Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
Br J Ophthalmol ; 108(3): 380-385, 2024 02 21.
Artigo em Inglês | MEDLINE | ID: mdl-36810151

RESUMO

PURPOSE: To evaluate the long-term visual acuity (VA) outcome of cataract surgery in inflammatory eye disease. SETTING: Tertiary care academic centres. DESIGN: Multicentre retrospective cohort study. METHODS: A total of 1741 patients with non-infectious inflammatory eye disease (2382 eyes) who underwent cataract surgery while under tertiary uveitis management were included. Standardised chart review was used to gather clinical data. Multivariable logistic regression models with adjustment for intereye correlations were performed to evaluate the prognostic factors for VA outcomes. Main outcome measure was VA after cataract surgery. RESULTS: Uveitic eyes independent of anatomical location showed improved VA from baseline (mean 20/200) to within 3 months (mean 20/63) of cataract surgery and maintained through at least 5 years of follow-up (mean 20/63). Eyes that achieved 20/40 or better VA at 1 year were more likely to have scleritis (OR=1.34, p<0.0001) or anterior uveitis (OR=2.2, p<0.0001), VA 20/50 to 20/80 (OR 4.76 as compared with worse than 20/200, p<0.0001) preoperatively, inactive uveitis (OR=1.49, p=0.03), have undergone phacoemulsification (OR=1.45 as compared with extracapsular cataract extraction, p=0.04) or have had intraocular lens placement (OR=2.13, p=0.01). Adults had better VA immediately after surgery, with only 39% (57/146) paediatric eyes at 20/40 or better at 1 year. CONCLUSIONS: Our results suggest that adult and paediatric eyes with uveitis typically have improved VA following cataract surgery and remain stable thereafter for at least 5 years.


Assuntos
Extração de Catarata , Catarata , Doenças da Túnica Conjuntiva , Facoemulsificação , Uveíte , Adulto , Humanos , Criança , Estudos Retrospectivos , Catarata/complicações , Resultado do Tratamento , Extração de Catarata/métodos , Acuidade Visual , Uveíte/complicações , Uveíte/diagnóstico , Uveíte/cirurgia , Transtornos da Visão
2.
Ophthalmology ; 121(7): 1322-32, 2014 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-24629312

RESUMO

PURPOSE: To compare optic disc perfusion between normal subjects and subjects with glaucoma using optical coherence tomography (OCT) angiography and to detect optic disc perfusion changes in glaucoma. DESIGN: Observational, cross-sectional study. PARTICIPANTS: Twenty-four normal subjects and 11 patients with glaucoma were included. METHODS: One eye of each subject was scanned by a high-speed 1050-nm-wavelength swept-source OCT instrument. The split-spectrum amplitude-decorrelation angiography (SSADA) algorithm was used to compute 3-dimensional optic disc angiography. A disc flow index was computed from 4 registered scans. Confocal scanning laser ophthalmoscopy (cSLO) was used to measure disc rim area, and stereo photography was used to evaluate cup/disc (C/D) ratios. Wide-field OCT scans over the discs were used to measure retinal nerve fiber layer (NFL) thickness. MAIN OUTCOME MEASURES: Variability was assessed by coefficient of variation (CV). Diagnostic accuracy was assessed by sensitivity and specificity. Comparisons between glaucoma and normal groups were analyzed by Wilcoxon rank-sum test. Correlations among disc flow index, structural assessments, and visual field (VF) parameters were assessed by linear regression. RESULTS: In normal discs, a dense microvascular network was visible on OCT angiography. This network was visibly attenuated in subjects with glaucoma. The intra-visit repeatability, inter-visit reproducibility, and normal population variability of the optic disc flow index were 1.2%, 4.2%, and 5.0% CV, respectively. The disc flow index was reduced by 25% in the glaucoma group (P = 0.003). Sensitivity and specificity were both 100% using an optimized cutoff. The flow index was highly correlated with VF pattern standard deviation (R(2) = 0.752, P = 0.001). These correlations were significant even after accounting for age, C/D area ratio, NFL, and rim area. CONCLUSIONS: Optical coherence tomography angiography, generated by the new SSADA, repeatably measures optic disc perfusion and may be useful in the evaluation of glaucoma and glaucoma progression.


Assuntos
Angiofluoresceinografia , Glaucoma/fisiopatologia , Disco Óptico/irrigação sanguínea , Vasos Retinianos/fisiologia , Tomografia de Coerência Óptica , Idoso , Velocidade do Fluxo Sanguíneo , Pressão Sanguínea , Estudos Transversais , Feminino , Glaucoma/classificação , Voluntários Saudáveis , Humanos , Imageamento Tridimensional , Pressão Intraocular , Fluxometria por Laser-Doppler , Masculino , Pessoa de Meia-Idade , Fibras Nervosas/patologia , Oftalmoscopia , Fluxo Sanguíneo Regional , Reprodutibilidade dos Testes , Células Ganglionares da Retina/patologia , Sensibilidade e Especificidade , Testes de Campo Visual , Campos Visuais
3.
Trans Am Ophthalmol Soc ; 111: 34-45, 2013 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-24167323

RESUMO

PURPOSE: To use optical coherence tomography (OCT) to measure corneal power and improve the selection of intraocular lens (IOL) power in cataract surgeries after laser vision correction. METHODS: Patients with previous myopic laser vision corrections were enrolled in this prospective study from two eye centers. Corneal thickness and power were measured by Fourier-domain OCT. Axial length, anterior chamber depth, and automated keratometry were measured by a partial coherence interferometer. An OCT-based IOL formula was developed. The mean absolute error of the OCT-based formula in predicting postoperative refraction was compared to two regression-based IOL formulae for eyes with previous laser vision correction. RESULTS: Forty-six eyes of 46 patients all had uncomplicated cataract surgery with monofocal IOL implantation. The mean arithmetic prediction error of postoperative refraction was 0.05 ± 0.65 diopter (D) for the OCT formula, 0.14 ± 0.83 D for the Haigis-L formula, and 0.24 ± 0.82 D for the no-history Shammas-PL formula. The mean absolute error was 0.50 D for OCT compared to a mean absolute error of 0.67 D for Haigis-L and 0.67 D for Shammas-PL. The adjusted mean absolute error (average prediction error removed) was 0.49 D for OCT, 0.65 D for Haigis-L (P=.031), and 0.62 D for Shammas-PL (P=.044). For OCT, 61% of the eyes were within 0.5 D of prediction error, whereas 46% were within 0.5 D for both Haigis-L and Shammas-PL (P=.034). CONCLUSIONS: The predictive accuracy of OCT-based IOL power calculation was better than Haigis-L and Shammas-PL formulas in eyes after laser vision correction.


Assuntos
Córnea , Cirurgia da Córnea a Laser , Implante de Lente Intraocular , Lentes Intraoculares , Miopia/cirurgia , Tomografia de Coerência Óptica/métodos , Idoso , Comprimento Axial do Olho/patologia , Córnea/anatomia & histologia , Córnea/fisiologia , Feminino , Análise de Fourier , Humanos , Masculino , Pessoa de Meia-Idade , Miopia/fisiopatologia , Óptica e Fotônica , Facoemulsificação , Valor Preditivo dos Testes , Estudos Prospectivos
4.
Cornea ; 26(5): 515-9, 2007 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-17525642

RESUMO

PURPOSE: To evaluate the use of corneal donor tissue deemed unsuitable for full-thickness penetrating keratoplasty (PK) for use in deep lamellar endothelial keratoplasty (DLEK) and to compare postoperative results to those of DLEK surgery using donor tissue that is suitable for PK. METHODS: Small-incision DLEK surgery was performed using 39 donor corneas unsuitable for PK. Thirty-five donors had anterior scars or opacities, 3 donors had pterygia within the 8-mm zone, and 1 had prior LASIK. All donor preparation was completed by manual stromal dissection. The DLEK surgical and postoperative courses were reviewed. Preoperative and 6-month postoperative results of this study group were compared with a control group consisting of the first 55 consecutive small-incision DLEK patients receiving donor corneas that had no criteria excluding them from use in PK. Four eyes in the study group and 1 eye in the control group had the confounding variables of the presence of an anterior-chamber lens or surgical vitrectomy with macular disease in the recipient eye. RESULTS: There was no significant difference in preoperative measurements of best spectacle-corrected visual acuity (BSCVA; P = 0.372), donor endothelial cell density (ECD; P = 0.749), or corneal topography [surface regularity index (SRI), P = 0.485; or surface asymmetry index (SAI), P = 0.154] between the 2 groups. For the patients receiving corneas deemed unacceptable for PK, at 6 months after surgery, the vision (P = 0.002) and corneal topography measurements improved significantly from before surgery (SRI, P < 0.001; SAI, P < 0.001), and there was no significant change in refractive astigmatism (P = 0.240). There was a significant difference in the vision at 6 months postoperatively between the overall study group and the control group, with the mean vision of the study group at 20/56 and the control group at 20/43 (P = 0.015). If eyes with known cystoid macular edema (CME) and vitrectomy are removed from each group, there is no significant difference in vision at 6 months between the study group and the control group (P = 0.110), with the average BSCVA of those receiving donor corneas unsuitable for PK equal to 20/48 (range, 20/25-20/200) and the average vision for those receiving PK-acceptable donor tissue equal to 20/43 (range, 20/20-20/80). The 6-month average refractive astigmatism of the study group was 1.12 +/- 0.99 D (range, 0.00-4.00 D), and the average endothelial cell count was 2064 +/- 396 cells/mm(2) (range, 1208-2957 cells/mm(2)). There was no significant difference in 6-month postoperative endothelial cell count (P = 0.443), refractive astigmatism (P = 0.567), or corneal topography (SRI, P = 0.332; SAI, P = 0.110) in study patients who received corneas unsuitable for PK compared with control patients who received corneas suitable for PK. CONCLUSIONS: Endothelial keratoplasty such as DLEK surgery with manual donor preparation broadens the donor pool by enabling corneas that cannot be used for PK to be used for selective endothelial transplantation without deleterious postoperative results.


Assuntos
Transplante de Córnea/métodos , Seleção do Doador/normas , Endotélio Corneano/transplante , Distrofia Endotelial de Fuchs/cirurgia , Doadores de Tecidos , Idoso , Idoso de 80 Anos ou mais , Topografia da Córnea , Feminino , Guias como Assunto , Humanos , Ceratoplastia Penetrante/normas , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Estudos Retrospectivos , Acuidade Visual
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA