Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
Vector Borne Zoonotic Dis ; 24(3): 177-180, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38032900

RESUMO

The tick-borne encephalitis (TBE) virus has been confirmed by molecular analysis in the Caucasus region for the first time. The virus obtained from a tick Ixodes ricinus ex Caspian green lizard belongs to the Zausaev strain of the Siberian subtype (not to a strain of the European subtype highly distributed in the territories adjacent to the Caucasus). This unusual record indicates the need to study the role of lizards in the circulation of natural focal infections.


Assuntos
Vírus da Encefalite Transmitidos por Carrapatos , Encefalite Transmitida por Carrapatos , Ixodes , Animais , Encefalite Transmitida por Carrapatos/epidemiologia , Encefalite Transmitida por Carrapatos/veterinária , Europa (Continente)/epidemiologia , Ásia , Federação Russa/epidemiologia
2.
Magn Reson Med ; 89(6): 2318-2331, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-36744719

RESUMO

PURPOSE: To demonstrate the feasibility of using octafluorocyclobutane (OFCB, c-C4 F8 ) for T1 mapping of lungs in 19 F MRI. METHODS: The study was performed at 7 T in three healthy rats and three rats with pulmonary hypertension. To increase the sensitivity of 19 F MRI, a bent-shaped RF coil with periodic metal strips structure was used. The double flip angle method was used to calculate normalized transmitting RF field (B1n + ) maps and for correcting T1 maps built with the variable flip angle (VFA) method. The ultrashort TE pulse sequence was applied for acquiring MR images throughout the study. RESULTS: The dependencies of OFCB relaxation times on its partial pressure in mixtures with oxygen, air, helium, and argon were obtained. T1 of OFCB linearly depended on its partial pressure with the slope of about 0.35 ms/kPa in the case of free diffusion. RF field inhomogeneity leads to distortion of T1 maps built with the VFA method, and therefore to high standard deviation of T1 in these maps. To improve the accuracy of the T1 maps, the B1n + maps were applied for VFA correction. This contributed to a 2-3-fold decrease in the SD of T1 values in the corresponding maps compared with T1 maps calculated without the correction. Three-dimensional T1 maps were obtained, and the mean T1 in healthy rat lungs was 35 ± 10 ms, and in rat lungs with pulmonary hypertension - 41 ± 9 ms. CONCLUSION: OFCB has a spin-rotational relaxation mechanism and can be used for 19 F T1 mapping of lungs. The calculated OFCB maps captured ventilation defects induced by edema.


Assuntos
Hipertensão Pulmonar , Ratos , Animais , Imageamento por Ressonância Magnética/métodos , Pulmão/diagnóstico por imagem , Imagens de Fantasmas
3.
J Vector Ecol ; 47(1): 19-28, 2022 03.
Artigo em Inglês | MEDLINE | ID: mdl-35366676

RESUMO

Rock lizards of the genus Darevskia are interesting research models due to their asexual reproduction. Ectoparasitic mites and ticks of these lizards are poorly known, despite some of these chelicerates being vector pathogens of humans and wildlife. Here we document and curate previously known data on ectoparasitic Acari of rock lizards and, based on our extensive survey, provide an annotated list of these ectoparasitic arthropods (six tick species, one macronyssid species, and seven chigger species). We also provide new host records (Ixodes ricinus on Darevskia caucasica, D. dryada, D. mixta, and D. szczerbaki; Haemaphysalis sulcata on D. rudis; Odontacarus saxicolis on D. brauneri); and new geographical records (O. saxicolis in Russia and Georgia).


Assuntos
Ixodes , Ixodidae , Lagartos , Ácaros , Animais , Lagartos/parasitologia
4.
J Magn Reson ; 339: 107216, 2022 06.
Artigo em Inglês | MEDLINE | ID: mdl-35413516

RESUMO

This work is dedicated to the development of a novel design for wireless transmission line resonators (TLRs). The TLRs are often considered as circular-shaped coils made up of two conductive circuits separated by a dielectric layer. We propose a square-shaped TLR design, wherein the coil has two square turns with two symmetrical gaps on each of the conductive layers, and the latter are rotated relative to each other by 90°. The calculation error of the resonant frequency of the square-shaped TLRs is no more than ∼3% of the measured value. The effectiveness of the square-shaped TLR design was evaluated in comparative 1H MRI studies to conventional wireless square loop of the same resonant frequency and with the same-sized inner square of the TLR. The Bruker birdcage was used as a transceiver and as inductively coupled with the wireless coils. We found that the performance of the square-shaped TLR and the square loop is comparable, but the B1+-field generated by the TLR has a wider distribution profile. It was reflected in rat brain studies, when some structures of rat head were not captured by the square loop. Comparative experiments with a standard circular-shaped TLR showed that a signal is predominantly concentrated inside the inner turn of the TLRs. The proposed TLR design can be a promising path to be explored, especially for scanning small objects of study, when the scan area is comparable to the size of the rigid lumped capacitors.


Assuntos
Imageamento por Ressonância Magnética , Animais , Desenho de Equipamento , Imagens de Fantasmas , Ratos
5.
Parasitol Int ; 85: 102429, 2021 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-34332073

RESUMO

The Caucasus is a large region in Eurasia consisting of four countries: Russia, Georgia, Azerbaijan, and Armenia. Although it is one of the biodiversity hotspots in the world, the bat ectoparasite fauna has been poorly studied. To promotionally fill in the gaps regarding bat ectoparasites, we conducted five field surveys on bats and their ectoparasites at nine localities within the region between April 2016 and March 2021. Eight species and subspecies of spinturnicid mites were recorded over the surveys: Eyndhovenia euryalis oudemansi, Spinturnix acuminata acuminata, S. emarginata, S. myoti, S. nobleti, S. plecotina, S. psi, and S. punctata. Among them, three species, Spinturnix emarginata, S. nobleti and S. punctate, are newly recorded from the Caucasus region, and one each of subspecies and species, Eyndhovenia euryalis oudemansi and S. plecotina, are newly recorded from Georgia. In addition, Myotis tschuliensis was recorded as a new host species of S. myoti.


Assuntos
Distribuição Animal , Quirópteros/parasitologia , Interações Hospedeiro-Parasita , Ácaros/fisiologia , Animais , Feminino , Georgia , Larva/crescimento & desenvolvimento , Larva/fisiologia , Masculino , Ácaros/crescimento & desenvolvimento , Ninfa/crescimento & desenvolvimento , Ninfa/fisiologia , Federação Russa
6.
Quant Imaging Med Surg ; 10(7): 1441-1449, 2020 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-32676363

RESUMO

Fast single-point macromolecular proton fraction (MPF) mapping is a recent magnetic resonance imaging (MRI) method enabling quantitative assessment of myelin content in neural tissues. To date, the reported technical implementations of MPF mapping utilized high-field MRI equipment (1.5 T or higher), while low-field applications might pose challenges due to signal-to-noise ratio (SNR) limitations and short T1 . This study aimed to evaluate the feasibility of MPF mapping of the human brain at 0.5 T. The three-dimensional MPF mapping protocol was implemented according to the single-point synthetic-reference method, which includes three spoiled gradient-echo sequences providing proton density, T1 , and magnetization transfer contrast weightings. Whole-brain MPF maps were obtained from three healthy volunteers with spatial resolution of 1.5×1.5×2 mm3 and the total scan time of 19 minutes. MPF values were measured in a series of white and gray matter structures and compared with literature data for 3 T magnetic field. MPF maps enabled high contrast between white and gray matter with notable insensitivity to paramagnetic effects in iron-rich structures, such as globus pallidus, substantia nigra, and dentate nucleus. MPF values at 0.5 T appeared in close agreement with those at 3 T. This study demonstrates the feasibility of fast MPF mapping with low-field MRI equipment and the independence of brain MPF values of magnetic field. The presented results confirm the utility of MPF as an absolute scale for MRI-based myelin content measurements across a wide range of magnetic field strengths and extend the applicability of fast MPF mapping to inexpensive low-field MRI hardware.

7.
Magn Reson Med ; 84(4): 2117-2123, 2020 10.
Artigo em Inglês | MEDLINE | ID: mdl-32274848

RESUMO

PURPOSE: The aim of this study was to demonstrate the feasibility of fluorine-19 (19 F) MRI of the human lungs using octafluorocyclobutane (OFCB, C4 F8 ). This gas has 8 magnetically equivalent fluorine nuclei and relatively long T1 and T2 (˜50 ms), which render it suitable as an MRI contrast agent. Previous experiments in small laboratory animals showed that OFCB could be successfully used as an alternative to the gases often used for 19 F MRI (sulfur hexafluoride and perfluoropropane). METHODS: One male volunteer participated in this study. Immediately before an MRI scan, the volunteer inhaled the gas mixture-80% OFCB with 20% oxygen-and held his breath. Experiments were performed on a 0.5T whole-body MR scanner with a customized transmit-receive coil tuned at 19 F frequency. Fast spin echo in 2D and 3D modes was used for image acquisition. 2D images were obtained with in-plane resolution of 10 × 10 mm2 without slice selection. 3D images were obtained with the voxel size of 10 × 10 × 30 mm2 . Breath-hold duration was 20 s for 2D and 40 s for 3D imaging, respectively. RESULTS: Anatomically consistent 19 F MR images of the human lungs were obtained with SNR around 50 in 2D mode and 20 in 3D mode. 3D volumetric images of the lungs were reconstructed and provided physiologically reasonable volume estimates. CONCLUSION: The application of OFCB enables informative 19 F lung imaging even at low magnetic field strengths. The OFCB gas shows promise as an inhalable contrast agent for fluorine lung MRI and has a potential for clinical translation.


Assuntos
Pulmão , Imageamento por Ressonância Magnética , Animais , Clorofluorcarbonetos , Meios de Contraste , Humanos , Imageamento Tridimensional , Pulmão/diagnóstico por imagem , Masculino
8.
J Magn Reson ; 309: 106626, 2019 12.
Artigo em Inglês | MEDLINE | ID: mdl-31678914

RESUMO

This study shows how a copper plate could be used for frequency tuning of surface wired and wireless MRI coils. For this purpose, it is proposed to place the copper plate directly on their conducting circuit. This leads to increase in the resonance frequency of coils. The effect is most perceptible if the copper plate is comparable in size to the conducting circuit of radiofrequency (RF) coil. The experimental work was performed on a 7.05 T MR scanner using surface MRI coils operating on different resonance frequencies: 1H (300 MHz), 31P (121 MHz), 23Na (79 MHz), 13C (75 MHz). Application of copper plate for frequency tuning of wireless multi-turn multi-gap transmission line resonator (MTMG-TLR) was considered for the first time. The proposed method can be claimed if the nominal variable inductance or capacitance is not enough for tuning the resonance frequency of the MRI coil to a higher frequency range.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA