Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 20
Filtrar
1.
Nutrients ; 16(7)2024 Apr 08.
Artigo em Inglês | MEDLINE | ID: mdl-38613123

RESUMO

Nosocomial infections are a frequent and serious problem in extremely low birth weight (ELBW) infants. Donor human milk (DHM) is the best alternative for feeding these babies when mother's own milk (MOM) is not available. Recently, a patented prototype of a High-Temperature Short-Time (HTST) pasteurizer adapted to a human milk bank setting showed a lesser impact on immunologic components. We designed a multicentre randomized controlled trial that investigates whether, in ELBW infants with an insufficient MOM supply, the administration of HTST pasteurized DHM reduces the incidence of confirmed catheter-associated sepsis compared to DHM pasteurized with the Holder method. From birth until 34 weeks postmenstrual age, patients included in the study received DHM, as a supplement, pasteurized by the Holder or HTST method. A total of 213 patients were randomized; 79 (HTST group) and 81 (Holder group) were included in the analysis. We found no difference in the frequency of nosocomial sepsis between the patients of the two methods-41.8% (33/79) of HTST group patients versus 45.7% (37/81) of Holder group patients, relative risk 0.91 (0.64-1.3), p = 0.62. In conclusion, when MOM is not available, supplementing during admission with DHM pasteurized by the HTST versus Holder method might not have an impact on the incidence of catheter-associated sepsis.


Assuntos
Recém-Nascido de Peso Extremamente Baixo ao Nascer , Sepse , Lactente , Recém-Nascido , Humanos , Leite Humano , Temperatura , Suplementos Nutricionais , Sepse/epidemiologia , Sepse/prevenção & controle
2.
An Pediatr (Engl Ed) ; 96(4): 300-308, 2022 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-35523686

RESUMO

INTRODUCTION: In 2017, a worldwide survey was conducted on compliance with the practices promoted by Neo-BFHI (Baby-friendly Hospital Initiative expansion to neonatal wards). OBJECTIVE: To present the results of the Spanish wards that participated in the global survey and compare them with those obtained internationally. MATERIAL AND METHODS: Cross-sectional study through a survey on compliance with the Neo-BFHI ("Three basic principles", "Ten steps adapted to neonatal wards" and "the compliance with the International Code of Marketing of Breast-milk Substitutes" and subsequent relevant World Health Assembly resolutions). Compliance was calculated as the mean in each indicator and a final mean score for each neonatal unit. For the partial and final scores for each country and at the international level, the median was used. All scores ranged between 0 and 100. RESULTS: The response rate in Spain was 90%. The range of the national mean for neonatal wards were from 37 to 99, with no differences in the final score according to the level of care. The global score for Spain (72) is below the international median (77) and this also occurs in 8 of 14 items. The neonatal wards from BFHI designated hospitals, obtained a significantly higher mean global score, and in 9 of 14 items than the non-accredited ones. CONCLUSIONS: Both international and national results indicate an improvement in breast feeding practices in neonatal units. The benefits of the BFHI accreditation of maternity reach neonatal wards. Spain has several key points below the international score.


Assuntos
Aleitamento Materno , Promoção da Saúde , Berçários Hospitalares , Aleitamento Materno/estatística & dados numéricos , Estudos Transversais , Feminino , Promoção da Saúde/métodos , Hospitais , Humanos , Recém-Nascido , Gravidez , Espanha
3.
Lancet Child Adolesc Health ; 6(1): 49-59, 2022 01.
Artigo em Inglês | MEDLINE | ID: mdl-34843669

RESUMO

BACKGROUND: Vancomycin is the most widely used antibiotic for neonatal Gram-positive sepsis, but clinical outcome data of dosing strategies are scarce. The NeoVanc programme comprised extensive preclinical studies to inform a randomised controlled trial to assess optimised vancomycin dosing. We compared the efficacy of an optimised regimen to a standard regimen in infants with late onset sepsis that was known or suspected to be caused by Gram-positive microorganisms. METHODS: NeoVanc was an open-label, multicentre, phase 2b, parallel-group, randomised, non-inferiority trial comparing the efficacy and toxicity of an optimised regimen of vancomycin to a standard regimen in infants aged 90 days or younger. Infants with at least three clinical or laboratory sepsis criteria or confirmed Gram-positive sepsis with at least one clinical or laboratory criterion were enrolled from 22 neonatal intensive care units in Greece, Italy, Estonia, Spain, and the UK. Infants were randomly assigned (1:1) to either the optimised regimen (25 mg/kg loading dose, followed by 15 mg/kg every 12 h or 8 h dependent on postmenstrual age, for 5 ± 1 days) or the standard regimen (no loading dose; 15 mg/kg every 24 h, 12 h, or 8 h dependent on postmenstrual age for 10 ± 2 days). Vancomycin was administered intravenously via 60 min infusion. Group allocation was not masked to local investigators or parents. The primary endpoint was success at the test of cure visit (10 ± 1 days after the end of actual vancomycin therapy) in the per-protocol population, where success was defined as the participant being alive at the test of cure visit, having a successful outcome at the end of actual vancomycin therapy, and not having a clinically or microbiologically significant relapse or new infection requiring antistaphylococcal antibiotics for more than 24 h within 10 days of the end of actual vancomycin therapy. The non-inferiority margin was -10%. Safety was assessed in the intention-to-treat population. This trial is registered at ClinicalTrials.gov (NCT02790996). FINDINGS: Between March 3, 2017, and July 29, 2019, 242 infants were randomly assigned to the standard regimen group (n=122) or the optimised regimen group (n=120). Primary outcome data in the per-protocol population were available for 90 infants in the optimised group and 92 in the standard group. 64 (71%) of 90 infants in the optimised group and 73 (79%) of 92 in the standard group had success at test of cure visit; non-inferiority was not confirmed (adjusted risk difference -7% [95% CI -15 to 2]). Incomplete resolution of clinical or laboratory signs after 5 ± 1 days of vancomycin therapy was the main factor contributing to clinical failure in the optimised group. Abnormal hearing test results were recorded in 25 (30%) of 84 infants in the optimised group and 12 (15%) of 79 in the standard group (adjusted risk ratio 1·96 [95% CI 1·07 to 3·59], p=0·030). There were six vancomycin-related adverse events in the optimised group (one serious adverse event) and four in the standard group (two serious adverse events). 11 infants in the intention-to-treat population died (six [6%] of 102 infants in the optimised group and five [5%] of 98 in the standard group). INTERPRETATION: In the largest neonatal vancomycin efficacy trial yet conducted, no clear clinical impact of a shorter duration of treatment with a loading dose was demonstrated. The use of the optimised regimen cannot be recommended because a potential hearing safety signal was identified; long-term follow-up is being done. These results emphasise the importance of robust clinical safety assessments of novel antibiotic dosing regimens in infants. FUNDING: EU Seventh Framework Programme for research, technological development and demonstration.


Assuntos
Antibacterianos , Estudos de Equivalência como Asunto , Unidades de Terapia Intensiva Neonatal , Sepse/tratamento farmacológico , Vancomicina , Antibacterianos/administração & dosagem , Antibacterianos/efeitos adversos , Europa (Continente) , Humanos , Lactente , Recém-Nascido , Infusões Intravenosas , Sepse/mortalidade , Espanha , Fatores de Tempo , Resultado do Tratamento , Reino Unido , Vancomicina/administração & dosagem , Vancomicina/efeitos adversos
4.
J Hum Lact ; 37(4): 639-648, 2021 11.
Artigo em Inglês | MEDLINE | ID: mdl-34374323

RESUMO

BACKGROUND: Adherence to the Ten Steps of the Baby-Friendly Hospital Initiative has been shown to have a protective role for the initiation and maintenance of breastfeeding. RESEARCH AIMS: (1) To determine the breastfeeding rate during the first 6 months of life in children of mothers diagnosed with COVID-19 infection at the time of birth; and (2) to assess the possible influence of being born in a center with Baby-Friendly Hospital Initiative accreditation. METHODS: This was a two-group comparative longitudinal observational study of infants born to mothers with COVID-19 at the time of birth, between March 13-May 31, 2020 (the first wave of the pandemic) in Spain. Fourteen Spanish hospitals participated, five (35.7%) were Baby-Friendly Hospital Initiative accredited. Type of feeding was assessed prospectively at discharge, 1, 3, and 6 months of age. A total of 248 newborns were included in the study. RESULTS: A total of 117 (47.3%) newborns were born in Baby-Friendly Hospital Initiative (BFHI) accredited centers. These centers applied skin-to-skin contact with greater probability (OR = 1.9; 95% CI [1.18, 3.29]) and separated the newborns from their mothers less frequently (OR = 0.46; 95% CI [0.26, 0.81]) than non-accredited centers. No differences were observed in relation to the presence of a companion at the time of birth. At discharge, 49.1% (n = 57) of newborns born in BFHI-accredited centers received exclusive breastfeeding versus 35.3% (n = 46) in non-accredited centers (p = .03). No differences were observed in breastfeeding rates throughout follow-up. CONCLUSIONS: The exclusive breastfeeding rate at discharge in children of mothers with COVID-19 infection at birth was higher in Baby-Friendly Hospital Initiative accredited centers, which most frequently applied skin-to-skin contact at birth as well as rooming-in.


Assuntos
Aleitamento Materno , COVID-19 , Criança , Feminino , Promoção da Saúde , Hospitais , Humanos , Lactente , Recém-Nascido , Mães , Pandemias , SARS-CoV-2 , Espanha/epidemiologia
5.
An Pediatr (Engl Ed) ; 2021 May 24.
Artigo em Espanhol | MEDLINE | ID: mdl-34045162

RESUMO

INTRODUCTION: In 2017, a worldwide survey was conducted on compliance with the practices promoted by Neo-BFHI (Baby-friendly Hospital Initiative expansion to neonatal wards). OBJECTIVE: Present the results of the Spanish wards that participated in the global survey and compare them with those obtained internationally. MATERIAL AND METHODS: Cross-sectional study through a survey on compliance with the Neo-BFHI ("Three basic principles", "Ten steps adapted to neonatal wards" and "the compliance with the International Code of Marketing of Breast-milk Substitutes" and subsequent relevant World Health Assembly resolutions). Compliance was calculated as the mean in each indicator and a final mean score for each neonatal unit. For the partial and final scores for each country and at the international level, the median was used. All score ranged between 0 and 100. RESULTS: The response rate in Spain was 90%. The range of the national mean for neonatal wards were from 37 to 99, with no differences in the final score according to the level of care. The global score for Spain (72) is below the international median (77) and this also occurs in 8 of 14 items. The neonatal wards from BFHI designated hospitals, obtained a significantly higher mean global score, and in 9 of 14 items than the non-accredited ones. CONCLUSIONS: Both international and national results indicate an improvement in breastfeeding practices in neonatal units. The benefits of the BFHI accreditation of maternity reach neonatal wards. Spain has several key points below the international score.

6.
Front Pediatr ; 8: 580584, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-33194912

RESUMO

Objective: Coronavirus disease 2019 (COVID-19) cases caused by the severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) continue to increase worldwide. Although some data from pediatric series are available, more evidence is required, especially in neonates, a group with specific characteristics that deserve special attention. This study aimed to describe general and clinical characteristics, management, and treatment of postnatal-acquired (community and nosocomial/hospital-acquired) COVID-19 neonatal cases in Spain. Methods: This was a national prospective epidemiological study that included cases from a National Registry supported by the Spanish Society of Neonatology. Neonates with postnatal SARS-CoV-2 infection were included in this study. General data and infection-related information (mode and source of transmission, age at diagnosis, clinical manifestations, need for hospitalization, admission unit, treatment administered, and complementary studies performed, hospital stay associated with the infection) were collected. Results: A total of 40 cases, 26 community-acquired and 14 nosocomial were registered. Ten were preterm newborns (2 community-acquired and 8 nosocomial COVID-19 cases). Mothers (in both groups) and healthcare workers (in nosocomial cases) were the main source of infection. Hospital admission was required in 22 community-acquired cases [18 admitted to the neonatal intermediate care unit (NIMCU) and 4 to the neonatal intensive care unit (NICU)]. Among nosocomial COVID-19 cases (n = 14), previously admitted for other reasons, 4 were admitted to the NIMCU and 10 to the NICU. Ten asymptomatic patients were registered (5 in each group). In the remaining cases, clinical manifestations were generally mild in both groups, including upper respiratory airways infection, febrile syndrome or acute gastroenteritis with good overall health. In both groups, most severe cases occurred in preterm neonates or neonates with concomitant pathologies. Most of the cases did not require respiratory support. Hydroxychloroquine was administered to 4 patients in the community-acquired group and to 2 patients in the nosocomial group. Follow-up after hospital discharge was performed in most patients. Conclusions: This is the largest series of COVID-19 neonatal cases in Spain published to date. Although clinical manifestations were generally mild, prevention, treatment, and management in this group are essential.

7.
Acta Paediatr ; 109(11): 2302-2308, 2020 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-32649784

RESUMO

AIM: Our aim was to describe the clinical features of mothers infected with COVID-19 and examine any potential vertical mother to newborn transmission. We also assessed how effective the discharge recommendations were in preventing transmission during the first month of life. METHODS: This multicentre descriptive study involved 16 Spanish hospitals. We reviewed the medical records of 42 pregnant women diagnosed with COVID-19 from March 13, 2020, to March 29, 2020, when they were in their third trimester of pregnancy. They and their newborn infants were monitored until the infant was 1 month old. RESULTS: Over half (52.4%) of the women had a vaginal delivery. The initial clinical symptoms were coughing (66.6%) and fever (59.5%), and one mother died due to thrombo-embolic events. We admitted 37 newborn infants to the neonatal unit (88%), and 28 were then admitted to intermediate care for organisational virus-related reasons. No infants died, and no vertical transmission was detected during hospitalisation or follow-up. Only six were exclusively breastfed at discharge. CONCLUSION: There was no evidence of COVID-19 transmission in any of the infants born to COVID-19 mothers, and the post-discharge advice seemed effective. The measures to avoid transmission appeared to reduce exclusive breastfeeding at discharge.


Assuntos
COVID-19/transmissão , Transmissão Vertical de Doenças Infecciosas , Adulto , COVID-19/prevenção & controle , Feminino , Humanos , Recém-Nascido , Masculino , Gravidez , Estudos Retrospectivos
9.
PLoS One ; 15(5): e0233528, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32437468

RESUMO

BACKGROUND & AIM: Worldwide, measures are being implemented to eradicate hepatitis B (HBV) and C (HCV) viruses, which can be transmitted from the mother during childbirth. This study aims to determine the prevalence of HBV and HCV in pregnant women in Spain, focusing on country of origin, epidemiological factors and risk of vertical transmission (VT). METHODOLOGY: Multicentre open-cohort study performed during 2015. HBV prevalence was determined in 21870 pregnant women and HCV prevalence in 7659 pregnant women. Epidemiological and risk factors for VT were analysed in positive women and differences between HBV and HCV cases were studied. RESULTS: HBV prevalence was 0.42% (91/21870) and HCV prevalence was 0.26% (20/7659). Of the women with HBV, 65.7% (44/67) were migrants. The HBV transmission route to the mother was unknown in 40.3% of cases (27/67) and VT in 31.3% (21/67). Among risk factors for VT, 67.7% (42/62) of the women had viraemia and 14.5% (9/62) tested HBeAg-positive. All of the neonates born to HBV-positive mothers received immunoprophylaxis, and none contracted infection by VT. In 80% (16/20) of the women with HCV, the transmission route was parenteral, and nine were intravenous drug users. Viraemia was present in 40% (8/20) of the women and 10% (2/20) were HIV-coinfected. No children were infected. Women with HCV were less likely than women with HBV to breastfeed their child (65% vs. 86%). CONCLUSIONS: The prevalences obtained in our study of pregnant women are lower than those previously documented for the general population. Among the women with HBV, the majority were migrants and had a maternal family history of infection, while among those with HCV, the most common factor was intravenous drug use. Despite the risk factors observed for VT, none of the children were infected. Proper immunoprophylaxis is essential to prevent VT in children born to HBV-positive women.


Assuntos
Hepatite B/epidemiologia , Hepatite C/epidemiologia , Complicações Infecciosas na Gravidez/epidemiologia , Estudos de Coortes , Feminino , Hepacivirus/isolamento & purificação , Hepatite B/transmissão , Vírus da Hepatite B/isolamento & purificação , Hepatite C/transmissão , Humanos , Transmissão Vertical de Doenças Infecciosas , Gravidez , Fatores de Risco , Estudos Soroepidemiológicos , Espanha
12.
Acta Paediatr ; 109(7): 1361-1368, 2020 07.
Artigo em Inglês | MEDLINE | ID: mdl-31799756

RESUMO

AIM: To assess, at national level, the implementation of eight principles for infant- and family-centred developmental care (IFCDC) in neonatal units. A European expert group established eight 'Principles of care' in 2018 that define neurodevelopmental and family-centred care. METHODS: The implementation of each principle was assessed by a survey sent to level-III Spanish units. A principle was considered to be implemented if all answers to the principle-associated questions were positive. RESULTS: The response rate was 84.5% (65/77). No unit had implemented eight principles. Principle 1 (free parental access) was implemented in 21.5% of the centres; Principle 2 (psychological support) 40%; Principle 3 (pain management) 7.7%; Principle 4 (environmental influences) 29%; Principle 5 (postural support) 84.6%; Principle 6 (kangaroo-care) 67.7%; Principle 7 (breastfeeding) 23% and Principle 8 (sleep protection) in 46%. In units attending ≥50 very low birth weight (VLBW) infants, four or more principles had been implemented in 31% vs 13% <50 VLBW neonates (odds ratio 3.0 CI 95% 0.9-10.1, P .07). CONCLUSION: The principle with the highest implementation was related to newborn body positioning. Pain management was the principle with lowest implementation. More principles for IFCDC tend to be implemented in units providing care for a higher number of VLBW infants.


Assuntos
Recém-Nascido de muito Baixo Peso , Unidades de Terapia Intensiva Neonatal , Aleitamento Materno , Criança , Feminino , Humanos , Cuidado do Lactente , Recém-Nascido , Pais
14.
J Hum Lact ; 32(4): 613-626, 2016 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-27492981

RESUMO

BACKGROUND: The Baby-Friendly Hospital Initiative (BFHI) has a positive effect on breastfeeding in maternity wards; however, few studies have examined to what degree it affects care in neonatal intensive care units (NICUs). Recently, the BFHI has been adapted to the NICUs (Neo-BFHI). OBJECTIVE: This study aimed to compare breastfeeding support in Spanish NICUs in hospitals with BFHI accreditation or in the process of being accredited (group 1) with NICUs in hospitals that have not yet begun this initiative (group 2). METHODS: A validated questionnaire on breastfeeding support was distributed to level II and III NICUs in Spanish public hospitals. A univariate analysis and an analysis adjusted for the number of beds in NICUs were conducted. The results of the analysis of 36 breastfeeding support measures are presented in accordance with the Ten Steps to Successful Breastfeeding adapted to NICUs. RESULTS: Of the 141 participating NICUs, 129 (91%) responded to the questionnaire: 38 NICUs from group 1 and 91 NICUs from group 2. Group 1 had implemented a higher number of breastfeeding support measures than group 2. There were significant differences in 18 measures related to steps 2, 4, 5, 7, and 8 of the Neo-BFHI. In addition, a comparison of NICUs in hospitals with full accreditation (7 of 129) with those in group 2 revealed significant differences in 7 measures pertaining to steps 2, 5, 8, and 9. CONCLUSION: The Spanish NICUs in hospitals with BFHI accreditation or in the process of being accredited have better implementation of practices to promote and support breastfeeding.


Assuntos
Aleitamento Materno/métodos , Promoção da Saúde/métodos , Hispânico ou Latino/estatística & dados numéricos , Acreditação/estatística & dados numéricos , Aleitamento Materno/estatística & dados numéricos , Promoção da Saúde/estatística & dados numéricos , Hispânico ou Latino/psicologia , Hospitais/normas , Hospitais/estatística & dados numéricos , Humanos , Unidades de Terapia Intensiva Neonatal/organização & administração , Unidades de Terapia Intensiva Neonatal/estatística & dados numéricos , Cuidado Pós-Natal/métodos , Cuidado Pós-Natal/estatística & dados numéricos , Inquéritos e Questionários
15.
Breastfeed Med ; 11(2): 91-3, 2016 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-26800010

RESUMO

OBJECTIVE: Although under certain circumstances it is necessary to express milk, there are not many recommendations about the ideal storage conditions for human milk. The objectives of this study were to analyze the effects on Dornic acidity of frozen storage at -20 °C in three types of milk: raw donor milk, mother's own raw milk, and pasteurized donor milk. METHODS: Forty-three samples of raw donor milk, 40 samples of pasteurized donor milk, and 16 samples of mother's own milk were analyzed. Dornic acidity was measured at time 0, before freezing. The remaining aliquots were frozen and analyzed after 1, 2, 3, and 4 weeks and after 2 and 3 months. RESULTS: In raw donor milk, the median acidity at the start was 3 °D (interquartile range [IQR] 2-3 °D); after 3 months, it was 5 °D (IQR 3-7 °D), with a significant increase in acidity after the second week. In mother's own milk, the mean acidity at the start was 3 °D (IQR 2-4 °D) and 7 °D (IQR 4-8 °D) at 3 months. The increase was significant after the third week. In pasteurized donor milk, the mean acidity was 3 °D (IQR 2-3 °D) at the start and 2 °D (IQR 2-3 °D) at the end. When comparing the three types of milk, there were significant differences from the first week between the two types of raw milk and the pasteurized milk (p < 0.01), but not between the two raw milks (p = 0.77). CONCLUSIONS: Dornic acidity in unpasteurized milk significantly increases with the duration of freezing, probably due to the action of lipases, which is lost with pasteurization. It would be advisable to reduce the length of freezing time for unpasteurized milk.


Assuntos
Bactérias Aeróbias/crescimento & desenvolvimento , Congelamento , Ácido Láctico/metabolismo , Leite Humano/química , Pasteurização , Contagem de Colônia Microbiana , Feminino , Conservação de Alimentos , Humanos , Bancos de Leite Humano , Proteínas do Leite/metabolismo , Leite Humano/microbiologia , Mães , Fatores de Tempo
16.
An Pediatr (Barc) ; 85(1): 26-33, 2016 Jul.
Artigo em Espanhol | MEDLINE | ID: mdl-26458522

RESUMO

INTRODUCTION: There is currently no unified policy on either breastfeeding support or enteral nutrition practices, as regards human milk (HM) in pre-term newborns. The aim of this study was to describe breastfeeding support measures, as well as the use of HM in very preterm infants in Spanish public hospitals. METHOD: A questionnaire on enteral feeding practices was distributed. Data were analysed from units caring for newborns less than 32 weeks or 1,500g. A univariate analysis was performed comparing level ii and iii care units. RESULTS: There was a 91% response rate. A total of 93 units cared for infants less than 32 weeks or 1,500g (17 level ii and 76 level iii), and 49% of the units recorded the breastfeeding rate on discharge. Around 75% (70/93) had a guideline on managing HM (level iii 81 vs. level ii 47%, P=.002), and 25% had access to donor human milk. Just under half (46%) started trophic feeding in the first 6h. Target enteral feeding volume in stable preterm infants was ≥ 180ml/kg/day in 89% of the units (level iii 93% vs. level ii 70%, P =.017). HM fortifier was used in 96% of the units. In 92%, it was added when the required enteral volume was tolerated. In 59% of the units, adjustments in the quantity of fortifier were made according to weight, and in 36%, it depended on analytical criteria. Some units (9%) used pure protein fortifier. CONCLUSIONS: There is a marked variability in breastfeeding support measures and in feeding practices of preterm infants in Spanish neonatal units.


Assuntos
Aleitamento Materno , Nutrição Enteral , Comportamento Alimentar , Leite Humano , Humanos , Recém-Nascido , Recém-Nascido Prematuro , Padrões de Prática Médica , Espanha , Inquéritos e Questionários
17.
J Hum Lact ; 30(4): 436-41, 2014 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-25122692

RESUMO

BACKGROUND: Substantial fat loss may occur during continuous feeding of human milk (HM). A decrease of fat loss has been described following homogenization. Well-established methods of homogenization of HM for routine use in the neonatal intensive care unit (NICU) would be desirable. OBJECTIVE: We compared the loss of fat based on the use of 3 different methods for homogenizing thawed HM during continuous feeding. METHODS: Sixteen frozen donor HM samples were thawed, homogenized with ultrasound and separated into 3 aliquots ("baseline agitation," "hourly agitation," and "ultrasound"), and then frozen for 48 hours. Aliquots were thawed again and a baseline agitation was applied. Subsequently, aliquots baseline agitation and hourly agitation were drawn into a syringe, while ultrasound was applied to aliquot ultrasound before it was drawn into a syringe. The syringes were loaded into a pump (2 mL/h; 4 hours). At hourly intervals the hourly agitation infusion was stopped, the syringe was disconnected and gently shaken. During infusion, samples from the 3 groups were collected hourly for analysis of fat and caloric content. RESULTS: The 3 groups of homogenization showed similar fat content at the beginning of the infusion. For fat, mean (SD) hourly changes of -0.03 (0.01), -0.09 (0.01), and -0.09 (0.01) g/dL were observed for the hourly agitation, baseline agitation, and ultrasound groups, respectively. The decrease was smaller for the hourly agitation group (P < .001). CONCLUSION: When thawed HM is continuously infused, a smaller fat loss is observed when syringes are agitated hourly versus when ultrasound or a baseline homogenization is used.


Assuntos
Nutrição Enteral/métodos , Lipídeos/análise , Leite Humano/química , Feminino , Congelamento , Humanos , Recém-Nascido , Bombas de Infusão
18.
Early Hum Dev ; 90(5): 209-12, 2014 May.
Artigo em Inglês | MEDLINE | ID: mdl-24581867

RESUMO

BACKGROUND: Little is known regarding the effect of the characteristics of donors and their children on the volume of donor milk delivered to a human milk bank (HMB). AIMS: Our study aimed to determine the relationship between different social and demographic variables of donors and their infants with the volume of human milk delivered. METHODS: We included donors accepted at the Hospital Doce de Octubre HMB from January 1st, 2009 until April 31st, 2013, and who had finished their donation. Data of social and demographic characteristics of the donors and their children, and the total volume of DHM given were obtained from our HMB database. Included variables were previous donors, donor age, number of children, place of residence, gestational age of the infant at birth, child's age at the start of the donation, hospital admission, and death of the infant. A linear regression model was used to study the relationship between independent variables that were significant in bivariate analysis and the volume of donated milk. RESULTS: A total of 415 donations from 391 women were included. The median volume of milk delivered was 3.1l (IQR-interquartile range-1.3-8.3l). In the linear regression model, previous donors, smaller gestational age of children, and the start of donation at earlier stages of lactation were associated with a larger quantity of HMB donated (p≤0.001). CONCLUSION: Previous donors, smaller gestational age of children, and the start of donation at earlier stages of lactation are associated with a larger quantity of milk donated to the HMB.


Assuntos
Extração de Leite , Bancos de Leite Humano , Leite Humano , Adulto , Aleitamento Materno , Feminino , Idade Gestacional , Humanos , Lactação
20.
Int Breastfeed J ; 5: 4, 2010 Mar 08.
Artigo em Inglês | MEDLINE | ID: mdl-20211005

RESUMO

BACKGROUND: Donor human milk banks are much more than simple centers for collection, storage, processing, and distribution of donor human milk, as they cover other aspects and represent a real opportunity to promote and support breastfeeding. The aim of our study is to assess the impact that opening a human milk bank has had on the proportion of infants receiving exclusive breast milk at discharge and other aspects related to feeding children with birth weight < or = 1500 g or < 32 weeks gestation admitted to the neonatal unit. METHODS: The study included babies of < or = 1500 g or < 32 weeks gestation. Fifty infants born from February to July in 2006, before the opening of the human milk bank, and 54 born from February to July in 2008, after its opening, met inclusive criteria. We collected data about days of hospital stay, hours of life when feeding was started, hours of life when full enteral feeding was attained, the type of milk received during admission, and the type of feeding on discharge. RESULTS: Children born in 2008 commenced feeding 16 hours earlier than those born in 2006 (p = 0.00). The proportion of infants receiving exclusive breast milk at discharge was 54% in 2006 and 56% in 2008 (p = 0.87). The number of days they received their mother's own milk during the first 28 days of life was 24.2 days in 2006, compared to 23.7 days in 2008 (p = 0.70). In 2006, 60% of infants received infant formula at least once in the first 28 days of life, compared to 37% in 2008 (p = 0.01). CONCLUSIONS: The opening of a donor human milk bank in a neonatal unit did not reduce the proportion of infants exclusively fed with breast milk at discharge, but did reduce the proportion of infants that received infant formula during the first four weeks of life. Also, having donor human milk available enables commencement of enteral feeding earlier.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA