Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
2.
Materials (Basel) ; 16(16)2023 Aug 21.
Artigo em Inglês | MEDLINE | ID: mdl-37630008

RESUMO

Titanium (Ti) and Ti-based alloys are commonly used in dental implants, and surface modifications of dental implants are important for achieving osseointegration (i.e., direct connection between the implant surface and bone). This study investigated the effect of an eco-friendly etching solution-a hydrogen peroxide-sodium bicarbonate mixture-on the surface properties and contact angles of osteoblast adhesion and proliferation on Ti surfaces. Disk-shaped Ti specimens were prepared using different surface treatments (machining, sandblasting, and sandblasting/acid-etching), and they were immersed in the etching solution and ultrasonically cleaned. Surface characterization was performed using scanning electron microscopy, digital microscopy, contact angle analysis, and X-ray photoelectron spectroscopy. MG-63 osteoblasts were cultured on the specimens, and their adhesion to the specimen surface and proliferation were examined using staining and the MTT assay, respectively. Additional etching with the etching solution caused the formation of nano/micro hierarchical structures, increased surface roughness, and enhanced hydrophilicity. Osteoblast adhesion and proliferation were found to improve on the modified surfaces. The eco-friendly etching method has the potential to enhance the biological properties of Ti implant surfaces and thereby improve dental implant performance.

3.
J Periodontal Implant Sci ; 53(4): 306-317, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-37524378

RESUMO

PURPOSE: Biphasic calcium phosphate (BCP), a widely used biomaterial for bone regeneration, contains synthetic hydroxyapatite (HA) and ß-tricalcium phosphate (ß-TCP), the ratio of which can be adjusted to modulate the rate of degradation. The aim of this study was to evaluate the clinical and radiographic benefits of reconstructing peri-implant bone defects with a newly developed BCP consisting of 40% ß-TCP and 60% HA compared to demineralized bovine bone mineral (DBBM). METHODS: This prospective, multicenter, parallel, single-blind randomized controlled trial was conducted at the periodontology departments of 3 different dental hospitals. Changes in clinical (defect width and height) and radiographic (augmented horizontal bone thickness) parameters were measured between implant surgery with guided bone regeneration (GBR) and re-entry surgery. Postoperative discomfort (severity and duration of pain and swelling) and early soft-tissue wound healing (dehiscence and inflammation) were also assessed. Data were compared between the BCP (test) and DBBM (control) groups using the independent t-test and the χ² test. RESULTS: Of the 53 cases included, 27 were in the test group and 26 were in the control group. After a healing period of 18 weeks, the full and mean resolution of buccal dehiscence defects were 59.3% (n=16) and 71.3% in the test group and 42.3% (n=11) and 57.9% in the control group, respectively. There were no significant differences between the groups in terms of the change in mean horizontal bone augmentation (test group: -0.50±0.66 mm vs. control groups: -0.66±0.83 mm, P=0.133), postoperative discomfort, or early wound healing. No adverse or fatal complications occurred in either group. CONCLUSION: The GBR procedure with the newly developed BCP showed favorable clinical, radiographic, postoperative discomfort-related, and early wound healing outcomes for peri-implant dehiscence defects that were similar to those for DBBM. TRIAL REGISTRATION: Clinical Research Information Service Identifier: KCT0006428.

4.
Nanomaterials (Basel) ; 13(2)2023 Jan 16.
Artigo em Inglês | MEDLINE | ID: mdl-36678110

RESUMO

Background: Implant surface topography is a key element in achieving osseointegration. Nanostructured surfaces have shown promising results in accelerating and improving bone healing around dental implants. The main objective of the present clinical and histological study is to compare, at 4 and 6 weeks, (w) bone-to-implant contact in implants having either machined surface (MAC), sandblasted, large grit, acid-etched implant surface (SLA) medium roughness surface or a nanostructured calcium-incorporated surface (XPEED®). Methods: 35 mini-implants of 3.5 × 8.5 mm with three different surface treatments (XPEED® (n = 16)­SLA (n = 13)­MAC (n = 6), were placed in the posterior maxilla of 11 patients (6 females and 5 males) then, retrieved at either 4 or 6w in a randomized split-mouth study design. Results: The BIC rates measured at 4w and 6w respectively, were: 16.8% (±5.0) and 29.0% (±3.1) for MAC surface; 18.5% (±2.3) and 33.7% (±3.3) for SLA surface; 22.4% (±1.3) and 38.6% (±3.2) for XPEED® surface. In all types of investigated surfaces, the time factor appeared to significantly increase the bone to implant contact (BIC) rate (p < 0.05). XPEED® surface showed significantly higher BIC values when compared to both SLA and MAC values at 4w (p < 0.05). Also, at 6w, both roughened surfaces (SLA and XPEED®) showed significantly higher values (p < 0.05) than turned surface (MAC). Conclusions: Nanostructured Calcium titanate coating is able to enhance bone deposition around implants at early healing stages.

5.
J Biomater Appl ; 37(7): 1228-1242, 2023 02.
Artigo em Inglês | MEDLINE | ID: mdl-36205350

RESUMO

This study evaluated surface characteristics and biocompatibility of surface-modified thin titanium (Ti) foils as a regenerative barrier membrane for future application in guided bone regeneration (GBR) surgery to augment atrophic alveolar bone. Anodic oxidation and post-heat treatment were performed to prepare various Ti foil samples. Then, the in vitro soft and hard tissue compatibility of the samples was evaluated by examining the cell responses using primary human gingival fibroblasts (HGFs) and MG63 human osteoblast-like cells. Investigated Ti foil samples showed marked differences in physicochemical surface properties. Additional 400°C heat treatment applied to the anodized Ti surface led to formation of an anatase titanium dioxide structure and well-organized nanoscale protrusions, and significantly increased surface wettability. Anodization and heat treatment enhanced the growth of HGFs and MG63 cells in Ti foil samples. Additional heat treatment for 10 and 30 min further significantly improved the response of HGFs including spreading and proliferation, and upregulated the mRNA expression of cell adhesion- and maturation-related genes as well as the osteoblast differentiation of MG63 cells. Ti foil sample with thin oxide coating obtained by a 30 min heat treatment exhibited poor clinical plasticity as a regenerative barrier membrane, which showed complete coating failure in the bending test. Our results indicate that anatase Ti oxide coating of a specific film thickness with nanoscale surface protrusion morphology and hydrophilic characteristics obtained by anodization and post-heat treatment would be an effective approach as a biocompatible Ti regenerative membrane for inducing better regeneration of both gingival tissue and bone.


Assuntos
Regeneração Óssea , Titânio , Humanos , Titânio/química , Propriedades de Superfície , Adesão Celular , Óxidos/metabolismo , Osteoblastos , Proliferação de Células
6.
Bioengineering (Basel) ; 9(10)2022 Sep 20.
Artigo em Inglês | MEDLINE | ID: mdl-36290451

RESUMO

(1) Background: The stability of implants plays a significant role in the success of osseointegration. The stability of the connection between the fixture and the abutment is one of the critical factors affecting osseointegration. When restoring multiple, non-parallel, and splinted implants, achieving a passive fit can be complicated and challenging. A new EZ post non-engaging abutment system of the BlueDiamond® (BD) implant allows a wide connection angle while achieving a passive prosthesis fit. This study aimed to confirm the new abutment system's clinical applicability by evaluating its biomechanical characteristics using finite element analysis (FEA). (2) Methods: The implant-supported fixed three-unit dental prostheses model was reproduced for two groups of AnyOne® (AO) and BD implants using FEA. The loading conditions were a preload of 200 N in the first step and loads of 100 N (axial), 100 N (15°), or 30 N (45°) in the second step. (3) Results: The peak Von Mises stress (PVMS) value of the fixture in the BD group was more than twice that in the AO group. In contrast, the PVMS values of the abutment and abutment screws were lower in the BD group than in the AO group. The AO group revealed higher maximal principal stress (MPS) values than that of the BD group in the cortical bone, cancellous bone, and crown. The average stress of the outer surface of the abutment was lower in the AO group than in the BD group. The stress distribution for the inner surface of the fixture confirmed that the BD group displayed a lower stress distribution than the AO group under axial and 15° loads; however, the average stress was 1.5 times higher at the 45° load. The stress values of the entire surface where the cortical and cancellous bone were in contact with the fixture were measured. The AO group showed a higher stress value than the BD group in both cortical and cancellous bone. (4) Conclusions: In the AO group, the PVMS value of the fixture and the stress distribution at the contact surface between the fixture and the abutment were lower than those of the BD group, suggesting that the stability of the fixture would be high. However, due to the high stress in the fastening area of the abutment and abutment screw, the risk of abutment fracture in the AO group is higher than that of the BD group. Therefore, the new EZ post non-engaging abutment of the BD implant can be used without any problems in clinics, similar to the non-engaging abutment of the AO implant, which has been widely used in clinical practice.

7.
Biomater Res ; 20: 3, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-26779345

RESUMO

BACKGROUND: This study was to investigate the effect of collagen grafted porous biphasic calcium phosphate (BCP) on cell attachment, proliferation, and differentiation. Porous BCP scaffolds with interconnected micropore structure were prepared with were prepared and then grafted with a collagen type I. The hydroxyapatite (HA) and ß-tricalcium phosphate (TCP) ratio of the TCP scaffolds was about 60/40 and the collagen was crosslinked on the TCP scaffold surface (collagen-TCP). RESULTS: The sintered BCP scaffolds showed fully interconnected micropore structures with submicron-sized grains. The collagen crosslinking in the scaffolds was conducted using the the N-(3-Dimethylaminopropyl)-N'-ethylcarbodiimide hydrochloride and N-hydroxysuccinimide (NHS) crosslinking method. The cell proliferation of collagen-BCP scaffolds showed a similar result to that of the BCP scaffolds. However, osteoblastic differentiation and cell attachment increased in the collagen-BCP scaffolds. CONCLUSIONS: Collagen-BCP scaffold improved the cell attachment ability in early phase and osteoblastic differentiation.

8.
J Adv Prosthodont ; 7(2): 115-21, 2015 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-25932309

RESUMO

PURPOSE: This study aimed to evaluate the effect of implant thread depth on primary stability in low density bone. MATERIALS AND METHODS: The insertion torque was measured by inserting Ti implants with different thread depths into solid rigid polyurethane blocks (Sawbones) with three different bone densities (0.16 g/cm(3), 0.24 g/cm(3), and 0.32 g/cm(3)). The insertion torque value was evaluated with a surgical engine. The static compressive strength was measured with a universal testing machine (UTM) and the Ti implants were aligned at 30° against the loading direction of the UTM. After the static compressive strength test, the Ti implants were analyzed with a Measurescope. RESULTS: The Ti implants with deeper thread depth showed statistically higher mean insertion torque values (P<.001). Groups A and group B had similar maximum static compressive strengths, as did groups C and D (P>.05). After the static compressive strength, the thread shape of the Ti implants with deeper thread depth did not show any breakage but did show deformation of the implant body and abutment. CONCLUSION: The implants with deeper thread depth had higher mean insertion torque values but not lower compressive strength. The deep threads had a mechanical stability. Implants with deeper thread depth may increase the primary stability in areas of poor quality bone without decreasing mechanical strength.

9.
Clin Oral Implants Res ; 23(11): 1283-9, 2012 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-22093072

RESUMO

OBJECTIVES: This study evaluated cytocompatibility and osseointegration of the titanium (Ti) implants with resorbable blast media (RBM) surfaces produced by grit-blasting or XPEED(®) surfaces by coating of the nanostructured calcium. MATERIAL AND METHODS: Ti implants with XPEED(®) surfaces were hydrothermally prepared from Ti implants with RBM surfaces in a solution containing alkaline calcium. The surface characteristics were evaluated by using a scanning electron microscope (SEM) and surface roughness measuring system. Apatite formation was measured with SEM after immersion in modified-simulated body fluid and the amount of calcium released was measured by inductively coupled plasma optical emission. The cell proliferation was investigated by MTT assay and the cell attachment was evaluated by SEM in MC3T3-E1 pre-osteoblast cells. Thirty implants with RBM surfaces and 30 implants with XPEED(®) surfaces were placed in the proximal tibiae and in the femoral condyles of 10 New Zealand White rabbits. The osseointegration was evaluated by a removal torque test in the proximal tibiae and by histomorphometric analysis in the femoral condyles 4 weeks after implantation. RESULTS: The Ti implants with XPEED(®) surfaces showed a similar surface morphology and surface roughness to those of the Ti implants with RBM surfaces. The amount of calcium ions released from the surface of the Ti implants with XPEED(®) surfaces was much more than the Ti implants with RBM surfaces (P < 0.05). The cell proliferation and cell attachment of the Ti implants showed a similar pattern to those of the Ti implants with RBM surfaces (P > 0.1). Apatite deposition significantly increased in all surfaces of the Ti implants with XPEED(®) surfaces. The removable torque value (P = 0.038) and percentage of bone-to-implant contact (BIC%) (P = 0.03) was enhanced in the Ti implants with XPEED(®) surfaces. CONCLUSION: The Ti implants with XPEED(®) surfaces significantly enhanced apatite formation, removal torque value, and the BIC%. The Ti implants with XPEED(®) surfaces may induce strong bone integration by improving osseointegration of grit-blasted Ti implants in areas of poor quality bone.


Assuntos
Implantes Dentários , Osseointegração , Animais , Apatitas/metabolismo , Cálcio/metabolismo , Proliferação de Células , Materiais Revestidos Biocompatíveis , Fêmur/cirurgia , Masculino , Microscopia Eletrônica de Varredura , Coelhos , Propriedades de Superfície , Tíbia/cirurgia , Titânio/metabolismo , Torque
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA