1.
J Am Soc Mass Spectrom ; 35(5): 943-950, 2024 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-38623743

RESUMO

Triboelectric nanogenerators (TENG) are useful devices for converting mechanical motion into electric current using readily available materials. Though the applications for these devices span across many fields, TENG can be leveraged for mass spectrometry (MS) as inexpensive and effective power supplies for pulsed nanoelectrospray ionization (nESI). The inherently discontinuous spray provided by TENG is particularly useful in scenarios where high sample economy is imperative, as in the case of ultraprecious samples. Previous work has shown the utility of TENG MS as a highly sensitive technique capable of yielding quality spectra from only a few microliters of sample at low micromolar concentrations. As the field of miniaturized, fieldable mass spectrometers grows, it remains critical to develop advanced ion sources with similarly small power requirements and footprints. Here, we present a redesigned TENG ion source with a sub-1000 USD material cost, lower power consumption, reduced footprint, and improved capabilities. We validate the performance of this new device for a diverse set of applications, including lipid double bond localization and native protein analysis.

2.
Anal Chem ; 95(2): 1047-1056, 2023 01 17.
Artigo em Inglês | MEDLINE | ID: mdl-36595469

RESUMO

Ion mobility (IM) spectrometry provides semiorthogonal data to mass spectrometry (MS), showing promise for identifying unknown metabolites in complex non-targeted metabolomics data sets. While current literature has showcased IM-MS for identifying unknowns under near ideal circumstances, less work has been conducted to evaluate the performance of this approach in metabolomics studies involving highly complex samples with difficult matrices. Here, we present a workflow incorporating de novo molecular formula annotation and MS/MS structure elucidation using SIRIUS 4 with experimental IM collision cross-section (CCS) measurements and machine learning CCS predictions to identify differential unknown metabolites in mutant strains of Caenorhabditis elegans. For many of those ion features, this workflow enabled the successful filtering of candidate structures generated by in silico MS/MS predictions, though in some cases, annotations were challenged by significant hurdles in instrumentation performance and data analysis. While for 37% of differential features we were able to successfully collect both MS/MS and CCS data, fewer than half of these features benefited from a reduction in the number of possible candidate structures using CCS filtering due to poor matching of the machine learning training sets, limited accuracy of experimental and predicted CCS values, and lack of candidate structures resulting from the MS/MS data. When using a CCS error cutoff of ±3%, on average, 28% of candidate structures could be successfully filtered. Herein, we identify and describe the bottlenecks and limitations associated with the identification of unknowns in non-targeted metabolomics using IM-MS to focus and provide insights into areas requiring further improvement.


Assuntos
Metabolômica , Espectrometria de Massas em Tandem , Metabolômica/métodos , Aprendizado de Máquina , Espectrometria de Mobilidade Iônica/métodos
3.
Anal Chem ; 94(50): 17456-17466, 2022 12 20.
Artigo em Inglês | MEDLINE | ID: mdl-36473057

RESUMO

Metabolite annotation continues to be the widely accepted bottleneck in nontargeted metabolomics workflows. Annotation of metabolites typically relies on a combination of high-resolution mass spectrometry (MS) with parent and tandem measurements, isotope cluster evaluations, and Kendrick mass defect (KMD) analysis. Chromatographic retention time matching with standards is often used at the later stages of the process, which can also be followed by metabolite isolation and structure confirmation utilizing nuclear magnetic resonance (NMR) spectroscopy. The measurement of gas-phase collision cross-section (CCS) values by ion mobility (IM) spectrometry also adds an important dimension to this workflow by generating an additional molecular parameter that can be used for filtering unlikely structures. The millisecond timescale of IM spectrometry allows the rapid measurement of CCS values and allows easy pairing with existing MS workflows. Here, we report on a highly accurate machine learning algorithm (CCSP 2.0) in an open-source Jupyter Notebook format to predict CCS values based on linear support vector regression models. This tool allows customization of the training set to the needs of the user, enabling the production of models for new adducts or previously unexplored molecular classes. CCSP produces predictions with accuracy equal to or greater than existing machine learning approaches such as CCSbase, DeepCCS, and AllCCS, while being better aligned with FAIR (Findable, Accessible, Interoperable, and Reusable) data principles. Another unique aspect of CCSP 2.0 is its inclusion of a large library of 1613 molecular descriptors via the Mordred Python package, further encoding the fine aspects of isomeric molecular structures. CCS prediction accuracy was tested using CCS values in the McLean CCS Compendium with median relative errors of 1.25, 1.73, and 1.87% for the 170 [M - H]-, 155 [M + H]+, and 138 [M + Na]+ adducts tested. For superclass-matched data sets, CCS predictions via CCSP allowed filtering of 36.1% of incorrect structures while retaining a total of 100% of the correct annotations using a ΔCCS threshold of 2.8% and a mass error of 10 ppm.


Assuntos
Algoritmos , Metabolômica , Metabolômica/métodos , Espectrometria de Massas/métodos , Cromatografia Líquida de Alta Pressão , Aprendizado de Máquina
4.
Front Mol Biosci ; 9: 930204, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36438654

RESUMO

Untargeted metabolomics studies are unbiased but identifying the same feature across studies is complicated by environmental variation, batch effects, and instrument variability. Ideally, several studies that assay the same set of metabolic features would be used to select recurring features to pursue for identification. Here, we developed an anchored experimental design. This generalizable approach enabled us to integrate three genetic studies consisting of 14 test strains of Caenorhabditis elegans prior to the compound identification process. An anchor strain, PD1074, was included in every sample collection, resulting in a large set of biological replicates of a genetically identical strain that anchored each study. This enables us to estimate treatment effects within each batch and apply straightforward meta-analytic approaches to combine treatment effects across batches without the need for estimation of batch effects and complex normalization strategies. We collected 104 test samples for three genetic studies across six batches to produce five analytical datasets from two complementary technologies commonly used in untargeted metabolomics. Here, we use the model system C. elegans to demonstrate that an augmented design combined with experimental blocks and other metabolomic QC approaches can be used to anchor studies and enable comparisons of stable spectral features across time without the need for compound identification. This approach is generalizable to systems where the same genotype can be assayed in multiple environments and provides biologically relevant features for downstream compound identification efforts. All methods are included in the newest release of the publicly available SECIMTools based on the open-source Galaxy platform.

5.
J Am Soc Mass Spectrom ; 33(5): 750-759, 2022 May 04.
Artigo em Inglês | MEDLINE | ID: mdl-35378036

RESUMO

The interpretation of ion mobility coupled to mass spectrometry (IM-MS) data to predict unknown structures is challenging and depends on accurate theoretical estimates of the molecular ion collision cross section (CCS) against a buffer gas in a low or atmospheric pressure drift chamber. The sensitivity and reliability of computational prediction of CCS values depend on accurately modeling the molecular state over accessible conformations. In this work, we developed an efficient CCS computational workflow using a machine learning model in conjunction with standard DFT methods and CCS calculations. Furthermore, we have performed Traveling Wave IM-MS (TWIMS) experiments to validate the extant experimental values and assess uncertainties in experimentally measured CCS values. The developed workflow yielded accurate structural predictions and provides unique insights into the likely preferred conformation analyzed using IM-MS experiments. The complete workflow makes the computation of CCS values tractable for a large number of conformationally flexible metabolites with complex molecular structures.


Assuntos
Espectrometria de Mobilidade Iônica , Aprendizado de Máquina , Espectrometria de Mobilidade Iônica/métodos , Conformação Molecular , Estrutura Molecular , Reprodutibilidade dos Testes
6.
Artigo em Inglês | MEDLINE | ID: mdl-28868498

RESUMO

Guanidinoacetate methyltransferase (GAMT) deficiency is an autosomal recessive genetic disorder which results in global developmental delay and intellectual disability. There is evidence that early treatment prevents intellectual disability and seizures. GAMT deficiency is now being discussed as a potential addition to the U.S. Recommended Uniform Screening Panel (RUSP); the availability of suitable screening methods must be considered. A neonatal screening derivatized method to quantify creatine (CRE) and guanidinoacetic acid (GAA) in dried blood spots by tandem mass spectrometry (MS/MS) has been described. Its key feature is the ability to detect CRE and GAA in the same extract generated from neonatal DBS during amino acids (AA) and acylcarnitines (AC) analysis. More laboratories are adopting non-derivatized MS/MS screening methods. We describe an improved, non-derivatized DBS extraction and MS/MS analytical method (AAAC-GAMT) which incorporates quantitation of CRE and GAA into routine analysis of amino acids, acylcarnitines, and succinylacetone. The non-derivatized AAAC-GAMT method performs comparably to the stand-alone GAMT and non-derivatized AAAC screening methods, evidencing its potential suitability for high-throughput GAMT neonatal screening.