Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
Ocul Immunol Inflamm ; : 1-8, 2024 Jul 18.
Artigo em Inglês | MEDLINE | ID: mdl-39024467

RESUMO

PURPOSE: To present the outcomes of Ahmed glaucoma valve (AGV) implantation in uveitic glaucoma (UG) in a tertiary eye center in Riyadh, Saudi Arabia. METHODS: A retrospective review of all UG patients who underwent AGV implantation at a single, tertiary care eye center from January 2008 to December 2018. The main outcome measures were change in mean intraocular pressure (IOP), number of antiglaucoma medications, overall success rate in different follow-up periods, complete and qualified success from last follow up, and complications. The success of the treatment was defined as patients achieving intraocular pressure (IOP) levels between 6- and 21-mm Hg with or without additional antiglaucoma medications and/or a minimum of 20% reduction from baseline IOP. RESULTS: The study included 74 patients (86 eyes), with a mean follow-up of 4.9 ± 2.9 years. The mean IOP was 32.2 ± 8.5 mmHg at baseline and 16.3 ± 6.6 mmHg at the last follow-up (p < 0.001). The mean number of antiglaucoma medications decreased from 3.5 ± 0.7 preoperatively to 1.3 ± 1.4 at the last follow-up (p < 0.001). Overall survival rates at 1, 3, 5, and 10 years were 96.5%, 92.7%, 91%, and 56.9%, respectively. Complete and qualified success rates were 37.9% and 48.3% at the end of follow up, respectively. The rate of postoperative complications was 56%, of which 18 eyes (20%) required surgical revision. Bivariate Cox proportional hazards regression analysis did not reveal any factors significantly associated with failure. CONCLUSIONS: AGV is safe and effective in providing intermediate-term IOP control in UG patients. Complications reported in our cohort were mostly transient and conservatively treated.

2.
Eur J Ophthalmol ; : 11206721241261418, 2024 Jun 11.
Artigo em Inglês | MEDLINE | ID: mdl-38860310

RESUMO

PURPOSE: To compare the efficacy and safety of iStent versus Endocyclophotocoagulation (ECP) as an adjunct to cataract surgery by Phacoemulsification for treating glaucoma patients in a tertiary eye center. METHODS: Retrospective study of 67 eyes of 61 patients with glaucoma and cataract who underwent either phaco-ECP or phaco-iStent. Primary efficacy endpoint is the Intraocular pressure (IOP) reduction, while reduction of glaucoma medications is the secondary outcome. In addition to IOP and number of glaucoma medications; visual acuity, degree of disc cupping, safety profiles were all assessed at different intervals up to 12 months. RESULTS: A total of 40 eyes underwent phaco-ECP, and 27 eyes underwent phaco-iStent. Both groups were associated with a significant reduction in the number of glaucoma medications; however phaco-iStent group achieved slightly lower IOP levels than the phaco-ECP group. Furthermore, iStent inject had better control of IOP at the last follow-up compared to first-generation stents. Moreover; 2 or more stents significantly reduced IOP than single stent (p = 0.009 vs. p = 0.618, respectively). Phaco-iStent achieved a better reduction in the number of glaucoma medications for primary open-angle glaucoma (p = 0.007) compared to pseudoexfoliation glaucoma patients (p = 0.084). Complications were seen in 12 eyes (18%), of which five eyes in phaco-ECP (7.4%) and 7 eyes in phaco-iStent (10.4%), majority were mild and treated conservatively. CONCLUSIONS: Both groups had equal efficacy in reducing the IOP. However, phaco-iStent seems superior in reducing the number of glaucoma medications after 1 year of follow-up compared to phaco-ECP, particularly when 2 or more stents are used. Both groups showed an overall good safety profile.

3.
Am J Ophthalmol Case Rep ; 12: 15-17, 2018 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-30101207

RESUMO

PURPOSE: To report the effectiveness of Goniosynechialysis (GSL) treating elevated intraocular pressure (IOP) in an aphakic eye with peripheral anterior synechiae (PAS) formation after vitrectomy. OBSERVATIONS: A 39-year-old gentleman with history of lamellar keratoplasty for corneal ectasia and blunt trauma to the right eye necessitating vitrectomy and lensectomy presented to our glaucoma unit with a secondary angle closure and an IOP of 50 mmHg. This was successfully treated with GSL and one year after surgery, the patient maintains a normal IOP without the use of medication. CONCLUSIONS AND IMPORTANCE: GSL may successfully restore angle integrity in aphakic patients following vitreoretinal surgery and avoid the need for a glaucoma drainage device.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA