Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
3.
RSC Adv ; 13(31): 21769-21780, 2023 Jul 12.
Artigo em Inglês | MEDLINE | ID: mdl-37521157

RESUMO

Fe-gallic acid MOF embedded in an epoxy methyl cellulose polymer (CMC) thin film was synthesized and characterized by different micro-analytical tools such as: FE-SEM/EDX, XPS analysis, XRD analysis, FT-IR, and fluorescence spectroscopy. Fe-gallic acid MOF doped in a stable CMC polymer thin film is used as a novel sensor to identify CA 15-3 in the sera of patients suffering breast malignancy. The presence of appropriate functional groups in aqueous CA 15-3 solutions enables it to interact with the Fe-gallic acid MOF embedded in the thin film. The Fe-gallic acid MOF was found to absorb energy at 350 nm (λex) and emits radiation at 439 nm which was specifically quenched in the presence of CA 15-3 over a working concentration range of 0.05-570 U mL-1. In contrast to other CA 15-3 detection methods which suffered from electronic noise, interference and slowness, the Fe-gallic acid MOF proved its sensitivity as an economic, stable and reliable probe for the detection and determination of CA 15-3 in patients' serum samples with a detection limit of 0.01 U mL-1 at pH 7.2.

4.
RSC Adv ; 13(31): 21318-21326, 2023 Jul 12.
Artigo em Inglês | MEDLINE | ID: mdl-37465571

RESUMO

A low-cost, accurate, and highly selective method was used for the assessment of the human chorionic gonadotropin ß-hCG in the serum of breast and prostate cancer patients. This method is based on enhancing the intensity of luminescence displayed by the optical sensor N/S-doped carbon dots (CQDs) upon adding different concentrations of ß-hCG. The luminescent optical sensor was synthesized and characterized through absorption and emission and is tailored to present blue luminescence at λem = 345 nm and λex = 288 nm at pH 7.8 in DMSO. The enhancement of the luminescence intensity of the N/S-doped CQDs, especially, the characteristic band at λem = 345 nm, is typically used for determining ß-hCG in different serum samples. The dynamic range is 1.35-22.95 mU mL-1, and the limit of detection (LOD) and quantitation limit of detection (LOQ) are 0.235 and 0.670 mU mL-1, respectively. This method was practical, simple, and relatively free from interference effect. It was successfully applied to measure PCT in the samples of human serum, and from this method, we can assess some biomarkers of cancer-related diseases in human body.

5.
Carbohydr Polym ; 246: 116651, 2020 Oct 15.
Artigo em Inglês | MEDLINE | ID: mdl-32747283

RESUMO

Cationic and thermo-responsive polymer brushes were grafted from the surface of cellulose nanocrystals. Di(ethylene glycol) methyl ether methacrylate (MEO2MA) and poly(oligoethylene glycol) methyl ether acrylate (OEGMA300) and (2-methacryloyloxyethyl) trimethylammonium chloride (DMC) were grafted from cellulose nanocrystals (CNCs) via free radical polymerization. The CNC-g-POEGMA (CP) possessed a tunable lower critical solution temperature (LCST) of about 50 °C, and cloud point measurements confirmed that the LCST of the nanoparticles could be manipulated within the range of 40-47 °C by adjusting the DMC content. The salt effect was also investigated, and the results revealed a typical salting-out effect for the CNC-g-POEGMA after the introduction of KCl. On the other hand, the CNC-g-POEGMA-g-DMC (CPD) copolymers displayed two salt-responsive characteristics; polyelectrolyte effect at lower salt concentrations, followed by the salting-out effect at higher salt concentrations, which is dependent on the DMC content.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA