Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 343
Filtrar
1.
World J Pediatr Congenit Heart Surg ; : 21501351241247503, 2024 May 23.
Artigo em Inglês | MEDLINE | ID: mdl-38780412

RESUMO

Background: Pediatric pulmonary vein stenosis (PVS) is often progressive and treatment-refractory, requiring multiple interventions. Hybrid pulmonary vein interventions (HPVIs), involving intraoperative balloon angioplasty or stent placement, leverage surgical access and customization to optimize patency while facilitating future transcatheter procedures. We review our experience with HPVI and explore potential applications of this collaborative approach. Methods: Retrospective chart review of all HPVI cases between 2009 to 2023. Results: Ten patients with primary (n = 5) or post-repair (n = 5) PVS underwent HPVI at median age of 12.7 months (range 6.6 months-9.5 years). Concurrent surgical PVS repair was performed in 7/10 cases. Hybrid pulmonary vein intervention was performed on 17 veins, 13 (76%) with prior surgical or transcatheter intervention(s). One patient underwent intraoperative balloon angioplasty of an existing stent. In total, 18 stents (9 bare metal [5-10 mm diameter], 9 drug eluting [3.5-5 mm diameter]) were placed in 16 veins. At first angiography (median 48 days [range 7 days-2.8 years] postoperatively), 8 of 16 (50%) HPVI-stented veins developed in-stent stenosis. Two patients died from progressive PVS early in the study, one prior to planned reintervention. Median time to first pulmonary vein reintervention was 86 days (10 days-2.8 years; 8/10 patients, 13/17 veins). At median survivor follow-up of 2.2 years (2.3 months-13.1 years), 1 of 11 surviving HPVI veins were completely occluded. Conclusions: Hybrid pulmonary vein intervention represents a viable adjunct to existing PVS therapies, with promising flexibility to address limitations of surgical and transcatheter modalities. Reintervention is anticipated, necessitating evaluation of long-term benefits and durability as utilization increases.

2.
Ann Thorac Surg ; 2024 May 10.
Artigo em Inglês | MEDLINE | ID: mdl-38735511

RESUMO

BACKGROUND: We describe outcomes and management strategies for single ventricle and bilaterally discontinuous pulmonary arteries (PAs) originating from bilateral ductus arteriosus. METHODS: We reviewed 22 patients with aforementioned anatomy and PA centralization from 1995-2023, excluding those with biventricular repair. RESULTS: Median age at centralization was 9 days (range 0 days-2 years). Centralization was performed with systemic-to-pulmonary shunt (n=20, 91%; 2 following bilateral ductal stents) or bidirectional cavopulmonary connection (n=2, 9%) via pericardial roll (n=14, 64%), patch-augmented direct anastomosis (n=7, 32%), and interposition graft (n=1, 5%) techniques. Concurrent total anomalous pulmonary venous connection (TAPVC, n=11, 50%) was associated with significantly inferior survival (P=.01). Five patients (23%) died at a median of 59 (6-257) days post-centralization, all with non-cardiac TAPVC. At latest follow-up for 17 survivors (median 13.5 [0.5-25.1] years post-centralization), 12 completed Fontan, 4 completed second stage palliation, and 1 was transplanted prior to second stage palliation. Fourteen patients (64%) required PA reintervention, including 3 with reoperations independent of staged palliation. Baseline to pre-second stage echocardiography demonstrated branch PA growth with significantly increased diameters (left P=.0006, right P=.0002); z-scores significantly increased for right (P=.004) but not left (P=.11). CONCLUSIONS: Successful single ventricle palliation is possible, though high-risk, for patients with bilateral discontinuous ductal PAs. Early post-centralization mortality remains substantial, particularly with associated non-cardiac TAPVC. Many require reintervention to maintain PA growth, typically concurrently with staged palliation.

3.
Circ Cardiovasc Interv ; 17(5): e013889, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38606564

RESUMO

BACKGROUND: Anatomic selection for Harmony valve implant is determined with the aid of a screening report and perimeter plot (PP) that depicts the perimeter-derived radius along the right ventricular outflow tract (RVOT) and projects device oversizing. The PP provides an estimation of suitability for implant, but its sensitivity as a screening method is unknown. This study was performed to describe anatomic features and outcomes in patients who underwent Harmony TPV25 implant despite a PP that predicted inadequate oversizing. METHODS: We reviewed RVOT anatomic features and measurements in patients who underwent transcatheter pulmonary valve replacement with the Harmony TPV25 device despite a PP that predicted inadequate oversizing. RESULTS: This study included 22 patients. There were no unsuccessful implants or adverse valve-related events. Anatomic features varied, but all patients fit into 1 of 3 anatomic types characterized by differences in RVOT dimensions. Type 1 patients (n=9) had a long RVOT with a choke point and a wide main pulmonary artery. Type 2 patients (n=6) had a short RVOT that was pyramidal in shape, with no choke point, and extensive main pulmonary artery lengthening/expansion during systole. Type 3 patients (n=7) had a short, bulbous main pulmonary artery with a choke point and an open pulmonary artery bifurcation. CONCLUSIONS: Transcatheter pulmonary valve replacement with the Harmony valve is feasible in some patients whose PP fit analysis predicts inadequate oversizing. All cases in this series fit into 1 of 3 anatomic patterns, which are not identified in the screening report. Implanters must review cases individually to assess the feasibility of the implant.


Assuntos
Cateterismo Cardíaco , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Desenho de Prótese , Valva Pulmonar , Humanos , Valva Pulmonar/cirurgia , Valva Pulmonar/diagnóstico por imagem , Valva Pulmonar/fisiopatologia , Implante de Prótese de Valva Cardíaca/instrumentação , Implante de Prótese de Valva Cardíaca/efeitos adversos , Cateterismo Cardíaco/instrumentação , Cateterismo Cardíaco/efeitos adversos , Resultado do Tratamento , Masculino , Feminino , Adolescente , Adulto Jovem , Criança , Adulto , Estudos Retrospectivos , Valor Preditivo dos Testes , Insuficiência da Valva Pulmonar/cirurgia , Insuficiência da Valva Pulmonar/fisiopatologia , Insuficiência da Valva Pulmonar/diagnóstico por imagem , Seleção de Pacientes , Tomada de Decisão Clínica , Recuperação de Função Fisiológica , Hemodinâmica
4.
J Am Coll Cardiol ; 83(14): 1310-1321, 2024 Apr 09.
Artigo em Inglês | MEDLINE | ID: mdl-38569760

RESUMO

BACKGROUND: Transcatheter pulmonary valve replacement (TPVR) with the self-expanding Harmony valve (Medtronic) is an emerging treatment for patients with native or surgically repaired right ventricular outflow tract (RVOT) pulmonary regurgitation (PR). Limited data are available since U.S. Food and Drug Administration approval in 2021. OBJECTIVES: In this study, the authors sought to evaluate the safety and short-term effectiveness of self-expanding TPVR in a real-world experience. METHODS: This was a multicenter registry study of consecutive patients with native RVOT PR who underwent TPVR through April 30, 2022, at 11 U.S. CENTERS: The primary outcome was a composite of hemodynamic dysfunction (PR greater than mild and RVOT mean gradient >30 mm Hg) and RVOT reintervention. RESULTS: A total of 243 patients underwent TPVR at a median age of 31 years (Q1-Q3: 19-45 years). Cardiac diagnoses were tetralogy of Fallot (71%), valvular pulmonary stenosis (21%), and other (8%). Acute technical success was achieved in all but 1 case. Procedural serious adverse events occurred in 4% of cases, with no device embolization or death. Hospital length of stay was 1 day in 86% of patients. Ventricular arrhythmia prompting treatment occurred in 19% of cases. At a median follow-up of 13 months (Q1-Q3: 8-19 months), 98% of patients had acceptable hemodynamic function. Estimated freedom from the composite clinical outcome was 99% at 1 year and 96% at 2 years. Freedom from TPVR-related endocarditis was 98% at 1 year. Five patients died from COVID-19 (n = 1), unknown causes (n = 2), and bloodstream infection (n = 2). CONCLUSIONS: In this large multicenter real-world experience, short-term clinical and hemodynamic outcomes of self-expanding TPVR therapy were excellent. Ongoing follow-up of this cohort will provide important insights into long-term outcomes.


Assuntos
Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Insuficiência da Valva Pulmonar , Valva Pulmonar , Humanos , Adulto , Valva Pulmonar/cirurgia , Implante de Prótese de Valva Cardíaca/efeitos adversos , Cateterismo Cardíaco/efeitos adversos , Resultado do Tratamento , Insuficiência da Valva Pulmonar/cirurgia , Insuficiência da Valva Pulmonar/etiologia , Sistema de Registros , Desenho de Prótese , Estudos Retrospectivos
5.
Catheter Cardiovasc Interv ; 103(6): 924-933, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38597297

RESUMO

BACKGROUND: Percutaneous pulmonary valve implantation (PPVI) is a non-surgical treatment for right ventricular outflow tract (RVOT) dysfunction. During PPVI, a stented valve, delivered via catheter, replaces the dysfunctional pulmonary valve. Stent oversizing allows valve anchoring within the RVOT, but overexpansion can intrude on the surrounding structures. Potentially dangerous outcomes include aortic valve insufficiency (AVI) from aortic root (AR) distortion and myocardial ischemia from coronary artery (CA) compression. Currently, risks are evaluated via balloon angioplasty/sizing before stent deployment. Patient-specific finite element (FE) analysis frameworks can improve pre-procedural risk assessment, but current methods require hundreds of hours of high-performance computation. METHODS: We created a simplified method to simulate the procedure using patient-specific FE models for accurate, efficient pre-procedural PPVI (using balloon expandable valves) risk assessment. The methodology was tested by retrospectively evaluating the clinical outcome of 12 PPVI candidates. RESULTS: Of 12 patients (median age 14.5 years) with dysfunctional RVOT, 7 had native RVOT and 5 had RV-PA conduits. Seven patients had undergone successful RVOT stent/valve placement, three had significant AVI on balloon testing, one had left CA compression, and one had both AVI and left CA compression. A model-calculated change of more than 20% in lumen diameter of the AR or coronary arteries correctly predicted aortic valve sufficiency and/or CA compression in all the patients. CONCLUSION: Agreement between FE results and clinical outcomes is excellent. Additionally, these models run in 2-6 min on a desktop computer, demonstrating potential use of FE analysis for pre-procedural risk assessment of PPVI in a clinically relevant timeframe.


Assuntos
Cateterismo Cardíaco , Análise de Elementos Finitos , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Modelos Cardiovasculares , Modelagem Computacional Específica para o Paciente , Desenho de Prótese , Valva Pulmonar , Humanos , Valva Pulmonar/fisiopatologia , Valva Pulmonar/cirurgia , Valva Pulmonar/diagnóstico por imagem , Implante de Prótese de Valva Cardíaca/instrumentação , Implante de Prótese de Valva Cardíaca/efeitos adversos , Medição de Risco , Adolescente , Resultado do Tratamento , Fatores de Risco , Masculino , Criança , Estudos Retrospectivos , Feminino , Cateterismo Cardíaco/efeitos adversos , Cateterismo Cardíaco/instrumentação , Adulto Jovem , Valor Preditivo dos Testes , Hemodinâmica , Stents , Insuficiência da Valva Pulmonar/fisiopatologia , Insuficiência da Valva Pulmonar/cirurgia , Insuficiência da Valva Pulmonar/diagnóstico por imagem , Insuficiência da Valva Pulmonar/etiologia , Obstrução do Fluxo Ventricular Externo/fisiopatologia , Obstrução do Fluxo Ventricular Externo/etiologia , Obstrução do Fluxo Ventricular Externo/diagnóstico por imagem , Tomada de Decisão Clínica , Adulto
7.
ACS Omega ; 9(7): 7835-7849, 2024 Feb 20.
Artigo em Inglês | MEDLINE | ID: mdl-38405514

RESUMO

Most heavy metals are harmful to human health and the environment, even at extremely low concentrations. In natural waters, they are usually found only in trace amounts. Researchers are paying great attention to nanotechnology and nanomaterials as viable solutions to the problem of water pollution. This research focuses on the synthesis of organic thiophene derivatives that can be used as grafted ligands on the surface of silica-coated iron oxide nanoparticles to remove Cr(VI) chromium ions from water. The Vilsmeier-Haack reaction allows the formation of aldehyde groups in thiophene derivatives, and the resulting products were characterized by the FT-IR, NMR, and GC-MS. Schiff base is used as a binder between organic compounds and nanoparticles by the reaction of aldehyde groups in thiophene derivatives and amine groups on the surface of coated iron oxide nanoparticles. Schiff base functionalized Fe3O4 composites (MNPs@SiO2-SB-THCA) and (MNPs@SiO2-SB-THCTA) were successfully synthesized by homogeneous and heterogeneous methods and characterized by a combination of FT-IR, transmission electron microscopy, X-ray photoelectron spectroscopy, and thermogravimetric analysis. The adsorption studies, kinetic modeling, adsorption isotherms, and thermodynamics of the two materials, MNPs@SiO2-SB-THCA and MNPs@SiO2-SB-THCTA, were investigated for the removal of Cr(VI) from water at room temperature and at 50 mg/L. The high adsorption capacity at pH 6 for MNPs@SiO2-SB-THCTA was 15.53 mg/g, and for MNPs@SiO2-SB-THCA, it was 14.31 mg/g.

8.
Chest ; 165(1): 192-201, 2024 01.
Artigo em Inglês | MEDLINE | ID: mdl-38199732

RESUMO

Pulmonary embolism is increasing in prevalence among pediatric patients; although still rare, it can create a significant risk for morbidity and death within the pediatric patient population. Pulmonary embolism presents in various ways depending on the patient, the size of the embolism, and the comorbidities. Treatment decisions are often driven by the severity of the presentation and hemodynamic effects; severe presentations require more invasive and aggressive treatment. We describe the development and implementation of a pediatric pulmonary embolism response team designed to facilitate rapid, multidisciplinary, data-driven treatment decisions and management.


Assuntos
Equipe de Assistência ao Paciente , Embolia Pulmonar , Criança , Humanos , Embolia Pulmonar/diagnóstico , Embolia Pulmonar/terapia
9.
Artigo em Inglês | MEDLINE | ID: mdl-38199293

RESUMO

OBJECTIVE: To describe clinical, functional, surgical, and outcomes data in pediatric patients with a myocardial bridge (MB) evaluated and managed following a standardized approach. METHODS: Prospective observational study included patients evaluated in the Coronary Artery Anomalies Program. Anatomy was determined by computed tomography angiography, myocardial perfusion by stress perfusion imaging, and coronary hemodynamic assessment by cardiac catheterization. RESULTS: In total, 39 of 42 patients with a complete evaluation for MB were included (December 2012 to June 2022) at a median age of 14.1 years (interquartile range, 12.2-16.4). Sudden cardiac arrest occurred in 3 of 39 (8%), exertional symptoms in 14 (36%), and no/nonspecific symptoms in 7 (18%) patients. Exercise stress test was abnormal in 3 of 34 (9%), stress perfusion imaging in 8 of 34 (24%), and resting instantaneous wave-free ratio ≤0.89 or diastolic dobutamine fractional flow reserve ≤0.80 in 11 of 21 (52%) patients. As a result, 15 of 39 (38%) patients were determined to have hemodynamically significant MB, 1 of 15 patients started beta-blocker, and 14 of 15 were referred for surgery. Myotomy (n = 11) and coronary bypass (n = 1) were performed successfully, resulting in improved symptoms and stress testing results. One patient required pericardiocentesis postoperatively, and all were discharged without other complications. At median follow-up time of 2.9 (1.8-5.8) years, all (except 2 pending surgery) were doing well without exercise restriction. CONCLUSIONS: Pediatric patients with MB can present with myocardial ischemia and sudden cardiac arrest. Provocative stress test and intracoronary hemodynamic tests helped risk-stratify symptomatic patients with MB and concern for ischemia. Surgical repair was safe and effective in mitigating exertional symptoms and stress test results, allowing patients to return to exercise without restriction.

10.
Rev Esp Anestesiol Reanim (Engl Ed) ; 71(2): 129-133, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37683977

RESUMO

Kounis syndrome is defined as cardiovascular symptoms that occur secondary to allergic or hypersensitivity insults, and is also called allergic angina and allergic myocardial infarction. We report a case of pre-operative ceftriaxone-induced Kounis syndrome with no evident dermatological manifestation, and describe our diagnostic dilemma. The patient was symptomatically managed and discharged in stable condition with a warning against future use of ceftriaxone.


Assuntos
Síndrome de Kounis , Doenças Vasculares , Humanos , Síndrome de Kounis/etiologia , Síndrome de Kounis/diagnóstico , Ceftriaxona/efeitos adversos , Doenças Vasculares/complicações
11.
Braz. j. biol ; 842024.
Artigo em Inglês | LILACS-Express | LILACS, VETINDEX | ID: biblio-1469282

RESUMO

Abstract Lactobacilli are probiotics with Aflatoxin (AF) detoxification ability, found in fermented products, GIT of animals and environment. Purpose of this study was to investigate the ability of broiler isolates of Lactobacillus against Aflatoxin B1 (AFB1). For this purpose, 5 isolates of Lactobacillus from broiler gut were incubated with 100 ppb AFB1 in aqueous environment and effect of different parameters (cell fractions, time, temperature, pH) on detoxification was determined by HPLC. The ameliorative effect of Lactobacillus salivarius (LS) against AFB1 was studied in broiler. The results revealed that LS (CR. 4) showed the best results (in vitro) as compared to other isolates (L. salivarius (CR. 3, CR, 4), L. agilis (CE. 2.1, CE. 3.1) and L. crispatus (CE. 28). Cell debris of CR. 4 showed significantly higher detoxification (P 0.05). Maximum amount of AFB1 was detoxified at 30°C (97%), pH 4.0 (99%) and 6 h (99.97%). In vivo study showed that AFB1 decreased weight gain (1,269 ± 0.04 gm/ bird), feed consumed (2,161 ± 0.08 gm/ bird), serum total protein (2.42 ± 0.34 gm/ dl), serum albumin (0.5 ± 0.2 2 gm/dl) and antibody titer (4.2 ± 0.83). Liver function enzymes were found (alanine transaminase (ALT): 32 ± 10.7 U/L) and aspartate transaminase (AST): 314.8 ± 27 U/L) elevated in AFB1 fed broilers. Treatment with 1% LS not only decreased the toxic effects of AFB1 (group D) but also improved the overall health of broilers due to its probiotic effects (p 0.05) as compared to control negative (group A). The detoxification ability of LS was better than commercial binder (CB) (0.2% Protmyc). It was concluded that detoxification of AFB1 by Lactobacillus was strain, temperature, pH and time dependent. LS has detoxification ability against AFB1 in vivo.


Resumo Os lactobacilos são probióticos com capacidade de desintoxicação da Aflatoxina (AF), encontrados em produtos fermentados, TGI de animais e meio ambiente. O objetivo deste estudo foi investigar a capacidade de isolados de frango de corte de Lactobacillus contra a Aflatoxina B1 (AFB1). Para tanto, 5 isolados de Lactobacillus de intestino de frango foram incubados com 100 ppb AFB1 em meio aquoso, e o efeito de diferentes parâmetros (frações celulares, tempo, temperatura, pH) na desintoxicação foi determinado por CLAE. O efeito melhorador de Lactobacillus salivarius (LS) contra AFB1 foi estudado em frangos de corte. Os resultados revelaram que LS (CR. 4) apresentou os melhores resultados (in vitro) em comparação com outros isolados [L. salivarius (CR. 3, CR. 4), L. agilis (CE. 2.1, CE. 3.1) e L. crispatus (CE. 28)]. Detritos celulares de CR. 4 mostraram desintoxicação significativamente maior (P 0.05). A quantidade máxima de AFB1 foi desintoxicada a 30 °C (97%), pH 4.0 (99%) e 6 h (99,97%). O estudo in vivo mostrou que AFB1 diminuiu o ganho de peso (1,269 ± 0.04 g / ave), alimento consumido (2,161 ± 0.08 g / ave), proteína total sérica (2.42 ± 0.34 g / dl), albumina sérica (0.5 ± 0.22 gm / dl) e título de anticorpo (4.2 ± 0.83). As enzimas da função hepática foram encontradas (alanina transaminase (ALT): 32 ± 10.7 U / L) e aspartato transaminase (AST): 314.8 ± 27 U / L) elevadas em AFB1 alimentados com frangos. O tratamento com 1% LS não só diminuiu os efeitos tóxicos de AFB1 (grupo D), mas também melhorou a saúde geral dos frangos devido aos seus efeitos probióticos (p 0.05) em comparação com o controle negativo (grupo A). A capacidade de desintoxicação do LS foi melhor do que o aglutinante comercial (CB) (0.2% Protmyc). Concluiu-se que a desintoxicação de AFB1 por Lactobacillus foi dependente da cepa, temperatura, pH e tempo. LS tem capacidade de desintoxicação contra AFB1 in vivo.

12.
Braz. j. biol ; 84: e250517, 2024. tab, graf
Artigo em Inglês | LILACS, VETINDEX | ID: biblio-1355859

RESUMO

Abstract Lactobacilli are probiotics with Aflatoxin (AF) detoxification ability, found in fermented products, GIT of animals and environment. Purpose of this study was to investigate the ability of broiler isolates of Lactobacillus against Aflatoxin B1 (AFB1). For this purpose, 5 isolates of Lactobacillus from broiler gut were incubated with 100 ppb AFB1 in aqueous environment and effect of different parameters (cell fractions, time, temperature, pH) on detoxification was determined by HPLC. The ameliorative effect of Lactobacillus salivarius (LS) against AFB1 was studied in broiler. The results revealed that LS (CR. 4) showed the best results (in vitro) as compared to other isolates (L. salivarius (CR. 3, CR, 4), L. agilis (CE. 2.1, CE. 3.1) and L. crispatus (CE. 28). Cell debris of CR. 4 showed significantly higher detoxification (P<0.05). Maximum amount of AFB1 was detoxified at 30°C (97%), pH 4.0 (99%) and 6 h (99.97%). In vivo study showed that AFB1 decreased weight gain (1,269 ± 0.04 gm/ bird), feed consumed (2,161 ± 0.08 gm/ bird), serum total protein (2.42 ± 0.34 gm/ dl), serum albumin (0.5 ± 0.2 2 gm/dl) and antibody titer (4.2 ± 0.83). Liver function enzymes were found (alanine transaminase (ALT): 32 ± 10.7 U/L) and aspartate transaminase (AST): 314.8 ± 27 U/L) elevated in AFB1 fed broilers. Treatment with 1% LS not only decreased the toxic effects of AFB1 (group D) but also improved the overall health of broilers due to its probiotic effects (p<0.05) as compared to control negative (group A). The detoxification ability of LS was better than commercial binder (CB) (0.2% Protmyc). It was concluded that detoxification of AFB1 by Lactobacillus was strain, temperature, pH and time dependent. LS has detoxification ability against AFB1 in vivo.


Resumo Os lactobacilos são probióticos com capacidade de desintoxicação da Aflatoxina (AF), encontrados em produtos fermentados, TGI de animais e meio ambiente. O objetivo deste estudo foi investigar a capacidade de isolados de frango de corte de Lactobacillus contra a Aflatoxina B1 (AFB1). Para tanto, 5 isolados de Lactobacillus de intestino de frango foram incubados com 100 ppb AFB1 em meio aquoso, e o efeito de diferentes parâmetros (frações celulares, tempo, temperatura, pH) na desintoxicação foi determinado por CLAE. O efeito melhorador de Lactobacillus salivarius (LS) contra AFB1 foi estudado em frangos de corte. Os resultados revelaram que LS (CR. 4) apresentou os melhores resultados (in vitro) em comparação com outros isolados [L. salivarius (CR. 3, CR. 4), L. agilis (CE. 2.1, CE. 3.1) e L. crispatus (CE. 28)]. Detritos celulares de CR. 4 mostraram desintoxicação significativamente maior (P < 0.05). A quantidade máxima de AFB1 foi desintoxicada a 30 °C (97%), pH 4.0 (99%) e 6 h (99,97%). O estudo in vivo mostrou que AFB1 diminuiu o ganho de peso (1,269 ± 0.04 g / ave), alimento consumido (2,161 ± 0.08 g / ave), proteína total sérica (2.42 ± 0.34 g / dl), albumina sérica (0.5 ± 0.22 gm / dl) e título de anticorpo (4.2 ± 0.83). As enzimas da função hepática foram encontradas (alanina transaminase (ALT): 32 ± 10.7 U / L) e aspartato transaminase (AST): 314.8 ± 27 U / L) elevadas em AFB1 alimentados com frangos. O tratamento com 1% LS não só diminuiu os efeitos tóxicos de AFB1 (grupo D), mas também melhorou a saúde geral dos frangos devido aos seus efeitos probióticos (p < 0.05) em comparação com o controle negativo (grupo A). A capacidade de desintoxicação do LS foi melhor do que o aglutinante comercial (CB) (0.2% Protmyc). Concluiu-se que a desintoxicação de AFB1 por Lactobacillus foi dependente da cepa, temperatura, pH e tempo. LS tem capacidade de desintoxicação contra AFB1 in vivo.


Assuntos
Animais , Aflatoxina B1/análise , Aflatoxina B1/toxicidade , Probióticos , Galinhas , Lactobacillus , Ração Animal/análise
13.
J Thorac Dis ; 15(11): 6192-6204, 2023 Nov 30.
Artigo em Inglês | MEDLINE | ID: mdl-38090288

RESUMO

Background: Congenital heart disease (CHD) is one of the most common birth defects and consumes a substantial amount of health care resources. CHD leads to heavy economic burdens for families. However, there are limited data regarding the utilization of healthcare resources for CHD. The objectives of this study were to evaluate the composition, changing trends, and factors affecting hospitalization costs for patients with CHD in the western highlands area of China over a 10-year period. Methods: We conducted a study using the International Quality Improvement Collaborative for Congenital Heart Surgery (IQIC) database and information management system of The First Hospital of Lanzhou University between January 2010 and December 2019. Results: Among 3,087 patients hospitalized for CHD surgery, annual CHD hospitalization costs saw an increasing trend over the 10-year period, with an average growth rate of 4.6% per year. The major contributors to the hospitalization costs were surgery, surgical material, and drug costs. Length of stay (ß=0.203; 0.379; 0.474, P<0.01), age at hospitalization (ß=0.293, P<0.01), proportion of surgery (ß=0.090; -0.102; -0.122; -0.110, P<0.01) and drug costs (ß=-0.114; -0.147; -0.069, P<0.01), and use of traditional Chinese medicine (ß=0.141, P<0.01) were independent factors affecting average hospitalization costs. Conclusions: The financial burden of patients with CHD in the Chinese western highland region is high. Independent of inflation, CHD hospitalization costs are increasing. Measures taken by medical institutions to control the increase in drug costs, and to shorten the length of stay may be expected to have positive effects on reducing the financial burden of individuals with CHD and their families.

14.
JACC Case Rep ; 26: 102058, 2023 Nov 15.
Artigo em Inglês | MEDLINE | ID: mdl-38094173

RESUMO

The removal of balloon fragments from the pulmonary artery without damaging the pulmonary and tricuspid valves can be difficult. Four cases during transcatheter pulmonary valve replacement are described in which a novel retrieval system was used to facilitate safe removal. (Level of Difficulty: Advanced.).

15.
J Am Heart Assoc ; 12(23): e030575, 2023 Dec 05.
Artigo em Inglês | MEDLINE | ID: mdl-38038172

RESUMO

BACKGROUND: The modified Blalock-Taussig-Thomas shunt is the gold standard palliation for securing pulmonary blood flow in infants with ductal-dependent pulmonary blood flow. Recently, the ductus arteriosus stent (DAS) has become a viable alternative. METHODS AND RESULTS: This was a retrospective multicenter study of neonates ≤30 days undergoing DAS or Blalock-Taussig-Thomas shunt placement between January 1, 2017 and December 31, 2020 at hospitals reporting to the Pediatric Health Information Systems database. We performed generalized linear mixed-effects modeling to evaluate trends in intervention and intercenter variation, propensity score adjustment and inverse probability weighting with linear mixed-effects modeling to analyze length of stay and cost of hospitalization, and generalized linear mixed modeling to analyze differences in 30-day outcomes. There were 1874 subjects (58% male, 61% White) from 45 centers (29% DAS). Odds of DAS increased with time (odds ratio [OR] 1.23, annually, P<0.01 [95% CI, 1.10-1.38]) with significant intercenter variation (median OR, 3.81 [95% CI, 2.74-5.91]). DAS was associated with shorter hospital length of stay (ratio of geometric means, 0.76 [95% CI, 0.63-0.91]), shorter intensive care unit length of stay (ratio of geometric means, 0.77 [95% CI, 0.61-0.97]), and less expensive hospitalization (ratio of geometric means, 0.70 [95% CI, 0.56-0.87]). Intervention was not significantly associated with odds of 30-day transplant-free survival (OR,1.18 [95% CI, 0.70-1.99]) or freedom from catheter reintervention (OR, 1.02 [95% CI, 0.65-1.58]), but DAS was associated with 30-day freedom from composite adverse outcome (OR, 1.51 [95% CI, 1.11-2.05]). CONCLUSIONS: Use of DAS is increasing, but there is variability across centers. Though odds of transplant-free survival and reintervention were not significantly different after DAS, and DAS was associated with shorter length of stay and lower in-hospital costs.


Assuntos
Procedimento de Blalock-Taussig , Permeabilidade do Canal Arterial , Canal Arterial , Sistemas de Informação em Saúde , Feminino , Humanos , Lactente , Recém-Nascido , Masculino , Procedimento de Blalock-Taussig/efeitos adversos , Permeabilidade do Canal Arterial/cirurgia , Permeabilidade do Canal Arterial/etiologia , Tempo de Internação , Cuidados Paliativos/métodos , Artéria Pulmonar , Circulação Pulmonar , Estudos Retrospectivos , Stents , Resultado do Tratamento
16.
Anesth Analg ; 2023 Dec 21.
Artigo em Inglês | MEDLINE | ID: mdl-38127663

RESUMO

BACKGROUND: Anesthesiology experts advocate for formal education in maternal critical care, including the use of focused cardiac ultrasound (FCU) in high-acuity obstetric units. While benefits and feasibility of FCU performed by experts have been well documented, little evidence exists on the feasibility of FCU acquired by examiners with limited experience. The primary aim of this study was to assess how often echocardiographic images of sufficient quality to guide clinical decision-making were attained by trainees with limited experience performing FCU in term parturients undergoing cesarean delivery (CD). METHODS: In this prospective cohort study, healthy term parturients (American Society of Anesthesiologists [ASA] ≤ 3, ≥37 weeks of gestation) with singleton pregnancy, body mass index (BMI) <40 kg/m2, and no history of congenital and acquired cardiac disease undergoing scheduled, elective CD were recruited by a trainee. After undergoing standardized training, including an 8-hour online E-learning module, a 1-day hands-on FCU course, and 20 to 30 supervised scans until the trainee was assessed competent in image acquisition, 8 trainees with limited FCU experience performed apical 4-chamber (A4CH), parasternal long-axis (PLAX), and short-axis (PSAX) view preoperatively after spinal anesthesia (SPA) and intraoperatively after neonatal delivery (ND). Obtained FCU images were graded 1 to 5 by 2 blinded instructors (1 = no image to 5 = perfect image obtainable; ≥3 defined as image quality sufficient for clinical decision-making). RESULTS: Following the screening of 95 women, 8 trainees with limited FCU experience each performed a median of 5 [3-8] FCUs in a total of 64 women. Images of sufficient quality were obtainable in 61 (95.3 %) and 57 (89.1 %) of women after SPA and ND, respectively. FCU images of perfect image quality were obtainable in 9 (14.1 %) and 7 (10.9 %) women preoperatively after SPA and intraoperatively after ND, respectively. A PLAX, PSAX, and A4CH view with grade ≥3 was obtained in 53 (82.8 %), 58 (90.6 %) and 40 (62.5 %) of women preoperatively after SPA and in 50 (78.1 %), 49 (76.6 %), and 29 (45.3 %) of women intraoperatively after ND. Left ventricular function could be assessed in 39 of 40 women (97.5 %) preoperatively after SPA and 39 of 40 (97.5%) intraoperatively after ND. Right ventricular function could be assessed in 31 of 40 (77.5 %) after SPA and in 23 of 40 (59%) after ND. We observed a difference in image grading between different trainees in the AP4CH-view (P = .0001). No difference in image grading was found between preoperative and intraoperative FCUs. CONCLUSIONS: FCU is feasible in the parturient undergoing CD and images of sufficient quality for clinical decision-making were obtained by trainees with limited experience in almost all parturients. Image acquisition and quality in the A4CH view may be impacted by the individual trainee performing the FCU.

17.
J Invasive Cardiol ; 35(11)2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37992333

RESUMO

BACKGROUND: The data on the use of Gore Cardioform Septal Occluder (GCA; W. L. Gore and Associates, Inc.) for atrial septal defect (ASD) with deficient rims is limited. METHODS: All patients evaluated by transesophageal echocardiogram (TEE) for ASD occlusion were included. TEE planes at 35°, 0°, and 90° were assessed for anterior-superior (AS) and posterior (P), anterior-inferior (AI) and posterior-superior (PS), as well as superior (S) and inferior (I) rims. ASD size >20 mm, and rims less than 5 mm were defined as large and deficient, respectively. We included patients who had a procedural failure along with the patients in whom the procedure was not attempted after echocardiogram in the unsuccessful group. RESULTS: In 148 patients, the median weight, age, and ASD size were 36 kg (range, 8-60 kg), 11.8 years (range, 1-60 years), and 14.2 ± 8.28 mm, respectively. One or more deficient rims were noted in 112 of 148 (75.7%): 99 (67%) AS, 36 (24%) P, 17 (11%) AI, 30 (20%) PS, 26 (18%) S, and 33 (22%) I. ASD closure was performed in 115 (78%) patients. The procedure was successful in 111 (96.5%) patients with procedural failure in 4 (3.4%) patients. Multiple deficient rims were associated with reduced procedural success (OR 0.36, 95% CI, 0.25-0.56). On multivariate analysis deficient P, PS, and I rims were associated with an unsuccessful group (P = .001, .046, and .005, respectively). Complications included 1 device embolization, 1 vascular injury, and 5 arrhythmias. CONCLUSIONS: Transcatheter closure of ASDs with deficient rims is feasible using GCA. Large ASDs with deficient P, PS, and I rims were associated with unsuccessful closure. Risk stratification and comprehensive evaluation of ASD rims is vital for the use of GCA.


Assuntos
Comunicação Interatrial , Dispositivo para Oclusão Septal , Humanos , Cateterismo Cardíaco , Comunicação Interatrial/diagnóstico , Comunicação Interatrial/cirurgia , Ecocardiografia Transesofagiana , Ecocardiografia , Arritmias Cardíacas , Resultado do Tratamento
20.
Tissue Cell ; 85: 102239, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37865037

RESUMO

BACKGROUND: Toxic cardiomyopathies were a potentially fatal adverse effect of anthracycline therapy. AIM: This study was conducted to demonstrate the pathogenetic, morphologic, and toxicologic effects of doxorubicin on the heart and to investigate how the MAPK /TNF-α pathway can be modulated to improve doxorubicin-Induced cardiac lesions using bone marrow-derived mesenchymal stem cells (BM-MSCs) and olive leaf extract (OLE). METHODS: During the study, 40 adult male rats were used. Ten were used to donate MSCs, and the other 30 were split into 5 equal groups: Group I was the negative control, Group II obtained oral OLE, Group III obtained an intraperitoneal cumulative dose of DOX (12 mg/kg) in 6 equal doses of 2 mg/kg every 48 h for 12 days, Group IV obtained intraperitoneal DOX and oral OLE at the same time, and Group V obtained intraperitoneal DOX and BM-MSCs through the tail vein at the same time for 12 days. Four weeks after their last dose of DOX, the rats were euthanized. By checking the bioinformatic databases, a molecularly targeted path was selected. Then the histological, immunohistochemistry, and gene expression of ERK, JNK, NF-κB, IL-6, and TNF-α were done. RESULTS: Myocardial immunohistochemistry revealed severe fibrosis, cell degeneration, increased vimentin, and decreased CD-31 expression in the DOX-treated group, along with a marked shift in morphometric measurements, a disordered ultrastructure, and overexpression of inflammatory genes (ERK, NF-κB, IL-6, and TNF-α), oxidative stress markers, and cardiac biomarkers. Both groups IV and V displayed reduced cardiac fibrosis or inflammation, restoration of the microstructure and ultrastructure of the myocardium, downregulation of inflammatory genes, markers of oxidative stress, and cardiac biomarkers, a notable decline in vimentin, and an uptick in CD-31 expression. In contrast to group IV, group V showed a considerable beneficial effect. CONCLUSION: Both OLE and BM-MSCs showed an ameliorating effect in rat models of DOX-induced cardiotoxicity, with BM-MSCs showing a greater influence than OLE.


Assuntos
Cardiotoxicidade , Células-Tronco Mesenquimais , Ratos , Masculino , Animais , Cardiotoxicidade/metabolismo , Fator de Necrose Tumoral alfa/metabolismo , Vimentina/metabolismo , NF-kappa B/metabolismo , Interleucina-6/metabolismo , Doxorrubicina/toxicidade , Estresse Oxidativo , Células-Tronco Mesenquimais/metabolismo , Biomarcadores/metabolismo , Apoptose
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA