1.
BMC Cardiovasc Disord ; 20(1): 171, 2020 04 15.
Artigo em Inglês | MEDLINE | ID: mdl-32293279

RESUMO

BACKGROUND: Insertable cardiac monitors are utilized for the diagnosis of arrhythmias and traditionally have been inserted within hospitals. Recent code updates allow for reimbursement of office-based insertions; however, there is limited information regarding the resources and processes required to support in-office insertions. We sought to determine the safety and feasibility of in-office insertion of the BioMonitor 2 and better understand in-office procedures, including patient selection, pre-insertion protocols, resource availability, and staff support. METHODS: Patients meeting an indication for a rhythm monitor were prospectively enrolled into this single-arm, non-randomized trial. All patients underwent insertion in an office setting. Two follow-up visits at days 7 and 90 were required. Information on adverse events, device performance, office site preparations, and resource utilization were collected. RESULTS: Eighty-two patients were enrolled at six sites. Insertion was successful in all 77 patients with an attempt. Oral anticoagulation was stopped in 20.8% of patients and continued through insertion in 23.4%, while prophylactic antibiotics were infrequently utilized (37.7% of study participants). On average, the procedure required a surgeon plus two support staff and 35 min in an office room to complete the 8.4 min insertion procedure. The mean R-wave amplitude was 0.77 mV at insertion and 0.67 mV at 90-days with low noise burden (2.7%). There were no procedure related complications. Two adverse events were reported (event rate 2.7% [95% CI 0.3, 9.5%]). CONCLUSIONS: In-office insertion of the BioMonitor 2 is safe and feasible. Devices performed well with high R-wave amplitudes and low noise burden. These results further support shifting cardiac monitor insertions to office-based locations. TRIAL REGISTRATION: clinicaltrials.gov, NCT02756338. Registered 29 April 2016.


Assuntos
Procedimentos Cirúrgicos Ambulatórios , Arritmias Cardíacas/diagnóstico , Eletrocardiografia Ambulatorial/instrumentação , Frequência Cardíaca , Telemetria/instrumentação , Adulto , Procedimentos Cirúrgicos Ambulatórios/efeitos adversos , Arritmias Cardíacas/fisiopatologia , Desenho de Equipamento , Estudos de Viabilidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Duração da Cirurgia , Segurança do Paciente , Valor Preditivo dos Testes , Vigilância de Produtos Comercializados , Estudos Prospectivos , Fatores de Risco , Fatores de Tempo , Estados Unidos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA