Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 98
Filtrar
1.
Heliyon ; 10(9): e30500, 2024 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-38765069

RESUMO

Bacterial antimicrobial resistance (BAMR) seems to pose the greatest threat to public health, food safety, and agriculture in this century. The development of novel efficient antimicrobial agents to combat bacterial infections has become a global issue. Silver nanoparticles (Ag NPs) appeared as a feasible alternative to antibiotics. However, Ag NPs face cost, toxicity, and aggregation issues which limit their antibacterial activity. This work aims to stabilize Ag NPs with enhanced antimicrobial activity at comparatively lower Ag concentrations to prevent bacterial infections. For this purpose, the Ag core was covered with nanodiamonds (NDs). Ag-NDs composite have been synthesized by microplasma technique. TEM analysis confirmed the presence of both Ag and NDs in the Ag-NDs composite. A particle size (∼19 nm) was reported for Ag-NDs at the highest concentration as compared to Ag NPs (∼3 nm). The conduction band of the diamond acted as an extremely strong reducing agent for Ag NPs. The large surface area of NDs stabilized the Ag NPs. A redshift (∼400 nm-406 nm) in UV-visible spectra of the Ag-NDs composite indicated the formation of bigger-sized Ag NPs after incorporating NDs. XRD and LIBS analysis verified the increase in intensity of Ag-NPs by increasing ND concentration. The presence of functional groups including OH, CH, and Ag/Ag2O was confirmed by FTIR. Bacterial inhibition growth appeared to be a dose-dependent process. The minimum inhibition concentration value of Ag-NDs composite at the highest NDs concentration against E. coli (∼ 0.69 µg/ml) and S. aureus (∼44 µg/ml). This is the first study to report the smallest MIC for E. coli (<1 µg/ml). Ag-ND composites emerged to be more efficient than Ag NPs and preferred to be used against BAMR. The enhanced antibacterial activity of the Ag-NDs composite makes it a potential candidate for antibiotics, food products, and pesticides.

2.
Artigo em Inglês | MEDLINE | ID: mdl-38767741

RESUMO

Green nanotechnology is one of the most expanding fields that provides numerous novel nanoparticle drug formulations with enhanced bioactivity performance. This study aims to synthesize mesoporous metal organic framework (ZIF-8) phytofabricated with the herb Allium sativum (As) as an indicator system for its antibacterial and antifungal impact. The successful synthesis of ZIF-8 as nanocomposite was characterized by X-ray diffraction (XRD), Fourier transform infrared spectroscopy (FT-IR), and scanning coupled with energy-dispersive X-ray spectroscopy and transmission electron microscopy (SEM-EDX and TEM) that showed the textural retainment of ZIF-8 on composite formation with A. sativum. The nanocomposite, A. sativum extract, and ZIF-8 were subjected to antimicrobial assays against Shigella flexneri, Candida albicans, and Candida parapsilosis. The comparative results indicated the potential action of nanocomposite against the bacteria and both the Candida sps; however, the antifungal action against the Candida sps was more effective than the bacterium S. flexneri. The findings suggest that plants, being an important component of ecosystems, could be further explored for the novel drug discovery using green nanotechnology to enhance their impact on the drug-resistant pathogens.

3.
Int J Mol Sci ; 25(6)2024 Mar 09.
Artigo em Inglês | MEDLINE | ID: mdl-38542131

RESUMO

A chemo-drug such as cisplatin is effective for cancer treatment but remains non-specific, is susceptible to drug resistance, and induces several side effects on organ systems. Zeolitic imidazolate framework-8, a type of MOF, has gained attention, including as a drug delivery method for targeted cancer therapeutics. In this study, ZIF-8/Silica nanocomposite was synthesized using a one-pot hydrothermal technique using the Stober technique. We studied the effect of phyto-synthesized GPt and chemo-drug cisplatin CPt on ZIF-8/Silica for targeted efficacy of cancer therapy. The texture, morphology, and chemical environment of Pt on ZIF-8/Silica were analyzed using different characterization techniques such as XRD, FT-IR, BET, diffuse reflectance spectroscopy, SEM-EDX, TEM, zeta potential, and TGA analysis. The isothermal behavior of CPt and GPt adsorption was investigated using isotherm models like Langmuir, Freundlich, and Temkin isotherm. The adsorption kinetics indicating the adsorption efficiency of GPt and CPt are influenced by the concentration of Pt complex and the adsorption sites of ZIF-8/Silica. A high entrapment efficiency and loading capacity of GPt (86% and 4.3%) and CPt (91% and 4.5%) were evident on ZIF-8/Silica. The nanocomposite showed a pH-sensitive Pt release using a dialysis membrane technique. For instance, a high release of GPt (93%) was observed under pH = 6.6 in 72 h, while the release reduced to 50% at pH 7.4 in 72 h. The anti-cancer activity of nanoformulations was studied in vitro using MCF7 (breast cancer cells) and HFF-1 (human foreskin fibroblast) cells. The findings demonstrated that GPt is as effective as CPt; the EC50 value for MCF7 cells treated with ZIF-8/Silica/Cp/PEG was 94.86 µg/mL, whereas for ZIF-8/Silica/GPt/PEG it was 60.19 µg/mL.


Assuntos
Antineoplásicos , Nanocompostos , Neoplasias , Zeolitas , Humanos , Cisplatino/farmacologia , Platina , Zeolitas/química , Espectroscopia de Infravermelho com Transformada de Fourier , Dióxido de Silício/química , Antineoplásicos/farmacologia , Imidazóis/farmacologia , Imidazóis/química , Neoplasias/tratamento farmacológico
4.
Environ Sci Pollut Res Int ; 31(14): 22171-22186, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38403831

RESUMO

Root-to-shoot translocation of nanoparticles (NPs) is a matter of interest due to their possible unprecedented effects on biota. Properties of NPs, such as structure, surface charge or coating, and size, determine their uptake by cells. This study investigates the size effect of iron oxide (Fe3O4) NPs on plant uptake, translocation, and physiology. For this purpose, Fe3O4 NPs having about 10 and 100 nm in average sizes (namely NP10 and NP100) were hydroponically subjected to barley (Hordeum vulgare L.) in different doses (50, 100, and 200 mg/L) at germination (5 days) and seedling (3 weeks) stages. Results revealed that particle size does not significantly influence the seedlings' growth but improves germination. The iron content in root and leaf tissues gradually increased with increasing NP10 and NP100 concentrations, revealing their root-to-shoot translocation. This result was confirmed by vibrating sample magnetometry analysis, where the magnetic signals increased with increasing NP doses. The translocation of NPs enhanced chlorophyll and carotenoid contents, suggesting their contribution to plant pigmentation. On the other hand, catalase activity and H2O2 production were higher in NP10-treated roots compared to NP100-treated ones. Besides, confocal microscopy revealed that NP10 leads to cell membrane damages. These findings showed that Fe3O4 NPs were efficiently taken up by the roots and transported to the leaves regardless of the size factor. However, small-sized Fe3O4 NPs may be more reactive due to their size properties and may cause cell stress and membrane damage. This study may help us better understand the size effect of NPs in nanoparticle-plant interaction.


Assuntos
Hordeum , Hordeum/metabolismo , Tamanho da Partícula , Bioacumulação , Peróxido de Hidrogênio/metabolismo , Plântula , Nanopartículas Magnéticas de Óxido de Ferro
5.
J Prosthodont ; 2024 Feb 15.
Artigo em Inglês | MEDLINE | ID: mdl-38357722

RESUMO

PURPOSE: The aim of this study was to investigate and compare the influence of zirconium dioxide nanoparticles (ZrO2 NPs) and silicon dioxide nanoparticles (SiO2 NPs) addition and printing orientation on the flexural strength (FS) of provisional three-dimensional (3D) printing resins undergoing thermal cycling (TC). METHODS: Three dimensional-printed resin (NextDent C&B MFH) was used to fabricate 300 bar-shaped specimens (25 × 2 × 2 mm3 ). The ZrO2 NPs and SiO2 NPs specimens were divided into two groups, then subdivided into three groups, based on the nanoparticle concentration (i.e., 0 wt% (original group), 0.5 wt%, and 1 wt%). Each concentration was printed in three printing orientations (0°, 45°, and 90°). The printed specimens were exposed to 5000 cycles of TC, followed by a three-point bending test to assess the FS. Fracture surface analysis was conducted by using a scanning electron microscope (SEM). For data analysis, ANOVA and Tukey's post hoc were utilized (α = 0.05). RESULTS: Compared to the original material, the addition of ZrO2 NPs and SiO2 NPs had a significantly positive impact on the FS, (P > 0.001). After TC, the FS of the original group decreased significantly and had the lowest value. The highest FS value was observed in 1% ZrO2 NPs at 0°. Regardless of the nanoparticle concentration, the 0° orientation consistently showed a higher FS, compared to the 45° and 90° orientations. At all orientations (i.e., 0°, 45°, and 90°), the FS significantly increased with the addition of NPs, compared with that of the original material (P > 0.001). TC had a significantly negative effect on the FS of the unmodified groups. However, no significant differences existed in FS among the modified groups after TC. CONCLUSION: The addition of SiO2 NPs and ZrO2 NPs increased the FS of the 3D-printed provisional resin. Regardless of the nanoparticle concentration, the 0° orientation had the higher FS. TC had an effect on the original resin, whereas it had no significant effect on the nanoparticle-modified resins. In clinical practice, 3D-printed provisional nanocomposite resins printed at the 0° orientation could be recommended for long-term dental provisional restorations.

6.
RSC Adv ; 14(1): 160-180, 2024 Jan 02.
Artigo em Inglês | MEDLINE | ID: mdl-38173594

RESUMO

Objective: To enhance the brain bioavailability of S-allyl-l-cysteine (SC) by developing novel S-allyl-l-cysteine chitosan nanoparticles (SC CS NPs) and examining the quantity of SC by developing a novel method of ultra-high performance liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS) in ischemic rat brain treatment. Methods: The ionotropic gelation method was used to develop S-allyl cysteine-loaded CS NPs. The 4-factor, 5-level central composite design was optimized to determine the effect of independent variables, i.e., particle size, polydispersity index (PDI), zeta potential, EE, and loading capacity, together with their characterization, followed by drug release and intranasal permeation to enhance the brain bioavailability and examination of their neurobehavioral and biochemical parameters with their histopathological examination. Results: SC CS NPs were optimized at the particle size of 93.21 ± 3.31 nm (PDI: 0.317 ± 0.003), zeta potential of 44.4 ± 2.93, and drug loading of 41.23 ± 1.97% with an entrapment efficiency of 82.61 ± 4.93% having sustain and controlled release (79.92 ± 3.86%) with great permeation (>80.0%) of SC. SC showed the retention time of 1.021 min and 162.50/73.05 m/z. SC showed good linearity in the range of 5.0-1300.0 ng mL-1, % inter-and-intraday accuracy of 96.00-99.06% and CV of 4.38-4.38%. We observed significant results, i.e., p < 0.001 for improved (AUC)0-24 and Cmax delivered via i.v. and i.n. dose. We also observed the highly significantly observations of SC CS NPs (i.n.) based on their treatment results for the biochemical, neurobehavioral, and histopathological examination in the developed ischemic MCAO brain rat model. Conclusion: The excellent significant role of mucoadhesive CS NPs of SC was proven based on the enhancement in the brain bioavailability of SC via i.n. delivery in rats and easy targeting of the brain for ischemic brain treatment followed by an improvement in neuroprotection based on a very small dose of SC.

7.
Nanomaterials (Basel) ; 13(23)2023 Nov 30.
Artigo em Inglês | MEDLINE | ID: mdl-38063757

RESUMO

Three-dimensionally (3D)-printed fabricated denture bases have shown inferior strength to conventional and subtractively fabricated ones. Several factors could significantly improve the strength of 3D-printed denture base resin, including the addition of nanoparticles and post-curing factors. This study evaluated the effect of TiO2 nanoparticle (TNP) addition and the post-curing time (PCT) on the flexural properties and hardness of three-dimensionally (3D)-printed denture base resins. A total of 360 specimens were fabricated, with 180 specimens from each type of resin. For evaluating the flexural properties, bar-shaped specimens measuring 64 × 10 × 3.3 mm were used, while, for the hardness testing, disc-shaped specimens measuring 15 × 2 mm were employed. The two 3D-printed resins utilized in this study were Asiga (DentaBASE) and NextDent (Vertex Dental B.V). Each resin was modified by adding TNPs at 1% and 2% concentrations, forming two groups and an additional unmodified group. Each group was divided into three subgroups according to the PCT (15, 60, and 90 min). All the specimens were subjected to artificial aging (5000 cycles), followed by testing of the flexural strength and elastic modulus using a universal testing machine, and the hardness using the Vickers hardness test. A three-way ANOVA was used for the data analysis, and a post hoc Tukey's test was used for the pairwise comparisons (α = 0.05). Scanning electron microscopy (SEM) was used for the fracture surface analysis. The addition of the TNPs increased the flexural strength in comparison to the unmodified groups (p < 0.001), while there was no significant difference in the elastic modulus and hardness with the 1% TNP concentration. Among the TNP groups, the 2% TNP concentration significantly decreased the elastic modulus and hardness (p < 0.001). The SEM showed a homogenous distribution of the TNPs, and the more irregular fracture surface displayed ductile fractures. The PCT significantly increased the flexural strength, elastic modulus, and hardness (p < 0.001), and this increase was time-dependent. The three-way ANOVA results revealed a significant difference between the material types, TNP concentrations, and PCT interactions (p < 0.001). Both concentrations of the TNPs increased the flexural strength, while the 2% TNP concentration decreased the elastic modulus and hardness of the 3D-printed nanocomposites. The flexural strength and hardness increased as the PCT increased. The material type, TNP concentration, and PCT are important factors that affect the strength of 3D-printed nanocomposites and could improve their mechanical performance.

8.
PLoS One ; 18(11): e0294446, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-38011158

RESUMO

This study aimed to synthesize fluoride-doped bioactive glass (F-BG) based thermo-sensitive injectable hydrogel for endodontic applications. The structural and phase analyses were done with Fourier Transform Infrared spectroscopy and X-ray Diffraction, respectively. The setting time of prepared injectable was investigated at 21°C (in the presence and absence of an ultrasonic scalar) and at 37°C. Flowability was tested according to ISO-6876:2012 specifications, whereas injectability was checked by extrusion method using 21-, 22-, and 23-gauge needles. The in vitro bio-adhesion and push-out bond strength were studied on days 7 and 90 and compared with the commercially available TotalFill®. The ion release profile was analyzed for up to 30 days with Inductively Coupled Plasma Optical Emission Spectroscopy. The fluoride release analysis was conducted periodically for up to 21 days in deionized water and artificial saliva using an ion-selective electrode. The final setting time at 21°C, 21°C+ultrasonic scalar, and 37°C were 38.66±3.21, 29.12±1.23, and 32±3.46 min, respectively. The flowability was 25±3.94 mm, and the injectability coefficient was ≥70.3 for 22, 21, and 57% in a 23-gauge needle. Fluoride release in deionized water was found to be significantly higher than in artificial saliva and increased with time. A significant difference in bond strength was found between days 7 and 90, where the strength was increased, and a new apatite layer was formed on the tooth surface. A rapid release of calcium, phosphate, and silicon ions was seen initially, whereby the continuous release of these ions was observed for up to 30 days. The prepared F-BG injectable hydrogel has shown promising results and has the potential to be used as an endodontic sealer.


Assuntos
Fluoretos , Hidrogéis , Fluoretos/análise , Saliva Artificial , Cavidade Pulpar , Vidro/química , Água , Teste de Materiais
9.
J Prosthodont ; 2023 Nov 13.
Artigo em Inglês | MEDLINE | ID: mdl-37953735

RESUMO

PURPOSE: To assess the influence of denture brushing on the surface roughness, hardness, and color stability of conventional, thermoformed, and CAD-CAM denture base materials. MATERIALS AND METHODS: Seven different denture base materials were included in this study; conventional heat-polymerized acrylic resin (PMMA) served as control, polyamide, acetal, two categories of milled acrylic discs (AvaDent and IvoCad), and two categories of 3D-printed resins (NextDent and FormLabs). The specimens were constructed according to manufacturers' instructions and then subjected to simulated brushing (20,000 cycles). According to the brushing method, the specimens were split into three groups, no brushing, brushing with water, and brushing with toothpaste. Surface roughness, hardness, and color change were evaluated before and after brushing. Collected data were analyzed using ANOVA, and post-hoc Tukey's tests (α = 0.05). RESULTS: A significant difference was noted between the surface roughness of the tested materials before and after denture brushing (p < 0.05), and milled resin showed the least Ra values. Denture brushing with water significantly increased the Ra of PMMA (p = 0.004) and IvoCad (p = 0.032), while brushing using toothpaste did not show a significant increase. The brushing protocols did not alter the hardness of tested materials except that of PMMA (p = 0.001). The color stability of the tested materials showed comparable results with both brushing protocols. CONCLUSION: The tested properties showed variations between the types of denture base resins. Hardness and color stability of CAD-CAM and thermoformed denture base resins were not altered by denture brushing and showed comparable results with both brushing methods. Surface roughness was the only property that showed alteration after denture brushing.

10.
Comput Struct Biotechnol J ; 21: 4261-4276, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37701018

RESUMO

There is a global health concern associated with the emergence of the multidrug-resistant (MDR) fungus Candida auris, which has significant mortality rates. Finding innovative and distinctive anti-Candida compounds is essential for treating infections caused by MDR C. auris. A bacterial strain with anti-Candida activity was isolated and identified using 16 S rRNA gene sequencing. The whole genome was sequenced to identify biosynthesis-related gene clusters. The pathogenicity and cytotoxicity of the isolate were analyzed in Candida and HFF-1 cell lines, respectively. This study set out to show that whole-genome sequencing, cytotoxicity testing, and pathogenicity analysis combined with genome mining and comparative genomics can successfully identify biosynthesis-related gene clusters in native bacterial isolates that encode antifungal natural compounds active against Candida albicans and C. auris. The native isolate MR14M3 has the ability to inhibit C. auris (zone of inhibition 25 mm) and C. albicans (zone of inhibition 25 mm). The 16 S rRNA gene sequence of MR14M3 aligned with Bacillus amyloliquefaciens with similarity (100%). Bacillus amyloliquefaciens MR14M3 establishes bridges of intercellular nanotubes (L 258.56 ± 35.83 nm; W 25.32 ± 6.09 nm) connecting neighboring cells. Candida cell size was reduced significantly, and crushed phenotypes were observed upon treatment with the defused metabolites of B. amyloliquefaciens MR14M3. Furthermore, the pathogenicity of B. amyloliquefaciens MR14M3 on Candida cells was observed through cell membrane disruption and lysed yeast cells. The whole-genome alignment of the MR14M3 genome (3981,643 bp) using 100 genes confirmed its affiliation with Bacillus amyloliquefaciens. Genome mining analysis revealed that MR14M3-coded secondary metabolites are involved in the biosynthesis of polyketides (PKs) and nonribosomal peptide synthases (NRPSs), including 11 biosynthesis-related gene clusters with one hundred percent similarity. Highly conserved biosynthesis-related gene clusters with anti-C. albicans and anti-C. auris potentials and cytotoxic-free activity of B. amyloliquefaciens MR14M3 proposes the utilization of Bacillus amyloliquefaciens MR14M3 as a biofactory for an anti-Candida auris and anti-C. albicans compound synthesizer.

11.
Polymers (Basel) ; 15(12)2023 Jun 08.
Artigo em Inglês | MEDLINE | ID: mdl-37376260

RESUMO

This study aimed to evaluate the incorporation of zirconia/silver phosphate nanoparticles to develop experimental dental adhesives and to measure their physical and mechanical properties. The nanoparticles were synthesized by the sonication method, and the phase purity, morphological pattern, and antibacterial properties with Staphylococcus aureus and Pseudomonas aeruginosa were assessed. The silanized nanoparticles were incorporated (0, 0.15, 0.25, and 0.5 wt.%) into the photoactivated dimethacrylate resins. The degree of conversion (DC) was assessed, followed by the micro-hardness and flexural strength/modulus test. Long-term color stability was investigated. The bond strength with the dentin surface was conducted on days 1 and 30. The transmission electron microscopy and X-ray diffractogram confirmed the nano-structure and phase purity of the particles. The nanoparticles showed antibacterial activities against both strains and inhibited biofilm formation. The DC range of the experimental groups was 55-66%. The micro-hardness and flexural strength increased with the concentration of nanoparticles in the resin. The 0.5 wt.% group showed significantly high micro-hardness values, whereas a non-significant difference was observed between the experimental groups for flexural strength. The bond strength was higher on day 1 than on day 30, and a significant difference was observed between the two periods. At day 30, the 0.5 wt.% showed significantly higher values compared to other groups. Long-term color stability was observed for all the samples. The experimental adhesives showed promising results and potential to be used for clinical applications. However, further investigations such as antibacterial, penetration depth, and cytocompatibility are required.

12.
Materials (Basel) ; 16(8)2023 Apr 07.
Artigo em Inglês | MEDLINE | ID: mdl-37109785

RESUMO

Pressable ceramic restorations have been introduced and investigated, and found comparable to CAD/CAM ceramic in terms of mechanical properties; however, the effect of toothbrushing on the pressable ceramic has not been thoroughly investigated. The objective of the current study was to assess the effect of artificial toothbrushing simulation on the surface roughness, microhardness, and color stability of different ceramic materials. Three lithium disilicate-based ceramics (IPS Emax CAD [EC], IPS Emax Press [EP]; (Ivoclar Vivadent AG), and LiSi Press [LP] (GC Corp, Tokyo, Japan)) were examined. For each ceramic material, eight bar-shaped specimens were prepared and subjected to 10,000 brushing cycles. Surface roughness, microhardness, and color stability (∆E) were measured before and after brushing. Scanning electron microscopy (SEM) was used for surface profile analysis. The results were analyzed using one-way ANOVA, Tukey's post hoc test, and paired sample t-test α = 0.05. The findings revealed a non-significant decrease in the surface roughness of EC, EP, and LP groups (p > 0.05), and both LP and EP have the lowest surface roughness values (0.64 ± 0.13, 0.64 ± 0.08 µm) after brushing, respectively. Toothbrushing showed a decrease in the microhardness of the three groups: EC and LP, p < 0.001; EP, p = 0.012). EP showed the lowest hardness value after brushing (862.45 ± 273.83). No significant changes (∆E) were observed in all groups (p > 0.05); however, the EC group was found to be considerably affected by color changes, in comparison to the EC and LP groups. Toothbrushing had no effect on surface roughness and color stability of all tested materials, but it decreased the microhardness. Material type, surface treatments, and glazing of ceramic materials contributed to the surface changes in the ceramic materials, necessitating further investigations in terms of the toothbrushing effect with different glazing as variables.

13.
Materials (Basel) ; 16(8)2023 Apr 08.
Artigo em Inglês | MEDLINE | ID: mdl-37109810

RESUMO

This study evaluated the effect of ultrasonic and manual scaling using different scaler materials on the surface topography of computer-aided designing and computer-aided manufacturing (CAD/CAM) ceramic compositions. After scaling with manual and ultrasonic scalers, the surface properties of four classes of CAD/CAM ceramic discs: lithium disilicate (IPE), leucite-reinforced (IPS), advanced lithium disilicate (CT), and zirconia-reinforced lithium silicate (CD) of 1.5 mm thickness were evaluated. Surface roughness was measured before and after treatment, and scanning electron microscopy was used to evaluate the surface topography following the performed scaling procedures. Two-way ANOVA was conducted to assess the association of the ceramic material and scaling method with the surface roughness. There was a significant difference in the surface roughness between the ceramic materials subjected to different scaling methods (p < 0.001). Post-hoc analyses revealed significant differences between all groups except for IPE and IPS where no significant differences were detected between them. CD showed the highest surface roughness values, while CT showed the lowest surface roughness values for the control specimens and after exposure to different scaling methods. Moreover, the specimens subjected to ultrasonic scaling displayed the highest roughness values, while the least surface roughness was noted with the plastic scaling method.

14.
J Mech Behav Biomed Mater ; 141: 105792, 2023 05.
Artigo em Inglês | MEDLINE | ID: mdl-37001247

RESUMO

OBJECTIVE: The study aimed to evaluate and compare the surface micro-hardness, roughness, color, and morphology of enamel after Er,Cr:YSGG laser irradiation, followed by application of three types of bioactive glasses-based resin infiltrants, and the samples groups were challenged with the pH cycle. METHODOLOGY: Experimental photoactivated resin infiltrants were synthesized using dimethacrylate resins, whereby three different types of bioactive glasses (BGs), i.e., 45S5, fluoridated-BG (F-BG), and borosilicate-BG (B-BG), were incorporated into the resin system. Initially, white spot lesions were created artificially on the toosth enamel surface, then irradiated with Er,Cr:YSGG laser. Then, the resin-only and BG-based resins were infiltrated on the enamel surface. All samples were pH challenged for 14 days, and the micro-hardness, surface roughness, surface morphology, and color stability (ΔE) analyses were conducted before and after the 14 days pH challenge. RESULTS: After laser irradiation, the micro-hardness was significantly high with 45S5 group compared to resin-only (p = 0.021), F-BG (p = 0.042), and B-BG (p = 0.001) groups. After the pH challenge, the micro-hardness values for all groups were reduced significantly (p ≤ 0.05). The surface roughness was least with the resin-only group and showed a non-significant difference with F-BG (p = 0.34) and significant differences with both B-BG (p = 0.005), and 45S5 (p = 0.010) groups. After the pH cycle, the roughness of all groups was increased significantly (p ≤ 0.05), except B-BG group showed a non-significant difference (p = 0.528). The B-BG group showed significantly high ΔE between day 0 and baseline compared to resin-only (p = 0.0008), F-BG (p = 0.017), and 45S5 (p = 0.029), whereas between day 14 and baseline, the lowest ΔE value was observed for B-BG (14.2 ± 2.10) and maximum for the resin-only (20.57 ± 2.47) group. The SEM images showed pitting on the surface of all resin infiltrant groups after 14 days of pH challenge. CONCLUSION: The morphological difference was observed after the laser irradiation on the enamel surface. The differences in micro-hardness, surface roughness, and color were observed after the application of experimental resin infiltrants and significant differences were observed after the pH challenge.


Assuntos
Esmalte Dentário , Lasers , Vidro , Dureza , Resinas Sintéticas , Cor
15.
Polymers (Basel) ; 15(5)2023 Feb 26.
Artigo em Inglês | MEDLINE | ID: mdl-36904416

RESUMO

Denture care and maintenance are necessary for both denture longevity and underlying tissue health. However, the effects of disinfectants on the strength of 3D-printed denture base resins are unclear. Herein, distilled water (DW), effervescent tablet, and sodium hypochlorite (NaOCl) immersion solutions were used to investigate the flexural properties and hardness of two 3D-printed resins (NextDent and FormLabs) compared with a heat-polymerized resin. The flexural strength and elastic modulus were investigated using the three-point bending test and Vickers hardness test before (baseline) immersion and 180 days after immersion. The data were analyzed using ANOVA and Tukey's post hoc test (α = 0.05), and further verified by using electron microscopy and infrared spectroscopy. The flexural strength of all the materials decreased after solution immersion (p < 0.001). The effervescent tablet and NaOCl immersion reduced the flexural strength (p < 0.001), with the lowest values recorded with the NaOCl immersion. The elastic modulus did not significantly differ between the baseline and after the DW immersion (p > 0.05), but significantly decreased after the effervescent tablet and NaOCl immersion (p < 0.001). The hardness significantly decreased after immersion in all the solutions (p < 0.001). The immersion of the heat-polymerized and 3D-printed resins in the DW and disinfectant solutions decreased the flexural properties and hardness.

16.
Cancers (Basel) ; 15(3)2023 Jan 23.
Artigo em Inglês | MEDLINE | ID: mdl-36765654

RESUMO

In nanotherapeutics, gaining insight about the drug interaction with the pore architecture and surface functional groups of nanocarriers is crucial to aid in the development of targeted drug delivery. Manganese ferrite impregnated graphene oxide (MnFe2O4/GO) with a two-dimensional sheet and spherical silica with a three-dimensional interconnected porous structure (MnFe2O4/silica) were evaluated for cisplatin release and cytotoxic effects. Characterization studies revealed the presence of Mn2+ species with a variable spinel cubic phase and superparamagnetic effect. We used first principles calculations to study the physisorption of cisplatin on monodispersed silica and on single- and multi-layered GO. The binding energy of cisplatin on silica and single-layer GO was ~1.5 eV, while it was about double that value for the multilayer GO structure. Moreover, we treated MCF-7 (breast cancer cells) and HFF-1 (human foreskin fibroblast) with our nanocomposites and used the cell viability assay MTT. Both nanocomposites significantly reduced the cell viability. Pt4+ species of cisplatin on the spinel ferrite/silica nanocomposite had a better effect on the cytotoxic capability when compared to GO. The EC50 for MnFe2O4/silica/cisplatin and MnFe2O4/GO/cisplatin on MCF-7 was: 48.43 µg/mL and 85.36 µg/mL, respectively. The EC50 for the same conditions on HFF was: 102.92 µg/mL and 102.21 µg/mL, respectively. In addition, immunofluorescence images using c-caspase 3/7, and TEM analysis indicated that treating cells with these nanocomposites resulted in apoptosis as the major mechanism of cell death.

17.
Eur J Dent ; 17(4): 1248-1256, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-36669653

RESUMO

OBJECTIVES: With advanced technology for complete denture fabrication, there is a lack of knowledge on the mechanical behavior of three-dimensional (3D) printed teeth despite the development of complete denture fabrication technologies. This study aimed to compare different types of 3D-printed teeth in terms of wear and fracture resistance in comparison to control prefabricated denture teeth. MATERIALS AND METHODS: One prefabricated tooth was selected and fixed in a resin holder and half of the tooth remained in anatomic form, while the other half was flattened for the wear test. One from each type was scanned and then printed with different resins; Asiga (DentaTOOTH, Asiga, Alexandria 2015,NSW, Australia), FormLabs (Denture Base LP, FormLabs, Berlin, Germany), and NextDent (NextDent C&B MFH, NextDent B.V., Soesterberg, the Netherlands) according to manufacturer recommendations. A total of 60 specimens (20/resin, n = 10) were thermo cycled (5,000 cycles) and wear test samples were further subjected to cyclic loading (1,70,000 cycles) in a chewing simulator machine CS-4.2 (SD Mechatronik GmbH, Germany). The fracture strength of anatomic teeth was measured using a universal testing machine (Instron model 5965, Massachusetts, United States), while Geomagic Control X software was used to assess the amount of wear of flattened teeth. Statistical analyses were performed with one-way analysis of variance with Tukey's post hoc test at significance level of α = 0.05. RESULTS: NextDent specimens showed the greatest volume loss, whereas FormLabs specimens showed the least volume loss. Comparing NextDent specimens to FromLabs specimens, FromLabs showed statistically significantly less volume loss (p < 0.001). No other group pairs differed significantly from one another in terms of volume loss (p > 0.06). CONCLUSION: 3D-printed denture teeth showed comparable strength and wear resistance with the prefabricated denture teeth and were suitable for long-term clinical usage except for NextDent that significantly showed the lowest fracture resistance.

18.
Eur J Dent ; 17(1): 234-241, 2023 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-35820440

RESUMO

OBJECTIVES: This study aimed to evaluate the influence of different salivary pH on flexural strength, hardness, and surface roughness of computer-aided design and computer-aided manufacturing (CAD/CAM) milled and three-dimensional (3D)-printed denture base resins. METHODS: One heat-polymerized, two CAD/CAM milled (IvoCad, AvaDent), and two 3D-printed (FormLabs, NextDent) denture base resins were fabricated and divided into five groups (n = 10) according to the solutions: three groups were immersed in different salivary pH (5.7, 7.0, or 8.3), one group was immersed in distilled water (DW) as a positive control, and one group had no immersion (negative control). All immersions were performed at 37°C for 90 days. Flexural strength, hardness, and surface roughness were measured before and after immersion. Data was analyzed with analysis of variance and post hoc Tukey's test (α = 0.05). RESULTS: After immersion, all specimens had lower flexural strength values when compared with those with no immersion. Comparing the immersion groups, the highest flexural strength value (93.96 ± 3.18 MPa) was recorded with IvoCad after immersion in DW while the lowest value (60.43 ± 2.66 MPa) was recorded with NextDent after being immersed in 7.0 pH saliva. All specimens had significant decrease in hardness except IvoCad and AvaDent specimens where both presented the highest surface hardness (53.76 ± 1.60 Vickers hardness number [VHN]) after immersion in DW while NextDent showed the lowest hardness value (24.91 ± 2.13 VHN) after being immersed in 8.3 pH saliva. There was statistically significant difference between the baseline and different artificial salivary pH solutions in terms of surfaces roughness, with the highest surface roughness were found in 3D-printed resin materials. CONCLUSION: After exposure to artificial saliva with different salivary pH, the milled CAD/CAM denture base resins showed higher flexural strength, hardness, and lesser surface roughness than conventional and 3D-printed denture base resins.

19.
J Prosthodont ; 32(4): 298-308, 2023 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-35801581

RESUMO

PURPOSE: To introduce a new technique, denture base layering, for the addition of titanium dioxide nanoparticles (TiO2 NPs) to polymethylmethacrylate (PMMA) and to investigate the effects of the layering technique on Candida albicans (C. albicans) adhesion and on surface roughness, hardness, translucency, and flexural strength. MATERIALS AND METHODS: In total, 210 heat-polymerized acrylic resin specimens were prepared as discs (15 × 2 mm) for testing C. albicans adhesion (n = 70) and surface roughness, hardness, and translucency (n = 70); and as acrylic plates (65 × 10 × 2.5 mm) for testing flexural strength (n = 70). Specimens were divided into 4 groups: control (n = 30), one-layer (n = 60), double-layer (n = 60), and dotted-layer (n = 60) according to the packing and layering technique. Each group was divided according to the concentration of TiO2 NPs 1% and 2.5% (n = 10). The control group comprised one layer of unmodified resin. The one-layer group comprised one layer of a mixture of PMMA/TiO2 NPs packed conventionally. The double-layer group consisted of two different layers packed in two steps, as follows: unmodified resin first, followed by a continuous thin layer of the PMMA/TiO2 NPs mixture. Similarly, the dotted-layer group consisted of two different layers packed in two steps, as follows: unmodified resin first, followed by a thin layer of the PMMA/TiO2 NPs. However, the second mixture was added in a dotted manner. The direct culture method for C. albicans adhesion before and after ultraviolet light activation, and surface roughness, hardness, translucency, and flexural strength were measured. An analysis of variance and Tukey's post hoc test were used for data analysis (α = 0.05). RESULTS: The addition of TiO2 NPs reduced C. albicans adhesion (p < 0.001). However, no significant difference was found between both concentrations within the same group before and after ultraviolet light activation (p > 0.05), except in the 1% dotted-layer (p = 0.022). Surface roughness and hardness were not affected by the additions of different concentrations of TiO2 NPs (p = 0.905) and (p = 0.059), respectively. Translucency was significantly reduced in all the groups (p < 0.001) except in the 1% dotted-layer (p = 0.332). Flexural strength decreased as the TiO2 NPs concentration increased, with the greatest reduction in strength observed in the one-layer group (p < 0.001). CONCLUSIONS: The double and dotted layering techniques were effective in reducing C. albicans adhesion, without affecting surface roughness, hardness, or flexural strength. However, translucency was reduced in all the groups, except the 1% dotted-layer group.


Assuntos
Antifúngicos , Polimetil Metacrilato , Polimetil Metacrilato/farmacologia , Teste de Materiais , Antifúngicos/farmacologia , Propriedades de Superfície , Bases de Dentadura , Candida albicans
20.
J Prosthet Dent ; 130(2): 257-264, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-34799082

RESUMO

STATEMENT OF PROBLEM: Fractures of interim fixed restorations are a common complication. The autopolymerized polymethyl methacrylate resin materials used for interim fixed restorations have limited mechanical properties, but whether adding treated zirconium dioxide nanoparticles improves mechanical properties is unclear. PURPOSE: The purpose of this in vitro study was to evaluate the effect of treated zirconium dioxide nanoparticles on the flexural strength and elastic modulus of autopolymerized polymethyl methacrylate resin. MATERIAL AND METHODS: A split-metal mold (60×10×3.3 mm) was used to fabricate 40 autopolymerized acrylic resin specimens. The specimens were divided into 4 groups (n=10) according to zirconium dioxide nanoparticle concentration: control (unmodified resin) and zirconium dioxide nanoparticle contents of 1, 2.5, and 5 wt%. The specimens were mixed and polymerized according to the manufacturer's instructions and stored in distilled water for 48 ±2 hours at 37 °C. The flexural strength and elastic modulus were evaluated based on the 3-point bend test where data were analyzed by using 1-way analysis of variance and Tukey post hoc tests (α=.05). RESULTS: The flexural strength of the 1-wt% zirconium dioxide nanoparticle specimens was significantly higher than that of the control group (P<.001) but did not significantly increase further with the higher nanoparticle content (P>.05). Elastic modulus significantly decreased with 2.5-wt% zirconium dioxide nanoparticles (P=.019), while no significant changes were found with other test groups (P>.05). CONCLUSIONS: The addition of treated zirconium dioxide nanoparticles at low concentrations increased the flexural strength of autopolymerized polymethyl methacrylate resins used in fixed interim restorations.


Assuntos
Resistência à Flexão , Nanopartículas , Polimetil Metacrilato , Teste de Materiais , Nanopartículas/uso terapêutico , Propriedades de Superfície , Maleabilidade , Estresse Mecânico
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA