1.
J Appl Clin Med Phys ; 22(4): 193-201, 2021 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-33780142

RESUMO

PURPOSE: Patient-Specific Quality Assurance (PSQA) measurement analysis depends on generating metrics representative of calculation and measurement agreement. Considering the heightened capability of discrete spot scanning protons to modulate individual dose voxels, a dose plane comparison approach that maintained all of the capabilities of the well-established γ test, but that also provided a more intuitive error parameterization, was desired. METHODS: Analysis was performed for 300 dose planes compared by searching all calculated points within a fixed radius around each measured pixel to determine the dose deviation. Dose plane agreement is reported as the dose difference minimum (DDM) within an empirically established search radius: ΔDmin(r). This per-pixel metric is aggregated into a histogram binned by dose deviation. Search-radius criteria were based on a weighted-beamlet 3σ spatial deviation from imaging isocenter. Equipment setup error was mitigated during analysis using tracked image registration, ensuring beamlet deviations to be the dominant source of spatial error. The percentage of comparison points with <3% dose difference determined pass rate. RESULTS: The mean beamlet radial deviation was 0.38mm from x-ray isocenter, with a standard deviation of 0.19mm, such that 99.9% of relevant pencil beams were within 1 mm of nominal. The dose-plane comparison data showed no change in passing rate between a 3%/1mm ΔDmin(r) analysis (97.6 +/- 3.6%) and a 3%/2mm γ test (97.7 +/- 3.2%). CONCLUSIONS: PSQA dose-comparison agreements corresponding to a search radius outside of machine performance limits are likely false positives. However, the elliptical shape of the γ test is too dose-restrictive with a spatial-error threshold set at 1 mm. This work introduces a cylindrical search shape, proposed herein as more relevant to plan quality, as part of the new DDM planar-dose comparison algorithm. DDM accepts all pixels within a given dose threshold inside the search radius, and carries forward plan-quality metrics in a straightforward manner for evaluation.


Assuntos
Terapia com Prótons , Prótons , Algoritmos , Humanos , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador
2.
Phys Imaging Radiat Oncol ; 8: 28-32, 2018 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-33458413

RESUMO

BACKGROUND AND PURPOSE: Intensity modulated proton therapy (IMPT) allows for modulation parameterized for individual beamlets by position, intensity, and depth. This modulation capability is ideally suited for sparing organs at risk intermediate of the radiation target, such as hippocampal volumes within the whole brain. This work compared IMPT relative to volumetric modulated arc therapy (VMAT) during hippocampal avoidance whole brain radiation therapy (HA WBRT). MATERIALS AND METHODS: Ten adult and ten pediatric patients previously treated for central nervous system malignancies were identified. IMPT and VMAT treatment plans employing HA WBRT were generated for each patient, delivering 30 GyE (Gray Equivalent) in 10 fractions for adults and 36 GyE in 20 fractions for pediatrics. Dose indices, including dose volume histogram metrics and homogeneity index HI = [D5% - D95%]/[Dmean] × 100, were used to assess plan quality and describe target coverage and normal-tissue sparing. RESULTS: IMPT offered significant benefits relative to VMAT for hippocampal sparing. Hippocampal mean dose was reduced from 13.7 ±â€¯0.8 Gy with VMAT to 5.4 ±â€¯0.3 GyE using IMPT for pediatrics, and was reduced from 11.7 ±â€¯0.9 Gy with VMAT to 4.4 ±â€¯0.2 GyE using IMPT for adults. IMPT similarly lowered left hippocampal mean dose. Dose to 95% of the clinical target volume was statistically equivalent for both groups; however IMPT reduced the homogeneity index by roughly half. CONCLUSION: This manuscript demonstrates that HA IMPT can match or exceed dosimetric benefits offered with modulated X-rays. Inclusion of IMPT in future prospective studies is warranted.

3.
Med Phys ; 44(9): 4409-4414, 2017 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-28665529

RESUMO

PURPOSE: To implement and evaluate a novel and fast method for proton range verification by using a planar scintillator and step wedge. METHODS: A homogenous proton pencil beam plan with 35 energies was designed and delivered to a 2D flat scintillator with a step wedge. The measurement was repeated 15 times (3 different days, 5 times per day). The scintillator image was smoothed, the Bragg peak and distal fall off regions were fitted by an analytical equation, and the proton range was calculated using simple trigonometry. The accuracy of this method was verified by comparing the measured ranges to those obtained using an ionization chamber and a scanning water tank, the gold standard. The reproducibility was evaluated by comparing the ranges over 15 repeated measurements. The sensitivity was evaluated by delivering to same beam to the system with a film inserted under the wedge. RESULTS: The range accuracy of all 35 proton energies measured over 3 days was within 0.2 mm. The reproducibility in 15 repeated measurements for all 35 proton ranges was ±0.045 mm. The sensitivity to range variation is 0.1 mm for the worst case. This efficient procedure permits measurement of 35 proton ranges in less than 3 min. The automated data processing produces results immediately. The setup of this system took less than 5 min. The time saving by this new method is about two orders of magnitude when compared with the time for water tank range measurements. CONCLUSIONS: A novel method using a scintillator with a step wedge to measure the proton range was implemented and evaluated. This novel method is fast and sensitive, and the proton range measured by this method was accurate and highly reproducible.


Assuntos
Prótons , Dosagem Radioterapêutica , Humanos , Reprodutibilidade dos Testes , Água
4.
Ann Thorac Surg ; 93(3): 984-5, 2012 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-22364994

RESUMO

Infection of a prosthetic graft after replacement of the ascending aorta is an uncommon but life-threatening complication of surgery. We report the use of antibiotic-impregnated calcium sulfate beads in a patient with ascending aortic graft infection to provide localized, high-dose therapy to the infected region. Perigraft placement of antibiotic beads provides an alternative method for the treatment of aortic graft infection.


Assuntos
Antibacterianos/administração & dosagem , Aorta/cirurgia , Prótese Vascular/efeitos adversos , Portadores de Fármacos , Infecções Relacionadas à Prótese/tratamento farmacológico , Infecções Estafilocócicas/tratamento farmacológico , Tobramicina/administração & dosagem , Vancomicina/administração & dosagem , Idoso , Humanos , Masculino , Microesferas