RESUMO
OBJECTIVE: To share our experience of the surgical challenges faced in cochlear implanted patients with inner ear malformation and to assess the auditory and speech perception outcomes. MATERIAL AND METHOD: Clinical records of 502 cochlear implant procedures were reviewed and data of 122 patients who had inner ear malformations were enrolled in the study. Their auditory and speech performances were evaluated post implantation for 3 years. RESULT: Cerebrospinal fluid gusher was encountered during opening of cochlea in 42 patients (34.4%) and one patient was re-explored within 24 h. In 30.3% of cases facial anomaly was found. Significant improvement in average performance was seen in all malformation types except in cochlear hypoplasia at 12 months postoperatively. CONCLUSION: Surgical challenges can be overcome with expertise and giving special attention to preoperative imaging. Our experience suggests that outcomes are favourable in patients with inner ear malformations too.