Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 31
Filtrar
2.
Cardiol Young ; 34(1): 228-231, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-38073568

RESUMO

Amplatzer Vascular Plug IV (Abbott, USA) is usually used for the occlusion of abnormal tortuous vessels and has not been tried for the transcatheter closure of perimembranous ventricular septal defects with wind-sock morphology. Here, we report on three successful cases of perimembranous ventricular septal defect transcatheter closure using Amplatzer Vascular Plug IV. We did not observe residual shunting or new onset of complications during follow up. These preliminary positive results advocate the application and suitability of Amplatzer Vascular Plug IV for closing wind-sock-like perimembranous ventricular septal defects.


Assuntos
Comunicação Interventricular , Dispositivo para Oclusão Septal , Humanos , Seguimentos , Resultado do Tratamento , Vento , Cateterismo Cardíaco/métodos , Comunicação Interventricular/diagnóstico por imagem , Comunicação Interventricular/cirurgia
4.
Cardiol Young ; 33(11): 2243-2251, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-36651340

RESUMO

BACKGROUND: The objective was to study the ductus arteriosus morphology in duct-dependent pulmonary circulation and its pattern in different ventricle morphology using CT angiography. METHOD: From January 2013 to December 2015, patients aged 6 months and below with duct-dependent pulmonary circulation underwent CT angiography to delineate the ductus arteriosus origin, tortuosity, site of insertion, and pulmonary artery anatomy. The ductus arteriosus were classified into type I, IIa, IIb, and III based on its site of origin, either from descending aorta, distal arch, proximal arch, or subclavian artery, respectively. RESULTS: A total of 114 patients and 116 ductus arteriosus (two had bilateral ductus arteriosus) were analysed. Type I, IIa, IIb, and III ductus arteriosus were seen in 13 (11.2 %), 71 (61.2%), 21 (18.1%), and 11 (9.5%), respectively. Tortuous ductus arteriosus was found in 38 (32.7%), which was commonly seen in single ventricular lesions. Ipsilateral and bilateral branch pulmonary artery stenosis was seen in 68 (59.6%) and 6 (5.3%) patients, respectively. The majority of patients with pulmonary atresia intact ventricular septum had type I (54.4%) and non-tortuous ductus arteriosus, while those with single and biventricular lesions had type II ductus arteriosus (84.9% and 89.7%, respectively). Type III ductus arteriosus was more common in biventricular lesions (77.8%). CONCLUSIONS: Ductus arteriosus in duct-dependent pulmonary circulation has a diverse morphology with a distinct origin and tortuosity pattern in different types of ventricular morphology. CT may serve as an important tool in case selection and pre-procedural planning for ductal stenting.


Assuntos
Permeabilidade do Canal Arterial , Canal Arterial , Atresia Pulmonar , Humanos , Canal Arterial/diagnóstico por imagem , Circulação Pulmonar , Permeabilidade do Canal Arterial/diagnóstico por imagem , Stents , Angiografia por Tomografia Computadorizada
5.
Cardiol Young ; 33(8): 1359-1366, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-35950412

RESUMO

INTRODUCTION: Current guidelines discourage shunt closure in patients with pulmonary vascular resistance index >8 Wood units x m2. The study examined the long-term outcome of patients over 15 years old, with pulmonary vascular resistance index >8 Wood units x m2 and patent ductus arteriosus. MATERIALS AND METHODS: This was a multi-institutional, retrospective study involving all consecutive patients (>15 years old) with patent ductus arteriosus and severe pulmonary hypertension. Patients who had patent ductus arteriosus closure were divided into the Good (no death or hospital admissions due to worsening pulmonary hypertension) and the Poor Outcome groups and these groups were compared. RESULTS: Thirty-seven patients [male: 9 (24.3%); mean age: 30.49 ± 9.56 years; median follow-up: 3 (IQR: 1.5,10) years] were included from four centers. Twenty-two patients who underwent patent ductus arteriosus closure, 15 (71.4%) had good outcomes while 7 (28.6%) had poor outcomes. Pulmonary vascular resistance index and pulmonary to systemic resistance ratio (Rp:Rs) were lower in the Good Outcome Group (14.35 ± 1.66 Wood units x m2 vs. 20.07 ± 2.44; p = 0.033 and 0.44 ± 0.16 vs. 1.08 ± 1.21; p = 0.042). Haemoglobin concentrations (<14.3 g/dL) were associated with good long-term outcomes in the Closed Group. CONCLUSIONS: Patients with patent ductus arteriosus with severe pulmonary hypertension have a dismal outcome with or without closure. High haemoglobin levels at the time of occlusion predict a worse outcome for patients with patent ductus arteriosus and pulmonary hypertension.


Assuntos
Permeabilidade do Canal Arterial , Hipertensão Pulmonar , Adolescente , Adulto , Humanos , Masculino , Adulto Jovem , Permeabilidade do Canal Arterial/complicações , Permeabilidade do Canal Arterial/cirurgia , Hemoglobinas , Hipertensão Pulmonar/complicações , Estudos Retrospectivos , Resultado do Tratamento
6.
Ann Pediatr Cardiol ; 15(2): 147-153, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36246748

RESUMO

Introduction: Bioresorbable stent has the theoretical advantage in the pediatric age group; however, experience in the literature is very limited. Objectives: This pilot study sought to evaluate the feasibility, safety, and performance of iron bioresorbable scaffold (IBS Angel™) as short-term palliation in lesions with noncomplex patent ductus arteriosus (PDA). Materials and Methods: Nine neonates with duct dependent but dual-source pulmonary blood flow (PBF) were included. Major stent-related complications, in-hospital course, stent patency up to 6 months, and unplanned re-interventions were studied, as well the percentage of stent material resorbed in patients in whom the stents were explanted at the surgery. Results: IBS Angel™ was successfully implanted in all nine patients (mean weight range 3.4 ± 0.4 kg). Six were pulmonary atresia with an intact ventricular septum and 1 critical pulmonary stenosis patients where PDA stenting was done together or after balloon dilation. The mean procedure and fluoroscopy times were 89 ± 39 min and 16.3 ± 6.9 min, respectively. There were no major complications such as stent thrombosis or embolization and there were no in-hospital deaths. Post procedure overshunting and prolonged ventilatory support was a prominent feature. The median ventilation days was 3 (1-11 days). One patient died after 1 month due to respiratory syncytial virus pneumonia at the referring hospital. At 6 months follow-up, four had patent stents and four had blocked or restrictive stent flow. One patient received re-stenting at 4 months for restrictive stent flow. In three patients where microcomputed tomography of explanted stent was available, resorption of iron was 15% at 6 months and >65% at 16 months. Conclusions: Ductal stenting with IBS Angel™ is feasible and safe in selected patients. Because of early luminal loss, its use may be recommended for lesions with dual-source PBF with noncomplex PDA morphology that requires a short duration of palliation.

7.
Cardiol Young ; 32(10): 1621-1627, 2022 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-35321770

RESUMO

BACKGROUND: Ceraflex septal occluder and the Figulla atrial septal defect occluder have the advantage of a pivoting mechanism and softer device architecture. This study sought to examine the safety and efficacy of these occluders compared to the Amplatzer septal occluder. METHODS: This was a retrospective study. Between January, 2013 and April, 2020, patients with at least 6 months of follow-up were included. Early and late-onset outcomes were examined. RESULTS: Four hundred seven patients (range: 0.17-70.72 years; 53.1% >18 years; male: 29.2%) underwent atrial septal defect occlusion using Amplatzer septal occluder (n = 313), Ceraflex septal occluder (n = 36) and FSO (n = 58). A longer procedure time was observed in the Amplatzer septal occluder group. Early-onset complication rates in Amplatzer septal occluder, Ceraflex septal occluder and Figulla atrial septal defect occluder were 3.83%, 5.56% and 0%. Ten (2.46%) patients developed delayed complications (2.56%, 0% and 1.72% in the Amplatzer septal occluder, Ceraflex septal occluder and Figulla atrial septal defect occluder groups). Device erosion rate was not different between groups. The occlusion rates were comparable among all the devices. CONCLUSION: There is no significant difference in safety and efficacies between the novel atrial septal defect occluding devices compared to Amplatzer septal occluder.


Assuntos
Comunicação Interatrial , Dispositivo para Oclusão Septal , Humanos , Masculino , Estudos Retrospectivos , Cateterismo Cardíaco/efeitos adversos , Resultado do Tratamento , Comunicação Interatrial/cirurgia
8.
Circ Cardiovasc Interv ; 14(12): e009750, 2021 12.
Artigo em Inglês | MEDLINE | ID: mdl-34903033

RESUMO

BACKGROUND: Coronary artery fistulas (CAFs) presenting in infancy are rare, and data regarding postclosure sequelae and follow-up are limited. METHODS: A retrospective review of all the neonates and infants (<1 year) was conducted from the CAF registry for CAF treatment. The CAF type (proximal or distal), size, treatment method, and follow-up angiography were reviewed to assess outcomes and coronary remodeling. RESULTS: Forty-eight patients were included from 20 centers. Of these, 30 were proximal and 18 had distal CAF; 39 were large, 7 medium, and 2 had small CAF. The median age and weight was 0.16 years (0.01-1) and 4.2 kg (1.7-10.6). Heart failure was noted in 28 of 48 (58%) patients. Transcatheter closure was performed in 24, surgical closure in 18, and 6 were observed medically. Procedural success was 92% and 94 % for transcatheter closure and surgical closure, respectively. Follow-up data were obtained in 34 of 48 (70%) at a median of 2.9 (0.1-18) years. Angiography to assess remodeling was available in 20 of 48 (41%). I. Optimal remodeling (n=10, 7 proximal and 3 distal CAF). II. Suboptimal remodeling (n=7) included (A) symptomatic coronary thrombosis (n=2, distal CAF), (B) asymptomatic coronary thrombosis (n=3, 1 proximal and 2 distal CAF), and (C) partial thrombosis with residual cul-de-sac (n=1, proximal CAF) and vessel irregularity with stenosis (n=1, distal CAF). Finally, (III) persistent coronary artery dilation (n=4). Antiplatelets and anticoagulation were used in 31 and 7 patients post-closure, respectively. Overall, 7 of 10 (70%) with proximal CAF had optimal remodeling, but 5 of 11 (45%) with distal CAF had suboptimal remodeling. Only 1 of 7 patients with suboptimal remodeling were on anticoagulation. CONCLUSIONS: Neonates/infants with hemodynamically significant CAF can be treated by transcatheter or surgical closure with excellent procedural success. Patients with distal CAF are at higher risk for suboptimal remodeling. Postclosure anticoagulation and follow-up coronary anatomic evaluation are warranted.


Assuntos
Anomalias dos Vasos Coronários , Fístula Vascular , Angiografia Coronária , Anomalias dos Vasos Coronários/diagnóstico por imagem , Anomalias dos Vasos Coronários/terapia , Seguimentos , Humanos , Lactente , Recém-Nascido , Sistema de Registros , Estudos Retrospectivos , Resultado do Tratamento
9.
Catheter Cardiovasc Interv ; 98(4): 738-742, 2021 10.
Artigo em Inglês | MEDLINE | ID: mdl-34143549

RESUMO

Ductal stenting in patients with duct-dependent pulmonary circulation has allowed growth of pulmonary arteries prior to definitive surgical procedures. Intraprocedural stent thrombosis (IPST) of the arterial duct is a life-threatening complication as it leads to total circulatory collapse. Previous reports have described use of tissue plasminogen activators in infants for less emergent settings. We report three infants with IPST and the use of tenecteplase to overcome this. Also discussed are the predisposing mechanisms in each scenario and a possibility of direct catheter-guided tenecteplase administration. Judicious use of tenecteplase can be life-saving and rapid access to this drug may obviate the need for emergency extracorporeal life support.


Assuntos
Circulação Pulmonar , Trombose , Humanos , Lactente , Artéria Pulmonar/diagnóstico por imagem , Stents , Tenecteplase , Trombose/diagnóstico por imagem , Trombose/etiologia , Resultado do Tratamento
10.
Sci Adv ; 7(23)2021 06.
Artigo em Inglês | MEDLINE | ID: mdl-34088662

RESUMO

Balancing the biodegradability and mechanical integrity of a bioresorbable scaffold (BRS) with time after implantation to match the remodeling of the scaffolded blood vessel is important, but a key challenge in doing so remains. This study presents a novel intercalated structure of a metallic BRS by introducing a nanoscale Zn sacrificial layer between the nitrided Fe platform and the sirolimus-carrying poly(d,l-lactide) drug coating. The PDLLA-Zn-FeN BRS shows a multistage biodegradation behavior, maintaining mechanical integrity at the initial stage and exhibiting accelerated biodegradation at the subsequent stage in both rabbit abdominal aortas and human coronary arteries, where complete biodegradation was observed about 2 years after implantation. The presence of the nanoscale Zn sacrificial layer with an adjustable thickness also contributes to the tunable biodegradation of BRS and allows the reduction of the metallic strut thickness to 53 µm, with radial strength as strong as that of the current permanent drug-eluting stents.

11.
Cardiol Young ; 31(12): 2031-2034, 2021 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-34053471

RESUMO

Device occlusion of perimembranous ventricular septal defect is gaining popularity with the emergence of newer, softer occluders and improved technical know-how. We report a 26-year-old lady with a moderate size perimembranous ventricular septal defect who had a new onset of bundle branch block shortly after device closure. The patient subsequently developed a complete atrio-ventricular heart block.


Assuntos
Bloqueio Atrioventricular , Comunicação Interventricular , Dispositivo para Oclusão Septal , Adulto , Bloqueio Atrioventricular/diagnóstico , Bloqueio Atrioventricular/etiologia , Bloqueio de Ramo/diagnóstico , Bloqueio de Ramo/etiologia , Cateterismo Cardíaco/efeitos adversos , Feminino , Comunicação Interventricular/cirurgia , Humanos , Dispositivo para Oclusão Septal/efeitos adversos , Resultado do Tratamento
14.
Interact Cardiovasc Thorac Surg ; 31(2): 221-227, 2020 08 01.
Artigo em Inglês | MEDLINE | ID: mdl-32437520

RESUMO

OBJECTIVES: This study aims to review our institutional experience of ductal stenting (DS) on the growth of pulmonary arteries (PAs) and surgical outcomes of PA reconstruction in this subset of patients. METHODS: This is a retrospective study done in neonates and infants up to 3 months of age with duct-dependent pulmonary circulation who underwent DS from January 2014 to December 2015. Post-stenting PA growth, surgical outcomes of PA reconstruction, post-surgical re-interventions, morbidity and mortality were analysed. RESULTS: During the study period, 46 patients underwent successful DS, of whom 38 underwent presurgery catheterization and definite surgery. There was significant growth of PAs in these patients. Biventricular repair was done in 31 patients while 7 had univentricular palliation. Left PA augmentation was required in 13 patients, and 10 required central PA augmentation during surgery. The mean follow-up period post-surgery was 4.5 ± 1.5 years. No significant postoperative complications were seen. No early or follow-up post-surgery mortality was seen. Four patients required re-interventions in the form of left PA stenting based on the echocardiography or computed tomography evidence of significant stenosis. CONCLUSIONS: DS provides good short-term palliation and the growth of PAs. However, a significant number of stented patients require reparative procedure on PAs at the time of surgical intervention. Acquired changes in the PAs following DS may be the reason for reintervention following PA reconstruction.


Assuntos
Cateterismo Cardíaco/métodos , Cardiopatias Congênitas/cirurgia , Cuidados Paliativos/métodos , Artéria Pulmonar/cirurgia , Circulação Pulmonar/fisiologia , Stents , Procedimentos Cirúrgicos Vasculares/métodos , Feminino , Cardiopatias Congênitas/mortalidade , Cardiopatias Congênitas/fisiopatologia , Mortalidade Hospitalar/tendências , Humanos , Lactente , Recém-Nascido , Malásia/epidemiologia , Masculino , Procedimentos de Cirurgia Plástica/métodos , Estudos Retrospectivos , Taxa de Sobrevida/tendências , Fatores de Tempo , Resultado do Tratamento
15.
Ann Thorac Surg ; 108(3): 813-819, 2019 09.
Artigo em Inglês | MEDLINE | ID: mdl-30998905

RESUMO

BACKGROUND: Ductal stenting is performed to retrain involuted left ventricles (LVs) in patients with d-transposition of the great arteries and intact ventricular septum (TGA-IVS). However, its efficacy is largely unknown. This study aimed to determine the safety and efficacy of ductal stenting in retraining of the involuted LV in patients with TGA-IVS. METHODS: This was a single-center, retrospective study. Echocardiographic assessment of the LV geometry, mass, and free wall thickness was performed before stenting and before the arterial switch operation. Patients then underwent the arterial switch operation, and the postoperative outcomes were reviewed. RESULTS: There were 11 consecutive patients (male, 81.8%; mean age at stenting, 43.11 ± 18.19 days) with TGA-IVS with involuted LV who underwent LV retraining by ductal stenting from July 2013 to December 2017. Retraining by ductus stenting failed in 4 patients (36.3%). Two patients required pulmonary artery banding, and another 2 had an LV mass index of less than 35 g/m2. Patients in the successful group had improved LV mass index from 45.14 ± 17.91 to 81.86 ± 33.11g/m2 (p = 0.023) compared with 34.50 ± 10.47 to 20.50 ± 9.88 g/m2 (p = 0.169) and improved LV geometry after ductal stenting. The failed group was associated with an increased need for extracorporeal support (14.5% vs 50%, p = 0.012). An atrial septal defect-to-interatrial septum length ratio of more than 0.38 was associated with failed LV retraining. CONCLUSIONS: Ductal stenting is an effective method to retrain the involuted LV in TGA-IVS. A large atrial septal defect (atrial septal defect-to-interatrial septum length ratio >0.38) was associated with poor response to LV retraining.


Assuntos
Transposição das Grandes Artérias/métodos , Comunicação Interatrial/cirurgia , Stents , Transposição dos Grandes Vasos/diagnóstico por imagem , Transposição dos Grandes Vasos/cirurgia , Função Ventricular Esquerda/fisiologia , Centros Médicos Acadêmicos , Estudos de Coortes , Canal Arterial/diagnóstico por imagem , Canal Arterial/cirurgia , Ecocardiografia/métodos , Feminino , Seguimentos , Comunicação Interatrial/diagnóstico por imagem , Ventrículos do Coração/cirurgia , Humanos , Recém-Nascido , Malásia , Masculino , Segurança do Paciente , Estudos Retrospectivos , Medição de Risco , Análise de Sobrevida , Transposição dos Grandes Vasos/mortalidade
16.
Future Cardiol ; 14(1): 55-73, 2018 01.
Artigo em Inglês | MEDLINE | ID: mdl-29199861

RESUMO

Patent ductus arteriosus (PDA) stenting has gained acceptance for palliation in cyanotic congenital heart disease. The PDA in tetralogy of Fallot with pulmonary atresia (ToF-PA) arises, in the left aortic arch, from underneath the arch and connects to the proximal left pulmonary artery, often resulting in stenosis. The PDA is usually elongated and tortuous, making stent implantation challenging. Shorter duration of palliation, aggravation of branch pulmonary artery stenosis resulting in poor growth and difficulty at surgery makes ductal stenting controversial. Access via the carotid and axillary artery reduces complexity of the procedure and improves success, with recent data demonstrating good pulmonary artery growth. Advances in bioresorbable stents offer future promise and will likely resolve some controversies surrounding PDA stenting in ToF-PA.


Assuntos
Procedimentos Cirúrgicos Cardíacos/métodos , Permeabilidade do Canal Arterial/cirurgia , Defeitos dos Septos Cardíacos/cirurgia , Cuidados Paliativos/métodos , Atresia Pulmonar/cirurgia , Stents , Tetralogia de Fallot/cirurgia , Cateterismo Cardíaco , Humanos
18.
Ann Pediatr Cardiol ; 10(3): 281-283, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-28928615

RESUMO

We report a case of Tetralogy of Fallot with severe cyanosis who underwent a successful right ventricular outflow tract stenting. Follow-up echocardiography revealed moderate aortic regurgitation due to the impingement of the stent on the aortic valve. The patient underwent successful surgical correction at which time the stent was removed completely with a resolution of the aortic regurgitation.

19.
Ann Pediatr Cardiol ; 10(2): 203-205, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-28566832

RESUMO

We report an 8-year-old male child with tetralogy of Fallot (TOF), who developed left pulmonary artery (LPA) atresia, following surgical repair of TOF and left pulmonary arterioplasty at the age of 6 years. He underwent successful radiofrequency recanalization and stenting of the LPA. The LPA exhibited satisfactory growth for 3 months, following recanalization and stenting.

20.
Ann Pediatr Cardiol ; 10(2): 206-208, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-28566833

RESUMO

We report our experience with a stent migration after right ventricle outflow tract stenting and converted to patent ductus arteriosus stenting in Tetralogy of Fallot (TOF) with severe infundibular stenosis. Finally, the patient achieved to TOF repair, and the migrated stent was removed without any complication.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA