Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
3.
Indian J Med Res ; 152(1 & 2): 88-94, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32893844

RESUMO

BACKGROUND & OBJECTIVES: Public health and diagnostic laboratories are facing huge sample loads for COVID-19 diagnosis by real-time reverse transcription-polymerase chain reaction (RT-PCR). High sensitivity of optimized real-time RT-PCR assays makes pooled testing a potentially efficient strategy for resource utilization when positivity rates for particular regions or groups of individuals are low. We report here a comparative analysis of pooled testing for 5- and 10-sample pools by real-time RT-PCR across 10 COVID-19 testing laboratories in India. METHODS: Ten virus research and diagnostic laboratories (VRDLs) testing for COVID-19 by real-time RT-PCR participated in this evaluation. At each laboratory, 100 nasopharyngeal swab samples including 10 positive samples were used to create 5- and 10-sample pools with one positive sample in each pool. RNA extraction and real-time RT-PCR for SARS-CoV-2-specific E gene target were performed for individual positive samples as well as pooled samples. Concordance between individual sample testing and testing in the 5- or 10-sample pools was calculated, and the variation across sites and by sample cycle threshold (Ct) values was analyzed. RESULTS: A total of 110 each of 5- and 10-sample pools were evaluated. Concordance between the 5-sample pool and individual sample testing was 100 per cent in the Ct value ≤30 cycles and 95.5 per cent for Ctvalues ≤33 cycles. Overall concordance between the 5-sample pooled and individual sample testing was 88 per cent while that between 10-sample pool and individual sample testing was 66 per cent. Although the concordance rates for both the 5- and 10-sample pooled testing varied across laboratories, yet for samples with Ct values ≤33 cycles, the concordance was ≥90 per cent across all laboratories for the 5-sample pools. INTERPRETATION & CONCLUSIONS: Results from this multi-site assessment suggest that pooling five samples for SARS-CoV-2 detection by real-time RT-PCR may be an acceptable strategy without much loss of sensitivity even for low viral loads, while with 10-sample pools, there may be considerably higher numbers of false negatives. However, testing laboratories should perform validations with the specific RNA extraction and RT-PCR kits in use at their centres before initiating pooled testing.


Assuntos
Betacoronavirus/isolamento & purificação , Técnicas de Laboratório Clínico , Infecções por Coronavirus/diagnóstico , Pneumonia Viral/diagnóstico , RNA Viral/isolamento & purificação , Betacoronavirus/genética , Betacoronavirus/patogenicidade , COVID-19 , Teste para COVID-19 , Vacinas contra COVID-19 , Infecções por Coronavirus/epidemiologia , Infecções por Coronavirus/genética , Infecções por Coronavirus/virologia , Testes Diagnósticos de Rotina/métodos , Feminino , Humanos , Índia/epidemiologia , Masculino , Pandemias , Pneumonia Viral/epidemiologia , Pneumonia Viral/genética , Pneumonia Viral/virologia , RNA Viral/genética , Reação em Cadeia da Polimerase em Tempo Real/métodos , Reação em Cadeia da Polimerase Via Transcriptase Reversa , SARS-CoV-2 , Testes Sorológicos , Manejo de Espécimes , Carga Viral/genética
4.
PLoS Negl Trop Dis ; 14(2): e0007982, 2020 02.
Artigo em Inglês | MEDLINE | ID: mdl-32012162

RESUMO

BACKGROUND: Government of India is committed to eliminate measles and control rubella/congenital rubella syndrome (CRS) by 2020. In 2016, CRS surveillance was established in five sentinel sites. We analyzed surveillance data to describe the epidemiology of CRS in India. METHODOLOGY/PRINCIPAL FINDINGS: We used case definitions adapted from the WHO-recommended standards for CRS surveillance. Suspected patients underwent complete clinical examination including cardiovascular system, ophthalmic examination and assessment for hearing impairment. Sera were tested for presence of IgM and IgG antibodies against rubella. Of the 645 suspected CRS patients enrolled during two years, 137 (21.2%) were classified as laboratory confirmed CRS and 8 (1.2%) as congenital rubella infection. The median age of laboratory confirmed CRS infants was 3 months. Common clinical features among laboratory confirmed CRS patients included structural heart defects in 108 (78.8%), one or more eye signs (cataract, glaucoma, pigmentary retinopathy) in 82 (59.9%) and hearing impairment in 51. (38.6%) Thirty-three (24.1%) laboratory confirmed CRS patients died over a period of 2 years. Surveillance met the quality indicators in terms of adequacy of investigation, adequacy of sample collection for serological diagnosis as well as virological confirmation. CONCLUSIONS/SIGNIFICANCE: About one fifth suspected CRS patients were laboratory confirmed, indicating significance of rubella as a persistent public health problem in India. Continued surveillance will generate data to monitor the progress made by the rubella control program in the country.


Assuntos
Síndrome da Rubéola Congênita/epidemiologia , Adolescente , Adulto , Anticorpos Antivirais/sangue , Feminino , Humanos , Imunoglobulina M/sangue , Índia/epidemiologia , Lactente , Recém-Nascido , Masculino , Síndrome da Rubéola Congênita/sangue , Síndrome da Rubéola Congênita/diagnóstico , Síndrome da Rubéola Congênita/mortalidade , Vigilância de Evento Sentinela , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA