Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
Luminescence ; 39(7): e4819, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38956814

RESUMO

Mefenamic acid, renowned for its analgesic properties, stands as a reliable choice for alleviating mild to moderate pain. However, its versatility extends beyond pain relief, with ongoing research unveiling its promising therapeutic potential across diverse domains. A straightforward, environmentally friendly, and sensitive spectrofluorometric technique has been developed for the precise quantification of the analgesic medication, mefenamic acid. This method relies on the immediate reduction of fluorescence emitted by a probe upon interaction with varying concentrations of the drug. The fluorescent probe utilized, N-phenyl-1-naphthylamine (NPNA), was synthesized in a single step, and the fluorescence intensities were measured at 480 nm using synchronous fluorescence spectroscopy with a wavelength difference of 200 nm. Temperature variations and lifetime studies indicated that the quenching process was static. The calibration curve exhibited linearity within the concentration range of 0.50-9.00 µg/mL, with a detection limit of 60.00 ng/mL. Various experimental parameters affecting the quenching process were meticulously examined and optimized. The proposed technique was successfully applied to determine mefenamic acid in pharmaceutical formulations, plasma, and urine, yielding excellent recoveries ranging from 98% to 100.5%. The greenness of the developed method was evaluated using three metrics: the Analytical Eco-scale, AGREE, and the Green Analytical Procedure Index.


Assuntos
Corantes Fluorescentes , Ácido Mefenâmico , Espectrometria de Fluorescência , Ácido Mefenâmico/análise , Ácido Mefenâmico/química , Ácido Mefenâmico/urina , Corantes Fluorescentes/química , Corantes Fluorescentes/síntese química , Humanos , Estrutura Molecular , Preparações Farmacêuticas/química , Preparações Farmacêuticas/análise , Limite de Detecção
2.
Sci Rep ; 13(1): 20187, 2023 11 18.
Artigo em Inglês | MEDLINE | ID: mdl-37980444

RESUMO

Analysis of drugs clinically and their identification in biological samples are of utmost importance in the process of therapeutic drug monitoring, also in pharmacokinetic investigations and tracking of illicit medications. These investigations are carried out using a variety of analytical methods, including potentiometric electrodes. Potentiometric electrodes are a wonderful solution for researchers because they outperform other methods in terms of sustainability, greenness, and cost effectiveness. In the current study, ion-selective potentiometric sensors were assembled for the aim of quantification of the anticancer drug Letrozole (LTZ). The first step was fabrication of a conventional sensor based on the formation of stable host-guest inclusion complex between the cationic drug and 4-tert-butylcalix-8-arene (TBCAX-8). Two additional sensors were prepared through membrane modification with graphene nanocomposite (GNC) and polyaniline (PANI) nanoparticles. Linear responses of 1.00 × 10-5-1.00 × 10-2, 1.00 × 10-6-1.00 × 10-2 and 1.00 × 10-8-1.00 × 10-3 with sub-Nernstian slopes of 19.90, 20.10 and 20.30 mV/decade were obtained for TBCAX-8, GNC, and PANI sensors; respectively. The developed sensors were successful in determining the drug LTZ in bulk powder and dosage form. PANI modified sensor was used to determine LTZ in human plasma with recoveries ranging from 88.00 to 96.30%. IUPAC recommendations were followed during the evaluation of the electrical performance of the developed sensors. Experimental conditions as temperature and pH were studied and optimized. Analytical Eco-scale and Analytical GREEness metric were adopted as the method greenness assessment tools.


Assuntos
Grafite , Eletrodos Seletivos de Íons , Humanos , Letrozol , Eletrodos , Potenciometria/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA