Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
Eur Radiol ; 33(2): 1286-1296, 2023 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-35962816

RESUMO

OBJECTIVE: To assess the diagnostic accuracy and agreement of CT and MRI in terms of the Bosniak classification version 2019 (BCv2019). MATERIALS AND METHODS: A prospective multi-institutional study enrolled 63 patients with 67 complicated cystic renal masses (CRMs) discovered during ultrasound examination. All patients underwent CT and MRI scans and histopathology. Three radiologists independently assessed CRMs using BCv2019 and assigned Bosniak class to each CRM using CT and MRI. The final analysis included 60 histopathologically confirmed CRMs (41 were malignant and 19 were benign). RESULTS: Discordance between CT and MRI findings was noticed in 50% (30/60) CRMs when data were analyzed in terms of the Bosniak classes. Of these, 16 (53.3%) were malignant. Based on consensus reviewing, there was no difference in the sensitivity, specificity, and accuracy of the BCv2019 with MRI and BCv2019 with CT (87.8%; 95% CI = 73.8-95.9% versus 75.6%; 95% CI = 59.7-87.6%; p = 0.09, 84.2%; 95% CI = 60.4-96.6% versus 78.9%; 95% CI = 54.4-93.9%; p = 0.5, and 86.7%; 95% CI = 64.0-86.6% versus 76.7%; 95% CI = 75.4-94.1%; p = 0.1, respectively). The number and thickness of septa and the presence of enhanced nodules accounted for the majority of variations in Bosniak classes between CT and MRI. The inter-reader agreement (IRA) was substantial for determining the Bosniak class in CT and MRI (k = 0.66; 95% CI = 0.54-0.76, k = 0.62; 95% CI = 0.50-0.73, respectively). The inter-modality agreement of the BCv219 between CT and MRI was moderate (κ = 0.58). CONCLUSION: In terms of BCv2019, CT and MRI are comparable in the classification of CRMs with no significant difference in diagnostic accuracy and reliability. KEY POINTS: • There is no significant difference in the sensitivity, specificity, and accuracy of the BCv2019 with MRI and BCv2019 with CT. • The number of septa and their thickness and the presence of enhanced nodules accounted for the majority of variations in Bosniak classes between CT and MRI. • The inter-reader agreement was substantial for determining the Bosniak class in CT and MRI and the inter-modality agreement of the BCv219 between CT and MRI was moderate.


Assuntos
Doenças Renais Císticas , Neoplasias Renais , Humanos , Doenças Renais Císticas/diagnóstico , Reprodutibilidade dos Testes , Tomografia Computadorizada por Raios X , Imageamento por Ressonância Magnética , Rim/patologia , Estudos Retrospectivos
2.
Insights Imaging ; 12(1): 85, 2021 Jun 26.
Artigo em Inglês | MEDLINE | ID: mdl-34173891

RESUMO

PURPOSE: To compare effectiveness of three widely used embolic agents in partial splenic embolization (PSE) by analyzing their clinical, laboratory, and radiological outcomes within one year of follow-up. MATERIALS AND METHODS: This retrospective study examined 179 patients who underwent PSE to manage hypersplenism secondary to cirrhosis. Patients were divided into 3 groups according to embolic agent used. Group 1 (gelatin sponge) included 65 patients, group 2 (embospheres) included 58 patients, and group 3 (PVA) included 56 patients. Clinical, laboratory, and radiological outcomes were compared between groups. RESULTS: The technical success rate was 100% in all groups. Pain as a major complication was lower in the gelatin sponge group (20%) compared to the embosphere group (31%) and PVA group (32.3%). Major complications other than pain were found in 20.1%; 24.6% in gelatin sponge group, 15.5% in embosphere group and 19.6% in PVA group (p = 0.045). WBCs and platelet counts showed a significant increase after PSE in all groups. Entire splenic volume as measured by computed tomography after PSE showed no significant difference among the 3 groups; however, the volume of infarcted spleen was significantly lower in the gelatin sponge group compared to other two groups (p = 0.001). The splenic span was significantly reduced one-year post-procedure in three groups (p = 0.006), and it was significantly less in embosphere and PVA groups compared to gelatin sponge group (p < 0.05). Recurrent bleeding was higher in gelatin sponge group (p < 0.05). CONCLUSIONS: Permanent embolic materials achieved better laboratory and radiological outcomes than gelatin sponge particles in PSE of cirrhotic hypersplenism patients. However, permanent particles were associated with greater abdominal pain.

3.
J Magn Reson Imaging ; 53(1): 292-304, 2021 01.
Artigo em Inglês | MEDLINE | ID: mdl-32715577

RESUMO

BACKGROUND: The diagnosis of sonographically indeterminate adnexal masses (AM) signifies a major challenge in clinical practice. Early detection and characterization have increased the need for accurate imaging evaluation before treatment. PURPOSE: To assess the validity and reproducibility of the ADNEX MR Scoring system in the diagnosis of sonographically indeterminate AM. STUDY TYPE: A prospective multicenter study. POPULATION: In all, 531 women (mean age, 44 ± 11.2 years; range, 21-79 years) with 572 sonographically indeterminate AM. FIELD STRENGTH/SEQUENCE: 1.5T/precontrast T1 -weighted imaging (WI) fast spin echo (FSE) (in-phase and out-of-phase, with and without fat suppression); T2 -WI FSE; diffusion-WI single-shot echo planner with b-values of 0 and 1000 s/mm2 ; and dynamic contrast-enhanced perfusion T1 -WI liver acquisition with volume acceleration (LAVA). ASSESSMENT: All MRI examinations were evaluated by three radiologists, and the AM were categorized into five scores based on the ADNEX MR Scoring system. Score 1: no AM; 2: benign AM; 3: probably benign AM; 4: indeterminate AM; 5: probably malignant AM. Histopathology and imaging follow-up were used as the standard references for evaluating the validity of the ADNEX MR Scoring system for detecting ovarian malignancy. STATISTICAL TESTS: Four-fold table test, kappa statistics (κ), and receiver operating characteristic (ROC) curve. RESULTS: In all, 136 (23.8%) AM were malignant, and 436 (76.2%) were benign. Of the 350 AM classified as score 2, one (0.3%) was malignant; of the 62 AM classified as score 3, six (9.7%) were malignant; of the 73 AM classified as score 4, 43 (58.9%) were malignant; and of the 87 AM categorized as score 5, 86 (98.9%) were malignant. The best cutoff value for predicting malignant AM was score >3 with sensitivity and specificity of 92.9% and 94.9%, respectively. The interreader agreement of the ADNEX MR Scoring was very good (κ = 0.861). DATA CONCLUSION: The current study supports the high validity and reproducibility of the ADNEX MR Scoring system for the diagnosis of sonographically indeterminate AM. LEVEL OF EVIDENCE: 1 TECHNICAL EFFICACY STAGE: 2.


Assuntos
Doenças dos Anexos , Anexos Uterinos , Doenças dos Anexos/diagnóstico por imagem , Adulto , Feminino , Humanos , Imageamento por Ressonância Magnética , Pessoa de Meia-Idade , Estudos Prospectivos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
4.
Eur Radiol ; 31(2): 674-684, 2021 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-32809166

RESUMO

OBJECTIVE: The American College of Radiology (ACR) recently published the ovarian-adnexal reporting and data system (O-RADS) to provide guidelines to physicians who interpret ultrasound (US) examinations of adnexal masses (AM). This study aimed to compare the O-RADS with two other well-established US classification systems for diagnosis of AM. METHODS: This retrospective multicenter study between May 2016 and December 2019 assessed consecutive women with AM detected by the US. Five experienced consultant radiologists independently categorized each AM according to O-RADS, gynecologic imaging reporting and data system (GI-RADS), and international ovarian tumor analysis (IOTA) simple rules. Pathology and adequate follow-up were used as reference standards for calculating the validity of three US classification systems for diagnosis of AM. Kappa statistics were used to assess the inter-reviewer agreement (IRA). RESULTS: A total of 609 women (mean age, 48 ± 13.7 years; range, 18-72 years) with 647 AM were included. Of the 647 AM, 178 were malignant and 469 were benign. Malignancy rates were comparable to recommended rates by previous literature in O-RADS and IOTA, but higher in GI-RADS. O-RADS had significantly higher sensitivity for malignancy than GI-RAD and IOTA (p = 0.003 and 0.0007, respectively), but non-significant slightly lower specificity (p > 0.05). O-RADS, GI-RADS, and IOTA showed similar overall IRA (κ = 0.77, 0.69, and 0.63, respectively) with a tendency toward higher IRA with O-RADS than with GI-RADS and IOTA. CONCLUSIONS: O-RADS compares favorably with GI-RADS and IOTA. O-RADS had higher sensitivity than GI-RADS and IOTA simple rules with relatively similar specificity and reliability. KEY POINTS: • The malignancy rates were comparable to recommended rates by previous literature in O-RADS and IOTA, but higher in GI-RADS. • The O-RADS had significantly higher sensitivity for malignancy than GI-RADS and IOTA (96.8% vs 92.7% and 92.1%; p = 0.003 and 0.0007, respectively), but non-significant slightly lower specificity (92.8% vs 93.6% and 93.2%, respectively; p > 0.05). • The O-RADS, GI-RADS, and IOTA showed similar overall inter-reviewer agreement (IRA) (κ = 0.77, 0.69, and 0.63, respectively), with a tendency toward higher IRA with O-RADS than with GI-RADS and IOTA.


Assuntos
Doenças dos Anexos , Neoplasias Ovarianas , Doenças dos Anexos/diagnóstico por imagem , Adulto , Sistemas de Dados , Feminino , Humanos , Pessoa de Meia-Idade , Neoplasias Ovarianas/diagnóstico por imagem , Reprodutibilidade dos Testes , Estudos Retrospectivos , Sensibilidade e Especificidade , Ultrassonografia
5.
Clin Imaging ; 66: 42-53, 2020 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-32450482

RESUMO

Ear malformations represent 50% of ear, nose and throat malformations. Ear malformations cause conductive hearing loss (CHL) and/or sensorineural hearing loss (SNHL) with a significant childhood disability worldwide. Early accurate diagnosis and treatment are mandatory to enhance language and speech development. Understanding the embryology of the ear explains the outcome of ototoxic prenatal insult according to the affected gestational age and the incidence of association among inner, middle, and external ear malformations. Computed tomography (CT) and magnetic resonance imaging (MRI) examinations of the temporal bone are used in the evaluation of ear malformations. In this review article, the spectrum of ear malformations is discussed in detail with hints on the ear embryology, the ear radiological anatomy, and radiological determinant factors of operative reconstruction of ear anomalies.


Assuntos
Orelha Interna/anormalidades , Orelha Interna/diagnóstico por imagem , Criança , Feminino , Idade Gestacional , Perda Auditiva Neurossensorial/diagnóstico por imagem , Humanos , Idioma , Imageamento por Ressonância Magnética/efeitos adversos , Masculino , Ototoxicidade , Radiografia , Radiologistas , Radiologia , Osso Temporal/anormalidades , Osso Temporal/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA