Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
1.
Lancet ; 403(10429): 824-837, 2024 Mar 02.
Artigo em Inglês | MEDLINE | ID: mdl-38401549

RESUMO

BACKGROUND: Previous meta-analyses have shown reduced risks of composite adverse events with intravascular imaging-guided percutaneous coronary intervention (PCI) compared with angiography guidance alone. However, these studies have been insufficiently powered to show whether all-cause death or all myocardial infarction are reduced with intravascular imaging guidance, and most previous intravascular imaging studies were done with intravascular ultrasound rather than optical coherence tomography (OCT), a newer imaging modality. We aimed to assess the comparative performance of intravascular imaging-guided PCI and angiography-guided PCI with drug-eluting stents. METHODS: For this systematic review and updated meta-analysis, we searched the MEDLINE, Embase, and Cochrane databases from inception to Aug 30, 2023, for studies that randomly assigned patients undergoing PCI with drug-eluting stents either to intravascular ultrasound or OCT, or both, or to angiography alone to guide the intervention. The searches were done and study-level data were extracted independently by two investigators. The primary endpoint was target lesion failure, defined as the composite of cardiac death, target vessel-myocardial infarction (TV-MI), or target lesion revascularisation, assessed in patients randomly assigned to intravascular imaging guidance (intravascular ultrasound or OCT) versus angiography guidance. We did a standard frequentist meta-analysis to generate direct data, and a network meta-analysis to generate indirect data and overall treatment effects. Outcomes were expressed as relative risks (RRs) with 95% CIs at the longest reported follow-up duration. This study was registered with the international prospective register of systematic reviews (PROSPERO, number CRD42023455662). FINDINGS: 22 trials were identified in which 15 964 patients were randomised and followed for a weighted mean duration of 24·7 months (longest duration of follow-up in each study ranging from 6 to 60 months). Compared with angiography-guided PCI, intravascular imaging-guided PCI resulted in a decreased risk of target lesion failure (RR 0·71 [95% CI 0·63-0·80]; p<0·0001), driven by reductions in the risks of cardiac death (RR 0·55 [95% CI 0·41-0·75]; p=0·0001), TV-MI (RR 0·82 [95% CI 0·68-0·98]; p=0·030), and target lesion revascularisation (RR 0·72 [95% CI 0·60-0·86]; p=0·0002). Intravascular imaging guidance also reduced the risks of stent thrombosis (RR 0·52 [95% CI 0·34-0·81]; p=0·0036), all myocardial infarction (RR 0·83 [95% CI 0·71-0·99]; p=0·033), and all-cause death (RR 0·75 [95% CI 0·60-0·93]; p=0·0091). Outcomes were similar for OCT-guided and intravascular ultrasound-guided PCI. INTERPRETATION: Compared with angiography guidance, intravascular imaging guidance of coronary stent implantation with OCT or intravascular ultrasound enhances both the safety and effectiveness of PCI, reducing the risks of death, myocardial infarction, repeat revascularisation, and stent thrombosis. FUNDING: Abbott.


Assuntos
Stents Farmacológicos , Eritema Multiforme , Infarto do Miocárdio , Intervenção Coronária Percutânea , Trombose , Humanos , Angiografia , Metanálise em Rede , Ensaios Clínicos Controlados Aleatórios como Assunto
2.
N Engl J Med ; 389(16): 1477-1487, 2023 Oct 19.
Artigo em Inglês | MEDLINE | ID: mdl-37634149

RESUMO

BACKGROUND: Imaging-guided percutaneous coronary intervention (PCI) is associated with better clinical outcomes than angiography-guided PCI. Whether routine optical coherence tomography (OCT) guidance in PCI of lesions involving coronary-artery branch points (bifurcations) improves clinical outcomes as compared with angiographic guidance is uncertain. METHODS: We conducted a multicenter, randomized, open-label trial at 38 centers in Europe. Patients with a clinical indication for PCI and a complex bifurcation lesion identified by means of coronary angiography were randomly assigned in a 1:1 ratio to OCT-guided PCI or angiography-guided PCI. The primary end point was a composite of major adverse cardiac events (MACE), defined as death from a cardiac cause, target-lesion myocardial infarction, or ischemia-driven target-lesion revascularization at a median follow-up of 2 years. RESULTS: We assigned 1201 patients to OCT-guided PCI (600 patients) or angiography-guided PCI (601 patients). A total of 111 patients (18.5%) in the OCT-guided PCI group and 116 (19.3%) in the angiography-guided PCI group had a bifurcation lesion involving the left main coronary artery. At 2 years, a primary end-point event had occurred in 59 patients (10.1%) in the OCT-guided PCI group and in 83 patients (14.1%) in the angiography-guided PCI group (hazard ratio, 0.70; 95% confidence interval, 0.50 to 0.98; P = 0.035). Procedure-related complications occurred in 41 patients (6.8%) in the OCT-guided PCI group and 34 patients (5.7%) in the angiography-guided PCI group. CONCLUSIONS: Among patients with complex coronary-artery bifurcation lesions, OCT-guided PCI was associated with a lower incidence of MACE at 2 years than angiography-guided PCI. (Funded by Abbott Vascular and others; OCTOBER ClinicalTrials.gov number, NCT03171311.).


Assuntos
Angiografia Coronária , Doença da Artéria Coronariana , Intervenção Coronária Percutânea , Tomografia de Coerência Óptica , Humanos , Angiografia Coronária/efeitos adversos , Angiografia Coronária/métodos , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/terapia , Intervenção Coronária Percutânea/efeitos adversos , Intervenção Coronária Percutânea/métodos , Tomografia de Coerência Óptica/efeitos adversos , Tomografia de Coerência Óptica/métodos , Resultado do Tratamento , Europa (Continente)
3.
Catheter Cardiovasc Interv ; 101(4): 787-797, 2023 03.
Artigo em Inglês | MEDLINE | ID: mdl-36740229

RESUMO

AIMS: Early healing after drug-eluting stent (DES) implantation may reduce the risk of stent thrombosis. The aim of this study was to compare patterns of early healing after implantation of the thin strut everolimus-eluting Synergy DES (Boston Scientific) or the biolimus-eluting Biomatix Neoflex DES (Biosensors). METHODS AND RESULTS: A total of 160 patients with the chronic or acute coronary syndrome were randomized 1:1 to Synergy or Biomatrix DES. Optical coherence tomography (OCT) was performed at baseline and at either 1- or 3-month follow-up. The primary endpoint was a coronary stent healing index (CSHI), a weighted index of strut coverage, neointimal hyperplasia, malapposition, and extrastent lumen. A total of 133 cases had OCT follow-up and 119 qualified for matched OCT analysis. The median CSHI score did neither differ significantly between the groups at 1 month: Synergy 8.0 (interquartile range [IQR]: 3.0; 14.0) versus Biomatrix 8.5 (IQR: 4.0; 15.0) (p = 0.47) nor at 3 months: Synergy 6.5 (IQR: 2.0; 13.0) versus Biomatrix 6.0 (IQR: 4.0; 11.0) (p = 0.83). Strut coverage was 84.6% (IQR: 72.0; 97.9) for Synergy versus 77.6% (IQR: 70.1; 90.3) for Biomatrix (p = 0.15) at 1 month and 90.3% (IQR 79.0; 98.8) (Synergy) versus 83.9% (IQR: 77.5; 92.6) (Biomatrix) (p = 0.068) at 3 months. Pooled 1- and 3-month coverage was 88.6% (IQR: 74.4; 98.4) for Synergy compared with 80.7% (IQR: 73.2; 90.8) for Biomatrix (p = 0.02). CONCLUSIONS: The early healing response after treatment with the Synergy or Biomatrix DES did not differ significantly as determined by a healing index. The Synergy DES showed overall better early stent strut coverage.


Assuntos
Doença da Artéria Coronariana , Stents Farmacológicos , Intervenção Coronária Percutânea , Humanos , Everolimo , Doença da Artéria Coronariana/terapia , Polímeros , Implantes Absorvíveis , Resultado do Tratamento , Desenho de Prótese , Tomografia de Coerência Óptica
4.
Catheter Cardiovasc Interv ; 99(4): 1075-1083, 2022 03.
Artigo em Inglês | MEDLINE | ID: mdl-34967094

RESUMO

OBJECTIVES: To evaluate the feasibility, safety, and healing response of a magnesium-based bioresorbable scaffold (BRS) in the treatment of simple bifurcation lesions using the single stent provisional technique. BACKGROUND: BRS may hold potential advantages in the treatment of coronary bifurcation lesions, however low radial strength and expansion capacity has been an issue with polymer-based scaffolds. The magnesium BRS may prove suitable for bifurcation treatment as its mechanical properties are closer to those of permanent metallic drug-eluting stents. METHODS: The study was a proof-of-concept study with planned inclusion of 20 patients with stable angina pectoris and a bifurcation lesion involving a large side branch (SB) > 2.5 mm with less than 50% diameter stenosis. Procedure and healing response were evaluated by optical coherence tomography (OCT). The main endpoints were a composite clinical safety endpoint and an OCT healing index at 1 month (range: 0-98). RESULTS: Eleven patients were included in the study. The study was prematurely terminated due to scaffold fractures and embolization of scaffold fragments in three cases requiring bailout stenting with drug-eluting stents. One patient underwent bypass surgery at 3 months due to stenosis proximal to the study segment. All SB were patent for 1 month. One-month OCT evaluation showed strut coverage of 96.9% and no malapposition. Scaffold fractures and uncovered jailing struts resulted in a less favorable mean OCT healing index score of 10.4 ± 9.0. CONCLUSIONS: Implanting a magnesium scaffold by the provisional technique in nontrue bifurcation lesions was associated with scaffold fracture, embolization of scaffold fragments, and a high need for bailout stenting.


Assuntos
Doença da Artéria Coronariana , Intervenção Coronária Percutânea , Implantes Absorvíveis , Constrição Patológica , Angiografia Coronária/métodos , Doença da Artéria Coronariana/cirurgia , Doença da Artéria Coronariana/terapia , Vasos Coronários/diagnóstico por imagem , Vasos Coronários/cirurgia , Humanos , Magnésio , Intervenção Coronária Percutânea/efeitos adversos , Desenho de Prótese , Alicerces Teciduais , Tomografia de Coerência Óptica/métodos , Resultado do Tratamento
5.
Catheter Cardiovasc Interv ; 96(1): 31-39, 2020 07.
Artigo em Inglês | MEDLINE | ID: mdl-32087046

RESUMO

OBJECTIVES: In a coronary bifurcation bench model, to determine the effects of side branch (SB) wire crossing position and balloon position on the stent scaffolding after the final proximal optimization technique (POT). BACKGROUND: POT performed as a final step after SB dilatation or kissing balloon inflation (KBI) has been widely advocated despite limited evidence. METHODS: Thirty-one stent implantations in bifurcation phantoms were performed using a one-stent provisional technique with (KBI) (n = 13), with POT-side-POT technique (n = 12) or with the two-stent culotte technique (n = 6). SB wiring was performed through either a proximal or a distal stent cell and confirmed by optical coherence tomography. Final POT was performed with the balloon positioned either across or proximal to the SB takeoff. The area of the opened stent cell in front of the SB was assessed by 3D reconstructed microcomputation tomography scans performed before and after Final POT. RESULTS: In cases with metallic carina, final POT across the SB takeoff caused SB rejailing. Regardless of stent technique and wire position, a Final POT across the SB takeoff reduced the SB cell opening area by 43% [32%;58%] (n = 15). The largest reduction (54-70%) was found after the POT-side-POT technique in procedures with a proximal wiring. Final POT performed proximal to the SB takeoff caused limited or no SB cell opening area reduction (4% [0.6%;6%] [n = 16]). CONCLUSION: Final POT with balloon positioned across the SB takeoff in a narrow angle bifurcation reduces largest stent cell area in front of the SB ostium and may cause SB rejailing in cases with metallic carina.


Assuntos
Angioplastia Coronária com Balão/instrumentação , Vasos Coronários , Stents Farmacológicos , Angioplastia Coronária com Balão/efeitos adversos , Vasos Coronários/diagnóstico por imagem , Humanos , Teste de Materiais , Modelos Anatômicos , Modelos Cardiovasculares , Desenho de Prótese
6.
Eur Heart J Cardiovasc Imaging ; 19(3): 329-338, 2018 03 01.
Artigo em Inglês | MEDLINE | ID: mdl-28369332

RESUMO

Aims: To show non-inferiority of the 67- or 87 µm thick, sirolimus-eluting Orsiro drug eluting stent (DES) to the 122 µm thick, biolimus-eluting Nobori DES regarding size of vessel lumen outside the stent at 13-month follow-up. Methods and results: This study was a substudy to the SORT-OUT VII trial, a prospective, 1:1-randomized, comparison of the two stents in patients with stable coronary artery disease or acute coronary syndrome. Optical coherence tomography was acquired after percutaneous coronary intervention and at 13-month follow-up. The substudy was powered to access non-inferiority (Δ = 0.60 mm2) of the Orsiro DES to the Nobori DES for the primary endpoint of mean extra stent lumen (ESL) i.e. vessel lumen outside the stent at 13-month follow-up. We randomized 124 patients to Orsiro (n = 60) or Nobori (n = 64). Due to a difference in the one-sided 95%-confidence interval of 0.26 mm2, but increased to 0.82 mm2 after appropriate log-transformation, it could not be rejected that Orsiro exceeded the non-inferiority limit. Testing for superiority, Orsiro had a significantly larger mean ESL at follow-up (Orsiro: 0.11 mm2 [0.02;0.30] mm2, Nobori: 0.03 mm2 [0.00;0.17] mm2, P = 0.04). Stent strut coverage was, Orsiro: 97.6 % [93.8;99.4]%, and Nobori: 96.3 % [90.5;98,6]% (P = 0.13). Conclusion: Orsiro DES had a significantly larger mean ESL at follow-up and it could not be excluded that Orsiro exceeded the limit for non-inferiority. Nobori DES had a more heterogeneous distribution of neointima but stent strut coverage did not differ significantly between the two stents.


Assuntos
Estenose Coronária/diagnóstico por imagem , Estenose Coronária/terapia , Stents Farmacológicos , Sirolimo/análogos & derivados , Sirolimo/farmacologia , Tomografia de Coerência Óptica/métodos , Implantes Absorvíveis , Angioplastia Coronária com Balão/métodos , Feminino , Seguimentos , Humanos , Masculino , Neointima/diagnóstico por imagem , Neointima/patologia , Distribuição Normal , Polímeros , Estudos Prospectivos , Desenho de Prótese , Valores de Referência , Medição de Risco , Índice de Gravidade de Doença , Estatísticas não Paramétricas , Fatores de Tempo , Resultado do Tratamento , Grau de Desobstrução Vascular/fisiologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA