Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
1.
J Matern Fetal Neonatal Med ; 35(14): 2759-2764, 2022 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-32727248

RESUMO

OBJECTIVES: To evaluate the accuracy and reliability of a new ultrasound technique for the automatic assessment of the head-perineum distance (HPD) during childbirth. METHODS: HPD was measured on a total of 40 acquisition sessions in 30 laboring women both automatically by an innovative algorithm and manually by trained sonographers, assumed as gold standard. RESULTS: A significant correlation was found between manual and automatic measurements (Intra-CC = 0.994). High values of the coefficient of determination (r2=0.98) and low residual errors: RMSE = 2.01 mm (4.9%) were found. CONCLUSION: The automatic algorithm for the assessment of the HPD represents a reliable technique.


Assuntos
Trabalho de Parto , Períneo , Parto Obstétrico , Feminino , Humanos , Apresentação no Trabalho de Parto , Períneo/diagnóstico por imagem , Gravidez , Reprodutibilidade dos Testes , Ultrassonografia Pré-Natal/métodos
2.
Acta Biomed ; 92(S1): e2021119, 2021 05 04.
Artigo em Inglês | MEDLINE | ID: mdl-33944816

RESUMO

Reversible Cerebral Vasoconstriction Syndrome (RCVS) and Posterior Reversible Encephalopathy Syndrome (PRES) are two rare neurological conditions, clinically characterized by headache. In our case a diagnosis of PDPH was made though imaging showed signs of RCVS-PRES. We present a case of RCVS-PRES in a postpartum woman who presented headache as first symptom and only later experienced seizures. Dural puncture worked as a confounding factor in the clinical postpartum evaluation. We want to focus the attention on changes of clinical characteristics of headache as an important factor to be analysed, in order to have a prompt diagnosis. We therefore propose a diagnostic algorithm. Moreover, we evaluate possible triggers of RCVS and PRES; in our case dural puncture is probably not the trigger, in fact there were no liquoral hypotension signs on imaging.


Assuntos
Cefaleia Pós-Punção Dural , Síndrome da Leucoencefalopatia Posterior , Feminino , Cefaleia/etiologia , Humanos , Cefaleia Pós-Punção Dural/etiologia , Síndrome da Leucoencefalopatia Posterior/diagnóstico por imagem , Síndrome da Leucoencefalopatia Posterior/etiologia , Período Pós-Parto , Punções , Vasoconstrição
3.
Acta Obstet Gynecol Scand ; 100(5): 876-883, 2021 05.
Artigo em Inglês | MEDLINE | ID: mdl-33084031

RESUMO

INTRODUCTION: Fetal growth restriction (FGR) in most instances is a consequence of primary placental dysfunction due to inadequate trophoblastic invasion. Maternal cardiac maladaptation to pregnancy has been proposed as a possible determinant of placental insufficiency and impaired fetal growth. This study aimed to compare the maternal hemodynamic parameters between normotensive women with small-for-gestational-age (SGA) and FGR fetuses and to evaluate their correlation with neonatal outcome. MATERIAL AND METHODS: An observational cohort study including singleton pregnancies referred to our tertiary care center due to fetal smallness. At the time of diagnosis, fetuses were classified as SGA or FGR according to the Delphi consensus criteria, and pregnant women underwent hemodynamic assessment using a cardiac output monitor. A group of women with singleton uncomplicated pregnancies ar ≥35 weeks of gestation were recruited as controls. Cardiac output, systemic vascular resistance, stroke volume, and heart rate were measured and compared among the three groups (controls vs FGR vs SGA). The correlation between antenatal findings and neonatal outcome was also evaluated by multivariate logistic regression analysis. RESULTS: A total of 51 women with fetal smallness were assessed at 34.8 ± 2.6 weeks. SGA and FGR were diagnosed in 22 and 29 cases, respectively. The control group included 61 women assessed at 36.5 ± 0.8 weeks of gestation. Women with FGR had a lower cardiac output Z-score (respectively, -1.3 ± 1.2 vs -0.4 ± 0.8 vs -0.2 ± 1.0; P < .001) and a higher systemic vascular resistance Z-score (respectively, 1.2 ± 1.2 vs 0.2 ± 1.1 vs -0.02 ± 1.2; P < .001) compared with both SGA and controls, whereas no difference in the hemodynamic parameters was found between women with SGA and controls. The incidence of neonatal intensive care unit admission did not differ between SGA and FGR fetuses (18.2% vs 41.4%; P = .13), but FGR fetuses had a longer hospitalization compared with SGA fetuses (14.2 ± 17.7 vs 4.5 ± 1.6 days; P = .02). Multivariate analysis showed that the cardiac output Z-score at diagnosis (P = .012) and the birthweight Z-score (P = .007) were independent predictors of the length of neonatal hospitalization. CONCLUSIONS: Different maternal hemodynamic profiles characterize women with SGA or FGR fetuses. Furthermore, a negative correlation was found between the maternal cardiac output and the length of neonatal hospitalization.


Assuntos
Desenvolvimento Fetal , Retardo do Crescimento Fetal/diagnóstico , Monitorização Hemodinâmica , Hemodinâmica/fisiologia , Recém-Nascido Pequeno para a Idade Gestacional , Gestantes , Adulto , Débito Cardíaco , Estudos de Coortes , Feminino , Frequência Cardíaca , Humanos , Recém-Nascido , Gravidez , Terceiro Trimestre da Gravidez/fisiologia , Volume Sistólico , Centros de Atenção Terciária , Resistência Vascular
4.
Clin Imaging ; 64: 53-56, 2020 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-32325262

RESUMO

PURPOSE: To evaluate by means of elastography if the quantitative assessment of the cesarean scar elasticity is feasible using as reference the surrounding intact myometrium and to investigate if the cesarean scar stiffness is influenced by the clinical characteristics of the previous cesarean delivery. METHODS: Prospective study including women with a previous Cesarean Section (CS) ≥ 37 weeks' gestation performed 12-15 months before. By transvaginal ultrasound two regions of interest (ROI) were selected: uterine scar (Region 1) and surrounding myometrium (Region 2). Strain index (SI) for each ROI was calculated and the Strain Ratio (SR) was defined as Region 1 SI/Region 2 SI. The primary outcome was to compare SR among women who were grouped in accordance to presence of previous vaginal delivery, CS during labor, type of suture or pyrexia during post-partum. The secondary outcome of this study was to evaluate the correlation between SR and maternal, neonatal and labor characteristics. RESULTS: 68 women were included. The mean SR was 1.8 ± 0.7 thus indicating an increased stiffness of the uterine scar compared to the surrounding myometrium. No significant differences were found in terms of SR according to presence of previous VD, CS during labor, type of suture or pyrexia during post-partum period. Strain Ratio was not correlated to maternal characteristics nor to labor and neonatal outcome. CONCLUSIONS: Evaluation of uterine scar stiffness is feasible by using elastography. The stiffness of the uterine scar is higher than that of the surrounding myometrium and is not correlated to maternal and labor characteristics.


Assuntos
Cicatriz/diagnóstico por imagem , Útero/diagnóstico por imagem , Adulto , Cesárea , Estudos de Coortes , Elasticidade , Técnicas de Imagem por Elasticidade , Feminino , Idade Gestacional , Humanos , Miométrio/patologia , Período Pós-Parto , Gravidez , Estudos Prospectivos , Suturas , Ultrassonografia
5.
Early Hum Dev ; 143: 104984, 2020 04.
Artigo em Inglês | MEDLINE | ID: mdl-32092675

RESUMO

BACKGROUND: A correlation between ACS and neonatal hypoglycemia has been recently demonstrated. AIMS: The aim of the study was to evaluate the determinants of neonatal hypoglycemia in women exposed to ACS for respiratory distress syndrome prevention. MATERIAL AND METHODS: Retrospective, multicenter, cohort study conducted in two Tertiary University Units. All fetuses delivered from 2016 to 2017 after ACS (two doses i.m. of Betamethasone 12 mg 24 h apart) were considered eligible for the study purpose. The primary outcome was the incidence of hypoglycemia, defined as a glycemic value ≤45 mg/dl within the first 48 h of neonatal life. The effect on neonatal glycaemia due to timing (interval from exposure to delivery) and type (single completed, single partial or repeated course) of ACS administration was also assessed. RESULTS: Overall, 99 neonates met the inclusion criteria. Hypoglycemia occurred in 38/99 (38.4%) of the included newborns. Compared to normoglycemic neonates, those with hypoglycemia had lower gestational age at delivery (33.06 ±â€¯3.37 vs. 35.94 ±â€¯3.17 g; p < 0.0001). Lower birthweight (1747.28 ±â€¯815.29 vs. 2499.24 ±â€¯780.51 g; p < 0.0001), a shorter interval time from administration to delivery (1.85 ±â€¯2.59 vs. 3.34 ±â€¯3.39 weeks; p = 0.02) and a higher incidence of single partial course (23.7 vs. 8.72%; p = 0.03). Multivariate logistic regression found that only birthweight was significantly associated with neonatal hypoglycemia (OR 0.4 95% CI -1.16/-0.04; p < 0.038). CONCLUSION: Hypoglycemia occurs in a large proportion of fetuses exposed to ACS independently from the type of exposure (single partial/single completed) and from the time interval between ACS administration and delivery. Birthweight seems to be the strongest determinant for the occurrence neonatal hypoglycemia after antenatal administration of steroids for lung maturation.


Assuntos
Corticosteroides/efeitos adversos , Hipoglicemia/epidemiologia , Doenças do Recém-Nascido/epidemiologia , Efeitos Tardios da Exposição Pré-Natal/epidemiologia , Corticosteroides/administração & dosagem , Corticosteroides/uso terapêutico , Adulto , Peso ao Nascer , Feminino , Humanos , Hipoglicemia/etiologia , Recém-Nascido , Doenças do Recém-Nascido/etiologia , Pulmão/embriologia , Masculino , Gravidez , Nascimento Prematuro/prevenção & controle , Efeitos Tardios da Exposição Pré-Natal/etiologia
6.
Am J Obstet Gynecol ; 221(6): 642.e1-642.e13, 2019 12.
Artigo em Inglês | MEDLINE | ID: mdl-31589867

RESUMO

BACKGROUND: A limited number of studies have addressed the role of intrapartum ultrasound in the prediction of the mode of delivery in women with prolonged second stage of labor. OBJECTIVE: The objective of the study was to evaluate the role of transabdominal and transperineal sonographic findings in the prediction of spontaneous vaginal delivery among nulliparous women with prolonged second stage of labor. STUDY DESIGN: This was a 2-center prospective study conducted at 2 tertiary maternity units. Nulliparous women with a prolonged active second stage of labor, as defined by active pushing lasting more than 120 minutes, were eligible for inclusion. Transabdominal ultrasound to evaluate the fetal head position and transperineal ultrasound for the measurement of the midline angle, the head-perineum distance, and the head-symphysis distance were performed in between uterine contractions and maternal pushes. At transperineal ultrasound the angle of progression was measured at rest and at the peak of maternal pushing effort. The delta angle of progression was defined as the difference between the angle of progression measured during active pushing at the peak of maternal effort and the angle of progression at rest. The sonographic findings of women who had spontaneous vaginal delivery vs those who required obstetric intervention, either vacuum extraction or cesarean delivery, were evaluated and compared. RESULTS: Overall, 109 were women included. Spontaneous vaginal delivery and obstetric intervention were recorded in 40 (36.7%) and 69 (63.3%) patients, respectively. Spontaneous vaginal delivery was associated with a higher rate of occiput anterior position (90% vs 53.2%, P < .0001), lower head-perineum distance and head-symphysis distance (33.2 ± 7.8 mm vs 40.1 ± 9.5 mm, P = .001, and 13.1 ± 4.6 mm vs 19.5 ± 8.4 mm, P < .001, respectively), narrower midline angle (29.6° ± 15.3° vs 54.2° ± 23.6°, P < .001) and wider angle of progression at the acme of the pushing effort (153.3° ± 19.8° vs 141.8° ± 25.7°, P = .02) and delta-angle of progression (17.3° ± 12.9° vs 12.5° ± 11.0°, P = .04). At logistic regression analysis, only the midline angle and the head-symphysis distance proved to be independent predictors of spontaneous vaginal delivery. More specifically, the area under the curve for the prediction of spontaneous vaginal delivery was 0.80, 95% confidence interval (0.69-0.92), P < .001, and 0.74, 95% confidence interval (0.65-0.83), P = .002, for the midline angle and for the head-symphysis distance, respectively. CONCLUSION: Transabdominal and transperineal intrapartum ultrasound parameters can predict the likelihood of spontaneous vaginal delivery in nulliparous women with prolonged second stage of labor.


Assuntos
Parto Obstétrico/métodos , Complicações do Trabalho de Parto/diagnóstico por imagem , Ultrassonografia Pré-Natal/métodos , Adulto , Feminino , Humanos , Apresentação no Trabalho de Parto , Segunda Fase do Trabalho de Parto , Gravidez , Estudos Prospectivos
7.
Am J Obstet Gynecol ; 221(6): 633.e1-633.e9, 2019 12.
Artigo em Inglês | MEDLINE | ID: mdl-31226294

RESUMO

BACKGROUND: A primary role of maternal heart dysfunction in the pathophysiology of preeclampsia had been previously advocated although if contradictory results have been reported. OBJECTIVES: The objectives of the study were to describe maternal hemodynamic parameters according to 2 main preeclampsia phenotypes and to investigate whether cardiac findings may be helpful in characterizing the severity and the progression of the disease. STUDY DESIGN: This was a prospective cohort study. We used an ultrasonic cardiac output monitor system to compare the hemodynamic parameters of women with preeclampsia with a group of healthy normotensive women enrolled as controls with a ratio of 1:2. Cardiac output, systemic vascular resistance, and stroke volume were compared among controls and preeclamptic women who were grouped in accordance to the following characteristics: early preeclampsia (<34 weeks' gestation) vs late preeclampsia onset (≥34 weeks' gestation); preeclampsia associated with appropriate for gestational age or small-for-gestational-age newborns. Hemodynamic characteristics were also compared between preeclamptic women with a mild form vs those who progressed toward a severe form. RESULTS: A total of 38 preeclamptic women and 61 normotensive women were included in the study. Both cases of preeclampsia associated with small-for-gestational-age neonates as those with normal-sized ones showed higher systemic vascular resistance compared with the control group (respectively, 1580.6 ± 483.2 vs 1479.1 ± 433.3 vs 1105.3 ± 293.1; P < .0001), while a lower cardiac output was reported only for preeclamptic women with small-for-gestational-age neonates compared with controls (5.7 ± 1.5 vs 6.5 ± 1.3; P = .02). Maternal cardiac parameters were comparable between these 2 groups of preeclamptic women (small-for-gestational-age vs appropriate-for-gestational-age preeclampsia) with the exception of a lower stroke volume in the former one (64.8 ± 24.4 vs 75.2 ± 17.8; P = .04). Similarly, women with both early and late preeclampsia showed higher systemic vascular resistance compared with controls (1559.5 ± 528.3 vs 1488.5 ± 292.9 vs 1105.3 ± 293.1, respectively; P < .001), while a lower cardiac output was noted only in the early-onset group compared with controls (5.5 ± 1.2 P = .02). Maternal cardiac findings were similar between women with early vs late-onset preeclampsia. Hemodynamic parameters are significantly different between those women with mild preeclampsia who remained stable compared with those who progressed toward a severe disease. Cardiac output Z-score, systemic vascular resistance Z-score, and uterine arteries' pulsatility index Z-score showed similar sensitivity (80% vs 75% vs 80%, respectively) and specificity (73% vs. 73% vs 74%, respectively), while the association of systemic vascular resistance Z-score and uterine arteries pulsatility index Z-score showed a sensitivity of 95% and a specificity of 80% (area under the curve, 0.90) in predicting evolution toward severe forms. CONCLUSION: Evaluation of maternal cardiovascular system could help clinician in defining a subset of preeclamptic patients with more profound placental impairment and might predict the likelihood of progression toward a severe condition in cases with a mild preeclampsia at clinical onset.


Assuntos
Progressão da Doença , Pré-Eclâmpsia/fisiopatologia , Índice de Gravidade de Doença , Adulto , Débito Cardíaco/fisiologia , Estudos de Casos e Controles , Estudos de Coortes , Feminino , Humanos , Recém-Nascido , Recém-Nascido Pequeno para a Idade Gestacional , Gravidez , Fluxo Pulsátil/fisiologia , Sensibilidade e Especificidade , Volume Sistólico/fisiologia , Ultrassonografia Doppler em Cores , Artéria Uterina/diagnóstico por imagem , Resistência Vascular/fisiologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA