Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 129
Filtrar
1.
J Biophotonics ; : e202300491, 2024 Apr 25.
Artigo em Inglês | MEDLINE | ID: mdl-38664987

RESUMO

As a rapidly growing field, biophotonics demonstrates an increasingly higher demand for interdisciplinary professionals and requires the implementation of a structured approach to educational and outreach activities focused on appropriate curriculum, and teaching and learning for audiences with diverse technical backgrounds and learning styles. Our study shows the main findings upon applying this approach to biophotonics workshops delivered 2 consecutive years while updating and improving learning outcomes, teaching strategies, workshop content based on student and teacher feedback. We provided resources for a variety of lecture-based, experimental, computer simulation activities. Quality of subject matter, teaching, and overall learning was rated as "Very good" or "Good" by 88%, 76%, and 82% of students in average, respectively. Application of our teaching strategies and materials during short- and long-term workshops/courses could potentially increase the interest in pursuing careers in the biophotonics field and related areas, leading to standardized approaches in designing education and outreach events across centers.

2.
Biomed Opt Express ; 15(4): 2377-2391, 2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-38633072

RESUMO

Identification of tumour margins during resection of the brain is critical for improving the post-operative outcomes. Due to the highly infiltrative nature of glioblastoma multiforme (GBM) and limited intraoperative visualization of the tumour margin, incomplete surgical resection has been observed to occur in up to 80 % of GBM cases, leading to nearly universal tumour recurrence and overall poor prognosis of 14.6 months median survival. This research presents a miniaturized, SiPMT-based optical system for simultaneous measurement of powerful DRS and weak auto-fluorescence for brain tumour detection. The miniaturisation of the optical elements confined the spatial separation of eight select wavelengths into footprint measuring 1.5 × 2 × 16 mm. The small footprint enables this technology to be integrated with existing surgical guidance instruments in the operating room. It's dynamic ability to subtract any background illumination and measure signal intensities across a broad range from pW to mWs make this design much more suitable for clinical environments as compared to spectrometer-based systems with limited dynamic ranges and high integration times. Measurements using optical tissue phantoms containing mixed fluorophores demonstrate correlation coefficients between the fitted response and actual concentration using PLS regression being 0.95, 0.87 and 0.97 for NADH, FAD and PpIX , respectively. These promising results indicate that our proposed miniaturized instrument could serve as an effective alternative in operating rooms, assisting surgeons in identifying brain tumours to achieving positive surgical outcomes for patients.

3.
Biomed Opt Express ; 15(2): 900-909, 2024 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-38404324

RESUMO

Breast cancer is the second leading cause of cancer death in women. Current clinical treatment stratification practices open up an avenue for significant improvements, potentially through advancements in immunohistochemistry (IHC) assessments of biopsies. We report a high contrast upconverting nanoparticles (UCNP) labeling to distinguish different levels of human epidermal growth factor receptor 2 (HER2) in HER2 control pellet arrays (CPAs) and HER2-positive breast cancer tissue. A simple Fourier transform algorithm trained on CPAs was sufficient to provide a semi-quantitative HER2 assessment tool for breast cancer tissues. The UCNP labeling had a signal-to-background ratio of 40 compared to the negative control.

4.
Biomed Opt Express ; 15(2): 863-874, 2024 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-38404353

RESUMO

Phantoms simultaneously mimicking anatomical and optical properties of real tissues can play a pivotal role for improving dosimetry algorithms. The aim of the paper is to design and develop a hybrid phantom model that builds up on the strengths of solid and liquid phantoms for mimicking various anatomical structures for prostate cancer photodynamic therapy (PDT) dosimetry validation. The model comprises of a photosensitizer-embedded gelatin lesion within a liquid Intralipid prostate shape that is surrounded by a solid silicone outer shell. The hybrid phantom was well characterized for optical properties. The final assembled phantom was also evaluated for fluorescence tomographic reconstruction in conjunction with SpectraCure's IDOSE software. The developed model can lead to advancements in dosimetric evaluations. This would improve PDT outlook as a clinical treatment modality and boost phantom based standardization of biophotonic devices globally.

5.
Sci Data ; 11(1): 136, 2024 Jan 26.
Artigo em Inglês | MEDLINE | ID: mdl-38278822

RESUMO

Diffuse reflectance spectroscopy (DRS) has been extensively studied in both preclinical and clinical settings for multiple applications, notably as a minimally invasive diagnostic tool for tissue identification and disease delineation. In this study, extended-wavelength DRS (EWDRS) measurements of ex vivo tissues ranging from ultraviolet through visible to the short-wave infrared region (355-1919 nm) are presented in two datasets. The first dataset contains labelled EWDRS measurements collected from bone cement samples and ovine specimens including 10 tissue types commonly encountered in orthopedic surgeries for data curation purposes. The other dataset includes labelled EWDRS measurements of primarily bone structures at different depths during stepwise drilling into intact porcine skulls until plunging into the cranial cavity. The raw data with code for pre-processing and calibration is publicly available for reuse on figshare. The datasets can be utilized not only for exploratory purposes in machine learning model construction, but also for knowledge discovery in the orthopedic domain to identify important features for surgical guidance, extract physiological parameters and provide diagnostic insights.


Assuntos
Osso e Ossos , Aprendizado de Máquina , Animais , Ovinos , Análise Espectral/métodos , Suínos , Procedimentos Ortopédicos
6.
J Biomed Opt ; 28(11): 115003, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-38078155

RESUMO

Significance: The gas in scattering media absorption spectroscopy (GASMAS) technique has the potential for continuous, clinical monitoring of preterm infant lung function, removing the need for X-ray diagnosis and reliance on indirect and relatively slow measurement of blood oxygenation. Aim: We aim to determine the optimal source-detector configuration for reliable pathlength calculation and to estimate the oxygen gas concentration inside the lung cavities filled with humidified gas with four different oxygen gas concentrations ranging between 21% and 100%. Approach: Anthropomorphic optical phantoms of neonatal thorax with two different geometries were used to acquire GASMAS signals, for 30 source-detector configurations in transmittance and remittance geometry of phantoms in two sizes. Results: The results show that an internal light administration is more likely to provide a high GASMAS signal-to-noise ratio (SNR). In general, better SNRs were obtained with the smaller set of phantoms. The values of pathlength and O2 concentrations calculated with signals from the phantoms with optical properties at 820 nm exhibit higher variations than signals from the phantoms with optical properties at 764 nm. Conclusion: Our study shows that, by moving the source and detector over the thorax, most of the lung volumes can potentially be assessed using the GASMAS technique.


Assuntos
Recém-Nascido Prematuro , Oxigênio , Recém-Nascido , Humanos , Análise Espectral/métodos , Imagens de Fantasmas , Gases , Pulmão/diagnóstico por imagem , Lasers
7.
J Biomed Opt ; 28(12): 121201, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-38074215

RESUMO

The editorial introduces the JBO Special Section on Selected Topics in Biophotonics: Translating Novel Photonics Technology into Clinical Applications.


Assuntos
Óptica e Fotônica , Tecnologia
8.
Analyst ; 149(1): 88-99, 2023 Dec 18.
Artigo em Inglês | MEDLINE | ID: mdl-37994161

RESUMO

Colorectal cancer (CRC) is the third most common and second most deadly type of cancer worldwide, representing 11.3% of the diagnosed cancer cases and resulting in 10.2% (0.88 million) of the cancer related deaths in 2020. CRCs are typically detected at the late stage, which leads to high mortality and morbidity. Mortality and poor prognosis are partially caused by cancer recurrence and postoperative complications. Patient survival could be increased by improving precision in surgical resection using accurate surgical guidance tools based on diffuse reflectance spectroscopy (DRS). DRS enables real-time tissue identification for potential cancer margin delineation through determination of the circumferential resection margin (CRM), while also supporting non-invasive and label-free approaches for laparoscopic surgery to avoid short-term complications of open surgery as suitable. In this study, we have estimated the scattering properties and chromophore concentrations based on 2949 DRS measurements of freshly excised ex vivo specimens of 47 patients, and used this estimation to classify normal colorectal wall (CW), fat and tumor tissues. DRS measurements were performed with fiber-optic probes of 630 µm source-detector distance (SDD; probe 1) and 2500 µm SDD (probe 2) to measure tissue layers ∼0.5-1 mm and ∼0.5-2 mm deep, respectively. By using the 5-fold cross-validation of machine learning models generated with the classification and regression tree (CART) algorithm, we achieved 95.9 ± 0.7% sensitivity, 98.9 ± 0.3% specificity, 90.2 ± 0.4% accuracy, and 95.5 ± 0.3% AUC for probe 1. Similarly, we achieved 96.9 ± 0.8% sensitivity, 98.9 ± 0.2% specificity, 94.0 ± 0.4% accuracy, and 96.7 ± 0.4% AUC for probe 2.


Assuntos
Neoplasias Colorretais , Tecnologia de Fibra Óptica , Humanos , Análise Espectral/métodos , Biomarcadores , Neoplasias Colorretais/diagnóstico , Neoplasias Colorretais/cirurgia
9.
J Biomed Opt ; 28(12): 121207, 2023 12.
Artigo em Inglês | MEDLINE | ID: mdl-37674977

RESUMO

Significance: Wavelength selection from a large diffuse reflectance spectroscopy (DRS) dataset enables removal of spectral multicollinearity and thus leads to improved understanding of the feature domain. Feature selection (FS) frameworks are essential to discover the optimal wavelengths for tissue differentiation in DRS-based measurements, which can facilitate the development of compact multispectral optical systems with suitable illumination wavelengths for clinical translation. Aim: The aim was to develop an FS methodology to determine wavelengths with optimal discriminative power for orthopedic applications, while providing the frameworks for adaptation to other clinical scenarios. Approach: An ensemble framework for FS was developed, validated, and compared with frameworks incorporating conventional algorithms, including principal component analysis (PCA), linear discriminant analysis (LDA), and backward interval partial least squares (biPLS). Results: Via the one-versus-rest binary classification approach, a feature subset of 10 wavelengths was selected from each framework yielding comparable balanced accuracy scores (PCA: 94.8±3.47%, LDA: 98.2±2.02%, biPLS: 95.8±3.04%, and ensemble: 95.8±3.16%) to those of using all features (100%) for cortical bone versus the rest class labels. One hundred percent balanced accuracy scores were generated for bone cement versus the rest. Different feature subsets achieving similar outcomes could be identified due to spectral multicollinearity. Conclusions: Wavelength selection frameworks provide a means to explore domain knowledge and discover important contributors to classification in spectroscopy. The ensemble framework generated a model with improved interpretability and preserved physical interpretation, which serves as the basis to determine illumination wavelengths in optical instrumentation design.


Assuntos
Imagem Óptica , Procedimentos Ortopédicos , Análise Espectral , Algoritmos , Análise Discriminante , Análise Espectral/métodos , Imagem Óptica/instrumentação , Análise de Componente Principal
10.
Analyst ; 148(19): 4768-4776, 2023 Sep 25.
Artigo em Inglês | MEDLINE | ID: mdl-37665320

RESUMO

Rapid advancement of novel optical spectroscopy and imaging systems relies on the availability of well-characterised and reproducible protocols for phantoms as a standard for the validation of the technique. The tissue-mimicking phantoms are also used to investigate photon transport in biological samples before clinical trials that require well-characterized phantoms with known optical properties (reduced scattering (µ's) and absorption (µa) coefficients). However, at present, there is limited literature available providing well-characterized phantom recipes considering various biomarkers and tested over a wide range of optical properties covering most of the human organs and applicable to multimodal optical spectroscopy. In this study, gelatin-based phantoms were designed to simulate tissue optical properties where India ink and Intralipid were used as absorbing and scattering agents, respectively. Multiple biomarkers were simulated by varying the gelatin concentration to mimic the change in tissue hydration and hydroxyapatite concentration to mimic bone signature. The recipe along with biomarkers were optimized and characterised over a wide range of optical properties (µa from 0.1 to 0.5 cm-1; µ's from 5 to 15 cm-1) relevant to human tissue using a broadband time-domain diffuse optical spectrometer. The data collected showed a linear relationship between the concentration of ink/lipids and µa/µ's values with negligible coupling between µa and µ's values. While being stored in a refrigerator post-fabrication, the µa and µ's did not change significantly (<4% coefficient of variation, 'CV') over three weeks. The reproducibility in three different sets was validated experimentally and found to be strong with a variation of ≤6% CV in µa and ≤9% CV in µ's. From the 3 × 3 data of µa and µ's matrices, one can deduce the recipe for any target absorption or reduced scattering coefficient. The applicability of the phantoms was tested using diffuse reflectance and Raman spectrometers. A use case application was demonstrated for Raman spectroscopy where hydration and hydroxyapatite phantoms were designed to characterize the Raman instrument. The Raman instrument could detect the change in 1% of HA and 5% of hydration. This study presents a first-of-its-kind robust, well-characterized, multi-biomarker phantom recipe for calibration and benchmarking of multimodal spectroscopy devices assisting in their clinical translation.


Assuntos
Gelatina , Análise Espectral Raman , Humanos , Reprodutibilidade dos Testes , Biomarcadores , Durapatita
11.
Micromachines (Basel) ; 14(5)2023 May 17.
Artigo em Inglês | MEDLINE | ID: mdl-37241685

RESUMO

In vivo tissue imaging is an essential tool for medical diagnosis, surgical guidance, and treatment. However, specular reflections caused by glossy tissue surfaces can significantly degrade image quality and hinder the accuracy of imaging systems. In this work, we further the miniaturisation of specular reflection reduction techniques using micro cameras, which have the potential to act as intra-operative supportive tools for clinicians. In order to remove these specular reflections, two small form factor camera probes, handheld at 10 mm footprint and miniaturisable to 2.3 mm, are developed using different modalities, with line-of-sight to further miniaturisation. (1) The sample is illuminated via multi-flash technique from four different positions, causing a shift in reflections which are then filtered out in a post-processing image reconstruction step. (2) The cross-polarisation technique integrates orthogonal polarisers onto the tip of the illumination fibres and camera, respectively, to filter out the polarisation maintaining reflections. These form part of a portable imaging system that is capable of rapid image acquisition using different illumination wavelengths, and employs techniques that lend themselves well to further footprint reduction. We demonstrate the efficacy of the proposed system with validating experiments on tissue-mimicking phantoms with high surface reflection, as well as on excised human breast tissue. We show that both methods can provide clear and detailed images of tissue structures along with the effective removal of distortion or artefacts caused by specular reflections. Our results suggest that the proposed system can improve the image quality of miniature in vivo tissue imaging systems and reveal underlying feature information at depth, for both human and machine observers, leading to better diagnosis and treatment outcomes.

12.
Analyst ; 148(7): 1514-1523, 2023 Mar 27.
Artigo em Inglês | MEDLINE | ID: mdl-36896767

RESUMO

Early diagnosis of oral cancer is critical to improve the survival rate of patients. Raman spectroscopy, a non-invasive spectroscopic technique, has shown potential in identifying early-stage oral cancer biomarkers in the oral cavity environment. However, inherently weak signals necessitate highly sensitive detectors, which restricts widespread usage due to high setup costs. In this research, the fabrication and assembly of a customised Raman system that can adapt three different configurations for the in vivo and ex vivo analysis is reported. This novel design will help in reducing the cost required to have multiple Raman instruments specific for a given application. First, we demonstrated the capability of a customized microscope for acquiring Raman signals from a single cell with high signal-to-noise ratio. Generally, when working with liquid samples with low concentration of analytes (such as saliva) under a microscope, excitation light interacts with a small sample volume, which may not be representative of whole sample. To address this issue, we have designed a novel long-path transmission set-up, which was found to be sensitive towards low concentration of analytes in aqueous solution. We further demonstrated that the same Raman system can be incorporated with the multimodal fibre optical probe to collect in vivo data from oral tissues. In summary, this flexible, portable, multi-configuration Raman system has the potential to provide a cost-effective solution for complete screening of precancer oral lesions.


Assuntos
Neoplasias Bucais , Humanos , Neoplasias Bucais/diagnóstico , Razão Sinal-Ruído , Análise Espectral Raman/métodos , Microscopia
13.
J Biomed Opt ; 28(3): 036004, 2023 03.
Artigo em Inglês | MEDLINE | ID: mdl-36915372

RESUMO

Significance: Phantoms play a critical role in the development of biophotonics techniques. There is a lack of novel phantom tools in the emerging field of upconverting nanoparticles (UCNPs) for biophotonics application. This work provides a range of UCNP-based phantom tools and a manufacturing recipe to bridge the gap and accelerate the development of UCNP-based biophotonics applications. Aim: The study aims to provide a well-characterized UCNP-based solid phantom recipe and set of phantom tools to address a wide range of UCNP-based biophotonics applications. Approach: A solid phantom recipe based on silicone matrix was developed to manufacture UCNP-based phantoms. A lab built UCNP imaging system was used to characterize upconverted fluorescence emission of phantoms for linearity, homogeneity, and long-term stability. A photon time-of-flight spectroscopy technique was used to characterize the optical properties of the phantoms. Results: In total, 24 phantoms classified into 4 types, namely homogeneous, multilayer, inclusion, and base phantoms, were manufactured. The phantoms exhibit linear behavior over the dosage range of UCNPs. The phantoms were found to be stable over a limited observed period of 4 months with a coefficient of variation of < 4 % . The deep tissue imaging case showed that increasing the thickness of tissue reduced the UCNP emission. Conclusions: A first-of-its-kind UCNP-based solid phantom recipe was developed, and four types of UCNP phantom tools to explore biophotonics applications were presented. The UCNP phantoms exhibited a linear behavior with dosage and were stable over time. An example case showed the potential use of the phantom for deep tissue imaging applications. With recent advance in the use of UCNPs for biophotonics, we believe our recipe and tools will play a pivotal role in the growth of the UCNPs for biophotonics applications.


Assuntos
Nanopartículas , Nanopartículas/química , Imagens de Fantasmas , Diagnóstico por Imagem , Fótons , Fluorescência
14.
Gut Microbes ; 15(1): 2163838, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-36656595

RESUMO

Conflicting evidence exists on the association between consumption of non-steroidal anti-inflammatory drugs (NSAIDs) and symptomatic worsening of inflammatory bowel disease (IBD). We hypothesized that the heterogeneous prevalence of pathobionts [e.g., adherent-invasive Escherichia coli (AIEC)], might explain this inconsistent NSAIDs/IBD correlation. Using IL10-/- mice, we found that NSAID aggravated colitis in AIEC-colonized animals. This was accompanied by activation of the NLRP3 inflammasome, Caspase-8, apoptosis, and pyroptosis, features not seen in mice exposed to AIEC or NSAID alone, revealing an AIEC/NSAID synergistic effect. Inhibition of NLRP3 or Caspase-8 activity ameliorated colitis, with reduction in NLRP3 inflammasome activation, cell death markers, activated T-cells and macrophages, improved histology, and increased abundance of Clostridium cluster XIVa species. Our findings provide new insights into how NSAIDs and an opportunistic gut-pathobiont can synergize to worsen IBD symptoms. Targeting the NLRP3 inflammasome or Caspase-8 could be a potential therapeutic strategy in IBD patients with gut inflammation, which is worsened by NSAIDs.


Assuntos
Anti-Inflamatórios não Esteroides , Colite , Microbioma Gastrointestinal , Doenças Inflamatórias Intestinais , Animais , Camundongos , Anti-Inflamatórios não Esteroides/efeitos adversos , Caspase 8/metabolismo , Colite/induzido quimicamente , Colite/tratamento farmacológico , Colite/microbiologia , Inflamassomos , Doenças Inflamatórias Intestinais/tratamento farmacológico , Doenças Inflamatórias Intestinais/microbiologia , Proteína 3 que Contém Domínio de Pirina da Família NLR/metabolismo , Inibidores de Caspase/farmacologia , Escherichia coli/patogenicidade
15.
Diagnostics (Basel) ; 12(12)2022 Nov 22.
Artigo em Inglês | MEDLINE | ID: mdl-36552903

RESUMO

Oral cancer is the 16th most common cancer worldwide. It commonly arises from painless white or red plaques within the oral cavity. Clinical outcome is highly related to the stage when diagnosed. However, early diagnosis is complex owing to the impracticality of biopsying every potentially premalignant intraoral lesion. Therefore, there is a need to develop a non-invasive cost-effective diagnostic technique to differentiate non-malignant and early-stage malignant lesions. Optical spectroscopy may provide an appropriate solution to facilitate early detection of these lesions. It has many advantages over traditional approaches including cost, speed, objectivity, sensitivity, painlessness, and ease-of use in clinical setting for real-time diagnosis. This review consists of a comprehensive overview of optical spectroscopy for oral cancer diagnosis, epidemiology, and recent improvements in this field for diagnostic purposes. It summarizes major developments in label-free optical spectroscopy, including Raman, fluorescence, and diffuse reflectance spectroscopy during recent years. Among the wide range of optical techniques available, we chose these three for this review because they have the ability to provide biochemical information and show great potential for real-time deep-tissue point-based in vivo analysis. This review also highlights the importance of saliva-based potential biomarkers for non-invasive early-stage diagnosis. It concludes with the discussion on the scope of development and future demands from a clinical point of view.

16.
Cancers (Basel) ; 14(22)2022 Nov 21.
Artigo em Inglês | MEDLINE | ID: mdl-36428806

RESUMO

Colorectal cancer (CRC) is the third most common and second most deadly type of cancer worldwide. Early detection not only reduces mortality but also improves patient prognosis by allowing the use of minimally invasive techniques to remove cancer while avoiding major surgery. Expanding the use of microsurgical techniques requires accurate diagnosis and delineation of the tumor margins in order to allow complete excision of cancer. We have used diffuse reflectance spectroscopy (DRS) to identify the main optical CRC biomarkers and to optimize parameters for the integration of such technologies into medical devices. A total number of 2889 diffuse reflectance spectra were collected in ex vivo specimens from 47 patients. Short source-detector distance (SDD) and long-SDD fiber-optic probes were employed to measure tissue layers from 0.5 to 1 mm and from 0.5 to 1.9 mm deep, respectively. The most important biomolecules contributing to differentiating DRS between tissue types were oxy- and deoxy-hemoglobin (Hb and HbO2), followed by water and lipid. Accurate tissue classification and potential DRS device miniaturization using Hb, HbO2, lipid and water data were achieved particularly well within the wavelength ranges 350-590 nm and 600-1230 nm for the short-SDD probe, and 380-400 nm, 420-610 nm, and 650-950 nm for the long-SDD probe.

17.
Opt Express ; 30(10): 16572-16584, 2022 May 09.
Artigo em Inglês | MEDLINE | ID: mdl-36221497

RESUMO

Non-linear materials such as upconverting nanoparticles (UCNPs) are emerging technology with fast-growing applications in various fields. The power density dependence of the emission quantum yield (QY) of these non-linear materials makes them challenging to characterize using currently available commercial QY systems. We propose a multimodal system to measure QY over a wide dynamic range (1:104), which takes into account and compensates for various distorting parameters (scattering, beam profile, inner filter effect and bandwidth of emission lines). For this, a beam shaping approach enabling speckle free beam profiles of two different sizes (530 µm or 106 µm) was employed. This provides low noise high-resolution QY curves. In particular, at low power densities, a signal-to-noise ratio of >50 was found. A Tm-based core-shell UCNP with excitation at 976 nm and emission at 804 nm was investigated with the system.

18.
Biosensors (Basel) ; 12(10)2022 Sep 26.
Artigo em Inglês | MEDLINE | ID: mdl-36290930

RESUMO

This work is an overview of silicon photomultipliers (SiPMs) with a view to defining their importance for bio-photonic and clinical applications. SiPMs are benchmarked against other common photodetectors, namely, PIN diodes and avalanche photodetectors (APDs) and are compared with respect to important circuit design parameters. It will be shown that careful selection of the design bias voltage, overvoltage, gain defining components and device integration to micro-optics can allow SiPM detectors to achieve considerable sensitivity for auto-fluorescence (AF) detection and a wide dynamic range at low optical powers (~1 pW to ~4 µW). The SiPM has a manageable bias voltage (~25 V to ~30 V DC) for systems integration, and with optimised sensitivity it will enhance bio-photonic research in the area of AF to detect intraoperatively, for example, brain tumour margins.


Assuntos
Óptica e Fotônica , Fótons
19.
J Biomed Opt ; 27(5)2022 05.
Artigo em Inglês | MEDLINE | ID: mdl-35599336

RESUMO

The guest editorial introduces the Journal of Biomedical Optics special collection, Perspectives in Biophotonics, https://www.spiedigitallibrary.org/biophotonics-tutorials.


Assuntos
Óptica e Fotônica , Instituições Acadêmicas
20.
Pediatr Res ; 92(5): 1240-1246, 2022 11.
Artigo em Inglês | MEDLINE | ID: mdl-35606473

RESUMO

Gas in scattering media absorption spectroscopy (GASMAS) is a novel optical technology employing near-infrared light. It has a potential use in the medical setting as a monitoring and diagnostic tool by detecting molecular oxygen within gas pockets and thus may be a useful adjunct in respiratory monitoring. GASMAS has potential advantages over other monitoring devices currently used in clinical practice. It is a non-invasive, continuous, non-ionising technology and provides unique information about molecular oxygen content inside the lungs. GASMAS may have a future role in optimising respiratory management of neonates in different clinical scenarios such as monitoring cardiorespiratory transition in the delivery room, assessing surfactant deficiency, and optimising endotracheal tube positioning. This article aims to summarise current evidence exploring GASMAS application in a neonate, discuss possible clinical benefits, and compare with other devices that are currently used in neonatal care. IMPACT: This article presents a novel optical technique to measure lung oxygen concentrations that may have important clinical uses. This review summarises the current literature investigating the concept of optical lung oxygen measurement. Information from this review can guide researchers in future studies.


Assuntos
Gases , Oxigênio , Recém-Nascido , Humanos , Análise Espectral/métodos , Oxigênio/química , Monitorização Fisiológica/métodos , Taxa Respiratória
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA