Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 16 de 16
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
Radiat Prot Dosimetry ; 199(15-16): 1910-1916, 2023 Oct 11.
Artigo em Inglês | MEDLINE | ID: mdl-37819290

RESUMO

ELI Beamlines is one of the pillars of the Extreme Light Infrastructure European Research Infrastructure Consortium (ELI ERIC), the European project aiming at building the next generation of high power lasers for fundamental research and industrial applications. Several high-power lasers are hosted by the ELI Beamlines facility. Even at a power lower than the nominal one, when interacting with a target, the laser can generate mixed ionizing radiation fields of unique nature. One of the major laser systems, High-repetition-rate advanced petawatt laser system (HAPLS) was already used in commissioning experiments. Detecting the neutrons generated during these experiments has been a challenging task, since certain difficulties were faced. First, the experimental conditions were frequently altered during the commissioning phase (such as laser beam parameters, experimental geometry or target type). Next, the extremely short duration of the ionizing radiation pulse generated by the laser (~10-14 s) complicated the correct interpretation of the data provided by the detectors designed and calibrated in standard fields. Here, one commissioning experiment is described, together with the means of addressing the problem of the detection of the ionizing radiation and the lessons learned in this endeavour.


Assuntos
Radiação Ionizante , Síncrotrons , Lasers , Nêutrons
2.
Radiat Prot Dosimetry ; 199(15-16): 2041-2046, 2023 Oct 11.
Artigo em Inglês | MEDLINE | ID: mdl-37819338

RESUMO

When primary space radiation particles enter into the atmosphere of the Earth, they generate showers of secondary radiation. The intensity of secondary radiation reaches its maximum, called the Regener-Pfotzer maximum; its exact position depends on the geomagnetic effective vertical cut-off rigidity, the phase of the solar cycle and also on the type of detected particles. In this paper, several balloon flight experiments are described focusing on the study of the latitudinal effect on the position of the Regener-Pfotzer maximum. Altitude profile of ionization in the atmosphere was measured using radiation detectors flown during several flights at locations with different effective vertical cut-off rigidities (flight HEMERA over Sweden and flights FIK-5 and FIK-6 over Czech Republic). The measured results are supplemented also with simulations using EXPACS 4.11 and the variation of obtained positions of Regener-Pfotzer maximum is discussed.


Assuntos
Radiação Cósmica , Monitoramento de Radiação , Voo Espacial , República Tcheca , Doses de Radiação , Suécia , Aeronaves , Monitoramento de Radiação/métodos , Atividade Solar
3.
Radiat Prot Dosimetry ; 198(9-11): 712-719, 2022 Aug 22.
Artigo em Inglês | MEDLINE | ID: mdl-36005953

RESUMO

Stratospheric balloons are a useful tool for the investigation of cosmic radiation at high altitudes and the tests of new detectors of cosmic radiation. Due to necessary data processing, the balloon gondola needs to carry, together with radiation detectors, additional supplementary sensors measuring humidity, temperature, location and orientation, altitude, atmospheric pressure, acceleration, etc. A newly developed universal system TF-ATMON, based on using already existing tools of the PX4 open-source project, enables apart from data recording and monitoring, also the possibility to trace the balloon gondola after the flight. The application was demonstrated on stratospheric balloon flight FIK-6. This flight was unique because three different types of radiation detectors were used at one flight. It enabled us to compare the altitude of the Regener-Pfotzer maximum measured with different types of sensors sensitive to a different type of secondary cosmic radiation generated in the atmosphere.


Assuntos
Radiação Cósmica , Monitoramento de Radiação , Aeronaves , Altitude , Doses de Radiação , Telemetria
4.
Radiat Prot Dosimetry ; 198(9-11): 670-674, 2022 Aug 22.
Artigo em Inglês | MEDLINE | ID: mdl-36005969

RESUMO

The Microtron MT25 is a cyclic electron accelerator with a Kapitza resonator, maximum beam energy of 25 MeV, standard repetition frequency of 423 Hz, pulse length of 3.5 µs and mean current of 30 µA. Studies at conventional particle accelerators allow to understand the response of dosemeters in known and controllable radiation fields. Subsequently, it is possible to develop models and predict their behavior in complex radiation fields, such as those generated at laser and FLASH facilities. Therefore, response of thermally and optically stimulated luminescence detectors outside of the beam was studied at the Microtron MT25. The detectors were placed on a Plexiglas phantom inside a lead and iron bunker to shield-off background radiation. In addition, GAFChromic™ films and track detectors were used. Two irradiations were performed: with and without an 8-cm thick polyethylene moderator. This paper presents a comparison of the responses of the different detection systems.


Assuntos
Elétrons , Aceleradores de Partículas , Luminescência , Imagens de Fantasmas
5.
Radiat Prot Dosimetry ; 198(9-11): 597-603, 2022 Aug 22.
Artigo em Inglês | MEDLINE | ID: mdl-36005970

RESUMO

Silicon detectors such as Liulin and AIRDOS are used for cosmic radiation measurements onboard aircraft. These measurements can be used for the verification of computer programs assessing aircraft crew radiation exposure. Recently performed intercomparison flights showed large variances of absorbed doses among individual detectors and significant differences between results of silicon detectors and computer programs. In order to explain for these differences, we have developed energy calibration method that can be performed on short flights. The method is based on cross-calibration of Liulin and AIRDOS deposited energy spectra with deposited energy spectra measured by Timepix which has superior detection properties in terms of energy resolution and the detection threshold. Moreover, the portion of dose which is omitted due to low sensitivity for low-energy deposits was calculated. The resulting absorbed dose rates at two intercomparison flights show significantly improved variation of results and better agreement with modelled absorbed dose rates.


Assuntos
Radiação Cósmica , Exposição Ocupacional , Monitoramento de Radiação , Aeronaves , Altitude , Calibragem , Exposição Ocupacional/análise , Doses de Radiação , Monitoramento de Radiação/métodos , Radiometria/métodos , Silício
6.
Radiat Prot Dosimetry ; 198(9-11): 604-610, 2022 Aug 22.
Artigo em Inglês | MEDLINE | ID: mdl-36005975

RESUMO

At the flight altitudes of modern airplanes, cosmic rays intensity is several times higher than on the Earth's surface. The radiation field is not constant in time and due to various effects, not routinely considered in calculations, the exposure can increase several times. Therefore, a continuous monitoring of radiation exposure on board is required. This article characterises newly developed detectors Airdos-C with diverse scintillation crystals. Unlike detectors based on a Si diode, which are commonly used for long-term measurements, these detectors can also be used for detection of high-energy gamma-rays generated in thunderstorms. For a correct interpretation of the measured data it is important to perform an energy calibration and to verify the detector response in known radiation fields. The results obtained with several radionuclide sources were analysed using mathematical statistics methods. The detectors were also exposed onboard aircraft under well-defined conditions.

7.
Radiat Prot Dosimetry ; 198(9-11): 611-616, 2022 Aug 22.
Artigo em Inglês | MEDLINE | ID: mdl-36005980

RESUMO

A new Open-Source dosemeter, SPACEDOS, has been developed for measurements of cosmic radiation on board spacecraft and small satellites. Its main advantages are that it is small and lightweight with low power consumption. It can be adjusted for specific applications, e.g. used in pressurized cabins of spacecraft or in vacuum environments in CubeSats or larger satellites. The open-source design enables better portability and reproduction of the results than other similar detectors. The detector has already successfully performed measurements on board the International Space Station. The obtained results are discussed and compared with those measured with thermoluminescent detectors located in the same position as SPACEDOS.


Assuntos
Radiação Cósmica , Monitoramento de Radiação , Voo Espacial , Doses de Radiação , Monitoramento de Radiação/métodos , Astronave , Dosimetria Termoluminescente
8.
Radiat Prot Dosimetry ; 198(9-11): 623-627, 2022 Aug 22.
Artigo em Inglês | MEDLINE | ID: mdl-36005989

RESUMO

Lomnický stít, Slovakia, 2634 m above sea level, is known to be a place of extreme electric fields measured during thunderstorms and is thus a suitable place for thunderstorm-related ionising radiation research. We present one of the strongest Thunderstorm ground enhancements (TGE) ever detected, which occurred on 12 September 2021. The TGE was detected with the SEVAN detector and also with the new Georadis RT-56 large volume gamma spectrometer. In the paper, we present spectra of the TGE measured with the spectrometer as well as SEVAN coincidence data supplemented by the data from electric field mill.

9.
Front Oncol ; 12: 904563, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35957900

RESUMO

Since 2010, EURADOS Working Group 9 (Radiation Dosimetry in Radiotherapy) has been involved in the investigation of secondary and scattered radiation doses in X-ray and proton therapy, especially in the case of pediatric patients. The main goal of this paper is to analyze and compare out-of-field neutron and non-neutron organ doses inside 5- and 10-year-old pediatric anthropomorphic phantoms for the treatment of a 5-cm-diameter brain tumor. Proton irradiations were carried out at the Cyclotron Centre Bronowice in IFJ PAN Krakow Poland using a pencil beam scanning technique (PBS) at a gantry with a dedicated scanning nozzle (IBA Proton Therapy System, Proteus 235). Thermoluminescent and radiophotoluminescent dosimeters were used for non-neutron dose measurements while secondary neutrons were measured with track-etched detectors. Out-of-field doses measured using intensity-modulated proton therapy (IMPT) were compared with previous measurements performed within a WG9 for three different photon radiotherapy techniques: 1) intensity-modulated radiation therapy (IMRT), 2) three-dimensional conformal radiation therapy (3D CDRT) performed on a Varian Clinac 2300 linear accelerator (LINAC) in the Centre of Oncology, Krakow, Poland, and 3) Gamma Knife surgery performed on the Leksell Gamma Knife (GK) at the University Hospital Centre Zagreb, Croatia. Phantoms and detectors used in experiments as well as the target location were the same for both photon and proton modalities. The total organ dose equivalent expressed as the sum of neutron and non-neutron components in IMPT was found to be significantly lower (two to three orders of magnitude) in comparison with the different photon radiotherapy techniques for the same delivered tumor dose. For IMPT, neutron doses are lower than non-neutron doses close to the target but become larger than non-neutron doses further away from the target. Results of WG9 studies have provided out-of-field dose levels required for an extensive set of radiotherapy techniques, including proton therapy, and involving a complete description of organ doses of pediatric patients. Such studies are needed for validating mathematical models and Monte Carlo simulation tools for out-of-field dosimetry which is essential for dedicated epidemiological studies which evaluate the risk of second cancers and other late effects for pediatric patients treated with radiotherapy.

10.
Med Phys ; 49(4): 2672-2683, 2022 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-35090187

RESUMO

PURPOSE: Craniospinal irradiation (CSI) has greatly increased survival rates for patients with a diagnosis of medulloblastoma and other primitive neuroectodermal tumors. However, as it includes exposure of a large volume of healthy tissue to unwanted doses, there is a strong concern about the complications of the treatment, especially for the children. To estimate the risk of second cancers and other unwanted effects, out-of-field dose assessment is necessary. The purpose of this study is to evaluate and compare out-of-field doses in pediatric CSI treatment using conventional and advanced photon radiotherapy (RT) and advanced proton therapy. To our knowledge, it is the first such comparison based on in-phantom measurements. Additionally, for out-of-field doses during photon RT in this and other studies, comparisons were made using analytical modeling. METHODS: In order to describe the out-of-field doses absorbed in a pediatric patient during actual clinical treatment, an anthropomorphic phantom, which mimics the 10-year-old child, was used. Photon 3D-conformal RT (3D-CRT) and two advanced, highly conformal techniques: photon volumetric-modulated arc therapy (VMAT) and active pencil beam scanning (PBS) proton RT were used for CSI treatment. Radiophotoluminescent and poly-allyl-diglycol-carbonate nuclear track detectors were used for photon and neutron dosimetry in the phantom, respectively. Out-of-field doses from neutrons were expressed in terms of dose equivalent. A two-Gaussian model was implemented for out-of-field doses during photon RT. RESULTS: The mean VMAT photon doses per target dose to all organs in this study were under 50% of the target dose (i.e., <500 mGy/Gy), while the mean 3D-CRT photon dose to oesophagus, gall bladder, and thyroid, exceeded that value. However, for 3D-CRT, better sparing was achieved for eyes and lungs. The mean PBS photon doses for all organs were up to three orders of magnitude lower compared to VMAT and 3D-CRT and exceeded 10 mGy/Gy only for the oesophagus, intestine, and lungs. The mean neutron dose equivalent during PBS for eight organs of interest (thyroid, breasts, lungs, liver, stomach, gall bladder, bladder, prostate) ranged from 1.2 mSv/Gy for bladder to 23.1 mSv/Gy for breasts. Comparison of out-of-field doses in this and other phantom studies found in the literature showed that a simple and fast two-Gaussian model for out-of-field doses as a function of distance from the field edge can be applied in a CSI using photon RT techniques. CONCLUSIONS: PBS is the most promising technique for out-of-field dose reduction in comparison to photon techniques. Among photon techniques, VMAT is a preferred choice for most of out-of-field organs and especially for the thyroid, while doses for eyes, breasts, and lungs are lower for 3D-CRT. For organs outside the field edge, a simple analytical model can be helpful for clinicians involved in treatment planning using photon RT but also for retrospective data analysis for cancer risk estimates and epidemiology in general.


Assuntos
Neoplasias Cerebelares , Radiação Cranioespinal , Radioterapia Conformacional , Radioterapia de Intensidade Modulada , Neoplasias Cerebelares/radioterapia , Criança , Radiação Cranioespinal/efeitos adversos , Radiação Cranioespinal/métodos , Humanos , Masculino , Órgãos em Risco/efeitos da radiação , Prótons , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia Conformacional/métodos , Radioterapia de Intensidade Modulada/efeitos adversos , Radioterapia de Intensidade Modulada/métodos , Estudos Retrospectivos
11.
Phys Med ; 80: 134-150, 2020 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-33181444

RESUMO

UHDpulse - Metrology for advanced radiotherapy using particle beams with ultra-high pulse dose rates is a recently started European Joint Research Project with the aim to develop and improve dosimetry standards for FLASH radiotherapy, very high energy electron (VHEE) radiotherapy and laser-driven medical accelerators. This paper gives a short overview about the current state of developments of radiotherapy with FLASH electrons and protons, very high energy electrons as well as laser-driven particles and the related challenges in dosimetry due to the ultra-high dose rate during the short radiation pulses. We summarize the objectives and plans of the UHDpulse project and present the 16 participating partners.


Assuntos
Elétrons , Radiometria , Lasers , Aceleradores de Partículas , Prótons , Radioterapia , Dosagem Radioterapêutica , Radioterapia de Alta Energia
12.
Radiat Prot Dosimetry ; 186(2-3): 229-234, 2019 Dec 31.
Artigo em Inglês | MEDLINE | ID: mdl-31834927

RESUMO

Neutron detection using nuclear emulsions can offer an alternative in personal dosimetry. The production of emulsions and their quality have to be well controlled with respect to their application in dosimetry. Nuclear emulsions consist mainly of gelatin and silver halide. Gelatin contains a significant amount of hydrogen, which can be used for fast neutron detection. The addition of B-10 in the emulsion is convenient for thermal neutron detection. In this paper, standard nuclear emulsions BR-2 and nuclear emulsions BR-2 enriched with boron produced at the Slavich Company, Russia, were applied for evaluation of fast and thermal neutron fluences. The results were obtained by calculation from the presumed emulsion composition without prior calibration. Evidence that nuclear emulsions used in the experiment are suitable for neutron dosimetry is provided.


Assuntos
Emulsões , Nêutrons Rápidos , Nêutrons , Radiometria/instrumentação , Boro/química , Brometos/química , Calibragem , Gelatina/química , Hélio/análise , Hidrogênio/química , Processamento de Imagem Assistida por Computador , Lítio/análise , Imagens de Fantasmas , Radiometria/métodos , Compostos de Prata/química
13.
Radiat Prot Dosimetry ; 186(2-3): 219-223, 2019 Dec 31.
Artigo em Inglês | MEDLINE | ID: mdl-31702766

RESUMO

Track-etched detectors are commonly used also for radiation monitoring onboard International Space Station. To be registered in track-etched detectors, the particle needs to meet several criteria-it must have linear energy transfer above the detection threshold and strike the detector's surface under an angle higher than the so-called critical angle. Linear energy transfer is then estimated from calibration curve from the etch rate ratio V that is calculated from parameters of individual tracks appearing on the detector's surface after chemical etching. It has been observed that V can depend on the incident angle and this dependence can vary for different detector materials, etching and evaluating conditions. To investigate angular dependence, detectors (Harzlas TD-1) were irradiated at HIMAC by several ions under angles from 0° to 90°. The correction accounting not only for critical angle but also for dependence of V on the incident angle is introduced and applied to spectra measured onboard International Space Station.


Assuntos
Íons Pesados , Monitoramento de Radiação/instrumentação , Astronave , Dosimetria Termoluminescente/instrumentação , Calibragem , Radiação Cósmica , Íons , Transferência Linear de Energia , Doses de Radiação , Monitoramento de Radiação/métodos , Voo Espacial/instrumentação , Dosimetria Termoluminescente/métodos
14.
Radiat Prot Dosimetry ; 186(2-3): 224-228, 2019 Dec 31.
Artigo em Inglês | MEDLINE | ID: mdl-31711193

RESUMO

Long-term measurements using silicon radiation spectrometer Liulin on board commercial aircraft have been performed since 2001; results were put into a new database, which covers more than 4500 flights with more than 130 000 measurements. Methodology and tools were developed to normalize the data with respect to latitude and altitude and thus enable comparison with other radiation detectors and with model calculations. This capability is demonstrated using data from the neutron monitor at Lomnický stít. Instead of providing data files for individual measurement period, two software solutions are delivered. First is a web-based user interface for visualizing and downloading arbitrary time window of interest from the database hosted at http://cr10.odz.ujf.cas.cz. The second is a set of interactive Python notebooks available at GitHub. Those implement the calibration, normalization and visualization methods-so the outputs can be tailored to user needs. The software and data are provided under GNU/CC license.


Assuntos
Aeronaves , Altitude , Radiação Cósmica , Nêutrons , Monitoramento de Radiação/estatística & dados numéricos , Silício/química , Medicina Aeroespacial , Aviação , Calibragem , Bases de Dados Factuais , Geografia , Internet , Doses de Radiação , Exposição à Radiação , Software , Atividade Solar
15.
Astrobiology ; 19(9): 1167-1176, 2019 09.
Artigo em Inglês | MEDLINE | ID: mdl-31161957

RESUMO

To sustain human deep space exploration or extra-terrestrial settlements where no resupply from the Earth or other planets is possible, technologies for in situ food production, water, air, and waste recovery need to be developed. The Micro-Ecological Life Support System Alternative (MELiSSA) is such a Regenerative Life Support System (RLSS) and it builds on several bacterial bioprocesses. However, alterations in gravity, temperature, and radiation associated with the space environment can affect survival and functionality of the microorganisms. In this study, representative strains of different carbon and nitrogen metabolisms with application in the MELiSSA were selected for launch and Low Earth Orbit (LEO) exposure. An edible photoautotrophic strain (Arthrospira sp. PCC 8005), a photoheterotrophic strain (Rhodospirillum rubrum S1H), a ureolytic heterotrophic strain (Cupriavidus pinatubonensis 1245), and combinations of C. pinatubonensis 1245 and autotrophic ammonia and nitrite oxidizing strains (Nitrosomonas europaea ATCC19718, Nitrosomonas ureae Nm10, and Nitrobacter winogradskyi Nb255) were sent to the International Space Station (ISS) for 7 days. There, the samples were exposed to 2.8 mGy, a dose 140 times higher than on the Earth, and a temperature of 22°C ± 1°C. On return to the Earth, the cultures were reactivated and their growth and activity were compared with terrestrial controls stored under refrigerated (5°C ± 2°C) or room temperature (22°C ± 1°C and 21°C ± 0°C) conditions. Overall, no difference was observed between terrestrial and ISS samples. Most cultures presented lower cell viability after the test, regardless of the type of exposure, indicating a harsher effect of the storage and sample preparation than the spaceflight itself. Postmission analysis revealed the successful survival and proliferation of all cultures except for Arthrospira, which suffered from the premission depressurization test. These observations validate the possibility of launching, storing, and reactivating bacteria with essential functionalities for microbial bioprocesses in RLSS.


Assuntos
Bactérias/metabolismo , Exobiologia , Voo Espacial , Astronave , Processos Autotróficos , Estudos de Viabilidade , Viabilidade Microbiana , Nitrificação , Temperatura , Ureia/metabolismo
16.
Radiat Prot Dosimetry ; 164(4): 484-8, 2015 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-25979739

RESUMO

Aircrew members and passengers are exposed to increased rates of cosmic radiation on-board commercial jet aircraft. The annual effective doses of crew members often exceed limits for public, thus it is recommended to monitor them. In general, the doses are estimated via various computer codes and in some countries also verified by measurements. This paper describes a comparison of three cosmic rays detectors, namely of the (a) HAWK Tissue Equivalent Proportional Counter; (b) Liulin semiconductor energy deposit spectrometer and (c) TIMEPIX silicon semiconductor pixel detector, exposed to radiation fields on-board commercial Czech Airlines company jet aircraft. Measurements were performed during passenger flights from Prague to Madrid, Oslo, Tbilisi, Yekaterinburg and Almaty, and back in July and August 2011. For all flights, energy deposit spectra and absorbed doses are presented. Measured absorbed dose and dose equivalent are compared with the EPCARD code calculations. Finally, the advantages and disadvantages of all detectors are discussed.


Assuntos
Aeronaves/instrumentação , Radiação Cósmica , Exposição Ocupacional/análise , Monitoramento de Radiação/instrumentação , Absorção de Radiação , Desenho de Equipamento , Humanos , Exposição Ocupacional/normas , Exposição à Radiação , Semicondutores , Atividade Solar
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA