Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
J Anal Toxicol ; 2024 May 29.
Artigo em Inglês | MEDLINE | ID: mdl-38832557

RESUMO

Public laboratories must balance innovative and existing methods to keep up with designer drug trends. This article presents a strategy for handling designer benzodiazepines (DBZDs) in casework from screening to interpretation. The cross-reactivity of 22 DBZDs and metabolites was tested against the Immunalysis™ Benzodiazepine Direct Enzyme-Linked Immunosorbent Assay kit. The kit had high intra-analyte precision (coefficients of variation < 15%). Inter-analyte performance varied, triggering confirmation testing at concentrations ranging from 35 to 460 µg/L. The CCRFSL implemented a 40-analyte benzodiazepine and Z-drug confirmation method in 2019. Ten additional analytes were later validated for qualitative reporting, and the limits of detection (LODs) for 13 analytes were lowered by 60%. The method of standard addition was also optimized for as-needed quantitation. Equal and 1/x weighting factors correlated well with target concentrations (coefficients of determination (r2) > 0.98), but 1/x weighting provided the most consistently accurate concentrations. Six computational models were developed to predict DBZD binding affinity to the γ-aminobutyric acid-A receptor to assist in case interpretation (r2 > 0.7 for cross-validation and test set prediction). These models were used to predict the binding affinity of analytes in the confirmation method. Other public laboratories can use this same practical strategy to adapt to any designer drug class (e.g., benzodiazepines, opioids, cannabinoids, and stimulants).

2.
J Anal Toxicol ; 44(7): 708-717, 2020 Oct 12.
Artigo em Inglês | MEDLINE | ID: mdl-32808043

RESUMO

An analytical method for the detection of 40 benzodiazepines, (±)-zopiclone, zaleplon and zolpidem in blood and urine by solid-phase extraction liquid chromatography-tandem mass spectrometry was developed and validated. Twenty-nine of 43 analytes were quantified in 0.5 mL whole blood for investigating postmortem, drug-facilitated sexual assault (DFSA) and driving under the influence of drugs cases (DUID). The four different dynamic ranges of the seven-point, linear, 1/x weighted calibration curves with lower limits of quantification of 2, 5, 10 and 20 µg/L across the analytes encompassed the majority of our casework encountered in postmortem, DFSA and DUID samples. Reference materials were available for all analytes except α-hydroxyflualprazolam, a hydroxylated metabolite of flualprazolam. The fragmentation of α-hydroxyflualprazolam was predicted from the fragmentation pattern of α-hydroxyalprazolam, and the appropriate transitions were added to the method to enable monitoring for this analyte. Urine samples were hydrolyzed at 55°C for 30 min with a genetically modified ß-glucuronidase enzyme, which resulted in >95% efficiency measured by oxazepam glucuronide. Extensive sample preparation included combining osmotic lysing and protein precipitation with methanol/acetonitrile mixture followed by freezing and centrifugation resulted in exceptionally high signal-to-noise ratios. Bias and between-and within-day imprecision for quality controls (QCs) were all within ±15%, except for clonazolam and etizolam that were within ±20%. All 29 of the 43 analytes tested for QC performance met quantitative reporting criteria within the dynamic ranges of the calibration curves, and 14 analytes, present only in the calibrator solution, were qualitatively reported. Twenty-five analytes met all quantitative reporting criteria including dilution integrity. The ability to analyze quantitative blood and qualitative urine samples in the same batch is one of the most useful elements of this procedure. This sensitive, specific and robust analytical method was routinely employed in the analysis of >300 samples in our laboratory over the last 6 months.


Assuntos
Benzodiazepinas/metabolismo , Hipnóticos e Sedativos/metabolismo , Detecção do Abuso de Substâncias/métodos , Alprazolam/análogos & derivados , Compostos Azabicíclicos/sangue , Compostos Azabicíclicos/metabolismo , Compostos Azabicíclicos/urina , Benzodiazepinas/sangue , Benzodiazepinas/urina , Cromatografia Líquida/métodos , Diazepam/análogos & derivados , Toxicologia Forense , Humanos , Hipnóticos e Sedativos/análise , Hipnóticos e Sedativos/sangue , Hipnóticos e Sedativos/urina , Limite de Detecção , Piperazinas/sangue , Piperazinas/metabolismo , Piperazinas/urina , Medicamentos Indutores do Sono/sangue , Medicamentos Indutores do Sono/metabolismo , Medicamentos Indutores do Sono/urina , Extração em Fase Sólida/métodos , Espectrometria de Massas em Tandem/métodos , Zolpidem/sangue , Zolpidem/metabolismo , Zolpidem/urina
3.
J Anal Toxicol ; 43(9): 673-687, 2019 Oct 17.
Artigo em Inglês | MEDLINE | ID: mdl-31504606

RESUMO

The presented analytical method enabled the Toxicology Department at the Cuyahoga County Medical Examiner's Office to identify 26 and quantitatively report 24 compounds in 500 µL of whole blood, including fentanyl analogues (fentalogues) such as methoxyacetyl fentanyl (MeOAF) and cyclopropyl fentanyl (CPF). This second-generation method (FG2) was developed with the objective to improve the existing analysis (FG1) by decreasing sample size, lowering limits of detection (LOD) and lower limit of quantitation, minimizing ion suppression and resolving chromatographic interferences. Interferences may occur in the analysis of fentanyl, MeOAF, CPF, 3-methylfentanyl (3MF), butyryl fentanyl and isobutyryl fentanyl due to isobars and structural or geometric isomerism with another analogue or metabolite. The isomeric and isobaric fentalogues were grouped into three sets. The LOD established for Set 1 [MeOAF, para-methoxyacetyl fentanyl, para-fluoro acryl fentanyl (isobar), fentanyl carbamate], 2-furanyl fentanyl, Set 2 [CPF, (E)-crotonyl fentanyl] and carfentanil was 0.0125 ng/mL. The LOD established for N-methyl norfentanyl, norfentanyl, norcarfentanil, despropionyl fentanyl (4-ANPP), acetyl fentanyl, ß-hydroxy fentanyl, benzyl fentanyl, acryl fentanyl, alfentanil, fentanyl, para-fluoro fentanyl, Set 3 [(±)-trans-3MF, (±)-cis-3MF, isobutyryl and butyryl fentanyl], para-fluoroisobutyryl fentanyl, sufentanil, phenyl fentanyl and cyclopentenyl fentanyl was 0.0625 ng/mL. Seven-point linear calibration curves were established between 0.025 and 4.0 ng/mL for the 8 analytes with the lower LOD and 0.125 and 20 ng/mL for the 18 analytes with the higher LOD. 4-ANPP and cyclopentenyl fentanyl met qualitative reporting criteria only. The results for five postmortem and two driving under the influence of drugs authentic case samples are presented. To the authors' knowledge, FG2 is the first published method that achieved baseline resolution of the nine structural/stereo isomers and one isobar by ultra-high performance liquid chromatography-MS-MS and provided quantitative validation data for nine compounds. FG2 may be used as the new baseline for future isomers that need to be chromatographically separated.


Assuntos
Analgésicos Opioides/sangue , Fentanila/sangue , Autopsia , Cromatografia Líquida de Alta Pressão , Fentanila/análogos & derivados , Humanos , Isomerismo , Limite de Detecção , Espectrometria de Massas em Tandem
4.
J Anal Toxicol ; 31(4): 208-13, 2007 May.
Artigo em Inglês | MEDLINE | ID: mdl-17555644

RESUMO

The aim of this study was to evaluate the Bio-Quant Direct ELISA assays for amphetamine and methamphetamine in the routine presumptive screening of biological fluids. Standard concentration curves of the target analytes were assayed to assess sensitivity, and known concentrations of common amphetamine-type substances (ephedrine, pseudoephedrine, phentermine), designer analogues (MDA, MDMA, MDEA, MBDB, PMA, 4-MTA, 2CB), and putrefactive amines (phenylethylamine, putrescine, tryptamine, tyramine) were analyzed to determine cross-reactivity. Results of the standard curve studies show the capacity of both Direct ELISA kits to confidently detect down to 3 ng/mL interday (PBS matrix; CVs 6.3-15.5%). Cross-reactivity relative to that of 50 ng/mL preparations of the target compounds demonstrated that the Direct ELISA kit for amphetamine also detected MDA (282%), PMA (265%), 4-MTA (280%), and phentermine (61%), and the Direct ELISA for methamphetamine also assayed positive for MDMA (73%), MDEA (18%), pseudoephedrine (19%), MBDB (8%), and ephedrine (9%). Matrix studies demonstrated that both ELISA kits could be applied to screening of blood, urine, and saliva to a concentration of 6 ng/mL or lower. In conclusion, the Bio-Quant Direct ELISA kits for amphetamine and methamphetamine are fast and accurate and have demonstrated themselves to be useful tools in routine toxicological testing.


Assuntos
Aminas/análise , Anfetaminas/análise , Drogas Desenhadas/análise , Ensaio de Imunoadsorção Enzimática , Medicina Legal/métodos , Kit de Reagentes para Diagnóstico , Detecção do Abuso de Substâncias/métodos , Aminas/sangue , Aminas/imunologia , Aminas/urina , Anfetamina/análise , Anfetaminas/sangue , Anfetaminas/imunologia , Anfetaminas/urina , Anticorpos , Especificidade de Anticorpos , Reações Cruzadas , Humanos , Metanfetamina/análise , Mudanças Depois da Morte , Reprodutibilidade dos Testes , Saliva/química , Sensibilidade e Especificidade
6.
Rapid Commun Mass Spectrom ; 20(15): 2259-64, 2006.
Artigo em Inglês | MEDLINE | ID: mdl-16810638

RESUMO

This paper describes the application of ultra-performance liquid chromatography/tandem mass spectrometry (UPLC/MS/MS) technology to separate and identify amphetamine-type substances (amphetamine, methamphetamine), common and novel designer analogues (MDA, MDMA, PMA, 4-MTA, MBDB), and ketamine using Acquity UPLC/Micromass Quattro Micro API mass spectrometer instrumentation (Waters Corporation, USA). From injection of drug reference standards, it was demonstrated that these compounds can be identified by product ion mass spectra in less than 4 min total analysis time, indicating that the technological advancements associated with UPLC/MS/MS allow it to serve as a powerful analytical tool for high-throughput testing. In addition to demonstrating the separation and response of these drug compounds under the stated UPLC/MS/MS conditions, we believe the acquired product ion spectra will be a beneficial reference to laboratories interested in incorporating the use of this technology in the routine analysis of drugs of abuse.


Assuntos
Anfetaminas/análise , Cromatografia Líquida/métodos , Drogas Desenhadas/análise , Ketamina/análise , Microquímica/métodos , Espectrometria de Massas por Ionização por Electrospray/métodos , Detecção do Abuso de Substâncias/métodos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
7.
J Chromatogr B Analyt Technol Biomed Life Sci ; 836(1-2): 111-5, 2006 May 19.
Artigo em Inglês | MEDLINE | ID: mdl-16617037

RESUMO

We have recently seen the emergence of ultra-performance liquid chromatography (UPLC) coupled to mass spectrometry as an alternative to traditional high-performance liquid chromatography techniques. The strengths of UPLC technology promote the ability to separate and identify drug compounds with significant gains in resolution and sensitivity and marked reductions in the overall time of analysis. As increased throughput is the desire of the practical toxicology laboratory, the aim of this study was to trial commercially available technology by assessment of the separation of several commonly encountered amphetamine-type substances. From injection of a poly-drug reference standard and whole blood extract, we successfully separated and identified amphetamine, methamphetamine, ephedrine, pseudoephedrine, phentermine, MDA, MDMA, MDEA and ketamine in less than 3 min using the Acquity UPLC-Micromass Quattro Micro API MS instrumentation (Waters Corporation, USA). In addition to this significant reduction in overall run time, all peaks exhibited acceptable resolution using selected ion recording (SIR), with analysis indicating the capability to separate 5-11 peaks in 1.75 min using the current system parameters. From this introductory data, it is therefore indicated that the technological advancements defining ultra-performance liquid chromatography will allow it to serve as a powerful analytical tool for rapid throughput analysis.


Assuntos
Anfetaminas/análise , Cromatografia Líquida/métodos , Medicina Legal , Ketamina/análise , Espectrometria de Massas/métodos , Humanos , Espectrofotometria Ultravioleta
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA