1.
Opt Lett ; 45(20): 5879, 2020 Oct 15.
Artigo em Inglês | MEDLINE | ID: mdl-33057308

RESUMO

The referenced article [Opt. Lett.43, 4615 (2018)OPLEDP0146-959210.1364/OL.43.004615] has been retracted by the authors.

2.
Opt Lett ; 43(19): 4615-4618, 2018 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-30272705

RESUMO

Miniaturized magnetic field sensors are increasingly used in various applications, such as geophysical exploration for minerals and oil, volcanology, earthquake studies, and biomedical imaging. Existing magnetometers lack either the spatial or the temporal resolution or are restricted to costly shielded labs and cannot operate in an unshielded environment. Increasing spatio-temporal resolution would allow for real-time measurements of magnetic fluctuations with high resolution. Here we report on a new nanocomposite-based system for miniaturized magnetic field sensing. The sensor is based on Dy3+-doped magnetite and cobalt ferrite nanoparticles dispersed in a polymer matrix. Operation is feasible at room temperature and in an unshielded environment. A compact fiber-optic interferometer is used as the detection mechanism with 20 fT/√Hz sensitivity. We investigated the magnetic field response of the sensor and demonstrated the measurement of the human heartbeat as a potential application.

3.
Sci Rep ; 7(1): 13990, 2017 10 25.
Artigo em Inglês | MEDLINE | ID: mdl-29070904

RESUMO

Using a phoropter to measure the refractive error is one of the most commonly used methods by ophthalmologists and optometrists. Here, we demonstrate design and fabrication of a portable automatic phoropter with no need for patient's feedback. The system is based on three tunable-focus fluidic lenses and thin-film holographic optical elements to perform automatic refractive error measurement and provide a diagnostic prescription without supervision. Three separate lenses are deployed to correct the defocus and astigmatism. The refractive error is measured using a Shack-Hartmann wavefront sensor that calculates the Zernike values of an infrared wavefront emerging from the eye. Holographic optical elements steer the emerging wavefront into the wavefront sensor, while simultaneously providing an unobstructed view for the subject. The power of each lens is controlled by pumping a liquid in and out of the lens chamber using servo motor actuated diaphragm pumps. Spherical and cylindrical correction range of -10 to +10 diopters with 0.1 diopter increments is achieved in less than 15 seconds using wavefront sensor feedback to the pumps. This system can be used in rapid screening of large patient populations especially in the developing countries that lack sufficient facilities and specialist doctors.


Assuntos
Cristalino , Refração Ocular/fisiologia , Erros de Refração/diagnóstico , Refratometria/economia , Refratometria/instrumentação , Testes Visuais/instrumentação , Acuidade Visual/fisiologia , Países em Desenvolvimento , Desenho de Equipamento , Humanos , Erros de Refração/terapia
4.
Opt Express ; 25(19): 23399-23407, 2017 Sep 18.
Artigo em Inglês | MEDLINE | ID: mdl-29041641

RESUMO

We present the design, construction, and characterization of a multiphoton microscope that uses reflective elements for beam shaping and steering. This compact all reflective design removes the adverse effects of dispersion on laser pulse broadening as well as chromatic aberration in the focusing of broadband and multicolored laser sources. The design of this system is discussed in detail, including aberrations analysis via ray-tracing simulation and opto-mechanical design. The resolution of this mirror based all-reflective microscope is characterized using fluorescent microbeads. The performance of the system at multiple wavelengths is investigated along with some potential multiphoton imaging and writing applications.

5.
Nat Commun ; 8: 15714, 2017 06 05.
Artigo em Inglês | MEDLINE | ID: mdl-28580960

RESUMO

Grain boundaries have a major effect on the physical properties of two-dimensional layered materials. Therefore, it is important to develop simple, fast and sensitive characterization methods to visualize grain boundaries. Conventional Raman and photoluminescence methods have been used for detecting grain boundaries; however, these techniques are better suited for detection of grain boundaries with a large crystal axis rotation between neighbouring grains. Here we show rapid visualization of grain boundaries in chemical vapour deposited monolayer MoS2 samples with multiphoton microscopy. In contrast to Raman and photoluminescence imaging, third-harmonic generation microscopy provides excellent sensitivity and high speed for grain boundary visualization regardless of the degree of crystal axis rotation. We find that the contrast associated with grain boundaries in the third-harmonic imaging is considerably enhanced by the solvents commonly used in the transfer process of two-dimensional materials. Our results demonstrate that multiphoton imaging can be used for fast and sensitive characterization of two-dimensional materials.

6.
J Phys Chem Lett ; 8(7): 1343-1350, 2017 Apr 06.
Artigo em Inglês | MEDLINE | ID: mdl-28266862

RESUMO

Black phosphorus (BP) is a layered semiconductor that recently has been the subject of intense research due to its novel electrical and optical properties, which compare favorably to those of graphene and the transition metal dichalcogenides. In particular, BP has a direct bandgap that is thickness-dependent and highly anisotropic, making BP an interesting material for nanoscale optical and optoelectronic applications. Here, we present a study of the anisotropic third-harmonic generation (THG) in exfoliated BP using a fast scanning multiphoton characterization method. We find that the anisotropic THG arises directly from the crystal structure of BP. We calculate the effective third-order susceptibility of BP to be ∼1.64 × 10-19 m2 V-2. Further, we demonstrate that multiphoton microscopy can be used for rapid, large-area characterization indexing of the crystallographic orientations of many exfoliated BP flakes from one set of multiphoton images. This method is therefore beneficial for samples of areas ∼1 cm2 in future investigations of the properties and growth of BP.

7.
Biomed Opt Express ; 7(7): 2849-60, 2016 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-27446711

RESUMO

The use of receptor-targeted lipid microbubbles imaged by ultrasound is an innovative method of detecting and localizing disease. However, since ultrasound requires a medium between the transducer and the object being imaged, it is impractical to apply to an exposed surface in a surgical setting where sterile fields need be maintained and ultrasound gel may cause the bubbles to collapse. Multiphoton microscopy (MPM) is an emerging tool for accurate, label-free imaging of tissues and cells with high resolution and contrast. We have recently determined a novel application of MPM to be used for detecting targeted microbubble adherence to the upregulated plectin-receptor on pancreatic tumor cells. Specifically, the third-harmonic generation response can be used to detect bound microbubbles to various cell types presenting MPM as an alternative and useful imaging method. This is an interesting technique that can potentially be translated as a diagnostic tool for the early detection of cancer and inflammatory disorders.

8.
Opt Express ; 24(3): 2965-70, 2016 Feb 08.
Artigo em Inglês | MEDLINE | ID: mdl-26906863

RESUMO

By using scanning multiphoton microscopy we compare the nonlinear optical properties of the directly deposited and transferred to the dielectric substrate graphene. The direct deposition of graphene on oxidized silicon wafer was done by utilizing sacrificial copper catalyst film. We demonstrate that the directly deposited graphene and bi-layered transferred graphene produce comparable third harmonic signals and have almost the same damage thresholds. Therefore, we believe directly deposited graphene is suitable for the use of e.g. nanofabricated optical setups.

9.
Biomed Opt Express ; 7(1): 148-57, 2016 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-26819824

RESUMO

Barrett's esophagus (BE) is a metaplastic disorder where dysplastic and early cancerous changes are invisible to the naked eye and where the practice of blind biopsy is hampered by large sampling errors. Multi-photon microscopy (MPM) has emerged as an alternative solution for fast and label-free diagnostic capability for identifying the histological features with sub-micron accuracy. We developed a compact, inexpensive MPM system by using a handheld mode-locked fiber laser operating at 1560nm to study mucosal biopsies of BE. The combination of back-scattered THG, back-reflected forward THG and SHG signals generate images of cell nuclei and collagen, leading to label-free diagnosis in Barrett's.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA