Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 13 de 13
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
Clin Biochem ; 118: 110598, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-37330000

RESUMO

OBJECTIVES: Human thyroglobulin (Tg) is widely used as a tumor marker for recurrence and metastasis of differentiated thyroid cancer (DTC). Currently, serum Tg values are measured using second-generation sandwich immunoassays (2nd-IMA). However, interference by endogenous autoantibodies to thyroglobulin (TgAbs) can lead to false-negative results or falsely low Tg values. Here, we describe a new Tg assay using the immunoassay for total antigen including complex via pretreatment (iTACT) method to prevent TgAb interference and compare it with 2nd-IMA. METHODS: Tg values were evaluated by three assays: iTACT Tg, Elecsys Tg-II, which is a 2nd-IMA, and LC-MS/MS (Liquid chromatography tandem-mass spectrometry). The ratio of Tg values between each assay was then compared to the Tg value by LC-MS/MS and TgAb titer. Tg immunoreactivity was analyzed by size-exclusion chromatography. RESULTS: Correlation between iTACT Tg and LC-MS/MS using TgAb-positive specimens was good: Passing-Bablok regression with iTACT Tg = 1.084 × LC-MS/MS + 0.831. Correlation between 2nd-IMA and LC-MS/MS showed a relatively lower slope: 2nd-IMA = 0.747 × LC-MS/MS - 0.518. Thus, Tg values determined by iTACT Tg are equivalent to those of LC-MS/MS regardless of TgAb titer, whereas 2nd-IMA gave lower Tg values due to TgAb interference. Tg-TgAb complexes of various molecular weights were verified by size-exclusion chromatography. Tg values measured by 2nd-IMA fluctuated depending on the molecular weight of the Tg-TgAb complexes, whereas iTACT Tg accurately quantified Tg values regardless of the size of the Tg-TgAb complexes. CONCLUSION: Tg values in TgAb-positive specimens were accurately determined by iTACT Tg. TgAb-positive specimens contain Tg-TgAb complexes of various molecular weights that interfere with Tg value determination by 2nd-IMA, whereas iTACT Tg is unaffected by the presence of Tg-TgAb complexes.


Assuntos
Espectrometria de Massas em Tandem , Neoplasias da Glândula Tireoide , Humanos , Radioimunoensaio/métodos , Cromatografia Líquida , Autoanticorpos , Imunoensaio , Neoplasias da Glândula Tireoide/diagnóstico
3.
Ann Clin Transl Neurol ; 9(12): 1898-1909, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-36321325

RESUMO

OBJECTIVES: Cerebrospinal fluid (CSF) biomarkers of Alzheimer's disease (AD) are well-established in research settings, but their use in routine clinical practice remains a largely unexploited potential. Here, we examined the relationship between CSF biomarkers, measured by a fully automated immunoassay platform, and brain ß-amyloid (Aß) deposition status confirmed by amyloid positron emission tomography (PET). METHODS: One hundred ninety-nine CSF samples from clinically diagnosed AD patients enrolled in a clinical study and who underwent amyloid PET were used for the measurement of CSF biomarkers Aß 1-40 (Aß40), Aß 1-42 (Aß42), total tau (t-Tau), and phosphorylated tau-181 (p-Tau181) using the LUMIPULSE system. These biomarkers and their combinations were compared to amyloid PET classification (negative or positive) using visual read assessments. Several combinations were also analyzed with a multivariable logistic regression model. RESULTS: Aß42, t-Tau, and p-Tau181, and the ratios of Aß42 with other biomarkers had a good diagnostic agreement with amyloid PET imaging. The multivariable logistic regression analysis showed that amyloid PET status was associated with Aß40 and Aß42, but other factors, such as MMSE, sex, t-Tau, and p-Tau181, did not significantly add information to the model. CONCLUSIONS: CSF biomarkers measured with the LUMIPULSE system showed good agreement with amyloid PET imaging. The ratio of Aß42 with the other analyzed biomarkers showed a higher correlation with amyloid PET than Aß42 alone, suggesting that the combinations of biomarkers could be useful in the diagnostic assessment in clinical research and potentially in routine clinical practice.


Assuntos
Doença de Alzheimer , Humanos , Doença de Alzheimer/diagnóstico por imagem , Doença de Alzheimer/líquido cefalorraquidiano , Amiloide/metabolismo , Biomarcadores/líquido cefalorraquidiano , Tomografia por Emissão de Pósitrons , Encéfalo/metabolismo
4.
J Gastroenterol ; 57(7): 486-494, 2022 07.
Artigo em Inglês | MEDLINE | ID: mdl-35478052

RESUMO

BACKGROUNDS: A fully automated, novel, high-sensitivity hepatitis B core-related antigen assay (iTACT-HBcrAg) has been developing. The purpose of this study is to evaluate the efficacy of measuring HBcrAg, using that assay, to diagnose HBV reactivation in a multi-center setting, compared with ultra-high-sensitivity HBsAg (iTACT-HBsAg) and HBV DNA assays. METHODS: Forty-four patients with HBV reactivation from 2008 to 2020 were enrolled in four hospitals. Serial serum specimens from the patients were assessed retrospectively for their HBcrAg levels by iTACT-HBcrAg (lower limit of detection; 2.0 log U/mL) and HBsAg levels by iTACT-HBsAg (lower limit of detection; 0.0005 IU/mL); these were compared to the HBV DNA levels. HBV reactivation was defined as detection of serum HBV DNA, including unquantifiable detection. RESULTS: At HBV reactivation and/or thereafter, HBV DNA levels were quantified (≥ 1.3 log IU/mL) in the sera of 27 patients, and were below the level of quantification (< 1.3 log IU/mL) in the sera of 17 patients. Of the 27 patients with HBV reactivation and whose serum HBV DNA was quantified, the sera of 26 and 24 patients (96.3% and 88.9%) were positive by iTACT-HBcrAg and iTACT-HBsAg, respectively. HBcrAg was detectable by iTACT-HBcrAg before HBV DNA was quantifiable in 15 of the 27 patients. Of the 11 patients with HBV reactivation and undetectable HBcrAg by iTACT-HBcrAg at HBV reactivation and/or thereafter, 10 had unquantifiable HBV DNA and none developed HBV reactivation-related hepatitis. CONCLUSIONS: The iTACT-HBcrAg assay is useful for monitoring HBV reactivation to determine the initiation of treatment with nucleos(t)ide analogues.


Assuntos
Antígenos do Núcleo do Vírus da Hepatite B , Hepatite B Crônica , Biomarcadores , DNA Viral , Antígenos de Superfície da Hepatite B , Vírus da Hepatite B/genética , Hepatite B Crônica/tratamento farmacológico , Humanos , Estudos Retrospectivos
5.
Hepatol Res ; 52(9): 745-753, 2022 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-35199427

RESUMO

AIMS: To prevent hepatitis B virus (HBV) reactivation-related hepatitis, we examined the clinical usefulness of a highly sensitive HB core-related antigen (iTACT-HBcrAg) assay in patients with resolved HBV infection after nucleos(t)ide analog (NA) treatment for HBV reactivation. METHODS: We retrospectively analyzed 27 patients with resolved HBV infection who experienced HBV reactivation (defined as HBV DNA levels of 1.3 log IU/ml or more), and who received systemic chemotherapies for hematological malignancies between 2008 and 2020. iTACT-HBcrAg, HBsAg-HQ, and antibodies against hepatitis B surface antigen (anti-HBs) were measured using samples stored after HBV reactivation. The lower limit of quantification for iTACT-HBcrAg was 2.0 log U/ml. RESULTS: HBV reactivation was diagnosed at a median HBV DNA level of 1.8 log IU/ml, and then all patients received NA treatment. No patient had HBV-related hepatitis with a median maximum HBV DNA level of 2.0 log IU/ml. The positivities of iTACT-HBcrAg and HBsAg-HQ were 96% and 52% after HBV reactivation, respectively. Of 25 patients with detectable iTACT-HBcrAg at the initiation of NA treatment, 17 (68%) achieved iTACT-HBcrAg loss. Median durations from NA treatment to HBV DNA loss and iTACT-HBcrAg loss or the last follow-up were 35 and 175 days, respectively. Recurrence of HBV reactivation after NA cessation was not observed in seven of eight patients who achieved iTACT-HBcrAg loss or seropositive for anti-HBs during follow-up, except for one without anti-HBs after allogeneic transplantation. CONCLUSIONS: iTACT-HBcrAg could be a potential surrogate marker for diagnosing early-stage HBV reactivation as well as safe cessation of NA treatment in patients with resolved HBV infection after HBV reactivation.

6.
J Appl Lab Med ; 6(6): 1463-1475, 2021 11 01.
Artigo em Inglês | MEDLINE | ID: mdl-34580727

RESUMO

BACKGROUND: Recently, second-generation thyroglobulin (Tg) sandwich immunoassays have been used in clinical laboratories to measure the serum Tg levels, which is a tumor marker used to monitor postoperative patients with differentiated thyroid cancers. However, these immunoassays are often subject to Tg autoantibody (TgAb) interference. TgAb interference is inevitable for almost all Tg immunoassays, resulting in unreliable Tg measurement values of TgAb-positive samples. METHODS: To address TgAb interference, we have developed a novel immunoassay based on a fully automated chemiluminescent enzyme immunoassay system using the effective specimen-pretreatment process to inactivate TgAb in blood and evaluated its assay performance. RESULTS: The developed assay was traceable to BCR457 IRMM reference material with a limit of quantification of 0.03 ng/mL. The pretreatment process inactivated almost all TgAb in specimens and allowed accurate Tg measurements in TgAb-positive samples in which TgAb interference was observed using the immunoassays. Size-exclusion chromatography analysis of immunoreactive Tg molecule in a TgAb-positive serum verified disruption of the Tg-TgAb immune complex by the pretreatment process. Good correlation of Tg values in TgAb-negative specimens was observed between the new Tg immunoassay and the second-generation sandwich immunoassays. However, there were numerous discrepant samples on bias plots between the new Tg immunoassay and the second-generation sandwich immunoassays for TgAb-positive specimens. CONCLUSIONS: This study indicates the new Tg immunoassay with the specimen-pretreatment process is both robust and free from interference by TgAb. Thus, this novel assay is superior to second-generation sandwich immunoassays and gives accurate Tg concentrations even for TgAb-positive cases.


Assuntos
Tireoglobulina , Neoplasias da Glândula Tireoide , Autoanticorpos , Humanos , Imunoensaio , Neoplasias da Glândula Tireoide/diagnóstico
7.
J Hepatol ; 75(2): 302-310, 2021 08.
Artigo em Inglês | MEDLINE | ID: mdl-33762167

RESUMO

BACKGROUND & AIMS: A fully automated, novel high-sensitivity hepatitis B core-related antigen assay (iTACT-HBcrAg) has been developed. We demonstrate the clinical utility of iTACT-HBcrAg for monitoring chronic hepatitis B (CHB) and for the early detection of HBV reactivation. METHODS: After fundamental assessments, the clinical performance of iTACT-HBcrAg was compared with other HBV markers. i) Serial sera, available from 161 HBeAg-negative patients with CHB and persistently undetectable HBV DNA, were measured by iTACT-HBcrAg and a conventional HBcrAg assay (G-HBcrAg). ii) Serial sera from 13 HBV-reactivated patients were measured by iTACT-HBcrAg and an ultra-high-sensitivity HBsAg immune complex transfer-chemiluminescent enzyme immunoassay (lower limit of detection; 0.0005 IU/ml, ICT-CLEIA) to compare HBV DNA detection. iii) To elucidate the various HBcrAg components detected by iTACT-HBcrAg, OptiPrep density gradient centrifugation analysis was performed on sera obtained before and after HBV reactivation. RESULTS: The analytical performance of iTACT-HBcrAg was satisfactory. The sensitivity of iTACT-HBcrAg (2.1 Log U/ml) was approximately 10-fold greater than that of G-HBcrAg (2.8 Log U/ml). i) HBcrAg was detectable in the sera of 97.5% (157/161) of patients with CHB by iTACT-HBcrAg, of whom 75.2% (121/161) had ≥2.8 Log U/ml HBcrAg and 22.4% (36/161) had 2.1-2.8 Log U/ml HBcrAg, which was undetectable by G-HBcrAg. ii) 9 and 2 of 13 HBV-reactivated patients were HBcrAg-positive by iTACT-HBcrAg before and at HBV DNA positivity, respectively; 7 and 4 were HBcrAg-positive by iTACT-HBcrAg before and at HBsAg-positivity by ICT-CLEIA, respectively. iii) The HBcrAg detected by iTACT-HBcrAg before HBV reactivation was contained in empty particles (22 KDa precore protein). CONCLUSIONS: iTACT-HBcrAg could be used to better monitor responses to anti-HBV treatments in HBeAg-negative patients and for the early detection of HBV reactivation. LAY SUMMARY: A fully automated, novel high-sensitivity hepatitis B core-related antigen assay (iTACT-HBcrAg) has been developed. iTACT-HBcrAg can be used to monitor HBeAg-negative patients with chronic hepatitis B, as well as for the early detection of HBV reactivation. iTACT-HBcrAg could be used as a general marker of disease progression and treatment response.


Assuntos
Anticorpos Anti-Hepatite B/análise , Hepatite B Crônica/sangue , Infecção Latente/sangue , Resultado do Tratamento , Adulto , Biomarcadores/análise , Biomarcadores/sangue , Progressão da Doença , Feminino , Anticorpos Anti-Hepatite B/sangue , Hepatite B Crônica/diagnóstico , Humanos , Japão , Infecção Latente/diagnóstico , Masculino , Pessoa de Meia-Idade
8.
J Infect Chemother ; 27(2): 384-386, 2021 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-33397587

RESUMO

We evaluated the rapid immunochromatographic test for severe acute respiratory coronavirus 2 (SARS-CoV-2) antigen detection using 16 saliva specimens collected from 6 COVID-19 hospitalized patients, and detected N-antigen in 4 of 7 RT-PCR positive specimens. This POCT detected SARS-CoV-2 antigen in saliva and would be useful for COVID-19 diagnosis.


Assuntos
Antígenos Virais/análise , Teste Sorológico para COVID-19/métodos , COVID-19/diagnóstico , SARS-CoV-2/imunologia , Saliva/virologia , Humanos , Testes Imunológicos , Nasofaringe/virologia , Testes Imediatos , RNA Viral/análise , Reação em Cadeia da Polimerase Via Transcriptase Reversa/métodos , SARS-CoV-2/isolamento & purificação , Sensibilidade e Especificidade
9.
Hepatol Res ; 51(3): 263-276, 2021 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-33350036

RESUMO

AIM: Type IV collagen 7S (T4C7S) is a valuable biomarker for detecting liver fibrosis in patients with nonalcoholic fatty liver disease (NAFLD). The conventional T4C7S measurement via radioimmunoassay (T4C7S RIA) has shortcomings of radioisotope usage and longer assay periods. We compared T4C7S RIA with a newly developed, fast T4C7S chemiluminescent enzyme immunoassay (T4C7S CLEIA) and examined the diagnostic accuracies of and correlation between the two techniques. METHODS: We evaluated 170 biopsy-confirmed patients with NAFLD. T4C7S was measured via both T4C7S RIA and T4C7S CLEIA. The correlation between T4C7S RIA and T4C7S CLEIA was analyzed in 305 total serum samples via exploratory research and 47 validation samples. The diagnostic accuracies of T4C7S CLEIA and T4C7S RIA were compared in the sera of patients with NAFLD and test samples. RESULTS: Sera T4C7S levels of T4C7S CLEIA and T4C7S RIA significantly correlated in patients' samples via exploratory (r = 0.914, P = 0.000) and validation (r = 0.929, P = 0.000) research. At a 10% coefficient, T4C7S CLEIA concentration was 0.26 ng/ml in the serum samples, indicating high accuracy at even low concentrations. T4C7S CLEIA revealed distinct changes between each stage and high sensitivity in detecting the F2 stage, indicating a higher sensitivity in detecting low fibrosis stages than T4C7S RIA in patients with NAFLD. CONCLUSIONS: The T4C7S CLEIA correlated well with the T4C7S RIA. Favorably, the T4C7S CLEIA has a higher sensitivity and rapid measurement time and requires a small sample volume; thus, it is a promising and popular biomarker for fibrosis stage diagnosis in NAFLD.

10.
Clin Infect Dis ; 70(7): 1442-1452, 2020 03 17.
Artigo em Inglês | MEDLINE | ID: mdl-31102406

RESUMO

BACKGROUND: To eliminate hepatitis B virus (HBV) infection, it is essential to scale up testing and treatment. However, conventional tools to assess treatment eligibility, particularly nucleic acid testing (NAT) to quantify HBV DNA, are hardly available and affordable in resource-limited countries. We therefore assessed the performance of a novel immunoassay, hepatitis B core-related antigen (HBcrAg), as an inexpensive (US$ <15/assay) alternative to NAT to diagnose clinically important HBV DNA thresholds (≥2000, ≥20 000, and ≥200 000 IU/mL) and to select patients for antiviral therapy in Africa. METHODS: Using a well-characterized cohort of treatment-naive patients with chronic HBV infection in The Gambia, we evaluated the accuracy of serum HBcrAg to diagnose HBV DNA levels and to indicate treatment eligibility determined by the American Association for the Study of Liver Diseases, based on reference tests (HBV DNA, hepatitis B e antigen, alanine aminotransferase, liver histopathology, and/or FibroScan). RESULTS: A total of 284 treatment-naive patients were included in the analysis. The area under the receiver operating characteristic curve (AUROC), sensitivity, and specificity of serum HBcrAg were 0.88 (95% confidence interval [CI], .82-.93), 83.3%, and 83.9%, respectively, to diagnose HBV DNA ≥2000 IU/mL; and 0.94 (95% CI, .88-.99), 91.4%, and 93.2% for ≥200 000 IU/mL. A simplified treatment algorithm using HBcrAg without HBV DNA showed high AUROC (0.91 [95% CI, .88-.95]) with a sensitivity of 96.6% and specificity of 85.8%. CONCLUSIONS: HBcrAg might be an accurate alternative to HBV DNA quantification as a simple and inexpensive tool to identify HBV-infected patients in need of antiviral therapy in low- and middle-income countries.


Assuntos
Hepatite B Crônica , Hepatite B , África , DNA Viral , Gâmbia , Antígenos do Núcleo do Vírus da Hepatite B , Antígenos de Superfície da Hepatite B , Vírus da Hepatite B/genética , Hepatite B Crônica/diagnóstico , Hepatite B Crônica/tratamento farmacológico , Humanos
11.
Hepatol Res ; 48(13): 1081-1091, 2018 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-30006955

RESUMO

AIM: Recently, the measurement of hepatitis B surface antigen and anti-hepatitis B core antigen (HBcAb) and/or anti-hepatitis B surface antigen has been recommended before various therapies to identify patients at risk of hepatitis B virus (HBV) reactivation. However, a recent study reported that HBV reactivation occurred in HBcAb-negative patients, indicating that it is challenging to identify patients with a history of HBV infection using conventional HBcAb reagent. We developed a highly sensitive HBcAb (HBcAb-HS) assay for reducing the risk of HBV reactivation. METHODS: The HBcAb-HS assay is an automated chemiluminescent enzyme immunoassay system, which is suitable for clinical use. The cut-off was set at 0.020 IU/mL from the distribution patterns of HBcAb-negative specimens, and we evaluated the performance of this assay compared with conventional reagents. RESULTS: This new assay showed a 27-81-fold greater sensitivity than conventional HBcAb reagents; the quantified measurement range was from 0.005 IU/mL to 1.500 IU/mL, and it showed excellent quantitative performance and correlated well with two conventional assays, using the HBcAb-positive specimens. Moreover, it showed 100% specificity for the 469 purchased HBcAb-negative specimens. Notably, this newly developed HBcAb-HS assay showed positivity in the preserved specimens before HBV reactivation, for which conventional HBcAb reagents gave negative results, and the HBcAb-HS assay could detect the lower HBcAb levels even after intensive immunosuppressive therapies, including autologous hematopoietic stem cell transplantation. CONCLUSIONS: The clinical efficacy of the newly developed, highly sensitive HBcAb assay would enable the identification of patients at risk of HBV reactivation more accurately.

12.
J Gastroenterol ; 52(3): 376-384, 2017 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-27460099

RESUMO

BACKGROUND: Hepatitis B surface antigen (HBsAg) is used as a clinical marker of hepatitis B virus (HBV) infection. However, conventional HBsAg assays have so far failed to accurately detect HBsAg in blood because of interference by patient-derived antibodies against HBsAg (HBsAb). METHODS: We developed a novel, fully automated assay system that can detect total HBsAg in blood, including antigens complexed with HBsAb. The immunoassay inactivates HBsAb via a simple pretreatment step to dissociate the HBsAg molecule from HBsAg-HBsAb complexes and thereby estimate total HBsAg. Accordingly, the test has been termed the "immunoassay for total antigen including complex via pretreatment (iTACT)-HBsAg." RESULTS: The recovery rate of HBsAg in the presence of HBsAb was greater than 87 % at a cutoff value set at 5.0 mIU/mL on the basis of data from 545 healthy controls. Analyses using serial serum samples from 25 HBV carriers who became negative for HBsAg during follow-up showed that the iTACT-HBsAg could detect HBsAg over a period of years despite a loss in detection by conventional assays and was able to detect HBsAg in 39 (53 %) of 73 samples with HBsAb. CONCLUSIONS: The new iTACT-HBsAg assay appears to detect total HBsAg with high sensitivity, even in the presence of HBsAb, and may useful in identifying subclinical or occult HBV carriers.


Assuntos
Complexo Antígeno-Anticorpo/sangue , Anticorpos Anti-Hepatite B/sangue , Antígenos de Superfície da Hepatite B/sangue , Hepatite B/diagnóstico , Técnicas Imunoenzimáticas/métodos , Adulto , Idoso , Biomarcadores/sangue , Portador Sadio/diagnóstico , Cromatografia em Gel/métodos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Sensibilidade e Especificidade , Manejo de Espécimes/métodos
13.
Clin Chem ; 61(4): 627-35, 2015 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-25695852

RESUMO

BACKGROUND: Small molecules classified as haptens are generally measured by competitive immunoassay, which is theoretically inferior to noncompetitive sandwich immunoassay in terms of sensitivity and specificity. We created a method for developing sandwich immunoassays to measure haptens on the basis of antimetatype antibodies. METHODS: We generated antimetatype monoclonal antibodies against a hapten-antibody immunocomplex using an ex vivo antibody development system, the Autonomously Diversifying Library (ADLib) system. We selected 2 haptens, estradiol (E2) and 25-hydroxyvitamin D [25(OH)D], as analytes. Sandwich immunoassays for these 2 haptens were developed by use of a 96-well microtiter plate and a fully automated chemiluminescence analyzer, and the performances of these immunoassays were investigated. RESULTS: The developed assays exhibited sensitivity high enough to detect target haptens in serum samples. The limit of detection of the ELISA for E2 was 3.13 pg/mL, and that of the fully automated chemiluminescent enzyme immunoassay (CLEIA) system was 2.1 ng/mL for 25(OH)D. The cross-reactivity with immunoreactive derivatives was effectively improved compared with the competitive assay. The CVs for the sandwich ELISA for E2 were 4.2%-12.6% (intraassay) and 6.2%-21.8% (total imprecision). The CVs for the sandwich CLEIA for 25(OH)D were 1.0%-2.3% (intraassay) and 1.9%-3.5% (total imprecision). In particular, the sandwich CLEIA for 25(OH)D showed correlations of r = 0.99 with both LC-MS/MS and a commercially available (125)I RIA. CONCLUSIONS: Our method represents a potentially simple and practical approach for routine assays of haptens, including vitamins, hormones, drugs, and toxins.


Assuntos
Anticorpos Monoclonais , Estradiol/sangue , Haptenos/sangue , Imunoensaio/métodos , Vitamina D/análogos & derivados , Humanos , Imunoensaio/normas , Limite de Detecção , Sensibilidade e Especificidade , Vitamina D/sangue
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA