Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 242
Filtrar
1.
Crit Care Sci ; 36: e20240284en, 2024.
Artigo em Inglês, Português | MEDLINE | ID: mdl-38716961

RESUMO

OBJECTIVE: To examine the physical function and respiratory muscle strength of patients - who recovered from critical COVID-19 - after intensive care unit discharge to the ward on Days one (D1) and seven (D7), and to investigate variables associated with functional impairment. METHODS: This was a prospective cohort study of adult patients with COVID-19 who needed invasive mechanical ventilation, non-invasive ventilation or high-flow nasal cannula and were discharged from the intensive care unit to the ward. Participants were submitted to Medical Research Council sum-score, handgrip strength, maximal inspiratory pressure, maximal expiratory pressure, and short physical performance battery tests. Participants were grouped into two groups according to their need for invasive ventilation: the Invasive Mechanical Ventilation Group (IMV Group) and the Non-Invasive Mechanical Ventilation Group (Non-IMV Group). RESULTS: Patients in the IMV Group (n = 31) were younger and had higher Sequential Organ Failure Assessment scores than those in the Non-IMV Group (n = 33). The short physical performance battery scores (range 0 - 12) on D1 and D7 were 6.1 ± 4.3 and 7.3 ± 3.8, respectively for the Non-Invasive Mechanical Ventilation Group, and 1.3 ± 2.5 and 2.6 ± 3.7, respectively for the IMV Group. The prevalence of intensive care unit-acquired weakness on D7 was 13% for the Non-IMV Group and 72% for the IMV Group. The maximal inspiratory pressure, maximal expiratory pressure, and handgrip strength increased on D7 in both groups, but the maximal expiratory pressure and handgrip strength were still weak. Only maximal inspiratory pressure was recovered (i.e., > 80% of the predicted value) in the Non-IMV Group. Female sex, and the need and duration of invasive mechanical were independently and negatively associated with the short physical performance battery score and handgrip strength. CONCLUSION: Patients who recovered from critical COVID-19 and who received invasive mechanical ventilation presented greater disability than those who were not invasively ventilated. However, they both showed marginal functional improvement during early recovery, regardless of the need for invasive mechanical ventilation. This might highlight the severity of disability caused by SARS-CoV-2.


Assuntos
COVID-19 , Unidades de Terapia Intensiva , Respiração Artificial , Sobreviventes , Humanos , COVID-19/epidemiologia , COVID-19/terapia , Masculino , Feminino , Pessoa de Meia-Idade , Estudos Prospectivos , Idoso , Sobreviventes/estatística & dados numéricos , SARS-CoV-2 , Força Muscular , Força da Mão , Músculos Respiratórios/fisiopatologia , Desempenho Físico Funcional
5.
Artigo em Inglês | MEDLINE | ID: mdl-38354065

RESUMO

RATIONALE: It is unknown whether preventing overdistention or collapse is more important when titrating positive end-expiratory pressure (PEEP) in acute respiratory distress syndrome (ARDS). OBJECTIVE: To compare PEEP targeting either minimal overdistention, minimal collapse or using a compromise between collapse and overdistention in a randomized trial, and assess the impact on respiratory mechanics, gas exchange, inflammation, and hemodynamics. METHODS: In a porcine model of ARDS, lung collapse and overdistention were estimated by electrical impedance tomography during a decremental PEEP titration. Pigs were randomized to three groups and ventilated for 12 hours: PEEP set at ≤3% of overdistention (low overdistention); ≤3% of collapse (low collapse); and crossing point of collapse and overdistention (crossing-point). MEASUREMENTS AND MAIN RESULTS: Thirty-six pigs (12/group) were included. Median PEEP were 7(IQR:6-8)cmH2O, 11(10-11)cmH2O, and 15(12-16)cmH2O in the three groups, p<0.001. With low overdistension, 6(50%) pigs died whereas survival was 100% in both other groups. Cause of death was hemodynamic in nature, with high transpulmonary gradient and high epinephrine requirements. Compared to the other groups, pigs surviving with low overdistension had worse respiratory mechanics and gas exchange during the entire protocol. Minimal differences existed between crossing-point and low collapse animals in physiological parameters but postmortem alveolar density was more homogeneous in crossing-point. Inflammatory markers were not significantly different. CONCLUSIONS: PEEP to minimize overdistention resulted in high mortality in an animal model of ARDS. Minimizing collapse or choosing a compromise between collapse and overdistention may result in less lung injury, with potential benefits of the compromise approach.

6.
Anesthesiology ; 140(4): 752-764, 2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-38207290

RESUMO

BACKGROUND: Lower fractional inspired oxygen tension (Fio2) during general anesthesia can reduce lung atelectasis. The objectives are to evaluate the effect of two Fio2 (0.4 and 1) during low positive end-expiratory pressure (PEEP) ventilation over lung perfusion distribution, volume, and regional ventilation. These variables were evaluated at two PEEP levels and unilateral lung atelectasis. METHODS: In this exploratory study, 10 healthy female piglets (32.3 ± 3.4 kg) underwent mechanical ventilation in two atelectasis models: (1) bilateral gravitational atelectasis (n = 6), induced by changes in PEEP and Fio2 in three combinations: high PEEP with low Fio2 (Fio2 = 0.4), zero PEEP (PEEP0) with low Fio2 (Fio2 = 0.4), and PEEP0 with high Fio2 (Fio2 = 1); and (2) unilateral atelectasis (n = 6), induced by left bronchial occlusion, with the left lung aerated (Fio2 = 0.21) and low aerated (Fio2 = 1; n = 5 for this step). Measurements were conducted after 10 min in each step, encompassing assessment of respiratory mechanics, oxygenation, and hemodynamics; lung ventilation and perfusion by electrical impedance tomography; and lung aeration and perfusion by computed tomography. RESULTS: During bilateral gravitational atelectasis, PEEP reduction increased atelectasis in dorsal regions, decreased respiratory compliance, and distributed lung ventilation to ventral regions with a parallel shift of perfusion to the same areas. With PEEP0, there were no differences between low and high Fio2 in respiratory compliance (23.9 ± 6.5 ml/cm H2O vs. 21.9 ± 5.0; P = 0.441), regional ventilation, and regional perfusion, despite higher lung collapse (18.6 ± 7.6% vs. 32.7 ± 14.5%; P = 0.045) with high Fio2. During unilateral lung atelectasis, the deaerated lung had a lower shunt (19.3 ± 3.6% vs. 25.3 ± 5.5%; P = 0.045) and lower computed tomography perfusion to the left lung (8.8 ± 1.8% vs. 23.8 ± 7.1%; P = 0.007). CONCLUSIONS: PEEP0 with low Fio2, compared with high Fio2, did not produce significant changes in respiratory system compliance, regional lung ventilation, and perfusion despite significantly lower lung collapse. After left bronchial occlusion, the shrinkage of the parenchyma with Fio2 = 1 enhanced hypoxic pulmonary vasoconstriction, reducing intrapulmonary shunt and perfusion of the nonventilated areas.


Assuntos
Atelectasia Pulmonar , Respiração Artificial , Animais , Feminino , Suínos , Respiração Artificial/métodos , Pulmão/diagnóstico por imagem , Medidas de Volume Pulmonar , Atelectasia Pulmonar/diagnóstico por imagem , Atelectasia Pulmonar/terapia , Perfusão , Oxigênio
7.
Am J Respir Crit Care Med ; 209(5): 563-572, 2024 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-38190718

RESUMO

Rationale: Hypoxemia during mechanical ventilation might be worsened by expiratory muscle activity, which reduces end-expiratory lung volume through lung collapse. A proposed mechanism of benefit of neuromuscular blockade in acute respiratory distress syndrome (ARDS) is the abolition of expiratory efforts. This may contribute to the restoration of lung volumes. The prevalence of this phenomenon, however, is unknown. Objectives: To investigate the incidence and amount of end-expiratory lung impedance (EELI) increase after the administration of neuromuscular blocking agents (NMBAs), clinical factors associated with this phenomenon, its impact on regional lung ventilation, and any association with changes in pleural pressure. Methods: We included mechanically ventilated patients with ARDS monitored with electrical impedance tomography (EIT) who received NMBAs in one of two centers. We measured changes in EELI, a surrogate for end-expiratory lung volume, before and after NMBA administration. In an additional 10 patients, we investigated the characteristic signatures of expiratory muscle activity depicted by EIT and esophageal catheters simultaneously. Clinical factors associated with EELI changes were assessed. Measurements and Main Results: We included 46 patients, half of whom showed an increase in EELI of >10% of the corresponding Vt (46.2%; IQR, 23.9-60.9%). The degree of EELI increase correlated positively with fentanyl dosage and negatively with changes in end-expiratory pleural pressures. This suggests that expiratory muscle activity might exert strong counter-effects against positive end-expiratory pressure that are possibly aggravated by fentanyl. Conclusions: Administration of NMBAs during EIT monitoring revealed activity of expiratory muscles in half of patients with ARDS. The resultant increase in EELI had a dose-response relationship with fentanyl dosage. This suggests a potential side effect of fentanyl during protective ventilation.


Assuntos
Bloqueadores Neuromusculares , Síndrome do Desconforto Respiratório , Humanos , Respiração com Pressão Positiva/métodos , Pulmão , Respiração Artificial/métodos , Síndrome do Desconforto Respiratório/terapia , Fentanila/uso terapêutico
8.
Physiol Meas ; 45(1)2024 Jan 10.
Artigo em Inglês | MEDLINE | ID: mdl-38086063

RESUMO

Objective. Understanding a patient's respiratory effort and mechanics is essential for the provision of individualized care during mechanical ventilation. However, measurement of transpulmonary pressure (the difference between airway and pleural pressures) is not easily performed in practice. While airway pressures are available on most mechanical ventilators, pleural pressures are measured indirectly by an esophageal balloon catheter. In many cases, esophageal pressure readings take other phenomena into account and are not a reliable measure of pleural pressure.Approach.A system identification approach was applied to provide accurate pleural measures from esophageal pressure readings. First, we used a closed pressurized chamber to stimulate an esophageal balloon and model its dynamics. Second, we created a simplified version of an artificial lung and tried the model with different ventilation configurations. For validation, data from 11 patients (five male and six female) were used to estimate respiratory effort profile and patient mechanics.Main results.After correcting the dynamic response of the balloon catheter, the estimates of resistance and compliance and the corresponding respiratory effort waveform were improved when compared with the adjusted quantities in the test bench. The performance of the estimated model was evaluated using the respiratory pause/occlusion maneuver, demonstrating improved agreement between the airway and esophageal pressure waveforms when using the normalized mean squared error metric. Using the corrected muscle pressure waveform, we detected start and peak times 130 ± 50 ms earlier and a peak amplitude 2.04 ± 1.46 cmH2O higher than the corresponding estimates from esophageal catheter readings.Significance.Compensating the acquired measurements with system identification techniques makes the readings more accurate, possibly better portraying the patient's situation for individualization of ventilation therapy.


Assuntos
Respiração Artificial , Mecânica Respiratória , Humanos , Masculino , Feminino , Pressão , Mecânica Respiratória/fisiologia , Respiração Artificial/métodos , Pulmão , Catéteres
9.
Crit Care Med ; 52(1): 68-79, 2024 01 01.
Artigo em Inglês | MEDLINE | ID: mdl-37695139

RESUMO

OBJECTIVES: High mechanical power and driving pressure (ΔP) have been associated with postoperative respiratory failure (PRF) and may be important parameters guiding mechanical ventilation. However, it remains unclear whether high mechanical power and ΔP merely reflect patients with poor respiratory system mechanics at risk of PRF. We investigated the effect of mechanical power and ΔP on PRF in cohorts after exact matching by patients' baseline respiratory system compliance. DESIGN: Hospital registry study. SETTING: Academic hospital in New England. PATIENTS: Adult patients undergoing general anesthesia between 2008 and 2020. INTERVENTION: None. MEASUREMENTS AND MAIN RESULTS: The primary exposure was high (≥ 6.7 J/min, cohort median) versus low mechanical power and the key-secondary exposure was high (≥ 15.0 cm H 2 O) versus low ΔP. The primary endpoint was PRF (reintubation or unplanned noninvasive ventilation within seven days). Among 97,555 included patients, 4,030 (4.1%) developed PRF. In adjusted analyses, high intraoperative mechanical power and ΔP were associated with higher odds of PRF (adjusted odds ratio [aOR] 1.37 [95% CI, 1.25-1.50]; p < 0.001 and aOR 1.45 [95% CI, 1.31-1.60]; p < 0.001, respectively). There was large variability in applied ventilatory parameters, dependent on the anesthesia provider. This facilitated matching of 63,612 (mechanical power cohort) and 53,260 (ΔP cohort) patients, yielding identical baseline standardized respiratory system compliance (standardized difference [SDiff] = 0.00) with distinctly different mechanical power (9.4 [2.4] vs 4.9 [1.3] J/min; SDiff = -2.33) and ΔP (19.3 [4.1] vs 11.9 [2.1] cm H 2 O; SDiff = -2.27). After matching, high mechanical power and ΔP remained associated with higher risk of PRF (aOR 1.30 [95% CI, 1.17-1.45]; p < 0.001 and aOR 1.28 [95% CI, 1.12-1.46]; p < 0.001, respectively). CONCLUSIONS: High mechanical power and ΔP are associated with PRF independent of patient's baseline respiratory system compliance. Our findings support utilization of these parameters for titrating mechanical ventilation in the operating room and ICU.


Assuntos
Respiração Artificial , Insuficiência Respiratória , Adulto , Humanos , Mecânica Respiratória , Sistema Respiratório , Insuficiência Respiratória/epidemiologia , New England , Volume de Ventilação Pulmonar
10.
Am J Respir Crit Care Med ; 209(6): 670-682, 2024 Mar 15.
Artigo em Inglês | MEDLINE | ID: mdl-38127779

RESUMO

Hypoxemic respiratory failure is one of the leading causes of mortality in intensive care. Frequent assessment of individual physiological characteristics and delivery of personalized mechanical ventilation (MV) settings is a constant challenge for clinicians caring for these patients. Electrical impedance tomography (EIT) is a radiation-free bedside monitoring device that is able to assess regional lung ventilation and changes in aeration. With real-time tomographic functional images of the lungs obtained through a thoracic belt, clinicians can visualize and estimate the distribution of ventilation at different ventilation settings or following procedures such as prone positioning. Several studies have evaluated the performance of EIT to monitor the effects of different MV settings in patients with acute respiratory distress syndrome, allowing more personalized MV. For instance, EIT could help clinicians find the positive end-expiratory pressure that represents a compromise between recruitment and overdistension and assess the effect of prone positioning on ventilation distribution. The clinical impact of the personalization of MV remains to be explored. Despite inherent limitations such as limited spatial resolution, EIT also offers a unique noninvasive bedside assessment of regional ventilation changes in the ICU. This technology offers the possibility of a continuous, operator-free diagnosis and real-time detection of common problems during MV. This review provides an overview of the functioning of EIT, its main indices, and its performance in monitoring patients with acute respiratory failure. Future perspectives for use in intensive care are also addressed.


Assuntos
Síndrome do Desconforto Respiratório , Insuficiência Respiratória , Humanos , Impedância Elétrica , Tomografia Computadorizada por Raios X/métodos , Pulmão , Insuficiência Respiratória/diagnóstico por imagem , Insuficiência Respiratória/terapia , Tomografia/métodos , Síndrome do Desconforto Respiratório/diagnóstico por imagem , Síndrome do Desconforto Respiratório/terapia
11.
Ann Intensive Care ; 13(1): 131, 2023 Dec 20.
Artigo em Inglês | MEDLINE | ID: mdl-38117367

RESUMO

BACKGROUND: Internal redistribution of gas, referred to as pendelluft, is a new potential mechanism of effort-dependent lung injury. Neurally-adjusted ventilatory assist (NAVA) and proportional assist ventilation (PAV +) follow the patient's respiratory effort and improve synchrony compared with pressure support ventilation (PSV). Whether these modes could prevent the development of pendelluft compared with PSV is unknown. We aimed to compare pendelluft magnitude during PAV + and NAVA versus PSV in patients with resolving acute respiratory distress syndrome (ARDS). METHODS: Patients received either NAVA, PAV + , or PSV in a crossover trial for 20-min using comparable assistance levels after controlled ventilation (> 72 h). We assessed pendelluft (the percentage of lost volume from the non-dependent lung region displaced to the dependent region during inspiration), drive (as the delta esophageal swing of the first 100 ms [ΔPes 100 ms]) and inspiratory effort (as the esophageal pressure-time product per minute [PTPmin]). We performed repeated measures analysis with post-hoc tests and mixed-effects models. RESULTS: Twenty patients mechanically ventilated for 9 [5-14] days were monitored. Despite matching for a similar tidal volume, respiratory drive and inspiratory effort were slightly higher with NAVA and PAV + compared with PSV (ΔPes 100 ms of -2.8 [-3.8--1.9] cm H2O, -3.6 [-3.9--2.4] cm H2O and -2.1 [-2.5--1.1] cm H2O, respectively, p < 0.001 for both comparisons; PTPmin of 155 [118-209] cm H2O s/min, 197 [145-269] cm H2O s/min, and 134 [93-169] cm H2O s/min, respectively, p < 0.001 for both comparisons). Pendelluft magnitude was higher in NAVA (12 ± 7%) and PAV + (13 ± 7%) compared with PSV (8 ± 6%), p < 0.001. Pendelluft magnitude was strongly associated with respiratory drive (ß = -2.771, p-value < 0.001) and inspiratory effort (ß = 0.026, p < 0.001), independent of the ventilatory mode. A higher magnitude of pendelluft in proportional modes compared with PSV existed after adjusting for PTPmin (ß = 2.606, p = 0.010 for NAVA, and ß = 3.360, p = 0.004 for PAV +), and only for PAV + when adjusted for respiratory drive (ß = 2.643, p = 0.009 for PAV +). CONCLUSIONS: Pendelluft magnitude is associated with respiratory drive and inspiratory effort. Proportional modes do not prevent its occurrence in resolving ARDS compared with PSV.

13.
Crit Care ; 27(1): 457, 2023 11 24.
Artigo em Inglês | MEDLINE | ID: mdl-38001485

RESUMO

BACKGROUND: In the acute distress respiratory syndrome (ARDS), specific lung regions can be exposed to excessive strain due to heterogeneous disease, gravity-dependent lung collapse and injurious mechanical ventilation. Computed tomography (CT) is the gold standard for regional strain assessment. An alternative tool could be the electrical impedance tomography (EIT). We aimed to determine whether EIT-based methods can predict the dynamic relative regional strain (DRRS) between two levels of end-expiratory pressure (PEEP) in gravity-non-dependent and dependent lung regions. METHODS: Fourteen ARDS patients underwent CT and EIT acquisitions (at end-inspiratory and end-expiratory) at two levels of PEEP: a low-PEEP based on ARDS-net strategy and a high-PEEP titrated according to EIT. Three EIT-based methods for DRRS were compared to relative CT-based strain: (1) the change of the ratio between EIT ventilation and end-expiratory lung impedance in arbitrary units ([ΔZAU low-PEEP/EELIAU low-PEEP]/[ΔZAU high-PEEP/EELIAU high-PEEP]), (2) the change of ΔZ/EELI ratio calibrated to mL ([ΔZml low-PEEP/EELIml low-PEEP]/[ΔZml high-PEEP/EELIml high-PEEP]) using CT data, and (3) the relative change of ∆ZAU (∆ZAU low-PEEP/∆ZAU high-PEEP). We performed linear regressions analysis and calculated bias and limits of agreement to assess the performance of DRRS by EIT in comparison with CT. RESULTS: The DRRS assessed by (ΔZml low-PEEP/EELIml low-PEEP)/(ΔZml high-PEEP/EELIml high-PEEP) and ∆ZAU low-PEEP/∆ZAU high-PEEP showed good relationship and agreement with the CT method (R2 of 0.9050 and 0.8679, respectively, in non-dependent region; R2 of 0.8373 and 0.6588, respectively, in dependent region; biases ranging from - 0.11 to 0.51 and limits of agreement ranging from - 0.73 to 1.16 for both methods and lung regions). Conversely, DRRS based on EELIAU ([ΔZAU low-PEEP/EELIAU low-PEEP]/[ΔZAU high-PEEP/EELIAU high-PEEP]) exhibited a weak negative relationship and poor agreement with the CT method for both non-dependent and dependent regions (R2 ~ 0.3; bias of 3.11 and 2.08, and limits of agreement of - 2.13 to 8.34 and from - 1.49 to 5.64, respectively). CONCLUSION: Changes in DRRS during a PEEP trial in ARDS patients could be monitored using EIT, based on changes in ΔZmL/EELIml and ∆ZAU. The relative change ∆ZAU offers the advantage of not requiring CT data for calibration.


Assuntos
Respiração com Pressão Positiva , Síndrome do Desconforto Respiratório , Humanos , Impedância Elétrica , Respiração com Pressão Positiva/métodos , Pulmão/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Síndrome do Desconforto Respiratório/diagnóstico por imagem , Tomografia/métodos
15.
Crit Care Explor ; 5(10): e0983, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37795456

RESUMO

OBJECTIVES: Experimental models suggest that prone position and positive end-expiratory pressure (PEEP) homogenize ventral-dorsal ventilation distribution and regional respiratory compliance. However, this response still needs confirmation on humans. Therefore, this study aimed to assess the changes in global and regional respiratory mechanics in supine and prone positions over a range of PEEP levels in acute respiratory distress syndrome (ARDS) patients. DESIGN: A prospective cohort study. PATIENTS: Twenty-two intubated patients with ARDS caused by COVID-19 pneumonia. INTERVENTIONS: Electrical impedance tomography and esophageal manometry were applied during PEEP titrations from 20 cm H2O to 6 cm H2O in supine and prone positions. MEASUREMENTS: Global respiratory system compliance (Crs), chest wall compliance, regional lung compliance, ventilation distribution in supine and prone positions. MAIN RESULTS: Compared with supine position, the maximum level of Crs changed after prone position in 59% of ARDS patients (n = 13), of which the Crs decreased in 32% (n = 7) and increased in 27% (n = 6). To reach maximum Crs after pronation, PEEP was changed in 45% of the patients by at least 4 cm H2O. After pronation, the ventilation and compliance of the dorsal region did not consistently change in the entire sample of patients, increasing specifically in a subgroup of patients who showed a positive change in Crs when transitioning from supine to prone position. These combined changes in ventilation and compliance suggest dorsal recruitment postpronation. In addition, the subgroup with increased Crs postpronation demonstrated the most pronounced difference between dorsal and ventral ventilation distribution from supine to prone position (p = 0.01), indicating heterogeneous ventilation distribution in prone position. CONCLUSIONS: Prone position modifies global respiratory compliance in most patients with ARDS. Only a subgroup of patients with a positive change in Crs postpronation presented a consistent improvement in dorsal ventilation and compliance. These data suggest that the response to pronation on global and regional mechanics can vary among ARDS patients, with some patients presenting more dorsal lung recruitment than others.

16.
World Neurosurg ; 179: e557-e567, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37690580

RESUMO

BACKGROUND: Neurological complications during full-endoscopic spine surgery (FESS) might be attributed to intracranial pressure (ICP) increase due to continuous saline infusion (CSI). Understanding CSI and ICP correlation might modify irrigation pump usage. This study aimed to evaluate invasive ICP during interlaminar FESS; correlate ICP with irrigation pump parameters (IPPs); evaluate ICP during saline outflow occlusion, commonly used to control bleeding and improve the surgeon's view; and, after durotomy, simulate accidental dural tear. METHODS: Five swine were monitored, submitted to total intravenous anesthesia, and positioned ventrally. A parenchymal catheter was installed through a skull burr for ICP monitoring. Lumbar interlaminar FESS was performed until exposure of neural structures. CSI was used within progressively higher IPPs (A [60 mm Hg, 350 mL/minute] to D [150 mm Hg, 700 mL/minute]), and ICP was documented. During each IPP, different situations were grouped: intact dura with open channels (A1-D1) or occlusion test (A2-D2); dural tear with open channels (Ax1-Dx1) or occlusion test (Ax2-Dx2). ICP <20 mm Hg was defined as safe. RESULTS: Basal average ICP was 8.1 mm Hg. Adjustment in total intravenous anesthesia or suspension of tests was necessary due to critical ICP or animal discomfort. It was safe to operate with all IPPs with opened drainage channels (A1-D1) even with dural tear (Ax1-Dx1). Several occlusion tests (A2-D2, Ax2-Dx2) caused ICP increase (e.g., 86.1 mm Hg) influenced by anesthetic state and hemodynamics. CONCLUSIONS: During FESS, CSI might critically raise ICP. Keeping drainage channels open, with ideal anesthetic state, ICP remains safe even with high IPPs, despite dural tear. Drainage occlusions can quickly raise ICP, being even more severe with higher IPPs. Total intravenous anesthesia may protect from ICP increase and may allow longer drainage occlusion or higher IPPs.


Assuntos
Anestésicos , Hipertensão Intracraniana , Animais , Suínos , Pressão Intracraniana , Endoscopia , Procedimentos Neurocirúrgicos , Anestesia Geral , Hipertensão Intracraniana/etiologia
17.
Anesthesiology ; 139(6): 815-826, 2023 12 01.
Artigo em Inglês | MEDLINE | ID: mdl-37566686

RESUMO

BACKGROUND: Bedside electrical impedance tomography could be useful to visualize evolving pulmonary perfusion distributions when acute respiratory distress syndrome worsens or in response to ventilatory and positional therapies. In experimental acute respiratory distress syndrome, this study evaluated the agreement of electrical impedance tomography and dynamic contrast-enhanced computed tomography perfusion distributions at two injury time points and in response to increased positive end-expiratory pressure (PEEP) and prone position. METHODS: Eleven mechanically ventilated (VT 8 ml · kg-1) Yorkshire pigs (five male, six female) received bronchial hydrochloric acid (3.5 ml · kg-1) to invoke lung injury. Electrical impedance tomography and computed tomography perfusion images were obtained at 2 h (early injury) and 24 h (late injury) after injury in supine position with PEEP 5 and 10 cm H2O. In eight animals, electrical impedance tomography and computed tomography perfusion imaging were also conducted in the prone position. Electrical impedance tomography perfusion (QEIT) and computed tomography perfusion (QCT) values (as percentages of image total) were compared in eight vertical regions across injury stages, levels of PEEP, and body positions using mixed-effects linear regression. The primary outcome was agreement between QEIT and QCT, defined using limits of agreement and Pearson correlation coefficient. RESULTS: Pao2/Fio2 decreased over the course of the experiment (healthy to early injury, -253 [95% CI, -317 to -189]; early to late injury, -88 [95% CI, -151 to -24]). The limits of agreement between QEIT and QCT were -4.66% and 4.73% for the middle 50% quantile of average regional perfusion, and the correlation coefficient was 0.88 (95% CI, 0.86 to 0.90]; P < 0.001). Electrical impedance tomography and computed tomography showed similar perfusion redistributions over injury stages and in response to increased PEEP. QEIT redistributions after positional therapy underestimated QCT in ventral regions and overestimated QCT in dorsal regions. CONCLUSIONS: Electrical impedance tomography closely approximated computed tomography perfusion measures in experimental acute respiratory distress syndrome, in the supine position, over injury progression and with increased PEEP. Further validation is needed to determine the accuracy of electrical impedance tomography in measuring perfusion redistributions after positional changes.


Assuntos
Síndrome do Desconforto Respiratório , Tomografia Computadorizada por Raios X , Masculino , Feminino , Suínos , Animais , Impedância Elétrica , Síndrome do Desconforto Respiratório/terapia , Pulmão , Perfusão , Tomografia/métodos
20.
J Appl Physiol (1985) ; 135(3): 500-507, 2023 09 01.
Artigo em Inglês | MEDLINE | ID: mdl-37439236

RESUMO

Management of acute respiratory distress syndrome (ARDS) is classically guided by protecting the injured lung and mitigating damage from mechanical ventilation. Yet the natural history of ARDS is also dictated by disruption in lung perfusion. Unfortunately, diagnosis and treatment are hampered by the lack of bedside perfusion monitoring. Electrical impedance tomography is a portable imaging technique that can estimate regional lung perfusion in experimental settings from the kinetic analysis of a bolus of an indicator with high conductivity. Hypertonic sodium chloride has been the standard indicator. However, hypertonic sodium chloride is often inaccessible in the hospital, limiting practical adoption. We investigated whether regional lung perfusion measured using electrical impedance tomography is comparable between indicators. Using a swine lung injury model, we determined regional lung perfusion (% of total perfusion) in five pigs, comparing 12% sodium chloride to 8.4% sodium bicarbonate across stages of lung injury and experimental conditions (body position, positive end-expiratory pressure). Regional lung perfusion for four lung regions was determined from maximum slope analysis of the indicator-based impedance signal. Estimates of regional lung perfusion between indicators were compared in the lung overall and within four lung regions. Regional lung perfusion estimated with a sodium bicarbonate indicator agreed with a hypertonic sodium chloride indicator overall (mean bias 0%, limits of agreement -8.43%, 8.43%) and within lung quadrants. The difference in regional lung perfusion between indicators did not change across experimental conditions. Sodium bicarbonate may be a comparable indicator to estimate regional lung perfusion using electrical impedance tomography.NEW & NOTEWORTHY Electrical impedance tomography is an emerging tool to measure regional lung perfusion using kinetic analysis of a conductive indicator. Hypertonic sodium chloride is the standard agent used. We measured regional lung perfusion using another indicator, comparing hypertonic sodium chloride to sodium bicarbonate in an experimental swine lung injury model. We found strong agreement between the two indicators. Sodium bicarbonate may be a comparable indicator to measure regional lung perfusion with electrical impedance tomography.


Assuntos
Lesão Pulmonar , Síndrome do Desconforto Respiratório , Suínos , Animais , Impedância Elétrica , Cinética , Bicarbonato de Sódio , Cloreto de Sódio , Pulmão/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Síndrome do Desconforto Respiratório/terapia , Perfusão , Tomografia/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA