Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 290
Filtrar
1.
Artigo em Inglês | MEDLINE | ID: mdl-38829174

RESUMO

BACKGROUND: Vasopressor test (VPT) might be useful in patients with functional mitral regurgitation (MR) and left ventricular dysfunction (MITRA-FR-like patients) during transcatheter edge-to-edge repair (TEER). AIMS: We aimed to evaluate the prognostic impact of VPT. METHODS: MR treated with TEER were included in a multicenter prospective registry. VPT was used intraprocedurally in patients with left ventricular dysfunction and/or hypotension. The 1-year echocardiographic and clinical outcomes were compared according to the use of VPT. The primary endpoint was a combination of mortality + heart failure (HF) readmission at 1-year. RESULTS: A total of 1115 patients were included, mean age was 72.8 ± 10.5 years and 30.4% were women. VPT was performed in 128 subjects (11.5%), more often in critically ill patients with biventricular dysfunction. Postprocedurally the VPT group had greater rate of MR ≥ 2+ (46.9% vs. 31.7%, p = 0.003) despite greater number of devices (≥2 clips, 52% vs. 40.6 p = 0.008) and device repositioning or new clip in 12.5%. At 1-year, the primary endpoint occurred more often in the VPT group (27.3% vs. 16.9%, p = 0.002) as well as all-cause mortality (21.9% vs. 8.1%, p ≤ 0.001) but no differences existed in HF readmission rate (14.8% vs. 13.2%, p = 0.610), cardiovascular mortality (4.4% vs. 3.9%, p = 0.713) or residual MR ≥ 2+ (51.1% vs 51.7%, p = 0.371). CONCLUSIONS: Dynamic evaluation of MR during TEER procedure through VPT was performed in patients with worse baseline risk who also presented higher all-cause mortality at 1-year follow-up. However, 1-year residual MR, cardiovascular mortality and HF readmission rate remained comparable suggesting that VPT might help in the management of MITRA-FR-like patients.

2.
Int J Cardiol ; : 132179, 2024 May 16.
Artigo em Inglês | MEDLINE | ID: mdl-38761972

RESUMO

BACKGROUND: Optimal strategies to manage embolization of transcatheter aortic valve implantation (TAVI) devices are unclear; valve-in-valve (ViV) is often used. We aimed to describe through one-single center experience its rate, causes, consequences, and management as well as the rate and relevance of commissural alignment (CA) in this context. METHODS: We identified across 1038 TAVI cases, those cases requiring ViV for the management of first device embolization. CA (absence or mild misalignment) after first and second device was assessed by CT or fluoroscopy. RESULTS: A total of 23 cases (2.2%) were identified, 52.3% embolized towards the aorta and 47.7% towards the ventricle. Suboptimal implant height (38%) and embolization at the time of post-dilation (23%) were the most frequent mechanisms together with greater rate of bicuspid valve (p < 0.001) and a trend to greater annular eccentricity. Procedural and 1-year death occurred in 13% and 34%, respectively (vs. 1.1% and 7.8% in the global cohort, p < 0.001). CA was present in 76.9% of the prostheses initially implanted but was only spontaneously achieved in 30.8% of the second ViV device. Adequate CA of both prostheses was identified in only two cases (8.7%). There were no cases of coronary obstruction. CONCLUSIONS: TAVI device embolization mechanisms can often be predicted and prevented. Mortality following bail-out ViV is higher than in regular TAVI procedures but 2/3 of these patients survived beyond 1-year follow-up. In them, valve degeneration or coronary re-access might be particularly challenging since CA was rarely achieved with both devices suggesting that greater efforts should be made in this regard.

3.
Lancet ; 2024 May 22.
Artigo em Inglês | MEDLINE | ID: mdl-38795719

RESUMO

BACKGROUND: Transcatheter aortic valve implantation is an established, guideline-endorsed treatment for severe aortic stenosis. Precise sizing of the balloon-expandable Myval transcatheter heart valve (THV) series with the aortic annulus is facilitated by increasing its diameter in 1·5 mm increments, compared with the usual 3 mm increments in valve size. The LANDMARK trial aimed to show non-inferiority of the Myval THV series compared with the contemporary THVs Sapien Series (Edwards Lifesciences, Irvine, CA, USA) or Evolut Series (Medtronic, Minneapolis, MN, USA). METHODS: In this prospective, multinational, randomised, open-label, non-inferiority trial across 31 hospitals in 16 countries (Germany, France, Sweden, the Netherlands, Italy, Spain, New Zealand, Portugal, Greece, Hungary, Poland, Slovakia, Slovenia, Croatia, Estonia, and Brazil), 768 participants with severe symptomatic native aortic stenosis were randomly assigned (1:1) to the Myval THV or a contemporary THV. Eligibility was primarily decided by the heart team in accordance with 2021 European Society of Cardiology guidelines. As per the criteria of the third Valve Academic Research Consortium, the primary endpoint at 30 days was a composite of all-cause mortality, all stroke, bleeding (types 3 and 4), acute kidney injury (stages 2-4), major vascular complications, moderate or severe prosthetic valve regurgitation, and conduction system disturbances resulting in a permanent pacemaker implantation. Non-inferiority of the study device was tested in the intention-to-treat population using a non-inferiority margin of 10·44% and assuming an event rate of 26·10%. This trial is registered with ClinicalTrials.gov, NCT04275726, and EudraCT, 2020-000137-40, and is closed to new participants. FINDINGS: Between Jan 6, 2021, and Dec 5, 2023, 768 participants with severe symptomatic native aortic stenosis were randomly assigned, 384 to the Myval THV and 384 to a contemporary THV. 369 (48%) participants had their sex recorded as female, and 399 (52%) as male. The mean age of participants was 80·0 years (SD 5·7) for those treated with the Myval THV and 80·4 years (5·4) for those treated with a contemporary THV. Median Society of Thoracic Surgeons scores were the same in both groups (Myval 2·6% [IQR 1·7-4·0] vs contemporary 2·6% [1·7-4·0]). The primary endpoint showed non-inferiority of the Myval (25%) compared with contemporary THV (27%), with a risk difference of -2·3% (one-sided upper 95% CI 3·8, pnon-inferiority<0·0001). No significant difference was seen in individual components of the primary composite endpoint. INTERPRETATION: In individuals with severe symptomatic native aortic stenosis, the Myval THV met its primary endpoint at 30 days. FUNDING: Meril Life Sciences.

4.
EuroIntervention ; 20(10): e656-e668, 2024 May 20.
Artigo em Inglês | MEDLINE | ID: mdl-38776142

RESUMO

BACKGROUND: Coronary calcification negatively impacts optimal stenting. Intravascular lithotripsy (IVL) is a new calcium modification technique. AIMS: We aimed to assess the impact of different calcium morphologies on IVL efficacy. METHODS: This was a prospective, multicentre study (13 tertiary referral centres). Optical coherence tomography (OCT) was performed before and after IVL, and after stenting. OCT-defined calcium morphologies were concentric (mean calcium arc >180°) and eccentric (mean calcium arc ≤180°). The primary outcomes were angiographic success (residual stenosis <20%) and the presence of fracture by OCT in concentric versus eccentric lesions. RESULTS: Ninety patients were included with a total of 95 lesions: 47 concentric and 48 eccentric. The median number of pulses was 60 (p=1.00). Following IVL, the presence of fracture was not statistically different between groups (79.0% vs 66.0% for concentric vs eccentric; p=0.165). The number of fractures/lesion (4.2±4.4 vs 2.3±2.8; p=0.018) and ≥3 fractures/lesion (57.1% vs 34.0%; p=0.029) were more common in concentric lesions. Angiographic success was numerically but not statistically higher in the concentric group (87.0% vs 76.6%; p=0.196). By OCT, no differences were noted in final minimum lumen area (5.9±2.2 mm2 vs 6.2±2.1 mm2; p=0.570), minimum stent area (5.9±2.2 mm² vs 6.25±2.4 mm2; p=0.483), minimum stent expansion (80.9±16.7% vs 78.2±19.8%), or stent expansion at the maximum calcium site (100.6±24.2% vs 95.8±27.3%) (p>0.05 for all comparisons of concentric vs eccentric, respectively). Calcified nodules were found in 29.5% of lesions; these were predominantly non-eruptive (57%). At the nodule site, dissection was more common than fracture with stent expansion of 103.6±27.2%. CONCLUSIONS: In this prospective, multicentre study, the effectiveness of IVL followed by stenting was not significantly affected by coronary calcium morphology.


Assuntos
Angiografia Coronária , Doença da Artéria Coronariana , Litotripsia , Tomografia de Coerência Óptica , Calcificação Vascular , Humanos , Litotripsia/métodos , Masculino , Feminino , Pessoa de Meia-Idade , Idoso , Estudos Prospectivos , Calcificação Vascular/diagnóstico por imagem , Calcificação Vascular/terapia , Resultado do Tratamento , Doença da Artéria Coronariana/terapia , Doença da Artéria Coronariana/diagnóstico por imagem , Stents , Intervenção Coronária Percutânea/métodos , Vasos Coronários/diagnóstico por imagem , Vasos Coronários/patologia , Cálcio
5.
Artigo em Inglês | MEDLINE | ID: mdl-38752972

RESUMO

BACKGROUND: The role of quantitative flow ratio (QFR) in the treatment of nonculprit vessels of patients with myocardial infarction (MI) is a topic of ongoing discussion. OBJECTIVES: This study aimed to investigate the predictive capability of QFR for adverse events and its noninferiority compared to wire-based functional assessment in nonculprit vessels of MI patients. METHODS: The FIRE (Functional Assessment in Elderly MI Patients With Multivessel Disease) trial randomized 1,445 older MI patients to culprit-only (n = 725) or physiology-guided complete revascularization (n = 720). In the culprit-only arm, angiographic projections of nonculprit vessels were prospectively collected, centrally reviewed for QFR computation, and associated with endpoints. In the complete revascularization arm, endpoints were compared between nonculprit vessels investigated with QFR or wire-based functional assessment. The primary endpoint was the vessel-oriented composite endpoint (VOCE) at 1 year. RESULTS: QFR was measured on 903 nonculprit vessels from 685 patients in the culprit-only arm. Overall, 366 (40.5%) nonculprit vessels showed a QFR value ≤0.80, with a significantly higher incidence of VOCEs (22.1% vs 7.1%; P < 0.001). QFR ≤0.80 emerged as an independent predictor of VOCEs (HR: 2.79; 95% CI: 1.64-4.75). In the complete arm, QFR was used in 320 (35.2%) nonculprit vessels to guide revascularization. When compared with propensity-matched nonculprit vessels in which treatment was guided by wire-based functional assessment, no significant difference was observed (HR: 0.57; 95% CI: 0.28-1.15) in VOCEs. CONCLUSIONS: This prespecified subanalysis of the FIRE trial provides evidence supporting the safety and efficacy of QFR-guided interventions for the treatment of nonculprit vessels in MI patients. (Functional Assessment in Elderly MI Patients With Multivessel Disease [FIRE]; NCT03772743).

6.
Artigo em Inglês | MEDLINE | ID: mdl-38753292

RESUMO

A data-driven reduced order model (ROM) based on a proper orthogonal decomposition-radial basis function (POD-RBF) approach is adopted in this paper for the analysis of blood flow dynamics in a patient-specific case of atrial fibrillation (AF). The full order model (FOM) is represented by incompressible Navier-Stokes equations, discretized with a finite volume (FV) approach. Both the Newtonian and the Casson's constitutive laws are employed. The aim is to build a computational tool able to efficiently and accurately reconstruct the patterns of relevant hemodynamics indices related to the stasis of the blood in a physical parametrization framework including the cardiac output in the Newtonian case and also the plasma viscosity and the hematocrit in the non-Newtonian one. Many FOM-ROM comparisons are shown to analyze the performance of our approach as regards errors and computational speed-up.

7.
Lancet ; maio.2024.
Artigo em Inglês | CONASS, Sec. Est. Saúde SP, SESSP-IDPCPROD, Sec. Est. Saúde SP | ID: biblio-1555077

RESUMO

BACKGROUND Transcatheter aortic valve implantation is an established, guideline-endorsed treatment for severe aortic stenosis. Precise sizing of the balloon-expandable Myval transcatheter heart valve (THV) series with the aortic annulus is facilitated by increasing its diameter in 1•5 mm increments, compared with the usual 3 mm increments in valve size. The LANDMARK trial aimed to show non-inferiority of the Myval THV series compared with the contemporary THVs Sapien Series (Edwards Lifesciences, Irvine, CA, USA) or Evolut Series (Medtronic, Minneapolis, MN, USA). METHODS In this prospective, multinational, randomised, open-label, non-inferiority trial across 31 hospitals in 16 countries (Germany, France, Sweden, the Netherlands, Italy, Spain, New Zealand, Portugal, Greece, Hungary, Poland, Slovakia, Slovenia, Croatia, Estonia, and Brazil), 768 participants with severe symptomatic native aortic stenosis were randomly assigned (1:1) to the Myval THV or a contemporary THV. Eligibility was primarily decided by the heart team in accordance with 2021 European Society of Cardiology guidelines. As per the criteria of the third Valve Academic Research Consortium, the primary endpoint at 30 days was a composite of all-cause mortality, all stroke, bleeding (types 3 and 4), acute kidney injury (stages 2­4), major vascular complications, moderate or severe prosthetic valve regurgitation, and conduction system disturbances resulting in a permanent pacemaker implantation. Non-inferiority of the study device was tested in the intention-to-treat population using a non-inferiority margin of 10•44% and assuming an event rate of 26•10%. This trial is registered with ClinicalTrials.gov, NCT04275726, and EudraCT, 2020-000137-40, and is closed to new participants. FINDINGS Between Jan 6, 2021, and Dec 5, 2023, 768 participants with severe symptomatic native aortic stenosis were randomly assigned, 384 to the Myval THV and 384 to a contemporary THV. 369 (48%) participants had their sex recorded as female, and 399 (52%) as male. The mean age of participants was 80•0 years (SD 5•7) for those treated with the Myval THV and 80•4 years (5•4) for those treated with a contemporary THV. Median Society of Thoracic Surgeons scores were the same in both groups (Myval 2•6% [IQR 1•7­4•0] vs contemporary 2•6% [1•7­4•0]). The primary endpoint showed non-inferiority of the Myval (25%) compared with contemporary THV (27%), with a risk difference of ­2•3% (one-sided upper 95% CI 3•8, pnon-inferiority<0•0001). No significant difference was seen in individual components of the primary composite endpoint. INTERPRETATION In individuals with severe symptomatic native aortic stenosis, the Myval THV met its primary endpoint at 30 days.

8.
EuroIntervention ; 20(8): e487-e495, 2024 Apr 15.
Artigo em Inglês | MEDLINE | ID: mdl-38629416

RESUMO

BACKGROUND: Data on the likelihood of left ventricle (LV) recovery in patients with severe LV dysfunction and severe aortic stenosis undergoing transcatheter aortic valve implantation (TAVI) and its prognostic value are limited. AIMS: We aimed to assess the likelihood of LV recovery following TAVI, examine its association with midterm mortality, and identify independent predictors of LV function. METHODS: In our multicentre registry of 17 TAVI centres in Western Europe and Israel, patients were stratified by baseline LV function (ejection fraction [EF] >/≤30%) and LV response: no LV recovery, LV recovery (EF increase ≥10%), and LV normalisation (EF ≥50% post-TAVI). RESULTS: Our analysis included 10,872 patients; baseline EF was ≤30% in 914 (8.4%) patients and >30% in 9,958 (91.6%) patients. The LV recovered in 544 (59.5%) patients, including 244 (26.7%) patients whose LV function normalised completely (EF >50%). Three-year mortality for patients without severe LV dysfunction at baseline was 29.4%. Compared to this, no LV recovery was associated with a significant increase in mortality (adjusted hazard ratio 1.32; p<0.001). Patients with similar LV function post-TAVI had similar rates of 3-year mortality, regardless of their baseline LV function. Three variables were associated with a higher likelihood of LV recovery following TAVI: no previous myocardial infarction (MI), estimated glomerular filtration rate >60 mL/min, and mean aortic valve gradient (mAVG) (expressed either as a continuous variable or as a binary variable using the standard low-flow, low-gradient aortic stenosis [AS] definition). CONCLUSIONS: LV recovery following TAVI and the extent of this recovery are major determinants of midterm mortality in patients with severe AS and severe LV dysfunction undergoing TAVI. Patients with no previous MI and those with an mAVG >40 mmHg show the best results following TAVI, which are at least equivalent to those for patients without severe LV dysfunction. (ClinicalTrials.gov: NCT04031274).


Assuntos
Estenose da Valva Aórtica , Substituição da Valva Aórtica Transcateter , Disfunção Ventricular Esquerda , Humanos , Valva Aórtica/cirurgia , Ventrículos do Coração , Volume Sistólico , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento , Função Ventricular Esquerda , Estudos Multicêntricos como Assunto , Estudos Clínicos como Assunto
10.
EuroIntervention ; 20(8): e479-e486, 2024 Apr 15.
Artigo em Inglês | MEDLINE | ID: mdl-38629415

RESUMO

BACKGROUND: In patients presenting with acute coronary syndrome (ACS), the number of diseased vessels may affect the efficacy of a complete revascularisation strategy. AIMS: The authors sought to evaluate the safety and efficacy of immediate complete revascularisation (ICR) and staged complete revascularisation (SCR) in patients presenting with ACS stratified by the number of diseased vessels. METHODS: In this prespecified analysis of the BIOVASC trial, ICR was compared with SCR in patients with two-vessel disease (2VD) or three-vessel disease (3VD). The primary endpoint was a composite of all-cause mortality, myocardial infarction (MI), any unplanned ischaemia-driven revascularisation or cerebrovascular events at 1 year after the index procedure. Comparisons were performed using Cox regression. RESULTS: A total of 1,525 patients were enrolled in the BIOVASC trial, of whom 1,177 presented with 2VD and 265 with 3VD. In the 2VD group, 613 patients were assigned to ICR and 564 to SCR. In the 3VD group, 117 patients were assigned to ICR and 148 to SCR. ICR and SCR led to similar results in both the 2VD (hazard ratio [HR] 0.76, 95% confidence interval [CI]: 0.50-1.13; p=0.18) and 3VD groups (HR 0.79, 95% CI: 0.39-1.59; p=0.51) (pinteraction=0.91) in terms of the primary endpoint. ICR was associated with a lower rate of MI in patients with 3VD (HR 0.21, 95% CI: 0.046-0.93; p=0.04) (pinteraction=0.30). CONCLUSIONS: ICR might be an option in patients presenting with extensive 3VD and might be associated with a lower rate of myocardial infarction compared with SCR.


Assuntos
Síndrome Coronariana Aguda , Doença da Artéria Coronariana , Infarto do Miocárdio , Intervenção Coronária Percutânea , Humanos , Síndrome Coronariana Aguda/cirurgia , Resultado do Tratamento , Ponte de Artéria Coronária/métodos , Procedimentos Cirúrgicos Vasculares , Intervenção Coronária Percutânea/métodos , Doença da Artéria Coronariana/cirurgia
11.
Glob Heart ; 19(1): 38, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38681970

RESUMO

Background: Opium consumption has been an overlooked health issue in the Iranian population, and the prognostic role of opium consumption in patients undergoing coronary revascularization is unknown. Hypothesis: We aimed to assess the association between opium consumption and long-term cardiovascular outcomes after percutaneous coronary intervention (PCI). Methods: We screened 2203 consecutive patients who underwent elective PCI between April 2009 and April 2010 at Tehran Heart Center. Exclusion criteria were unsuccessful PCI, non-elective PCI, and missing opium use data. Opium consumption was defined as self-reported ever use of any traditional opium substances. Outcomes of interest were all-cause mortality and a composite of major adverse cardiac and cerebrovascular events (MACCE). The association between opium use and study outcomes was evaluated using the inverse probability of treatment weighting (IPTW) method. Cumulative hazard curves were demonstrated to further assess the association visually. Furthermore, the effect of opium consumption on individual components of MACCE was evaluated in a competing risk setting. Results: A total of 2025 elective PCI patients were included (age: 58.7 ± 10.67, 29.1% women), among whom 297 (14.6%) patients were opium users. After a median follow-up of 10.7 years, opium consumption was associated with a higher risk of all-cause mortality (IPTW-hazard ratio [HR] = 1.705, 95% CI: 1.125-2.585; P = 0.012) and MACCE (IPTW-HR = 1.578, 95% CI: 1.156-2.153; P = 0.004). The assessment of MACCE components suggested a non-significant borderline trend for higher non-fatal myocardial infarction (IPTW-sub-distribution HR [SHR] = 1.731, 95% CI: 0.928-3.231; P = 0.084) and mortality (IPTW-SHR = 1.441, 95% CI: 0.884-2.351; P = 0.143) among opium users. Conclusions: Opium consumption is associated with a more than 50% increase in long-term risk of mortality and MACCE in patients undergoing PCI. These findings accentuate the importance of preventive strategies to quit opium addiction in this population.


Assuntos
Ópio , Intervenção Coronária Percutânea , Humanos , Masculino , Feminino , Pessoa de Meia-Idade , Irã (Geográfico)/epidemiologia , Seguimentos , Fatores de Tempo , Dependência de Ópio/epidemiologia , Fatores de Risco , Doença da Artéria Coronariana/epidemiologia , Idoso , Estudos Retrospectivos , Taxa de Sobrevida/tendências
12.
Cardiovasc Revasc Med ; 64: 7-14, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38448258

RESUMO

BACKGROUND: Left atrial appendage (LAA) occluder embolization is an infrequent but serious complication. OBJECTIVES: We aim to describe timing, management and clinical outcomes of device embolization in a multi-center registry. METHODS: Patient characteristics, imaging findings and procedure and follow-up data were collected retrospectively. Device embolizations were categorized according to 1) timing 2) management and 3) clinical outcomes. RESULTS: Sixty-seven centers contributed data. Device embolization occurred in 108 patients. In 70.4 % of cases, it happened within the first 24 h of the procedure. The device was purposefully left in the LA and the aorta in two (1.9 %) patients, an initial percutaneous retrieval was attempted in 81 (75.0 %) and surgery without prior percutaneous retrieval attempt was performed in 23 (21.3 %) patients. Two patients died before a retrieval attempt could be made. In 28/81 (34.6 %) patients with an initial percutaneous retrieval attempt a second, additional attempt was performed, which was associated with a high mortality (death in patients with one attempt: 2.9 % vs. second attempt: 21.4 %, p < 0.001). The primary outcome (bailout surgery, cardiogenic shock, stroke, TIA, and/or death) occurred in 47 (43.5 %) patients. Other major complications related to device embolization occurred in 21 (19.4 %) patients. CONCLUSIONS: The majority of device embolizations after LAA closure occurs early. A percutaneous approach is often the preferred method for a first rescue attempt. Major adverse event rates, including death, are high particularly if the first retrieval attempt was unsuccessful. CONDENSED ABSTRACT: This dedicated multicenter registry examined timing, management, and clinical outcome of device embolization. Early embolization (70.4 %) was most frequent. As a first rescue attempt, percutaneous retrieval was preferred in 75.0 %, followed by surgical removal (21.3 %). In patients with a second retrieval attempt a higher mortality (death first attempt: 2.9 % vs. death second attempt: 24.1 %, p < 0.001) was observed. Mortality (10.2 %) and the major complication rate after device embolization were high.


Assuntos
Apêndice Atrial , Fibrilação Atrial , Cateterismo Cardíaco , Remoção de Dispositivo , Sistema de Registros , Humanos , Masculino , Apêndice Atrial/diagnóstico por imagem , Apêndice Atrial/fisiopatologia , Feminino , Idoso , Estudos Retrospectivos , Resultado do Tratamento , Fatores de Tempo , Idoso de 80 Anos ou mais , Fatores de Risco , Cateterismo Cardíaco/efeitos adversos , Cateterismo Cardíaco/instrumentação , Cateterismo Cardíaco/mortalidade , Fibrilação Atrial/terapia , Fibrilação Atrial/mortalidade , Remoção de Dispositivo/efeitos adversos , Embolia/etiologia , Embolia/mortalidade , Pessoa de Meia-Idade , Dispositivo para Oclusão Septal , Oclusão do Apêndice Atrial Esquerdo
14.
J Am Heart Assoc ; 13(7): e032955, 2024 Apr 02.
Artigo em Inglês | MEDLINE | ID: mdl-38533944

RESUMO

BACKGROUND: Dialysis is a rare but serious complication after transcatheter aortic valve replacement. We analyzed the large multicenter TRITAVI (transfusion requirements in transcatheter aortic valve implantation) registry in order to develop and validate a clinical score assessing this risk. METHODS AND RESULTS: A total of 10 071 consecutive patients were enrolled in 19 European centers. Patients were randomly assigned (2:1) to a derivation and validation cohort. Two scores were developed, 1 including only preprocedural variables (TRITAVIpre) and 1 also including procedural variables (TRITAVIpost). In the 6714 patients of the derivation cohort (age 82±6 years, 48% men), preprocedural factors independently associated with dialysis and included in the TRITAVIpre score were male sex, diabetes, prior coronary artery bypass graft, anemia, nonfemoral access, and creatinine clearance <30 mL/min per m2. Additional independent predictors among procedural features were volume of contrast, need for transfusion, and major vascular complications. Both scores showed a good discrimination power for identifying risk for dialysis with C-statistic 0.78 for TRITAVIpre and C-statistic 0.88 for TRITAVIpost score. Need for dialysis increased from the lowest to the highest of 3 risk score groups (from 0.3% to 3.9% for TRITAVIpre score and from 0.1% to 6.2% for TRITAVIpost score). Analysis of the 3357 patients of the validation cohort (age 82±7 years, 48% men) confirmed the good discrimination power of both scores (C-statistic 0.80 for TRITAVIpre and 0.81 for TRITAVIpost score). Need for dialysis was associated with a significant increase in 1-year mortality (from 6.9% to 54.4%; P=0.0001). CONCLUSIONS: A simple preprocedural clinical score can help predict the risk of dialysis after transcatheter aortic valve replacement.


Assuntos
Estenose da Valva Aórtica , Diabetes Mellitus , Substituição da Valva Aórtica Transcateter , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/cirurgia , Sistema de Registros , Diálise Renal , Fatores de Risco , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento , Estudos Multicêntricos como Assunto
15.
Mayo Clin Proc ; 99(3): 400-410, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38432746

RESUMO

OBJECTIVE: To describe the evolution of symptoms in patients with symptomatic severe aortic stenosis (sSAS) undergoing valve replacement, the predictors of the persistence of these symptoms, and their prognostic significance. The evolution of symptoms after intervention in sSAS and their association with outcome are unknown. PATIENTS AND METHODS: Data from patients with sSAS who underwent intervention were collected. All-cause mortality and cardiovascular mortality were considered events. The evolution of symptoms and their association with events were studied. RESULTS: In this study, 451 consecutive patients with sSAS and no other valvular or coronary disease who were alive 30 days after intervention were included. Before valve replacement, 133 of the 451 patients (29.5%) had congestive heart failure requiring hospitalization. Of the remaining 318 patients, 287 (90.2%) had dyspnea on effort, 129 (40.6%) had angina, and 59 had syncope (18.6%). Symptoms disappeared after intervention in 192 of the 451 patients (42.6%) and remained in 259 (57.4%): 193 dyspnea, 9 angina, 17 syncope, and 60 admission for heart failure. Syncope on effort persisted in 4 of 33 patients (12.1%) and at rest in 11 of 20 (55.0%; P<.001). Age, body mass index, previous admission for heart failure, and chronic obstructive pulmonary disease were independently related to persistence of symptoms. Over a median follow-up of 56 months in our cohort of 451 patients, 129 deaths were registered (28.6%), 40 of which were cardiovascular (8.9%). Age, chronic obstructive pulmonary disease, chronic kidney disease, atrial fibrillation, heart failure, and persistence of symptoms were independently associated with all-cause mortality. CONCLUSION: Symptoms attributed to SAS remain after intervention in a high proportion of patients, particularly dyspnea on effort and syncope at rest. The persistence of symptoms after intervention identifies patients with poor outcome.


Assuntos
Estenose da Valva Aórtica , Insuficiência Cardíaca , Doença Pulmonar Obstrutiva Crônica , Humanos , Prognóstico , Síncope , Constrição Patológica , Dispneia/etiologia , Doença Pulmonar Obstrutiva Crônica/complicações , Medidas de Resultados Relatados pelo Paciente , Estenose da Valva Aórtica/complicações , Estenose da Valva Aórtica/cirurgia
16.
Am Heart J ; 270: 86-94, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38309610

RESUMO

BACKGROUND: Patients with severe aortic stenosis (AS) frequently present with concomitant obstructive coronary artery disease (CAD). In those, current guidelines recommend combined coronary artery bypass grafting (CABG) and surgical aortic valve replacement (SAVR) as the preferred treatment option, although this surgical approach is associated with a high rate of clinical events. Combined transcatheter aortic valve implantation (TAVI) and percutaneous coronary intervention (PCI) with or without FFR have evolved as a valid alternative for cardiac surgery in patients with AS and multivessel or advanced CAD. To date, no dedicated trial has prospectively evaluated the outcomes of a percutaneous versus surgical treatment for patients with both severe AS and CAD. AIMS: To investigate whether fractional-flow reserve (FFR)-guided PCI and TAVI is noninferior to combined CABG and SAVR for the treatment of severe AS and multivessel or advanced CAD. METHODS: The Transcatheter Valve and Vessels (TCW) trial (clinicaltrial.gov: NCT03424941) is a prospective, randomized, controlled, open label, international trial. Patients ≥ 70 years with severe AS and multivessel (≥ 2 vessels) or advanced CAD, deemed feasible by the heart team for both; a full percutaneous or surgical treatment, will be randomised in a 1:1 fashion to either FFR-guided PCI followed by TAVI (intervention arm) vs. CABG and SAVR (control arm). The primary endpoint is a patient-oriented composite of all-cause mortality, myocardial infarction, disabling stroke, unscheduled clinically-driven target vessel revascularization, valve reintervention, and life threatening or disabling bleeding at 1 year. The TCW trial is powered for noninferiority, and if met, superiority will be tested. Assuming a primary endpoint rate of 30% in the CABG-SAVR arm, with a significance level α of 5%, a noninferiority limit delta of 15% and a loss to follow-up of 2%, a total of 328 patients are needed to obtain a power of 90%. The primary endpoint analysis is performed on an intention-to-treat basis. SUMMARY: The TCW Trial is the first prospective randomized trial that will study if a less invasive percutaneous treatment for severe AS and concomitant advanced CAD (i.e., FFR-guided PCI-TAVI) is noninferior to the guidelines recommended approach (CABG-SAVR).


Assuntos
Estenose da Valva Aórtica , Doença da Artéria Coronariana , Reserva Fracionada de Fluxo Miocárdico , Intervenção Coronária Percutânea , Substituição da Valva Aórtica Transcateter , Humanos , Doença da Artéria Coronariana/complicações , Doença da Artéria Coronariana/diagnóstico , Doença da Artéria Coronariana/cirurgia , Valva Aórtica/cirurgia , Intervenção Coronária Percutânea/efeitos adversos , Estudos Prospectivos , Ponte de Artéria Coronária , Estenose da Valva Aórtica/complicações , Estenose da Valva Aórtica/diagnóstico , Estenose da Valva Aórtica/cirurgia , Resultado do Tratamento
19.
Rev Esp Cardiol (Engl Ed) ; 77(2): 138-147, 2024 Feb.
Artigo em Inglês, Espanhol | MEDLINE | ID: mdl-37354942

RESUMO

INTRODUCTION AND OBJECTIVES: Catheter-directed therapy (CDT) for acute pulmonary embolism (PE) is an emerging therapy that combines heterogeneous techniques. The aim of the study was to provide a nationwide contemporary snapshot of clinical practice and CDT-related outcomes. METHODS: This Investigator-initiated multicenter registry aimed to include consecutive patients with intermediate-high risk (IHR) or high-risk (HR), acute PE eligible for CDT. The primary outcome of the study was in-hospital all-cause death. RESULTS: A total of 253 patients were included, of whom 93 (36.8%) had HR-PE, and 160 (63.2%) had IHR-PE with a mean age of 62.3±15.1 years. Local thrombolysis was performed in 70.8% and aspiration thrombectomy in 51.8%, with 23.3% of patients receiving both. However, aspiration thrombectomy was favored in the HR-PE cohort (80.6% vs 35%; P<.001). Only 51 patients (20.2%) underwent CDT with specific PE devices. The success rate for CDT was 90.9% (98.1% of IHR-PE patients vs 78.5% of HR-PE patients, P<.001). In-hospital mortality was 15.5%, and was highly concentrated in the HR-PE patients (37.6%) and significantly lower in IHR-PE patients (2.5%), P<.001. Long-term (24-month) mortality was 40.2% in HR-PE patients vs 8.2% in IHR-PE patients (P<.001). CONCLUSIONS: Despite the high success rate for CDT, in-hospital mortality in HR-PE is still high (37.6%) compared with very low IHR-PE mortality (2.5%).


Assuntos
Fibrinolíticos , Embolia Pulmonar , Humanos , Pessoa de Meia-Idade , Idoso , Fibrinolíticos/uso terapêutico , Terapia Trombolítica/métodos , Resultado do Tratamento , Embolia Pulmonar/terapia , Trombectomia/métodos , Catéteres , Sistema de Registros , Estudos Retrospectivos
20.
Clin Res Cardiol ; 113(1): 48-57, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37138103

RESUMO

BACKGROUND: Transaxillary (TAx) transcatheter aortic valve implantation (TAVI) is a preferred alternative access in patients ineligible for transfemoral TAVI. AIMS: This study used the Trans-AXillary Intervention (TAXI) registry to compare procedural success according to different types of transcatheter heart valves (THV). METHODS: For the TAXI registry anonymized data of patients treated with TAx-TAVI were collected from 18 centers. Acute procedural, early and 1-month clinical outcomes were adjudicated in accordance with standardized VARC-3 definitions. RESULTS: From 432 patients, 368 patients (85.3%, SE group) received self-expanding (SE) THV and 64 patients (14.8%, BE group) received balloon-expandable (BE) THV. Imaging revealed lower axillary artery diameters in the SE group (max/min diameter in mm: 8.4/6.6 vs 9.4/6.8 mm; p < 0.001/p = 0.04) but a higher proportion of axillary tortuosity in BE group (62/368, 23.6% vs 26/64, 42.6%; p = 0.004) with steeper aorta-left ventricle (LV) inflow (55° vs 51°; p = 0.002) and left ventricular outflow tract (LVOT)-LV inflow angles (40.0° vs 24.5°; 0.002). TAx-TAVI was more often conducted by right sided axillary artery in the BE group (33/368, 9.0% vs 17/64, 26.6%; p < 0.001). Device success was higher in the SE group (317/368, 86.1% vs 44/64, 68.8%, p = 0.0015). In logistic regression analysis, BE THV were a risk factor for vascular complications and axillary stent implantation. CONCLUSIONS: Both, SE and BE THV can be safely used in TAx-TAVI. However, SE THV were more often used and were associated with a higher rate of device success. While SE THV were associated with lower rates of vascular complications, BE THV were more often used in cases with challenging anatomical circumstances.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/métodos , Estenose da Valva Aórtica/cirurgia , Resultado do Tratamento , Valva Aórtica/cirurgia , Sistema de Registros , Desenho de Prótese
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA