Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 11 de 11
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
Polymers (Basel) ; 14(16)2022 Aug 22.
Artigo em Inglês | MEDLINE | ID: mdl-36015684

RESUMO

The main objective of this work is to develop a variety of hybrid high-density polyethylene (HDPE) micro- and nanocomposites and to investigate their thermal, mechanical, and morphological characteristics as a function of number of fillers and their contents percentage. In this study, 21 formulations of the composites were prepared using fillers with different sizes including micro fillers such as talc, calcium carbonate (CaCO3), as well as nano-filler (fumed silica (FS)) though the melt blending technique. The morphological, mechanical, and thermal properties of the composite samples were evaluated. The morphological study revealed negligible filler agglomerates, good matrix-filler interfacial bonding in case of combined both CaCO3 and FS into the composites. Sequentially, improvements in tensile, flexural and Izod impact strengths as a function of fillers loading in the HDPE matrix have been reported. The maximum enhancement (%) of tensile, flexural and impact strengths were 127%, 86% and 16.6%, respectively, for composites containing 25% CaCO3 and 1% FS without any inclusion of talc filler; this indicates that the types/nature, size, quantity and dispersion status of fillers are playing a major role in the mechanical properties of the prepared composites more than the number of the used fillers.

2.
Sci Rep ; 12(1): 12497, 2022 Jul 21.
Artigo em Inglês | MEDLINE | ID: mdl-35864131

RESUMO

This article presents a novel metamaterial (MTM) with a mirror symmetric resonator that exhibits multiple resonances of transmission coefficient covering the L, S, C, and X bands. The resonating patch is constructed on a low-loss Rogers (RT5880) substrate with a dimension of 20 × 20 × 1.575 mm3. It consists of four equal quartiles with each quartile made with interconnected split-ring resonators; the quartiles are in mirror symmetry with each other. The proposed MTM exhibits resonances at 1.98 GHz, 3.67 GHz, 4.74 GHz, 8.38 GHz, and 10.8 GHz, and electromagnetic characterization is performed through studies of permittivity, permeability, refractive index, and impedances. Power analysis is also performed, and the effect of polarized incident waves is studied. An electromagnetic characterization study reveals that the proposed MTM shows negative permittivity with near-zero permeability and refractive index. It also reveals very little power consumption in the vicinity of the resonances. The dielectric-based frequency tuning is studied by using different dielectric layers over the patch that provides good frequency tuning; this method provides flexibility for adjusting the resonance frequencies in accordance with the application demand. The measured result of the proposed unit cell with the dielectric layer is extracted using a vector network analyzer, and the results exhibit good similarity with the simulated ones. The above-mentioned properties, along with a good effective medium ratio (EMR) of 7.57 indicate that this MTM is suitable for frequency selective applications in microwave devices such as antenna performance improvement and sensing.

3.
Acta Radiol Open ; 11(6): 20584601221105228, 2022 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-35677731

RESUMO

Background: Magnetic Resonance Imaging (MRI) is considered a vital in depicting multiple sclerosis (MS) lesions. Current studies demonstrate that proton density (PD) weighted images (WI) are superior to T2 WI in detecting MS lesions (plaques) in the spinal cord. Purpose: To evaluate the diagnostic value of filtered fused PD/T2 weighted images in detecting cervical spinal cord MS lesions. Material and Methods: In this retrospective study, we selected a sample size of 50 MS patients. Using contrast limited adaptive histogram equalization (CLAHE), a digital image processing filter was used on the (PD/T2) fused images. The produced images were inspected and compared to the original PD images by two experienced neuroradiologists using interobserver and intraobserver. An ROI analysis was also performed on the processed and original PD images. Results: The repeatability measurement of the match between the two examinations was highly consistent for both neuroradiologists. The repeatability for both neuroradiologists was 96.05%, and the error measurement was 3.95%. The reproducibility measurement of the neuroradiologist's evaluation shows that the processed images could help to identify lesions better [excellent (84.87%)] than PD images [good (61.19%)]. ROIs analysis was performed on 113 MS lesions and normal areas in different images within the sample size. It revealed an enhanced ratio of 2.2 between MS lesions and normal spinal cord tissue in processed fused images compared to 1.34 in PD images. Conclusion: The processed images of the fused images (PD/T2) have superior diagnostic sensitivity for MS lesions in the cervical spine than PD images alone.

4.
Micromachines (Basel) ; 13(6)2022 Jun 17.
Artigo em Inglês | MEDLINE | ID: mdl-35744573

RESUMO

This study provides an eight-component multiple-input multiple-output (MIMO) antenna architecture for fifth-generation (5G) mobile communication systems. The single antenna element is comprised of an L-shaped radiating component, an L-shaped parasitic element, and a ground plane with a rectangular slot. The main element with a slot-loaded ground plane helps to draw current from a coaxial feed from the other side of the board, while the parasitic element helps to elongate the current path and improve the impedance of the system. This enables the system to radiate at two different frequency ranges: 3.34-3.7 GHz and 4.67-5.08 GHz, with 360 MHz and 410 MHz bandwidths, respectively. For MIMO configuration, the radiating elements are designed on either side of a 0.8 mm thick FR-4 substrate, allowing space to accommodate a battery, radio frequency (RF) systems and subsystems, and camera and sensor modules. The corner and the middle elements are arranged in such a manner so that they can provide spatial and pattern diversity. Furthermore, at least 12 dB of isolation is established between any two radiating elements. Various MIMO performance parameters were evaluated, e.g., mean effective gain (MEG), channel capacity (CC), envelope correlation coefficient (ECC), realized gain, far-field characteristics, and efficiency. Single- and double-hand mode evaluations were performed to further demonstrate the capability of the proposed MIMO antenna. A prototype of the proposed MIMO antenna was manufactured and assessed to verify the simulated data. The measured and simulated results were found to be in good agreement. On the basis of its performance characteristics, the designed MIMO system could be used in 5G communication systems.

5.
Sci Rep ; 12(1): 10355, 2022 Jun 20.
Artigo em Inglês | MEDLINE | ID: mdl-35725734

RESUMO

In this paper, we present an analytical study for the investigation of the effects of the magnetoelectric elements of a reciprocal and nonreciprocal bianisotropic grounded substrate on the input impedance, resonant length of a dipole antenna as well as on the mutual coupling between two element printed dipole array in three configuration geometries: broadside, collinear and echelon printed on the same material. This study examines also the effect of the considered bianisotropic medium on the electric and magnetic field distributions that has been less addressed in the literature for antenna structures. Computations are based on the numerical resolution, using the spectral method of moments, of the integral equation developed through the mathematical derivation of the appropriate spectral Green's functions of the studied dipole configuration. Original results, for chiral, achiral, Tellegen and general bi-anisotropic media cases, are obtained and discussed with the electric and magnetic field distributions for a better understanding and interpretation. These interesting results can serve as a stepping stone for further works to attract more attention to the reciprocal and non-reciprocal Tellgen media in-depth studies.

6.
Polymers (Basel) ; 14(9)2022 Apr 22.
Artigo em Inglês | MEDLINE | ID: mdl-35566884

RESUMO

In this work, graphite nanoplatelets (GNP) were incorporated into poly (ethylene terephthalate) (PET) matrix to prepare PET-GNP nanocomposites using a melt compounding followed by compression moulding and then quenching process. Both static and dynamic mechanical properties of these quenched materials were characterized as a function of GNP contents using dynamic mechanical thermal analysis (DMTA) and tensile machine, respectively. The results demonstrated that the addition of GNP improved the stiffness of PET significantly. Additionally, the maximum increase in the storage modulus of 72% at 6 wt.% GNP. The incorporation of GNP beyond 6 wt.% into PET decreases the storage moduli, but they remain higher than pure PET. The observed reduction could be due to agglomeration, resulting in poorer dispersion and distribution of higher levels of GNP into the PET matrix. In contrast to the results for moduli, tensile strength and elongations at break reduce with increasing the GNP content. For example, tensile strength reduced from ∼46 MPa (neat PET) to ∼39 MPa (-15%) for the nanocomposites containing 2 wt.% GNP. This reduction is accompanied by a decline in elongation at break from ∼6.3 (neat PET) to ∼3.4 (-46%) for the same nanocomposites. Such reductions are followed by a gradual decrease in upon further addition of GNP. These reductions indicate that increasing GNP loadings, results in brittleness in nanocomposites. In addition, it was found that quenched PET and composite samples were not fully crystallized after processing and therefore (cold) crystallized during the first heating cycle DMTA, as indicated by a rise in storage moduli above the glass transition temperature during the DMTA first heat. Furthermore, mathematical models based on non-linear theories are developed to capture the experimental data. For this, a set of mechanical stress-strain data is used for model parameters' identification. Another set of data is used for the model validation that demonstrates good agreements with the experimental study.

7.
Sci Rep ; 12(1): 8495, 2022 May 19.
Artigo em Inglês | MEDLINE | ID: mdl-35589758

RESUMO

A couple ring enclosed circular geometric resonator (CRECGR) based dual-band polarization insensitive metamaterial (MM) with high effective medium ratio (EMR), and excellent absorptance is proposed in this study, which can be utilized as a sensor and absorber in the 5G sub-6 GHz frequency range. A circular geometry-based unique patch has been introduced in the proposed unit cell to achieve high polarization insensitive properties with excellent absorption for the 5G sub-6 GHz spectrum. The distinctive feature of this proposed CRECGR unit cell is its simple and unique structure with a high EMR of 11.13, polarization insensitive up to 180°, and epsilon negative (ENG) properties, including a negative refractive index and near-zero permeability for 5G sub-6 GHz applications. Furthermore, this designed unit cell yields excellent absorption properties with high quality factor. The designed MM unit cell is fabricated on low loss Rogers RT5880 printed media with an electrical dimension of 0.089λ × 0.089λ × 0.017λ. The performance of the designed CRECGR metamaterial is determined using Computer Simulation Technology (CST), Advanced Design Software (ADS), and measurements. The CRECGR unit cell offers dual resonances at 3.37 GHz and 5.8 GHz, covering the 5G sub-6 GHz band with ENG, near-zero permeability and negative index. The polarization insensitive properties of the unit cell were also investigated for maximum angle of incidence, which confirmed the identical response. The simulated outcome is verified by experiment with excellent accordance. Moreover, the unit cell performance with a complete backplane is explored, noting a maximum absorption of 99.9% for all normal and oblique incidence waves, suitable for sensing and antenna systems. In addition, the suggested unit cell sensing performance is evaluated using the permittivity-based sensing model. The proposed MM outperforms recent related studies in terms of polarization insensitivity up to 180°, high insensitive absorptivity, high EMR, and sensing applications. These features prove that the proposed CRECGR metamaterial is perfect for 5G Applications.

8.
Nanomaterials (Basel) ; 12(3)2022 Jan 27.
Artigo em Inglês | MEDLINE | ID: mdl-35159770

RESUMO

Carbon felt (CF) is an inexpensive carbon-based material that is highly conductive and features extraordinary inherent surface area. Using such a metal-free, low-cost material for energy storage applications can benefit their practical implementation; however, only limited success has been achieved using metal-free CF for supercapacitor electrodes. This work thoroughly studies a cost-effective and simple method for activating metal-free self-supported carbon felt. As-received CF samples were first chemically modified with an acidic mixture, then put through a time optimization two-step electrochemical treatment in inorganic salts. The initial oxidative exfoliation process enhances the fiber's surface area and ultimately introduced oxygen functional groups to the surface, whereas the subsequent reduction process substantially improved the conductivity. We achieved a 205-fold enhancement of capacitance over the as-received CF, with a maximum specific capacitance of 205 Fg-1, while using a charging current density of 23 mAg-1. Additionally, we obtained a remarkable capacitance retention of 78% upon increasing the charging current from 0.4 to 1 Ag-1. Finally, the cyclic stability reached 87% capacitance retention after 2500 cycles. These results demonstrate the potential utility of electrochemically activated CF electrodes in supercapacitor devices.

9.
Polymers (Basel) ; 13(15)2021 Jul 27.
Artigo em Inglês | MEDLINE | ID: mdl-34372077

RESUMO

Carbon fiber-reinforced polymers are considered a promising composite for many industrial applications including in the automation, renewable energy, and aerospace industries. They exhibit exceptional properties such as a high strength-to-weight ratio and high wear resistance and stiffness, which give them an advantage over other conventional materials such as metals. Various polymers can be used as matrices such as thermosetting, thermoplastic, and elastomers polymers. This comprehensive review focuses on carbon fiber-reinforced thermoplastic polymers due to the advantages of thermoplastic compared to thermosetting and elastomer polymers. These advantages include recyclability, ease of processability, flexibility, and shorter production time. The related properties such as strength, modulus, thermal conductivity, and stability, as well as electrical conductivity, are discussed in depth. Additionally, the modification techniques of the surface of carbon fiber, including the chemical and physical methods, are thoroughly explored. Overall, this review represents and summarizes the future prospective and research developments carried out on carbon fiber-reinforced thermoplastic polymers.

10.
J Infect Public Health ; 14(7): 832-838, 2021 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-34118732

RESUMO

BACKGROUND: Estimated seroprevalence of Coronavirus Infectious Disease 2019 (COVID-19), caused by the Severe Acute Respiratory Syndrome-Coronavirus-2 (SARS-CoV-2) is a critical evidence for a better evaluation of the virus spread and monitoring the progress of COVID-19 pandemic in a population. In the Kingdom of Saudi Arabia (KSA), SARS-CoV-2 seroprevalence has been reported in specific regions, but an extensive nationwide study has not been reported. Here, we report a nationwide study to determine the prevalence of SARS-CoV-2 in the population of KSA during the pandemic, using serum samples from healthy blood donors, non-COVID patients and healthcare workers (HCWs) in six different regions of the kingdom, with addition samples from COVID-19 patients. METHODS: A total of 11,703 serum samples were collected from different regions of the KSA including; 5395 samples from residual healthy blood donors (D); 5877 samples from non-COVID patients collected through residual sera at clinical biochemistry labs from non-COVID patients (P); and 400 samples from consented HCWs. To determine the seroprevalence of SARS-CoV-2, all serum samples, in addition to positive control sera from RT-PCR confirmed COVID-19 patients, were subjected to in-house ELISA with a sample pooling strategy, which was further validated by testing individual samples that make up some of the pools, with a statistical estimation method to report seroprevalence estimates. RESULTS: Overall (combining D and P groups) seroprevalence estimate was around 11% in Saudi Arabia; and was 5.1% (Riyadh), 1.5% (Jazan), 18.4% (Qassim), 20.8% (Hail), 14.7% (ER; Alahsa), and 18.8% in Makkah. Makkah samples were only D group and had a rate of 24.4% and 12.8% in the cities of Makkah and Jeddah, respectively. The seroprevalence in Saudi Arabia across the sampled areas would be 12 times the reported COVID-19 infection rate. Among HCWs, 7.5% (4.95-10.16 CI 95%) had reactive antibodies to SARS-CoV-2 without reporting any previously confirmed infection. This was higher in HCWs with hypertension. The study also presents the demographics and prevalence of co-morbidities in HCWs and subset of non-COVID-19 population. INTERPRETATION: Our study estimates the overall national serological prevalence of COVID-19 in Saudi Arabia to be 11%, with an apparent disparity between regions. This indicates the prevalence of asymptomatic or mild unreported COVID-19 cases.


Assuntos
COVID-19 , SARS-CoV-2 , Anticorpos Antivirais , Humanos , Pandemias , Arábia Saudita/epidemiologia , Estudos Soroepidemiológicos
11.
Cureus ; 13(12): e20437, 2021 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-35047274

RESUMO

Background The COVID-19 pandemic is one of the largest global healthcare crises in nearly a century. To face this global health emergency, health institutions have had to readjust their functioning while ensuring the continuity of care and protecting medical staff and patients. Our aim in this study was to assess the consequences of the COVID-19 outbreak on family medicine and its practice in Saudi Arabia. Methods This cross-sectional study was conducted during the period from June 30, 2020, to July 20, 2020, by posting an online survey on social media platforms (WhatsApp and Twitter) and emailing physicians individually to collect data on the impact of the COVID-19 pandemic on family medicine and primary care practices during the period of lockdown in Saudi Arabia. Results A total of 382 primary healthcare (PHC) providers participated in the study (males: 213 (55.8%); females: 169 (44.2%)). The mean age and standard deviation of the population were 38.27±7.46. Most participants were from governmental health sectors. Participants revealed that they have a good level of knowledge regarding COVID-19. However, they indicated confusion regarding the knowledge due to changing recommendations or multiple-source information. Only 57.3% of respondents received relevant training on the use of personal protective equipment (PPE). The most frequently used PPE were surgical masks (100%) and gloves (98.4%). The highly protective N95 masks were used by only 55.7%. Many health care workers indicated a high rate of stress and anxiety about the COVID-19 pandemic. Data obtained are suggestive that there was a reduction in outpatient visits and a reduction in consultation time. Canceled physical examinations of the patients during the consultation were encountered most of the time. There was no shortage of medications, nasopharyngeal swabs, or sanitizers. However, an occasional lack of PPEs occurred. 64.4% of the respondents used online consultations with their patients. A shortage of health care workers during the pandemic in family medicine clinics was encountered by 63.3% of the participants. Conclusion Family medicine practices are adversely affected by pandemics and lockdowns following them. It has been reported that COVID-19 interferes with preventive, chronic, and acute care visits and increases mental health visits. Outpatient visits have also decreased as well as the amount of time spent in consultations. In addition, the transition from in-person clinics to telemedicine has happened. Perhaps these changes will delay the diagnosis and prescription refills.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA