RESUMO
BACKGROUND: The COVID-19 pandemic adversely affected health care systems. Patients in need of transcatheter aortic valve replacement (TAVR) are especially susceptible to treatment delays. OBJECTIVES: This study sought to evaluate the impact of the COVID-19 pandemic on global TAVR activity. METHODS: This international registry reported monthly TAVR case volume in participating institutions prior to and during the COVID-19 pandemic (January 2018 to December 2021). Hospital-level information on public vs private, urban vs rural, and TAVR volume was collected, as was country-level information on socioeconomic status, COVID-19 incidence, and governmental public health responses. RESULTS: We included 130 centers from 61 countries, including 65,980 TAVR procedures. The first and second pandemic waves were associated with a significant reduction of 15% (P < 0.001) and 7% (P < 0.001) in monthly TAVR case volume, respectively, compared with the prepandemic period. The third pandemic wave was not associated with reduced TAVR activity. A greater reduction in TAVR activity was observed in Africa (-52%; P = 0.001), Central-South America (-33%; P < 0.001), and Asia (-29%; P < 0.001). Private hospitals (P = 0.005), urban areas (P = 0.011), low-volume centers (P = 0.002), countries with lower development (P < 0.001) and economic status (P < 0.001), higher COVID-19 incidence (P < 0.001), and more stringent public health restrictions (P < 0.001) experienced a greater reduction in TAVR activity. CONCLUSIONS: TAVR procedural volume declined substantially during the first and second waves of the COVID-19 pandemic, especially in Africa, Central-South America, and Asia. National socioeconomic status, COVID-19 incidence, and public health responses were associated with treatment delays. This information should inform public health policy in case of future global health crises.
Assuntos
Estenose da Valva Aórtica , COVID-19 , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/métodos , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Pandemias , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/epidemiologia , Resultado do Tratamento , COVID-19/epidemiologia , Sistema de Registros , Fatores de RiscoRESUMO
Heart failure affects millions of patients all over the world, and its treatment is a major clinical challenge. Cardiac dyssynchrony is common among patients with advanced heart failure. Resynchronization therapy is a major advancement in heart failure management, but unfortunately not all patients respond to this therapy. Hence, many diagnostic tests have been used to predict the response and prognosis after cardiac resynchronization therapy. In this paper we summarize the usefulness of different diagnostic modalities with special emphasis on the role of surface electrocardiogram as a major predictor of response to cardiac resynchronization therapy.
Assuntos
Terapia de Ressincronização Cardíaca/métodos , Eletrocardiografia/métodos , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/prevenção & controle , Avaliação de Resultados em Cuidados de Saúde/métodos , Disfunção Ventricular Esquerda/prevenção & controle , Insuficiência Cardíaca/complicações , Humanos , Prognóstico , Resultado do Tratamento , Disfunção Ventricular Esquerda/complicaçõesRESUMO
Percutaneous coronary angioplasty is increasingly employed in the treatment of patients with complex coronary artery disease. Different steerable guide wires used to open occluded vessel and facilitate balloon and stent deployment. However, the guide-wire itself is not without hazard: it may perforate or dissect the vessel, but fracture or entrapment is uncommon. Its management depends on the clinical situation of the patient, as well as the position and length of the remnant. In this review we discuss the angioplasty guide-wire fracture and entrapment risk factors, potential risks and management.
Assuntos
Angioplastia Coronária com Balão/instrumentação , Vasos Coronários , Remoção de Dispositivo/métodos , Análise de Falha de Equipamento/métodos , Corpos Estranhos/terapia , Angioplastia Coronária com Balão/efeitos adversos , Cateterismo/métodos , Doença das Coronárias/terapia , Remoção de Dispositivo/efeitos adversos , Falha de Equipamento/estatística & dados numéricos , Corpos Estranhos/etiologia , Humanos , Isquemia Miocárdica/etiologia , Intervenção Coronária Percutânea/métodos , Fatores de RiscoRESUMO
Entrapment and detachment of guidewire fractures during percutaneous coronary intervention (PCI) are very rare, but can lead to life-threatening complications such as embolization, thrombus formation, and perforation. Surgical extraction of the remnant fragments is recommended if the percutaneous retrieval is not possible. We present a case of remnant guidewire into the left anterior descending artery (LAD) and aorta that led to acute coronary thrombosis following primary angioplasty. Surgical retrieval was possible only through a left main (LM) approach.
Assuntos
Angioplastia Coronária com Balão/efeitos adversos , Infarto Miocárdico de Parede Anterior/cirurgia , Aorta/cirurgia , Vasos Coronários/cirurgia , Corpos Estranhos/cirurgia , Adulto , Angioplastia Coronária com Balão/instrumentação , Infarto Miocárdico de Parede Anterior/diagnóstico por imagem , Aortografia , Angiografia Coronária , Trombose Coronária/etiologia , Trombose Coronária/cirurgia , Vasos Coronários/patologia , Corpos Estranhos/diagnóstico por imagem , Corpos Estranhos/etiologia , Humanos , MasculinoRESUMO
BACKGROUND: There is no evidence that the use of contrast media (CM) in diabetic patients with serum creatinine <130 µmole/L leads to metformin accumulation and subsequent lactic acidosis. Therefore, the objective of this investigation was to monitor cardiac patients for the effects of CM on their metformin plasma concentration and serum creatinine clearance (ClCr). METHODS: Metformin plasma concentrations were measured by a new, fully validated specific, precise, and accurate ultra-high-performance liquid chromatography tandem mass-spectrometric assay. The detection was performed using positive electrospray ionization in the multiple reaction monitoring mode. Fifty patients with serum creatinine levels <130 µmole/L were monitored for the effect of CM exposure on metformin concentration and ClCr. Pharmacokinetic parameters were calculated in 8 of these patients, and metformin accumulation was monitored in 10 patients before and after their exposure to CM. RESULTS: Linear response (r ≥ 0.998) was observed over the range of 5-2000 ng/mL of metformin, with the lower limit of quantification of 2.3 ng/mL. The intraday and interday precision (relative standard deviation) values were <13%, and the accuracy (relative error) was <-10% for metformin concentrations. The assay was sensitive to follow the pharmacokinetics of metformin in humans during a dosing interval after an oral dose at steady state. Metformin pharmacokinetic parameters were estimated in 8 patients exposed to CM. The mean C(max) of 1.9 ± 0.6 mg/L was attained at 4.1 ± 1.9 hours. There was no evidence of any drug accumulation or altered elimination due to the exposure to CM in the current population. ClCr showed no significant difference (P > 0.05) before (92.8 ± 11.3 mL/min) and after 48 hours (90.5 ± 10.5 mL/min) of exposure to CM. CONCLUSIONS: Our data suggest that the recommendation to withhold metformin in diabetic patients during CM exposure could be revised to withholding the drug only in patients with moderate to severe renal dysfunction.
Assuntos
Meios de Contraste/farmacologia , Diabetes Mellitus Tipo 2/sangue , Monitoramento de Medicamentos/métodos , Cardiopatias/diagnóstico , Hipoglicemiantes/sangue , Metformina/sangue , Acidose Láctica/prevenção & controle , Cateterismo Cardíaco/efeitos adversos , Cromatografia Líquida de Alta Pressão , Meios de Contraste/efeitos adversos , Creatinina/sangue , Estudos Transversais , Diabetes Mellitus Tipo 2/complicações , Diabetes Mellitus Tipo 2/tratamento farmacológico , Diabetes Mellitus Tipo 2/metabolismo , Nefropatias Diabéticas/complicações , Interações Medicamentosas , Feminino , Cardiopatias/complicações , Humanos , Hipoglicemiantes/farmacocinética , Limite de Detecção , Masculino , Metformina/farmacocinética , Pessoa de Meia-Idade , Insuficiência Renal/complicações , Reprodutibilidade dos Testes , Espectrometria de Massas por Ionização por Electrospray , Espectrometria de Massas em TandemRESUMO
Troponins are regulatory proteins that form the cornerstone of muscle contraction. The amino acid sequences of cardiac troponins differentiate them from that of skeletal muscles, allowing for the development of monoclonal antibody-based assay of troponin I (TnI) and troponin T (TnT). Along with the patient history, physical examination and electrocardiography, the measurement of highly sensitive and specific cardiac troponin has supplanted the former gold standard biomarker (creatine kinase-MB) to detect myocardial damage and estimate the prognosis of patients with ischemic heart disease. The current guidelines for the diagnosis of non-ST segment elevation myocardial infarction are largely based on an elevated troponin level. The implementation of these new guidelines in clinical practice has led to a substantial increase in the frequency of myocardial infarction diagnosis. Automated assays using cardiac-specific monoclonal antibodies to cardiac TnI and TnT are commercially available. They play a major role in the evaluation of myocardial injury and prediction of cardiovascular outcome in cardiac and non-cardiac causes. In this review we discuss the clinical applications of cardiac troponins and the interpretation of elevated levels in the context of various clinical settings.
RESUMO
Abciximab (ReoPro, Eli Lilly and Company, Indianapolis, Indiana) is an intravenous agent that had been approved for treatment of acute coronary syndrome undergoing coronary interventions. It is a chimeric monoclonal antibody fragment that binds to the glycoprotein IIb/IIIa receptor with a potential for the development of an immune response to variable portions within the antigen binding site following its administration. We describe a 58-year-old man who developed sudden headache, short of breath, choking and restlessness after receiving Abciximab for coronary intervention. Discontinuation of abciximab and administration of intravenous fluids, steroid and antihistamines led to improvement of his symptoms gradually.
RESUMO
Functional mitral regurgitation is a significant complication of end-stage cardiomyopathy. Dysfunction of one or more components of the mitral valve apparatus occurs in 39-74% and affects almost all heart failure patients. Survival is decreased in subjects with more than mild mitral regurgitation irrespective of the aetiology of heart failure. The goal of treating functional mitral regurgitation is to slow or reverse ventricular remodelling, improve symptoms and functional class, decrease the frequency of hospitalization for congestive heart failure, slow progression to advanced heart failure (time to transplant) and improve survival. This article reviews the role of mitral valve surgery in patients with heart failure and dilated cardiomyopathy.
RESUMO
Systemic lupus erythematosus is relatively common medical disorder with female predominance. This disorder can affect any organ system. Cardiac involvement is variable which can include pericardium, myocardium and endocardium. The endocardial involvement commonly affects mitral and aortic valves. This report discusses lupus endocarditis in young man with atypical presentation.