic signals of interest were monitored throughout the imaging sessions. A region-growing algorithm was applied to the proton localizers to define the lung field of view for analysis of the PFP scans. RESULTS: All subjects tolerated the gas mixture well with no adverse side effects. Images of healthy lungs demonstrated a homogeneous distribution of the gas with sufficient signal-to-noise ratios, while lung images from asthmatic and emphysematous lungs demonstrated increased heterogeneity and ventilation defects. CONCLUSIONS: Fluorine-enhanced MRI using a normoxic PFP gas mixture is a well-tolerated, radiation-free technique for regionally assessing pulmonary ventilation. The inherent physical characteristics and applicability of the gaseous agent within a magnetic resonance setting facilitated a clear differentiation between normal and diseased lungs.


Assuntos
Meios de Contraste , Fluorocarbonos , Pneumopatias/diagnóstico , Imageamento por Ressonância Magnética , Adolescente , Adulto , Idoso , Feminino , Humanos , Imageamento por Ressonância Magnética/métodos , Masculino , Pessoa de Meia-Idade , Adulto Jovem
5.
Arthritis Rheum ; 65(7): 1812-1821, 2013 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-23576116

RESUMO

OBJECTIVE: To evaluate subchondral bone trabecular integrity (BTI) on radiographs as a predictor of knee osteoarthritis (OA) progression. METHODS: Longitudinal (baseline, 12-month, and 24-month) knee radiographs were available for 60 female subjects with knee OA. OA progression was defined by 12- and 24-month changes in radiographic medial compartment minimal joint space width (JSW) and medial joint space area (JSA), and by medial tibial and femoral cartilage volume on magnetic resonance imaging. BTI of the medial tibial plateau was analyzed by fractal signature analysis using commercially available software. Receiver operating characteristic (ROC) curves for BTI were used to predict a 5% change in OA progression parameters. RESULTS: Individual terms (linear and quadratic) of baseline BTI of vertical trabeculae predicted knee OA progression based on 12- and 24-month changes in JSA (P < 0.01 for 24 months), 24-month change in tibial (P < 0.05), but not femoral, cartilage volume, and 24-month change in JSW (P = 0.05). ROC curves using both terms of baseline BTI predicted a 5% change in the following OA progression parameters over 24 months with high accuracy, as reflected by the area under the curve measures: JSW 81%, JSA 85%, tibial cartilage volume 75%, and femoral cartilage volume 85%. Change in BTI was also significantly associated (P < 0.05) with concurrent change in JSA over 12 and 24 months and with change in tibial cartilage volume over 24 months. CONCLUSION: BTI predicts structural OA progression as determined by radiographic and MRI outcomes. BTI may therefore be worthy of study as an outcome measure for OA studies and clinical trials.


Assuntos
Cartilagem Articular/diagnóstico por imagem , Fêmur/diagnóstico por imagem , Osteoartrite do Joelho/diagnóstico , Tíbia/diagnóstico por imagem , Idoso , Cartilagem Articular/patologia , Estudos de Coortes , Progressão da Doença , Feminino , Fêmur/patologia , Fractais , Humanos , Processamento de Imagem Assistida por Computador , Estudos Longitudinais , Imageamento por Ressonância Magnética , Pessoa de Meia-Idade , Curva ROC , Radiografia , Tíbia/patologia
6.
Arthritis Rheum ; 60(12): 3711-22, 2009 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-19950282

RESUMO

OBJECTIVE: To evaluate the effectiveness of using subchondral bone texture observed on a radiograph taken at baseline to predict progression of knee osteoarthritis (OA) over a 3-year period. METHODS: A total of 138 participants in the Prediction of Osteoarthritis Progression study were evaluated at baseline and after 3 years. Fractal signature analysis (FSA) of the medial subchondral tibial plateau was performed on fixed flexion radiographs of 248 nonreplaced knees, using a commercially available software tool. OA progression was defined as a change in joint space narrowing (JSN) or osteophyte formation of 1 grade according to a standardized knee atlas. Statistical analysis of fractal signatures was performed using a new model based on correlating the overall shape of a fractal dimension curve with radius. RESULTS: Fractal signature of the medial tibial plateau at baseline was predictive of medial knee JSN progression (area under the curve [AUC] 0.75, of a receiver operating characteristic curve) but was not predictive of osteophyte formation or progression of JSN in the lateral compartment. Traditional covariates (age, sex, body mass index, knee pain), general bone mineral content, and joint space width at baseline were no more effective than random variables for predicting OA progression (AUC 0.52-0.58). The predictive model with maximum effectiveness combined fractal signature at baseline, knee alignment, traditional covariates, and bone mineral content (AUC 0.79). CONCLUSION: We identified a prognostic marker of OA that is readily extracted from a plain radiograph using FSA. Although the method needs to be validated in a second cohort, our results indicate that the global shape approach to analyzing these data is a potentially efficient means of identifying individuals at risk of knee OA progression.


Assuntos
Processamento de Imagem Assistida por Computador/métodos , Articulação do Joelho/patologia , Osteoartrite do Joelho/diagnóstico por imagem , Tíbia/diagnóstico por imagem , Fatores Etários , Progressão da Doença , Feminino , Fractais , Humanos , Articulação do Joelho/fisiopatologia , Masculino , Osteoartrite do Joelho/patologia , Osteoartrite do Joelho/fisiopatologia , Osteófito/patologia , Valor Preditivo dos Testes , Curva ROC , Radiografia , Tíbia/patologia , Tíbia/fisiopatologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA