Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
Water Res ; 257: 121690, 2024 Jun 15.
Artigo em Inglês | MEDLINE | ID: mdl-38723351

RESUMO

Densification is a novel intensification strategy with the potential to improve treatment capacity within existing continuous-flow (CF) water resource recovery facilities at low capital and operating costs and at relatively small particle sizes compared to typical aerobic granular sludge (AGS) systems. To achieve densification, biological selection principles derived from selector design and AGS concepts have been coupled with physical selection via hydrocyclones at full-scale CF facilities to promote the growth and retention of granules. This combination lowers the sludge volume index (SVI) through superior sludge settling and paves the way for optimized nutrient removal and energy efficiency in low dissolved oxygen conditions. This paper sheds light on the benefits of densification. It delves into areas of advancement to further its implementation: hydrocyclone design, selector zone design, operational guidelines, and the target range for particle sizes and granule fractions.


Assuntos
Esgotos , Eliminação de Resíduos Líquidos , Esgotos/química , Eliminação de Resíduos Líquidos/métodos , Tamanho da Partícula , Reatores Biológicos
2.
Water Res ; 198: 117119, 2021 Jun 15.
Artigo em Inglês | MEDLINE | ID: mdl-33957310

RESUMO

An aerobic granular sludge (AGS) pilot plant fed with a mixture of acetate amended centrate and secondary effluent was used to investigate the optimal granule size range for simultaneous nitrification and denitrification (SND) and ortho-phosphate removal. The anaerobic phase was mixed to understand how AGS will perform if integrated with a continuous flow activated sludge system that cannot feed the influent through the settled sludge bed. Five different granule size fractions were taken from the pilot (operated at DO setpoint of 2mgO2/L) and each size was subjected to activity tests in a well-controlled lab-scale AGS reactor at four dissolved oxygen (DO) concentrations of 1, 2, 3, and 4 mgO2/L. The size fractions were: 212 - 600 µm, 600 - 1000 µm, 1000 - 1400 µm, 1400 - 2000 µm, and >2000 µm. The smallest size range (212 - 600 µm) had the highest nitrification and phosphate removal rates at DO setpoints from 1 - 3 mgO2/L, which was attributed to the higher aerobic volume fraction in small granules and hence a higher abundance of phosphorus accumulating organisms (PAO) and ammonia oxidizing bacteria (AOB). In comparison, large granules (>1000 µm) had 1.4 - 4.7 times lower ammonia oxidation rates than the smallest size range, which aligned with their lower AOB abundance relative to granule biomass. The granules with the highest anoxic volume fraction had the highest abundance of nitrite reductase genes (nir gene) but did not show the highest specific nitrogen removal rate. Instead, smaller granules (212 - 600 and 600 - 1000 µm), which had a lower nir gene abundance, had the highest specific nitrogen removal rates (1.2 - 3.1 times higher than larger granules) across all DO values except at 4 mgO2/L. At a DO setpoint of 4 mgO2/L, nitrite production by ammonia oxidation (ammonia monooxygenase) exceeded nitrite reduction by nitrite reductase in granules smaller than 1000 µm, in addition, some denitrifying heterotrophs switched to oxygen utilization in deeper layers hence suppressing denitrification activity. At the DO range of 2 - 4 mg/L, granular size had a greater effect on nutrient removal than DO. Therefore, for AGS developed at an average DO setpoint of 2 mgO2/L, selecting for size fractions in the range of 212 - 1000 µm and avoiding DO values higher than 3 mgO2/L can achieve both a higher nitrogen removal capacity and energy savings. This study is the first to investigate the influence of different DO values on SND and biological phosphorus removal performance of different aerobic granular sludge sizes.


Assuntos
Nitrogênio , Esgotos , Reatores Biológicos , Desnitrificação , Nitrificação , Nitrogênio/análise , Fosfatos , Fósforo , Eliminação de Resíduos Líquidos
3.
Water Res ; 188: 116445, 2021 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-33039834

RESUMO

The relationship between ammonia oxidation rate, nitrifiers population, and modelled aerobic zone volume in different granule sizes was investigated using aerobic granular sludge from a pilot-scale reactor. The pilot was fed with centrate and secondary effluent amended with acetate as the main carbon source. The maximum specific ammonia oxidation rates and community composition of different aerobic granular sludge size fractions were evaluated by batch tests, quantitative PCR, and genomic analysis. Small (331µm) granules had a 4.72 ± 0.09 times higher maximum specific ammonia oxidizing rate per 1 gVSS, and a 4.05 ± 0.17 times higher specific amoA gene copy number than large (2225µm) granules per 1 gram of wet biomass. However, when related to surface area, small granules had 1.43 ± 0.01 times lower maximum specific ammonia oxidation rate and a 1.66 ± 0.04 times lower specific amoA gene copy number per unit surface than large granules. Experimental results aligned with modeling results in which smaller granules had a higher specific aerobic zone volume to biomass and lower specific aerobic zone volume to surface area. Aerobic granular sludge reactors having the same average diameter of granules may have very different proportions of granule size fractions and hence possess different nitrification rates. Therefore, instead of the commonly reported average granule diameter, a new method was proposed to determine the aerobic volume density per sample, which correlated well with the nitrification rate. This work provides a roadmap to control nitrification capacity by two methods: (a) crushing larger granules into smaller fractions, or (b) increasing the mixed liquor suspended solid concentration to increase the total aerobic zone volume of the system.


Assuntos
Nitrificação , Esgotos , Aerobiose , Amônia , Biomassa , Reatores Biológicos , Eliminação de Resíduos Líquidos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA