Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
BMC Med Educ ; 24(1): 371, 2024 Apr 04.
Artigo em Inglês | MEDLINE | ID: mdl-38575914

RESUMO

BACKGROUND: Misconceptions should be detected early in dental students' training to improve their clinical performance. Accordingly, this study aimed to assess undergraduate dental students' knowledge and performance of master gutta-percha (GP) cone selection and fitting during clinical endodontic courses at the College of Dentistry, King Saud University. METHODS: Ninety-nine undergraduate dental students completed an online survey about their knowledge of master GP cone selection. Forty-five of these students were observed by faculty members in clinical endodontic courses while they fitted master GP cones during root canal treatments. The observers recorded the details of each student's cone-fitting techniques. The data were analysed using t-tests, one-way analysis of variance, and chi-square tests (p < 0.05). Inter- and intra-observer reliability were tested using Fliess' Kappa. RESULTS SURVEY: All participants had good knowledge of over-extended cone management, while 80.8% knew how to properly manage a short cone. The proper flaring assessment method was selected by 86.9% of the female and 34.2% of the male students, and this difference was statistically significant (p = 0.0001). OBSERVATION: The students labelled the working length on the master GP cone with an indentation in 64.4% of the cases and by bending the cone 35.6% of the time. Of all students, 84.4% encountered an apical stop, and this rate correlated significantly with the length of the cone on the master apical cone radiograph (p = 0.001). Improper shaping of the canal was the most common cause of ill-fitting cones (83.3%), while 16.7% of the students chose the wrong cone size. The final obturation length was adequate in 80% of the cases; 57.8% of the students were helped by instructors. CONCLUSIONS: Most students had the basic knowledge required to solve problems related to the selection of master GP cones. However, in the clinical setting, more than half of the students required the assistance of an instructor to adjust their cone's fit. The presence of an apical stop had the most significant effect on the length of the fitted master GP cone on radiography. The most common cause of ill-fitting master cones was improper shaping of the canal.


Assuntos
Guta-Percha , Materiais Restauradores do Canal Radicular , Feminino , Masculino , Humanos , Projetos Piloto , Estudantes de Odontologia , Cavidade Pulpar , Reprodutibilidade dos Testes , Obturação do Canal Radicular
2.
Saudi Dent J ; 35(8): 904-915, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-38107038

RESUMO

Background: The presence of middle mesial canals in mandibular molars are not commonly encountered in daily practice. However, locating and debriding such anatomical variation during the endodontic therapy is essential to avoid endodontic failure. The aim of this systematic review was to identify the overall prevalence of middle mesial canals (MMC) in mandibular molars using cone-beam computed tomography (CBCT), to assess the influence of different gender on the prevalence of MMCs in mandibular molars and to describe the MMC configurations. Methods: The review protocol was registered in the PROSPERO database (CRD42021238523). The main electronic databases were searched until February 2022 for prevalence studies on root/canal anatomy in mandibular molars using CBCT imaging, in addition to hand-searched scientific articles in peer-reviewed journals and grey literature. The quality of the included studies was assessed using the Joanna Briggs Institute Critical Appraisal tool. Egger's and Begg's tests and Pearson's chi-square test were used for statistical analysis. Results: From 523 records, 488 studies were excluded after screening the title and abstract. 35 relevant studies were included for full-text assessment and 28 studies were included in the meta-analysis. The overall prevalence of MMC out of the 19,256 teeth was 5.09% (95% CI: 2.894 to 7.784). The prevalence of MMC was 9.79% (95% CI: 4.296 to 17.224) in males and 13.96% (95% CI: 0.541 to 40.737) in females with a statistically significant difference of 4.16% (95% CI: 2.29 to 6.01). The most MMC configuration found in this review to be confluent with the mesiobuccal canal. Conclusion: The results showed an overall 5.09% prevalence of MMC in mandibular molars, with a significantly high prevalence in female subjects. Additionally, this canal was found to be confluent with the mesiobuccal canal.

3.
BMC Oral Health ; 22(1): 583, 2022 12 09.
Artigo em Inglês | MEDLINE | ID: mdl-36494650

RESUMO

BACKGROUND: The radicular groove (RG) is one of the developmental anomalies that is commonly found in maxillary incisors. The formation of radicular groove is initiated around the cingulum and can reach the root at different levels. The incidence of radicular grooves was reported in different countries but there was no published data about the incidence of RG in Saudi Arabia. Therefore, this study aimed to evaluate the incidence of radicular grooves on maxillary lateral incisors in the Saudi population using cone-beam computed tomography (CBCT). METHODS: The dental records of 490 patients (N = 490) with CBCT images of maxillary anterior teeth were screened for inclusion criteria. Then 264 included cases were evaluated independently by two Endodontists. The evaluation was performed on CBCT images in the axial, sagittal, and coronal sections using Planmeca Romexis® software. The following data were recorded for each patient: Patients' age and gender, radicular groove presence or absence, and if it is bilateral or unilateral. The type of radicular groove was recorded according to Gu's classification (type I, II, or III). RESULTS: The incidence rate of radicular grooves in maxillary lateral incisors was 4.9%. RG was found to be unilateral in 61.5% and bilateral in 38.5%. The majority of RG were classified as type I in 69.2%, followed by type II in 15.4%, and type III was found in 15.4%. CONCLUSION: 4.9% of the Saudi population has RG in the upper lateral incisor. This anatomical variation is mostly present as type I on one side only (unilateral).


Assuntos
Maxila , Raiz Dentária , Humanos , Raiz Dentária/diagnóstico por imagem , Raiz Dentária/anormalidades , Maxila/diagnóstico por imagem , Incidência , Incisivo/diagnóstico por imagem , Incisivo/anormalidades , Tomografia Computadorizada de Feixe Cônico/métodos
4.
Int J Dent ; 2020: 4030194, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32322272

RESUMO

AIM: To evaluate dentinal microcrack formation on root canals instrumented, continuously in the body temperature, with XP-endo shaper (XPES) and ProTaper Universal (PTU), by means of microcomputed tomographic (micro-CT) analysis. Methodology. Nineteen mesial roots with two separate canals (Vertucci Type IV) of extracted mandibular molars were used in this study. The root canals (N = 38) were divided into 2 groups. Group 1 (n = 19): all MB canals were instrumented with XPES. Group 2 (n = 19): all ML canals were instrumented with PTU. All roots were scanned with micro-CT before and after instrumentation. Two precalibrated examiners evaluated the cross-sectional images of each sample with DataViewer program. The dentinal microcracks (complete and incomplete) were counted in each third of the root for the preinstrumentation and the postinstrumentation images. Wilcoxin signed-rank and Mann-Whitney U tests were used for statistical analysis at a significance level of P < 0.05. RESULTS: The number of microcracks increased significantly (P < 0.05) after instrumentation with XPES in the middle and cervical thirds. The number of microcracks increased significantly (P < 0.05) after instrumentation with PTU in the cervical third only. There was no significant difference between the groups in the cervical and apical thirds. In the middle third, the XPES induced more incomplete microcracks than PTU (P < 0.05). CONCLUSION: Within the limitations of this study, there was no significant difference in the dentinal microcrack formation between XPES and PTU in the apical and cervical thirds of the root. However, XPES instrumentation induced more incomplete microcracks than PTU in the middle third of human roots.

5.
BMC Oral Health ; 14: 27, 2014 Mar 29.
Artigo em Inglês | MEDLINE | ID: mdl-24678861

RESUMO

BACKGROUND: Debridement and disinfection of the root canal system is a crucial step in endodontic procedures. The effectiveness of irrigation relies on both the mechanical flushing action and the ability of irrigants to dissolve tissue and kill bacteria. The objective of the present study is to evaluate and compare the cytotoxicity of QMix™ root canal irrigating solution on immortalized human bone marrow mesenchymal stem cells (hTERT-MSC-C1) and to compare it with that of sodium hypochlorite (NaOCl). METHODS: Immortalized human bone marrow mesenchymal stem cells (hTERT-MSCs) were exposed to QMix™ and NaOCl. Cell viability was assessed by 3-(4, 5-dimethylthiazol-2-yl)-2,5-diphenyltetrazolium bromide (MTT) and alamarBlue assays. The cell morphology was studied after two hours of exposure to QMix™ and NaOCl. Scanning electron microscopy (SEM) analyses were performed after 2- and 4-hour incubation periods. Finally, ethidium bromide/acridine orange (EB/AO) fluorescent stain was applied to the cells in the 8-chamber slides after they were incubated with the testing agents for 2 hours to detect live and dead cells. The observations were tabulated and analyzed statistically. RESULTS: QMix™ exposure resulted in a significantly higher percentage of cell viability than NaOCl in the MTT and alamarBlue assays at three time points compared to the control. The SEM analysis demonstrated minimal morphological changes associated with cells that were exposed to the QMix™ solution, with little shrinkage and fragmentation of the cell wall. The live/dead analysis showed that the number of live cells after exposure to QMix™ was similar to that of the untreated control. No cell structure could be observed with the NaOCl group, indicating cell lysis. CONCLUSION: Both the QMix™ and NaOCl solutions were toxic to human bone marrow MSCs. Each solution might have induced cell death in a different way as evidenced in the cell viability, SEM and fluorescent studies. The slower cell death induced by QMix™ might therefore be less aggressive and more acceptable to living tissues.


Assuntos
Biguanidas/toxicidade , Células-Tronco Mesenquimais/efeitos dos fármacos , Polímeros/toxicidade , Irrigantes do Canal Radicular/toxicidade , Laranja de Acridina , Técnicas de Cultura de Células , Morte Celular/efeitos dos fármacos , Linhagem Celular , Membrana Celular/efeitos dos fármacos , Forma Celular/efeitos dos fármacos , Sobrevivência Celular/efeitos dos fármacos , Corantes , Etídio , Corantes Fluorescentes , Humanos , Microscopia Eletrônica de Varredura , Oxazinas , Hipoclorito de Sódio/toxicidade , Sais de Tetrazólio , Tiazóis , Fatores de Tempo , Xantenos
6.
J Contemp Dent Pract ; 15(4): 473-81, 2014 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-25576116

RESUMO

AIM: To evaluate and compare the cytotoxicity of various concentrations of sodium hypochlorite on immortalized human bone marrow mesenchymal stem cells (MSCs). MATERIALS AND METHODS: The 5.25 percent sodium hypochlo-rite (NaOCl) at concentrations of 0.5, 0.1, 0.025, 0.0125, and 0.005 mg/ml were used to assess the cytotoxic effect on MSCs. Immortalized human bone marrow mesenchymal stem cells (hTERT-MSCs) were exposed to NaOCl at 5 different concentrations. Cell viability was assessed by 3-(4, 5-dimethylthiazol-2-yl)-2,5-diphenyltetrazolium bromide (MTT) and alamarBlue assays. The cell morphology changes were assessed with scanning electron microscopy (SEM) after exposure to 2, 4, and 24 hour incubation. The ethidium bromide/acridine orange (EB/ AO) fuorescent stain was applied to the cells in the 8-chamber slides after they were incubated with the testing agents for 2 and 4 hours to detect live and dead cells. The observations were quantitatively and qualitatively analyzed. RESULTS: The cell viability study using MTT assay and AB assay showed significant reduction with varying concentration at 2 and 4 hours incubation period. The cell viability decreased with the higher percentage of NaOCl. The exposure time also revealed an inverse relation to the cell viability. The SEM analysis showed reduction in the number of cells and morphological alterations with 0.5 mg/ml at 2 and 4 hours compared to 0.025 mg/ml NaOCl. Destruction of the cells with structural alterations and lysis was evident under fuorescence microscope when the cells were exposed to 0.5 mg/ml NaOCl. CONCLUSION: Within the limitations of this in vitro study it can be concluded that NaOCl is toxic to the human bone marrow MSCs. The cell lysis was evident with higher concentration of sodium hypochlorite. From the observations, it can be concluded that a lower concentration of NaOCl may be used as endodontic irrigant due to its cytotoxic properties. Further studies are mandatory to evolve a consensus on the optimal concentration of sodium hypochlorite to be used as endodontic irrigant.


Assuntos
Células-Tronco Mesenquimais/efeitos dos fármacos , Irrigantes do Canal Radicular/toxicidade , Hipoclorito de Sódio/toxicidade , Laranja de Acridina , Técnicas de Cultura de Células , Morte Celular , Linhagem Celular , Forma Celular/efeitos dos fármacos , Sobrevivência Celular/efeitos dos fármacos , Corantes , Etídio , Corantes Fluorescentes , Humanos , Indicadores e Reagentes , Teste de Materiais , Microscopia Eletrônica de Varredura , Oxazinas , Irrigantes do Canal Radicular/administração & dosagem , Hipoclorito de Sódio/administração & dosagem , Sais de Tetrazólio , Tiazóis , Fatores de Tempo , Xantenos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA