1.
Cureus ; 16(2): e54583, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38384867

RESUMO

Chronic lung allograft dysfunction (CLAD) continues to be the leading cause of death in the long term after lung transplantation (LTx). CLAD has the following two main subtypes: bronchiolitis obliterans syndrome (BOS) and restrictive allograft syndrome (RAS). BOS features obstructive lung dysfunction, while RAS features restrictive lung dysfunction. Overall, RAS has a worse prognosis. The pathophysiology of CLAD is not fully understood; however, pulmonary infections can trigger CLAD, including coronavirus disease 2019 (COVID-19) pneumonia. Here, we describe a case of a 55-year-old female who received LTx about seven years ago and developed RAS after COVID-19 pneumonia. RAS was ultimately diagnosed based on the clinical course and imaging findings. Steroid pulse therapy and empirical antimicrobial therapy were initiated, but respiratory failure progressed, and the patient died 139 days after COVID-19 diagnosis, and 83 days after dyspnea progression. Clinicians should be aware of unusual stair-step clinical courses and imaging features in a given setting of pulmonary infection including COVID-19 to suspect CLAD in lung transplant patients.

2.
Magn Reson Med ; 91(5): 1863-1875, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38192263

RESUMO

PURPOSE: To evaluate a vendor-agnostic multiparametric mapping scheme based on 3D quantification using an interleaved Look-Locker acquisition sequence with a T2 preparation pulse (3D-QALAS) for whole-brain T1, T2, and proton density (PD) mapping. METHODS: This prospective, multi-institutional study was conducted between September 2021 and February 2022 using five different 3T systems from four prominent MRI vendors. The accuracy of this technique was evaluated using a standardized MRI system phantom. Intra-scanner repeatability and inter-vendor reproducibility of T1, T2, and PD values were evaluated in 10 healthy volunteers (6 men; mean age ± SD, 28.0 ± 5.6 y) who underwent scan-rescan sessions on each scanner (total scans = 100). To evaluate the feasibility of 3D-QALAS, nine patients with multiple sclerosis (nine women; mean age ± SD, 48.2 ± 11.5 y) underwent imaging examination on two 3T MRI systems from different manufacturers. RESULTS: Quantitative maps obtained with 3D-QALAS showed high linearity (R2 = 0.998 and 0.998 for T1 and T2, respectively) with respect to reference measurements. The mean intra-scanner coefficients of variation for each scanner and structure ranged from 0.4% to 2.6%. The mean structure-wise test-retest repeatabilities were 1.6%, 1.1%, and 0.7% for T1, T2, and PD, respectively. Overall, high inter-vendor reproducibility was observed for all parameter maps and all structure measurements, including white matter lesions in patients with multiple sclerosis. CONCLUSION: The vendor-agnostic multiparametric mapping technique 3D-QALAS provided reproducible measurements of T1, T2, and PD for human tissues within a typical physiological range using 3T scanners from four different MRI manufacturers.


Assuntos
Encéfalo , Esclerose Múltipla , Masculino , Humanos , Feminino , Reprodutibilidade dos Testes , Estudos Prospectivos , Encéfalo/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Imagens de Fantasmas , Esclerose Múltipla/diagnóstico por imagem , Mapeamento Encefálico
3.
Magn Reson Med Sci ; 23(2): 204-213, 2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-36990741

RESUMO

PURPOSE: Burning mouth syndrome (BMS) is defined by a burning sensation or pain in the tongue or other oral sites despite the presence of normal mucosa on inspection. Both psychiatric and neuroimaging investigations have examined BMS; however, there have been no analyses using the neurite orientation dispersion and density imaging (NODDI) model, which provides detailed information of intra- and extracellular microstructures. Therefore, we performed voxel-wise analyses using both NODDI and diffusion tensor imaging (DTI) models and compared the results to better comprehend the pathology of BMS. METHODS: Fourteen patients with BMS and 11 age- and sex-matched healthy control subjects were prospectively scanned using a 3T-MRI machine using 2-shell diffusion imaging. Diffusion tensor metrics (fractional anisotropy [FA], mean diffusivity [MD], axial diffusivity [AD], and radial diffusivity [RD]) and neurite orientation and dispersion index metrics (intracellular volume fraction [ICVF], isotropic volume fraction [ISO], and orientation dispersion index [ODI]) were retrieved from diffusion MRI data. These data were analyzed using tract-based spatial statistics (TBSS) and gray matter-based spatial statistics (GBSS). RESULTS: TBSS analysis showed that patients with BMS had significantly higher FA and ICVF and lower MD and RD than the healthy control subjects (family-wise error [FWE] corrected P < 0.05). Changes in ICVF, MD, and RD were observed in widespread white matter areas. Fairly small areas with different FA were included. GBSS analysis showed that patients with BMS had significantly higher ISO and lower MD and RD than the healthy control subjects (FWE-corrected P < 0.05), mainly limited to the amygdala. CONCLUSION: The increased ICVF in the BMS group may represent myelination and/or astrocytic hypertrophy, and microstructural changes in the amygdala in GBSS analysis indicate the emotional-affective profile of BMS.


Assuntos
Síndrome da Ardência Bucal , Sintase do Amido , Substância Branca , Humanos , Imagem de Tensor de Difusão/métodos , Substância Cinzenta/diagnóstico por imagem , Encéfalo/diagnóstico por imagem , Neuritos , Síndrome da Ardência Bucal/diagnóstico por imagem , Imagem de Difusão por Ressonância Magnética , Substância Branca/diagnóstico por imagem
4.
J Magn Reson Imaging ; 59(4): 1135-1148, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-37424140

RESUMO

Resting-state functional magnetic resonance imaging (rsfMRI) has been developed as a method of investigating spontaneous neural activity. Based on its low-frequency signal synchronization, rsfMRI has made it possible to identify multiple macroscopic structures termed resting-state networks (RSNs) on a single scan of less than 10 minutes. It is easy to implement even in clinical practice, in which assigning tasks to patients can be challenging. These advantages have accelerated the adoption and growth of rsfMRI. Recently, studies on the global rsfMRI signal have attracted increasing attention. Because it primarily arises from physiological events, less attention has hitherto been paid to the global signal than to the local network (i.e., RSN) component. However, the global signal is not a mere nuisance or a subsidiary component. On the contrary, it is quantitatively the dominant component that accounts for most of the variance in the rsfMRI signal throughout the brain and provides rich information on local hemodynamics that can serve as an individual-level diagnostic biomarker. Moreover, spatiotemporal analyses of the global signal have revealed that it is closely and fundamentally associated with the organization of RSNs, thus challenging the basic assumptions made in conventional rsfMRI analyses and views on RSNs. This review introduces new concepts emerging from rsfMRI spatiotemporal analyses focusing on the global signal and discusses how they may contribute to future clinical medicine. EVIDENCE LEVEL: 5 TECHNICAL EFFICACY: Stage 1.


Assuntos
Mapeamento Encefálico , Imageamento por Ressonância Magnética , Humanos , Mapeamento Encefálico/métodos , Imageamento por Ressonância Magnética/métodos , Descanso/fisiologia , Encéfalo/diagnóstico por imagem , Encéfalo/fisiologia , Hemodinâmica
5.
Front Neurosci ; 17: 1220848, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37662100

RESUMO

Resting-state functional magnetic resonance imaging (rsfMRI) has been widely applied to investigate spontaneous neural activity, often based on its macroscopic organization that is termed resting-state networks (RSNs). Although the neurophysiological mechanisms underlying the RSN organization remain largely unknown, accumulating evidence points to a substantial contribution from the global signals to their structured synchronization. This study further explored the phenomenon by taking advantage of the inter- and intra-subject variations of the time delay and correlation coefficient of the signal timeseries in each region using the global mean signal as the reference signal. Consistent with the hypothesis based on the empirical and theoretical findings, the time lag and correlation, which have consistently been proven to represent local hemodynamic status, were shown to organize networks equivalent to RSNs. The results not only provide further evidence that the local hemodynamic status could be the direct source of the RSNs' spatial patterns but also explain how the regional variations in the hemodynamics, combined with the changes in the global events' power spectrum, lead to the observations. While the findings pose challenges to interpretations of rsfMRI studies, they further support the view that rsfMRI can offer detailed information related to global neurophysiological phenomena as well as local hemodynamics that would have great potential as biomarkers.

6.
Radiol Case Rep ; 18(5): 1929-1932, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-36970234

RESUMO

Intravascular lymphoma (IVL) is difficult to diagnose because its clinical presentation and laboratory and imaging findings are nonspecific. Herein, we report a case of IVL presenting as a lesion in the splenium of the corpus callosum. A 52-year-old man attended the emergency department with a 2-week history of progressively worsening abnormal behavior and gait disturbance. Magnetic resonance imaging on admission revealed an oval lesion in the splenium of the corpus callosum. The follow-up magnetic resonance imaging performed 2 months after disease onset revealed multiple high-signal areas in the bilateral cerebral white matter on T2-weighted images and diffusion-weighted images. The blood test results showed an elevated level of lactate dehydrogenase and serum-soluble interleukin-2 receptor. These findings were compatible with the diagnosis of IVL. IVL is often difficult to diagnose due to a wide variety of clinical presentations and imaging findings.

7.
Acta Radiol ; 64(5): 1958-1965, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-36426577

RESUMO

BACKGROUND: Brain metastases (BMs) are the most common intracranial tumors causing neurological complications associated with significant morbidity and mortality. PURPOSE: To evaluate the effect of computer-aided detection (CAD) on the performance of observers in detecting BMs on non-enhanced computed tomography (NECT). MATERIAL AND METHODS: Three less experienced and three experienced radiologists interpreted 30 NECT scans with 89 BMs in 25 cases to detect BMs with and without the assistance of CAD. The observers' sensitivity, number of false positives (FPs), positive predictive value (PPV), and reading time with and without CAD were compared using paired t-tests. The sensitivity of CAD and the observers were compared using a one-sample t-test. RESULTS: With CAD, less experienced radiologists' sensitivity significantly increased from 27.7% ± 4.6% to 32.6% ± 4.8% (P = 0.007), while the experienced radiologists' sensitivity did not show a significant difference (from 33.3% ± 3.5% to 31.9% ± 3.7%; P = 0.54). There was no significant difference between conditions with CAD and without CAD for FPs (less experienced radiologists: 23.0 ± 10.4 and 25.0 ± 9.3; P = 0.32; experienced radiologists: 18.3 ± 7.4 and 17.3 ± 6.7; P = 0.76) and PPVs (less experienced radiologists: 57.9% ± 8.3% and 50.9% ± 7.0%; P = 0.14; experienced radiologists: 61.8% ± 12.7% and 64.0% ± 12.1%; P = 0.69). There were no significant differences in reading time with and without CAD (85.0 ± 45.6 s and 73.7 ± 36.7 s; P = 0.09). The sensitivity of CAD was 47.2% (with a PPV of 8.9%), which was significantly higher than that of any radiologist (P < 0.001). CONCLUSION: CAD improved BM detection sensitivity on NECT without increasing FPs or reading time among less experienced radiologists, but this was not the case among experienced radiologists.


Assuntos
Neoplasias Encefálicas , Tomografia Computadorizada por Raios X , Humanos , Sensibilidade e Especificidade , Tomografia Computadorizada por Raios X/métodos , Radiologistas , Neoplasias Encefálicas/diagnóstico por imagem , Computadores
8.
Magn Reson Med Sci ; 22(3): 373-378, 2023 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-35387960

RESUMO

Liver acquisition with volume acceleration-flex (LAVA-Flex) acquires out-of-phase and in-phase echo images and automatically generates water-only and fat-only images from one single acquisition. The scan time of carotid MR angiography (MRA) using LAVA-Flex (LAVA MRA) is about one-fifth that of conventional time-of-flight MRA (cTOF MRA). We aimed to investigate whether LAVA MRA could provide useful information for the diagnosis of carotid plaque by utilizing the ability to acquire multiple sequences simultaneously. Comparing LAVA MRA and cTOF MRA images for carotid plaque, low-intensity plaques were more clearly identified in the in-phase images, and high-intensity plaques were more clearly identified in the water-only or out-of-phase images. None of the plaques exhibited superior visualization with the cTOF sequence. We concluded that LAVA MRA can provide more useful information on plaque evaluation using multiple sequences than cTOF MRA.


Assuntos
Artérias Carótidas , Placa Aterosclerótica , Humanos , Artérias Carótidas/diagnóstico por imagem , Angiografia por Ressonância Magnética/métodos , Imageamento Tridimensional/métodos , Fígado , Placa Aterosclerótica/diagnóstico por imagem , Água
9.
Neuroimage ; 263: 119654, 2022 11.
Artigo em Inglês | MEDLINE | ID: mdl-36180009

RESUMO

Blood oxygenation level-dependent (BOLD) contrast is sensitive to local hemodynamic changes and thus is applicable to imaging perfusion or vascular reactivity. However, knowledge about its measurement characteristics compared to reference standard perfusion imaging is limited. This study longitudinally evaluated perfusion in patients with steno-occlusive disease using resting-state functional MRI (rsfMRI) acquired before and within nine days of anterior circulation revascularization in patients with large cerebral artery steno-occlusive diseases. The reliability and sensitivity to longitudinal changes of rsfMRI temporal correlation (Rc) and time delay (TDc) relative to the cerebellar signal were examined voxel-wise in comparison with single-photon emission CT (SPECT) cerebral blood flow (CBF) using the within-subject standard deviation (Sw) and intraclass correlation coefficients (ICCs). For statistical comparisons, the standard deviation (SD) of longitudinal changes within the cerebellum, the number of voxels with significant changes in the left middle cerebral artery territory ipsilateral to surgery, and their average changes relative to the cerebellar SD were evaluated. The test-retest reliability of the fMRI metrics was also similarly evaluated using the human connectome project (HCP) healthy young adult dataset. The test-retest time interval was 31 ± 18 days. Test-retest reliability was significantly higher for SPECT (cerebellar SD: -2.59 ± 0.20) than for fMRI metrics (cerebellar SD: Rc, -2.34 ± 0.24, p = 0.04; TDc, -2.19 ± 0.21, p = 0.003). Sensitivity to postoperative changes, which was evaluated as the number of voxels, was significantly higher for fMRI TDc (8.78 ± 0.72) than for Rc (7.42 ± 1.48, p = 0.03) or SPECT CBF (6.88 ± 0.67, p < 0.001). The ratio between the average Rc, TDc, and SPECT CBF changes within the left MCA target region and cerebellar SD was also significantly higher for fMRI TDc (1.21 ± 0.79) than Rc (0.48 ± 0.94, p = 0.006) or SPECT CBF (0.23 ± 0.57, p = 0.001). The measurement variability of time delay was also larger than that of temporal correlation in HCP data within the cerebellum (t = -8.7, p < 0.001) or in the whole-brain (t = -27.4, p < 0.001) gray matter. These data suggest that fMRI time delay is more sensitive to the hemodynamic changes than SPECT CBF, although the reliability is lower. The implication for fMRI connectivity studies is that temporal correlation can be significantly decreased due to altered hemodynamics, even in cases with normal CBF.


Assuntos
Hemodinâmica , Imageamento por Ressonância Magnética , Adulto Jovem , Humanos , Imageamento por Ressonância Magnética/métodos , Reprodutibilidade dos Testes , Tomografia Computadorizada de Emissão de Fóton Único , Circulação Cerebrovascular/fisiologia
10.
J Comput Assist Tomogr ; 46(5): 786-791, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35819922

RESUMO

OBJECTIVE: This study aimed to test the usefulness of computer-aided detection (CAD) for the detection of brain metastasis (BM) on contrast-enhanced computed tomography. METHODS: The test data set included whole-brain axial contrast-enhanced computed tomography images of 25 cases with 62 BMs and 5 cases without BM. Six radiologists from 3 institutions with 2 to 4 years of experience independently reviewed the cases, both in conditions with and without CAD assistance. Sensitivity, positive predictive value, number of false positives, and reading time were compared between the conditions using paired t tests. Subanalysis was also performed for groups of lesions divided according to size. A P value <0.05 was considered statistically significant. RESULTS: With CAD, sensitivity significantly increased from 80.4% to 83.9% ( P = 0.04), whereas positive predictive value significantly decreased from 88.7% to 84.8% ( P = 0.03). Reading time with and without CAD was 112 and 107 seconds, respectively ( P = 0.38), and the number of false positives was 10.5 with CAD and 7.0 without CAD ( P = 0.053). Sensitivity significantly improved for 6- to 12-mm lesions, from 71.2% without CAD to 80.3% with CAD ( P = 0.02). The sensitivity of the CAD (95.2%) was significantly higher than that of any reader (with CAD: P = 0.01; without CAD: P = 0.005). CONCLUSIONS: Computer-aided detection significantly improved BM detection sensitivity without prolonging reading time while marginally increased the false positives.


Assuntos
Neoplasias Encefálicas , Tomografia Computadorizada por Raios X , Neoplasias Encefálicas/diagnóstico por imagem , Computadores , Humanos , Variações Dependentes do Observador , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Sensibilidade e Especificidade
11.
J Neurooncol ; 159(3): 581-590, 2022 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-35882753

RESUMO

PURPOSE: Pre-surgical diagnosis of skull base chondrosarcoma (SBC) is often challenging due to the resemblance to chordoma. The goal of this study was to develop an optimal method for predicting SBC diagnosis. METHODS: This retrospective study included patients with histologically diagnosed SBC and skull base chordoma. Their clinical and radiologic features were compared, and the predictive factors of SBC were examined. RESULTS: Forty-one patients with SBC and 41 with chordoma were included. Most SBCs exhibited hypointensity (25, 64.1%) or isointensity (12, 30.8%) on T1-weighted images, and hyperintensity (34, 87.1%) or mixed intensity (5, 12.8%) on T2-weighted images. MRI contrast enhancement was usually avid or fair (89.7%) with "arabesque"-like pattern (41.0%). The lateral/paramidline location was more common in SBC than in chordoma (85.4% vs. 9.8%; P < 0.01), while midline SBCs (14.6%) were also possible. Multivariate analysis demonstrated that higher apparent diffusion coefficient (ADC) value (unit odds ratio 1.01; 95% confidence interval 1.00-1.02; P < 0.01) was associated with an SBC diagnosis. An ADC value of ≥ 1750 × 10-6 mm2/s demonstrated a strong association with an SBC diagnosis (odds ratio 5.89 × 102; 95% confidence interval 51.0-6.80 × 103; P < 0.01) and yielded a sensitivity of 93.9%, specificity of 97.4%, positive predictive value of 96.9%, and negative predictive value of 95.0%. CONCLUSION: The ADC-based method is helpful in distinguishing SBC from chordoma and readily applicable in clinical practice. The prediction accuracy increases when other characteristics of SBC, such as non-midline location and arabesque-like enhancement, are considered together.


Assuntos
Condrossarcoma , Cordoma , Neoplasias da Base do Crânio , Condrossarcoma/diagnóstico por imagem , Condrossarcoma/patologia , Condrossarcoma/cirurgia , Cordoma/diagnóstico por imagem , Cordoma/patologia , Cordoma/cirurgia , Humanos , Imageamento por Ressonância Magnética/métodos , Estudos Retrospectivos , Base do Crânio , Neoplasias da Base do Crânio/diagnóstico por imagem , Neoplasias da Base do Crânio/patologia
12.
Radiol Case Rep ; 17(7): 2404-2407, 2022 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-35570877

RESUMO

Post-traumatic facial nerve paralysis is a common disease, but intracranial facial nerve injury after blunt injury has rarely been reported. We report a case of facial nerve avulsion at the cerebellopontine angle. A 23-year-old female with incomplete right-sided facial nerve palsy and facial spasms presented to our hospital. She had a history of traumatic injury, having fallen off a table and hit her head at the age of 2 years. After the accident, she developed complete right-sided facial nerve palsy and underwent conservative treatment with steroids. A magnetic resonance imaging examination performed 21 years later showed avulsion of the facial nerve at the cerebellopontine angle. Magnetic resonance imaging targeting the facial nerves might provide additional information to computed tomography in cases with poor recovery with conservative treatment.

13.
Neuroimage ; 255: 119176, 2022 07 15.
Artigo em Inglês | MEDLINE | ID: mdl-35390461

RESUMO

PURPOSE: To develop a rigid real-time prospective motion-corrected multiparametric mapping technique and to test the performance of quantitative estimates. METHODS: Motion tracking and correction were performed by integrating single-shot spiral navigators into a multiparametric imaging technique, three-dimensional quantification using an interleaved Look-Locker acquisition sequence with a T2 preparation pulse (3D-QALAS). The spiral navigator was optimized, and quantitative measurements were validated using a standard system phantom. The effect of motion correction on whole-brain T1 and T2 mapping under different types of head motion during the scan was evaluated in 10 healthy volunteers. Finally, six patients with Parkinson's disease, which is known to be associated with a high prevalence of motion artifacts, were scanned to evaluate the effectiveness of our method in the real world. RESULTS: The phantom study demonstrated that the proposed motion correction method did not introduce quantitative bias. Improved parametric map quality and repeatability were shown in volunteer experiments with both in-plane and through-plane motions, comparable to the no-motion ground truth. In real-life validation in patients, the approach showed improved parametric map quality compared to images obtained without motion correction. CONCLUSIONS: Real-time prospective motion-corrected multiparametric relaxometry based on 3D-QALAS provided robust and repeatable whole-brain multiparametric mapping.


Assuntos
Encéfalo , Imageamento por Ressonância Magnética , Artefatos , Encéfalo/diagnóstico por imagem , Humanos , Imageamento Tridimensional , Imageamento por Ressonância Magnética/métodos , Movimento (Física) , Imagens de Fantasmas , Estudos Prospectivos
14.
J Magn Reson Imaging ; 56(3): 929-941, 2022 09.
Artigo em Inglês | MEDLINE | ID: mdl-35188699

RESUMO

BACKGROUND: Nonenhanced MR angiography (MRA) studies are often used to manage acute and chronic large cervical artery disease, but lengthy scan times limit their clinical usefulness. PURPOSE: To develop an accelerated cervical MRA and test its diagnostic performance. STUDY TYPE: Prospective. POPULATION: Patients with cervical artery disease (n = 32, 17 males). FIELD STRENGTH/SEQUENCE: 3.0 T; accelerated two-point Dixon three-dimensional Cartesian spoiled gradient-echo (FLEXA) and conventional time-of-flight MRA (cMRA) sequences. ASSESSMENT: All patients underwent FLEXA (1'28″) and cMRA (6'47″) acquisitions. Quantitative evaluation (artery-to-background signal ratio and a blur metric) and qualitative evaluation using diagnostic performance measured by the sensitivity, specificity, and positive/negative predictive values (PPV/NPV), and vessel and plaque visualization scores from three board-certified radiologists' (with 10, 11, and 12 years of experience) independent readings using maximum intensity projection (MIP) for luminal diseases and axial images for plaque. The reference standards were contrast-enhanced angiography and fat-saturated T1-weighted images, respectively. STATISTICAL TESTS: All measures were compared between FLEXA and cMRA using the paired t, Wilcoxon signed-rank, McNemar's, or chi-squared test, as appropriate. Interreader agreement was assessed using Cohen's κ. P < 0.05 was considered statistically significant. RESULTS: The artery-to-background signal ratio was significantly higher for FLEXA (FLEXA: 7.20 ± 1.63 [fat]; 4.26 ± 0.52 [muscle]; cMRA: 2.57 ± 0.49 [fat]), while image blurring was significantly less (FLEXA: 0.24 ± 0.016; cMRA: 0.30 ± 0.029). In luminal disease detection, sensitivity (FLEXA: 0.97/0.91/0.91; cMRA:0.71/0.69/0.63), specificity (FLEXA: 0.98/0.93/0.98; cMRA:0.93/0.85/0.92), PPV (FLEXA: 0.92/0.86/0.86; cMRA: 0.64/0.5/0.58), and NPV (FLEXA: 0.99/0.98/0.98; cMRA: 0.92/0.91/0.9) were significantly higher for FLEXA. interreader agreement was substantial to almost perfect for FLEXA (κ = 0.82/0.86/0.78) and moderate to substantial for cMRA (κ = 0.67/0.56/0.57). MIP visualization scores were significantly higher for FLEXA, with substantial to almost perfect interreader agreement (FLEXA: κ = 0.83/0.86/0.82; cMRA: κ = 0.89/0.79/0.79). In plaque detection, sensitivity (FLEXA: 0.9/0.9/0.7; cMRA: 0.3/0.6/0.2) and specificity (FLEXA: 1/0.87/1; cMRA: 0.93/0.63/0.97) were significantly higher for FLEXA in two of three readers. The interreader plaque detection agreement was fair to substantial (FLEXA: κ = 0.63/0.69/0.48; cMRA: κ = 0.21/0.45/0.20). Side-by-side plaque and vessel wall visualization was superior for FLEXA in all readers, with moderate to substantial interreader agreement (plaque: κ = 0.73/0.73/0.77; vessel wall: κ = 0.57/0.40/0.39). DATA CONCLUSION: FLEXA enhanced visualization of the cervical arterial system and improved diagnostic performance for luminal abnormalities and plaques in patients with cervical artery diseases. LEVEL OF EVIDENCE: 1 TECHNICAL EFFICACY STAGE: 2.


Assuntos
Artérias , Angiografia por Ressonância Magnética , Meios de Contraste , Humanos , Angiografia por Ressonância Magnética/métodos , Masculino , Valor Preditivo dos Testes , Estudos Prospectivos
15.
Neuroradiology ; 64(8): 1511-1518, 2022 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-35064786

RESUMO

PURPOSE: This study aims to develop a 2.5-dimensional (2.5D) deep-learning, object detection model for the automated detection of brain metastases, into which three consecutive slices were fed as the input for the prediction in the central slice, and to compare its performance with that of an ordinary 2-dimensional (2D) model. METHODS: We analyzed 696 brain metastases on 127 contrast-enhanced computed tomography (CT) scans from 127 patients with brain metastases. The scans were randomly divided into training (n = 79), validation (n = 18), and test (n = 30) datasets. Single-shot detector (SSD) models with a feature fusion module were constructed, trained, and compared using the lesion-based sensitivity, positive predictive value (PPV), and the number of false positives per patient at a confidence threshold of 50%. RESULTS: The 2.5D SSD model had a significantly higher PPV (t test, p < 0.001) and a significantly smaller number of false positives (t test, p < 0.001). The sensitivities of the 2D and 2.5D models were 88.1% (95% confidence interval [CI], 86.6-89.6%) and 88.7% (95% CI, 87.3-90.1%), respectively. The corresponding PPVs were 39.0% (95% CI, 36.5-41.4%) and 58.9% (95% CI, 55.2-62.7%), respectively. The numbers of false positives per patient were 11.9 (95% CI, 10.7-13.2) and 4.9 (95% CI, 4.2-5.7), respectively. CONCLUSION: Our results indicate that 2.5D deep-learning, object detection models, which use information about the continuity between adjacent slices, may reduce false positives and improve the performance of automated detection of brain metastases compared with ordinary 2D models.


Assuntos
Neoplasias Encefálicas , Aprendizado Profundo , Neoplasias Encefálicas/diagnóstico por imagem , Neoplasias Encefálicas/secundário , Humanos , Tomografia Computadorizada por Raios X/métodos
16.
J Infect Chemother ; 28(2): 279-282, 2022 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-34580008

RESUMO

Toxoplasma gondii can develop toxoplasmic encephalitis (TE) in immunodeficient conditions such as AIDS and after organ transplantation. While some cases of TE with malignant lymphoma were reported, these cases occurred immediately after chemotherapy or when their diseases were active. Here we report the first Case of TE that occurred in patient who was in partial remission (PR) of lymphoplasmacytic lymphoma (LPL) for two years. A 76-year-old man was referred to our institute because of disturbance of consciousness, right arm weakness and paresthesia. A computed tomography (CT) scan detected multiple nodules in his brain. Magnetic resonance imaging (MRI) of the head detected multiple gadolinium-enhancing parenchymal lesions with hyperintense signals on T2-and diffusion-weighted images, located in both cerebral and cerebellar hemispheres. Blood test and cerebrospinal fluid (CSF) findings were unremarkable. His rapidly deteriorating consciousness precluded a chance of brain biopsy. Considering the limited efficacy of antimicrobials and the imaging findings that could be compatible with the diagnosis of malignant lymphoma, we suspected central nerve system (CNS) recurrence of LPL. Although chemotherapy was initiated, he died of respiratory failure just after chemotherapy. A pathological autopsy showed his cause of death was TE. To our knowledge, this is the first case of TE in long-term PR of malignant lymphoma. TE should be suspected when patients with malignant lymphoma present unexplained neurologic symptoms regardless of their treatment efficacy of lymphoma. (226/250 words).


Assuntos
Linfoma , Toxoplasma , Toxoplasmose Cerebral , Encéfalo/diagnóstico por imagem , Pré-Escolar , Humanos , Imageamento por Ressonância Magnética , Masculino , Toxoplasmose Cerebral/diagnóstico , Toxoplasmose Cerebral/tratamento farmacológico
17.
J Magn Reson Imaging ; 55(4): 1151-1160, 2022 04.
Artigo em Inglês | MEDLINE | ID: mdl-34555231

RESUMO

BACKGROUND: Scan acceleration such as parallel imaging reduces scan time, but shorter scan time may reduce the signal-to-noise ratio and affect image quality. The reproducibility of longitudinal changes in the brain structure between non-accelerated and accelerated imaging by surface-based analysis is unclear. PURPOSE: To determine the reproducibility of longitudinal changes in cortical thickness, measured by surface-based morphometry, between non-accelerated and accelerated structural T1 -weighted imaging in the healthy elderly and those with mild cognitive impairment (MCI) and Alzheimer's disease (AD). STUDY TYPE: Retrospective. SUBJECTS: Fifty healthy elderly subjects (age = 73 ± 5 years, 29 females, 21 males), 54 MCI patients (age = 71 ± 7 years, 23 females, 31 males), and 8 AD patients (age = 78 ± 6 years, 6 females, 2 males). FIELD STRENGTH/SEQUENCE: 3 T, magnetization-prepared rapid gradient-echo. ASSESSMENT: Longitudinal changes in cortical thickness estimated by the longitudinal stream in FreeSurfer from 2-year interval data, and visual assessment of image quality by three radiologists. STATISTICAL TESTS: Intraclass correlation coefficient (ICC) and Kruskal-Wallis test. A P value <0.05 was considered significant. RESULTS: Healthy elderly subjects, MCI patients, and AD patients showed different patterns in the ICC maps. For the smoothing of 20 mm full width at half maximum, the mean ICC was 0.45 overall (healthy elderly, 0.33; MCI patients, 0.49; AD patients, 0.31). The within-subject SDs of the symmetrized percent changes were similar between healthy elderly subjects (mean, 1.3%/year) and MCI patients (mean, 1.3%/year) but larger in AD patients (mean, 1.7%/year). Image quality did not significantly differ per group (P = 0.18). DATA CONCLUSION: The results of this study indicate the reproducibility of longitudinal changes in cortical thickness measured by surface-based morphometry between non-accelerated and accelerated imaging, and that the reproducibility varies by disease and region. LEVEL OF EVIDENCE: 3 TECHNICAL EFFICACY: Stage 1.


Assuntos
Doença de Alzheimer , Disfunção Cognitiva , Idoso , Idoso de 80 Anos ou mais , Doença de Alzheimer/diagnóstico por imagem , Encéfalo , Disfunção Cognitiva/diagnóstico por imagem , Feminino , Humanos , Imageamento por Ressonância Magnética/métodos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Estudos Retrospectivos
18.
J Neuroimaging ; 32(1): 111-119, 2022 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-34388855

RESUMO

BACKGROUND AND PURPOSE: To examine whether feature-fusion (FF) method improves single-shot detector's (SSD's) detection of small brain metastases on contrast-enhanced (CE) T1-weighted MRI. METHODS: The study included 234 MRI scans from 234 patients (64.3 years±12.0; 126 men). The ground-truth annotation was performed semiautomatically. SSDs with and without an FF module were developed and trained using 178 scans. The detection performance was evaluated at the SSDs' 50% confidence threshold using sensitivity, positive-predictive value (PPV), and the false-positive (FP) per scan with the remaining 56 scans. RESULTS: FF-SSD achieved an overall sensitivity of 86.0% (95% confidence interval [CI]: [83.0%, 85.6%]; 196/228) and 46.8% PPV (95% CI: [42.0%, 46.3%]; 196/434), with 4.3 FP (95% CI: [4.3, 4.9]). Lesions smaller than 3 mm had 45.8% sensitivity (95% CI: [36.1%, 45.5%]; 22/48) with 2.0 FP (95% CI: [1.9, 2.1]). Lesions measuring 3-6 mm had 92.3% sensitivity (95% CI: [86.5%, 92.0%]; 48/52) with 1.8 FP (95% CI: [1.7, 2.2]). Lesions larger than 6 mm had 98.4% sensitivity (95% CI: [97.8%, 99.4%]; 126/128) 0.5 FP (95% CI: [0.5, 0.8]) per scan. FF-SSD had a significantly higher sensitivity for lesions < 3 mm (p = 0.008, t = 3.53) than the baseline SSD, while the overall PPV was similar (p = 0.06, t = -2.16). A similar trend was observed even when the detector's confidence threshold was varied as low as 0.2, for which the FF-SSD's sensitivity was 91.2% and the FP was 9.5. CONCLUSIONS: The FF-SSD algorithm identified brain metastases on CE T1-weighted MRI with high accuracy.


Assuntos
Neoplasias Encefálicas , Aprendizado Profundo , Algoritmos , Neoplasias Encefálicas/diagnóstico por imagem , Humanos , Imageamento por Ressonância Magnética/métodos , Masculino , Sensibilidade e Especificidade
19.
J Magn Reson Imaging ; 55(1): 178-187, 2022 01.
Artigo em Inglês | MEDLINE | ID: mdl-34263988

RESUMO

BACKGROUND: Although perfusion imaging plays a key role in the management of steno-occlusive diseases, the clinical usefulness of arterial spin labeling (ASL) is limited by technical issues. PURPOSE: To examine the effect of arterial transit time (ATT) prolongation on cerebral blood flow (CBF) measurement accuracy and identify the best CBF measurement protocol for steno-occlusive diseases. STUDY TYPE: Prospective. POPULATION: Moyamoya (n = 10) and atherosclerotic diseases (n = 8). FIELD STRENGTH/SEQUENCE: A 3.0T/3DT1 -weighted and ASL. ASSESSMENT: Hadamard-encoded multidelay ASL scans with/without vessel suppression (VS) and single-delay ASL scans with long-label duration (LD) and long postlabeling delay (PLD), referred to as long-label long-delay (LLLD), were acquired. CBF measurement accuracy and its ATT dependency, measured as the correlation between the relative CBF measurement difference (ASL-single-photon emission computed tomography [SPECT]) and ATT, were compared among 1) Combo (incorporating multidelay and LLLD data based on ATT), 2) standard (LD/PLD = 1333/2333 msec), and 3) LLLD (LD/PLD = 4000/4000 msec) protocols, using whole-brain voxel-wise correlation with reference standard SPECT CBF. The effect of VS on CBF measurement accuracy was also assessed. STATISTICAL TESTS: Pearson's correlation coefficient, repeated-measures analysis of variance, t-test. P< 0.05 was considered significant. RESULTS: Pearson's correlation coefficients between ASL and SPECT CBF measurements were as follows: Combo = 0.55 ± 0.09; standard = 0.52 ± 0.12; LLLD = 0.41 ± 0.10. CBF measurement was least accurate in LLLD and most accurate in Combo. VS significantly improved overall CBF measurement accuracy in the standard protocol and in moyamoya patients for the Combo. ATT dependency analysis revealed that, compared with Combo, the standard and LLLD protocols showed significantly lower and negative and significantly higher and positive correlations, respectively (standard = -0.12 ± 0.04, Combo = -0.04 ± 0.03, LLLD = 0.17 ± 0.03). DATA CONCLUSION: By using ATT-corrected CBF derived from LD/PLD = 1333/2333 msec as a base and by compensating underestimation in delayed regions using multidelay scans, the ATT-based Combo strategy improves CBF measurement accuracy compared with single-delay protocols in severe steno-occlusive diseases. EVIDENCE LEVEL: 1 TECHNICAL EFFICACY: Stage 2.


Assuntos
Circulação Cerebrovascular , Humanos , Estudos Prospectivos , Marcadores de Spin
20.
J Magn Reson Imaging ; 55(6): 1723-1732, 2022 06.
Artigo em Inglês | MEDLINE | ID: mdl-34780101

RESUMO

BACKGROUND: Noninvasive cerebral blood flow (CBF) monitoring using arterial spin labeling (ASL) magnetic resonance imaging is useful for managing large cerebral artery steno-occlusive diseases. However, knowledge about its measurement characteristics in comparison with reference standard perfusion imaging is limited. PURPOSE: To evaluate perfusion in a longitudinal manner in patients with steno-occlusive disease using ASL and compare with single-photon emission computed tomography (SPECT). STUDY TYPE: Prospective. POPULATION: Moyamoya (n = 10, eight females) and atherosclerotic diseases (n = 2, two males). FIELD STRENGTH/SEQUENCE: 3.0 T; gradient-echo three-dimensional T1 -weighted and spin-echo ASL. ASSESSMENT: Multi-delay ASL and [123 I]-iodoamphetamine SPECT CBF measurements were performed both before and within 9 days of anterior-circulation revascularization. Reliability and sensitivity to whole-brain voxel-wise CBF changes (ΔCBF) and their postlabeling delay (PLD) dependency with varied PLDs (in milliseconds) of 1000, 2333, and 3666 were examined. STATISTICAL TESTS: Reliability and sensitivity to ΔCBF were examined using within-subject standard deviation (Sw) and intraclass correlation coefficients (ICCs). For statistical comparisons, standard deviation of longitudinal ΔCBF within the hemisphere contralateral to surgery, and the ratio between it and average ΔCBF within the ipsilateral regions of interest were subjected to paired t tests, respectively. P < 0.05 was considered statistically significant. RESULTS: ASL test-retest time interval was 31 ± 18 days. Test-retest reliability was significantly lower for SPECT (0.16 ± 0.02) than ASL (0.13 ± 0.04). Sensitivity to postoperative changes was significantly higher for ASL (2.71 ± 2.79) than SPECT (0.27 ± 0.62). Test-retest reliability was significantly higher for a PLD of 2333 (0.13 ± 0.04) than 3666 (0.19 ± 0.05), and sensitivity to ΔCBF was significantly higher for PLDs of 1000 (2.53 ± 2.50) and 2333 than 3666 (0.79 ± 1.88). ICC maps also showed higher reliability for ASL than SPECT. DATA CONCLUSION: Higher test-retest reliability led to better ASL sensitivity than SPECT for postoperative ΔCBF. ASL test-retest reliability and sensitivity to ΔCBF were higher with a PLD of 2333. LEVEL OF EVIDENCE: 1 TECHNICAL EFFICACY: Stage 2.


Assuntos
Circulação Cerebrovascular , Feminino , Humanos , Masculino , Circulação Cerebrovascular/fisiologia , Imageamento por Ressonância Magnética/métodos , Estudos Prospectivos , Reprodutibilidade dos Testes , Marcadores de Spin , Tomografia Computadorizada de Emissão de Fóton Único/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA