1.
Toxins (Basel) ; 13(2)2021 01 25.
Artigo em Inglês | MEDLINE | ID: mdl-33504112

RESUMO

A planar waveguide (PW) immunosensor working as a polarisation interferometer was developed for the detection of mycotoxin zearalenone (ZON). The main element of the sensor is an optical waveguide consisting of a thin silicon nitride layer between two thicker silicon dioxide layers. A combination of a narrow waveguiding core made by photolithography with an advanced optical set-up providing a coupling of circular polarised light into the PW via its slanted edge allowed the realization of a novel sensing principle by detection of the phase shift between the p- and s-components of polarised light propagating through the PW. As the p-component is sensitive to refractive index changes at the waveguide interface, molecular events between the sensor surface and the contacting sample solution can be detected. To detect ZON concentrations in the sample solution, ZON-specific antibodies were immobilised on the waveguide via an electrostatically deposited polyelectrolyte layer, and protein A was adsorbed on it. Refractive index changes on the surface due to the binding of ZON molecules to the anchored antibodies were detected in a concentration-dependent manner up to 1000 ng/mL of ZON, allowing a limit of detection of 0.01 ng/mL. Structurally unrelated mycotoxins such as aflatoxin B1 or ochratoxin A did not exert observable cross-reactivity.


Assuntos
Anticorpos/imunologia , Técnicas Biossensoriais , Fusarium/metabolismo , Imunoensaio , Interferometria , Zearalenona/análise , Especificidade de Anticorpos , Limite de Detecção , Reprodutibilidade dos Testes , Zearalenona/imunologia
2.
Anal Bioanal Chem ; 411(29): 7717-7724, 2019 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-31392435

RESUMO

This work reports on further development of an optical biosensor for the in vitro detection of mycotoxins (in particular, aflatoxin B1) using a highly sensitive planar waveguide transducer in combination with a highly specific aptamer bioreceptor. This sensor is built on a SiO2-Si3N4-SiO2 optical planar waveguide (OPW) operating as a polarization interferometer (PI), which detects a phase shift between p- and s-components of polarized light propagating through the waveguide caused by the molecular adsorption. The refractive index sensitivity (RIS) of the recently upgraded PI experimental setup has been improved and reached values of around 9600 rad per refractive index unity (RIU), the highest RIS values reported, which enables the detection of low molecular weight analytes such as mycotoxins in very low concentrations. The biosensing tests yielded remarkable results for the detection of aflatoxin B1 in a wide range of concentrations from 1 pg/mL to 1 µg/mL in direct assay with specific DNA-based aptamers. Graphical abstract Optical planar waveguide polarization interferometry biosensor for detection of aflatoxin B1 using specific aptamer.


Assuntos
Aflatoxina B1/análise , Aptâmeros de Nucleotídeos/química , Interferometria/métodos , Técnicas Biossensoriais , Técnicas In Vitro , Limite de Detecção , Ocratoxinas/análise , Óptica e Fotônica , Refratometria , Dióxido de Silício/química
3.
Toxins (Basel) ; 10(7)2018 07 03.
Artigo em Inglês | MEDLINE | ID: mdl-29970806

RESUMO

The research aim of this work is to develop a simple and highly sensitive optical biosensor for detection of mycotoxins. This sensor is built on a planar waveguide operating on the polarization interferometry principle, i.e., detecting a phase shift between p- and s-components of polarized light developed during the binding of analyte molecules. The operation of the proposed sensor is similar to that of a Mach⁻Zehnder interferometer, while its design is much simpler and it does not require splitting the waveguide into two arms. The refractive index sensitivity of the polarization interferometer sensor was in the range of 5200 radians per refractive index unit (RIU). Several tests were conducted to detect ochratoxin A (OTA) at different concentrations in direct immunoassay with specific antibodies immobilized in the sensing window. The lowest concentration of OTA of 0.01 ng/mL caused a phase shift of nearly one period. The results obtained prove high sensitivity of the sensors, which are capable of detecting even lower concentrations of mycotoxins at the ppt (part-per-trillion) level.


Assuntos
Técnicas Biossensoriais , Ocratoxinas/análise , Anticorpos Monoclonais/química , Anticorpos Monoclonais/imunologia , Proteínas Imobilizadas/química , Imunoensaio , Interferometria , Ocratoxinas/química , Ocratoxinas/imunologia , Fenômenos Ópticos , Proteína Estafilocócica A/química