Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
Clin Cosmet Investig Dent ; 16: 237-248, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38915917

RESUMO

Purpose: This in vitro study investigated the effects of dietary solvents on the microhardness and color stability of CAD/CAM provisional restorations compared to conventional materials. Methods: Disc-shaped specimens (n=200) were fabricated from self-cured acrylic resin, two 3D-printing resins (FormLabs, NextDent), and a milled material (TelioCAD). Randomization assigned specimens (n=10/group) to immersion solutions: artificial saliva, citric acid, heptane, coffee, and tea. Microhardness and color stability were evaluated. One-way and three-way ANOVA with Tukey's post hoc test analyzed the data. Results: Dietary solvents significantly reduced the surface microhardness of all tested materials (p<0.05). Unpolished surfaces exhibited greater color changes compared to polished ones (p<0.05) across all materials. Coffee and tea induced the most substantial reductions in hardness and the most significant color alterations (p<0.05), whereas saliva and citric acid had minimal effects. Conclusion: Milled provisional restorations exhibited superior hardness and color stability. Dietary solvents significantly affected material properties over time, highlighting the importance of material selection for clinical applications.

2.
Saudi Dent J ; 35(5): 403-422, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-37520610

RESUMO

Introduction: Lithium disilicate glass-ceramic (LDC) restorations exhibit microorganism infiltration, recurrent caries, pulpal lesions, periodontal inflammation, and cement exposure to the oral environment over time. All these factors lead to restoration failure. This systematic review aimed to investigate the clinical outcomes of LDC full-coverage crowns (FCC) in permanent teeth compared with those of other full-coverage restoration materials. Materials & Methods: Search strategies were developed for four databases: Web of Science, OVID, PubMed, and Scopus. Data extraction and quality appraisals were performed by two independent reviewers. Data on the presence of caries, post-operative sensitivity, and periodontal changes were extracted from the included clinical studies. In addition to the outcome measures, data on the sample size, study groups, method of restoration fabrication, type of impression, and type of abutment were recorded. Results: We retrieved 3989 records for the title and abstract screening. Of these, 19 clinical studies met the inclusion criteria. The overall quality of the included studies indicates a low risk of bias. Most studies reported no pulpal involvement, recurrent caries, or post-operative sensitivity and presented a favorable periodontal response after the cementation of LDC-FCC during different follow-up periods. Conclusion: Based on the endodontic and periodontic clinical responses of natural tooth abutments and their supporting periodontium, LDC-FCC can be considered a clinically successful restorative option.

3.
Biomedicines ; 11(6)2023 May 29.
Artigo em Inglês | MEDLINE | ID: mdl-37371666

RESUMO

BACKGROUND AND OBJECTIVES: Labial alveolar bone thickness in the maxillary anterior region is the key factor in the placement of implants. Differences in the thickness of the bone are reported among different ethnic groups. Thus, the present study was aimed at assessing labial alveolar bone thickness in the maxillary anterior region in the population of the eastern province of Saudi Arabia. MATERIALS AND METHODS: The six anterior teeth in each of the 186 CBCT sagittal images were analyzed at three points: Point A from the facial plate at the level of the bone crest to the coronal root third, Point B to the mid-root surface, and Point C to the apical third. Crest height (Point D) was measured as the distance from the CEJ to the alveolar bone crest. The analysis was done using SPSS version 20. A p-value of <0.05 was considered statistically significant. RESULTS: The bone thickness at any given point (Point A, Point B, or Point C) was less than the preferred bone thickness of 2 mm in all six teeth. The thickness was minimum at Point B, maximum at Point C, and intermediate at Point A. This difference was found to be statistically significant (p-value < 0.05). The crestal height (Point D) was less than 3 mm, and it was not statistically significant. Comparison of bone thickness on the right and left sides for any given point was not statistically significant except at Point A in the central incisor, where it was statistically significant (p-value = 0.035). Gender comparison of bone thickness showed no difference at Point A; however, at Points B and C, it showed statistical significance (p-value < 0.05). CONCLUSIONS: The alveolar bone thickness being <2 mm in the labial anterior region warns of the importance of the proper assessment of bone during implant placement to have a predictable outcome.

4.
Artigo em Inglês | MEDLINE | ID: mdl-36673851

RESUMO

Periodontal and peri-implant soft and hard tissue in diabetic patients have always been a topic of interest for researchers and clinicians alike. Among which, a subtopic that has attracted more attention is the beneficial effect of metformin (MF) on periodontal and peri-implant soft and hard tissue. This review aimed to assess the impact of MF on the periodontal and peri-implant soft- and hard-tissue healing among diabetic patients. Research was conducted using the keywords 'metformin', 'diabetes', 'periodontitis', 'implant', and 'peri-implantitis' via the Medline (PubMed) and Google Scholar databases. Selected articles were reviewed. A total of 21 articles, discussing the impact on periodontal health (six animal studies, seven clinical studies, and three systematic reviews) and five studies on peri-implant health (four animal studies and one clinical study) were included. All have reported a positive impact of MF on decreasing the inflammatory response, oxidative stress, and ultimate bone loss. Similarly, human studies reported a positive effect of MF on clinical and radiographic parameters compared with controls. Despite systematic reviews reporting heterogeneity among the included studies, MF has shown a positive impact on periodontal health. In animal, clinical studies, and systematic reviews, MF showed a protective impact on periodontal and peri-implant health.


Assuntos
Peri-Implantite , Periodontite , Animais , Humanos , Periodontite/tratamento farmacológico , Peri-Implantite/tratamento farmacológico , Cicatrização
5.
Saudi Dent J ; 34(8): 681-688, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-36570576

RESUMO

Purpose: This study aimed to investigate the current state of research on tooth extraction socket preservation. The main aim of this study was to consolidate the research published on extraction socket preservation from 1968 to 2020 in Scopus indexed journals. Methodology: The bibliometric method, a quantitative analysis investigating publishing trends and patterns, was used. Scopus database was used to retrieve the bibliographic records of published scholarly output. The analysis was performed using software and visualization tools like MS Excel, VOSviewer, Cite Space, Biblioshiny (RStudio), and BibExcel. Results: The result showed a gradual increase in research, whereby a substantial increase was observed from 2005 to 2006. Six hundred nineteen articles were published in 173 journals with total citations of 12091. Most published articles were from the USA, Italy, Germany, and China. The authorship pattern showed an interdisciplinary and collaborative approach among researchers. Conclusion: This bibliometric analysis can guide researchers, funding agencies, industry, and institutions.

6.
J Periodontol ; 92(12): 1687-1696, 2021 12.
Artigo em Inglês | MEDLINE | ID: mdl-33856690

RESUMO

BACKGROUND: There is growing evidence on the impact of thin gingival phenotype (TnP) and inadequate keratinized mucosa width (KMW <2 mm) around dental implants on peri-implant health. This study investigated the role of TnP and inadequate KMW (<2 mm) as risk indicators for peri-implantitis and mucositis and on dental patient-reported outcomes. METHODS: Sixty-three patients with 193 implants (mean follow-up of 6.9 ± 3.7 years) were given a clinical and radiographic examination and a questionnaire to assess patient awareness of food impaction and pain/discomfort. Chi-squared tests and regression analysis for clustered data were used to compare outcomes. RESULTS: Implants with TnP had a statistically higher prevalence of peri-implantitis (27.1% versus 11.3%; PR, 3.32; 95% confidence interval (CI), 1.64-6.72; P = 0.001) peri-implant mucositis (42.7% versus 33%; PR, 1.8; 95% CI, 1.12-2.9; P = 0.016) and pain/discomfort during oral hygiene (25% versus 5%; PR, 3.7; 95% CI, 1.06-12.96; P = 0.044) than thick phenotype. Implants with inadequate KMW had a statistically higher prevalence of peri-implantitis (24.1% versus 17%; PR, 1.87; 95% CI, 1.07-3.25; P = 0.027) and peri-implant mucositis (46.6% versus 34.1%; PR, 1.53; 95% CI, 1-2.33; P = 0.05) and pain/discomfort during oral hygiene (28% versus 10%; PR, 2.37; 95% CI, 1.1-5.1; P = 0.027) than the adequate KMW. TnP was strongly associated with inadequate KMW (PR = 3.18; 95% CI, 1.69-6.04; P <0.001). CONCLUSION: TnP and inadequate KMW (<2 mm) may be significant risk indicators for peri-implant disease and pain/discomfort during brushing.


Assuntos
Implantes Dentários , Mucosite , Peri-Implantite , Implantes Dentários/efeitos adversos , Humanos , Mucosite/epidemiologia , Mucosite/etiologia , Mucosa , Peri-Implantite/epidemiologia , Peri-Implantite/etiologia , Fenótipo
7.
Clin Oral Implants Res ; 32(5): 598-607, 2021 May.
Artigo em Inglês | MEDLINE | ID: mdl-33629375

RESUMO

OBJECTIVES: The primary aim of this study was to investigate the relationship between interproximal open contacts and peri-implant disease. The secondary aim was to assess patient-reported outcome measures in relation to contact status. MATERIALS AND METHODS: A cross-sectional study was performed on 61 patients with 142 implants adjacent to at least one natural tooth. Patients underwent a clinical examination to assess contact status and width, plaque index (PI), gingival index (GI), periodontal probing depths (PPD), and bleeding on probing (BoP). Radiographic marginal bone level was measured in vertical bitewings taken within one year. A diagnosis was given to each implant. Last, subjects completed a brief questionnaire. Rao-scott chi-squared tests and generalized estimating equations (GEE) models were used to compare outcomes between groups. RESULTS: Seventy-seven (54.2%) implants were found to have ≥1 interproximal open contact. Sixty-five (45.8%) implants had closed contacts only. Implants with interproximal open contacts were significantly associated with peri-implant mucositis and peri-implantitis (p = .003) and increased prevalence of peri-implant disease (adjusted PR = 1.57; 95% CI: 1.09-2.27, p = .015). Open contact status was also associated with higher PPD (p = .045), PI scores (p = .036), and GI scores (p = .021). Open contact prevalence was 75.4% on the patient-level and 54.2% on the implant-level, involving the mesial surface of the implant restorations 68.5% of the time (p < .001). CONCLUSION: Interproximal open contacts between implant restorations and adjacent natural teeth are a risk indicator for peri-implant disease. Adequate contact between implant restorations and natural teeth may contribute to the health of peri-implant tissues.


Assuntos
Implantes Dentários , Boca Edêntula , Peri-Implantite , Estudos Transversais , Implantes Dentários/efeitos adversos , Humanos , Peri-Implantite/epidemiologia , Peri-Implantite/etiologia , Índice Periodontal
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA