RESUMO
Leaflet escape in contemporary mechanical valves is an extremely rare and potentially lethal condition. We report the case of a 77-year-old man who presented with embolization of a leaflet from an On-X mitral valve (CryoLife, Kennesaw, GA) with Conform-X Sewing Ring prosthesis (CryoLife) after exercise. The patient recovered completely 6 months after surgery, and he is currently asymptomatic.
Assuntos
Próteses Valvulares Cardíacas , Valva Mitral/cirurgia , Falha de Prótese , Idoso , Implante de Prótese de Valva Cardíaca , Humanos , Masculino , Desenho de Prótese , Indução de Remissão , RetratamentoRESUMO
Modified techniques for orthotopic heart transplantation are mandatory when complex congenital anomalies are associated in adult patients. An unusual case of a heterotaxy syndrome and dilated cardiomyopathy following mitral ring annuloplasty is presented in a 62-year-old male. Orthotopic cardiac transplantation was performed by using a modified operative strategy: selective peripheral and central venous cannulation according to the thoraco-abdominal venous challenges, biatrial technique, and preservation of venous drainage via the native coronary sinus. We discuss the anatomical features of heterotaxy in adult patients and surgical approaches when heart transplantation is needed.