Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
1.
PLoS One ; 18(2): e0282222, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-36827336

RESUMO

BACKGROUND: Prescription opioid use has increased steadily in many Western countries over the past two decades, most notably in the US, Canada, and most European countries, including the Netherlands. Especially the increasing use of prescription opioids for chronic non-cancer pain has raised concerns. Most opioids in the Netherlands are prescribed in general practices. However, little is known about variation in opioid prescribing between general practices. To better understand this, we investigated practice variation in opioid prescribing for non-cancer pain between Dutch general practices. METHODS: Data from 2017-2019 of approximately 10% of all Dutch general practices was used. Each year included approximately 1000000 patients distributed over approximately 380 practices. The primary outcome was the proportion of patients with chronic (>90 days) high-dose (≥90 oral morphine equivalents) opioid prescriptions. The secondary outcome was the proportion of patients with chronic (<90 oral morphine equivalents) opioid prescriptions. Practice variation was expressed as the ratio of the 95th/5th percentiles and the ratio of mean top 10/bottom 10. Funnel plots were used to identify outliers. Potential factors associated with unwarranted variation were investigated by comparing outliers on practice size, patient neighbourhood socioeconomic status, and urbanicity. RESULTS: Results were similar across all years. The magnitude of variation for chronic high-dose opioid prescriptions in 2019 was 7.51-fold (95%/5% ratio), and 15.1-fold (top 10/bottom 10 ratio). The percentage of outliers in the funnel plots varied between 13.8% and 21.7%. Practices with high chronic high-dose opioid prescription proportions were larger, and had more patients from lower income and densely populated areas. CONCLUSIONS: There might be unwarranted practice variation in chronic high-dose opioid prescriptions in primary care, pointing at possible inappropriate use of opioids. This appears to be related to socioeconomic status, urbanicity, and practice size. Further investigation of the factors driving practice variation can provide target points for quality improvement and reduce inappropriate care and unwarranted variation.


Assuntos
Analgésicos Opioides , Dor Crônica , Humanos , Analgésicos Opioides/uso terapêutico , Estudos Retrospectivos , Padrões de Prática Médica , Dor Crônica/tratamento farmacológico , Morfina/uso terapêutico , Prescrições de Medicamentos , Atenção Primária à Saúde
2.
Fam Cancer ; 22(2): 177-186, 2023 04.
Artigo em Inglês | MEDLINE | ID: mdl-36401146

RESUMO

To prevent duodenal and ampullary cancer in familial adenomatous polyposis (FAP) patients, a diagnosis of high grade dysplasia (HGD) plays an important role in the clinical management. Previous research showed that FAP patients are both over- and undertreated after a misdiagnosis of HGD, indicating unwarranted variation. We aimed to investigate the laboratory variation in dysplasia grading of duodenal adenomas and explore possible explanations for this variation. We included data from all Dutch pathology laboratories between 1991 and 2020 by retrieving histology reports from upper endoscopy specimens of FAP patients from the Dutch nationwide pathology databank (PALGA). Laboratory variation was investigated by comparing standardized proportions of HGD. To describe the degree of variation between the laboratories a factor score was calculated. A funnel plot was used to identify outliers. A total of 3050 specimens from 25 laboratories were included in the final analyses. The mean observed HGD proportion was 9.4%. The top three HGD-diagnosing laboratories diagnosed HGD 3.9 times more often than the lowest three laboratories, even after correcting for case-mix. No outliers were identified. Moderate laboratory variation was found in HGD diagnoses of duodenal tissue of FAP patients after adjusting for case-mix. Despite the fact that no outliers were observed, there may well be room for quality improvement. Concentration of these patients in expertise centers may decrease variation. To further reduce unwarranted variation, we recommend (inter)national guidelines to become more uniform in their recommendations regarding duodenal tissue sampling and consequences of HGD diagnoses.


Assuntos
Adenoma , Polipose Adenomatosa do Colo , Ampola Hepatopancreática , Neoplasias do Ducto Colédoco , Neoplasias Duodenais , Humanos , Ampola Hepatopancreática/patologia , Laboratórios , Polipose Adenomatosa do Colo/diagnóstico , Adenoma/patologia , Neoplasias Duodenais/patologia
3.
Vox Sang ; 109(1): 25-34, 2015 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-25854417

RESUMO

BACKGROUND AND OBJECTIVES: Increased iron and metabolic syndrome (MetS) go hand in hand. Frequent blood donation depletes iron stores. This study investigates whether high-intensity blood donation is associated with lower MetS prevalence compared with low-intensity blood donation, and whether iron acts as an intermediary factor. MATERIALS AND METHODS: A random sample of 422 male and 211 female active whole-blood donors ≥45 years of age was included in a cross-sectional study. Lipids, glucose and iron parameters were measured after overnight fasting. MetS was defined according to the joint interim statement of the International Diabetes Federation Task Force on Epidemiology and Prevention. Three groups of donation intensity were created by sex-specific tertiles of donation frequency per year and duration of donor career. RESULTS: MetS was present in 22·9% of donors. Prevalence of MetS was 1·46 (95% confidence interval [CI]: 0·93-2·30) times higher in men with high donation intensity, whereas in women MetS prevalence was 2·14 (95% CI: 0·94-4·86) times higher in donors with high donation intensity compared with those with low donation intensity. In men, increased prevalence of MetS was mainly associated with higher ferritin, whereas high hepcidin predominantly affected MetS prevalence in women. CONCLUSION: High-intensity blood donation is not associated with a decreased prevalence of MetS. In men and women, different iron parameters are associated with MetS prevalence. The temporal relationship between blood donation, iron and MetS, and gender differences herein need to be explored in future research.


Assuntos
Doadores de Sangue/estatística & dados numéricos , Síndrome Metabólica/epidemiologia , Adulto , Idoso , Estudos Transversais , Feminino , Ferritinas/sangue , Humanos , Ferro/sangue , Masculino , Pessoa de Meia-Idade , Prevalência
4.
Vox Sang ; 97(2): 129-38, 2009 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-19508703

RESUMO

BACKGROUND AND OBJECTIVES: Studying the contribution of demographic factors to the donor career provides important knowledge to be used for donor management. The aim of this study is to gain insight into donor characteristics, more specifically into the demographic profile of active vs. resigned donors, and multi-gallon vs. occasional donors. MATERIALS AND METHODS: The study population consisted of all registered Dutch whole-blood donors between 1 January 2004 and 1 January 2005 (N = 370 470). The effect of several blood donor characteristics and demographic variables on (i) resigning donating and (ii) being a multi-gallon donor were assessed. Blood donor characteristics were extracted from the blood bank information system and included age, sex, blood group, number of donations and invitations. Demographic characteristics were constituted by population data on urbanization level, socio-economic status (income, housing value), and ethnicity. RESULTS: Men clearly resigned less often than women (odds ratio (OR) 0.73, 95% confidence interval (CI) 0.72-0.75). Being older than 24 years, having a high income, a high-priced house, living in less urbanized areas or areas with relatively few ethnically diverse people also reduced the stopping risk. With respect to multi-gallon donorship, men were five times more often multi-gallon donor than women (OR 5.27, 95% CI 5.15-5.39) irrespective of the number of donation invitations. Furthermore, multi-gallon donors appeared to live in urbanized areas and have a higher income than occasional donors. CONCLUSION: Our results show that different donor profiles can be distinguished. Differences between active and resigned donors include age, the number of donations, sex, socio-economic-status, ethnicity, and urbanization level. The factors highly associated with being a multi-gallon donor are sex, age, socio-economic status, and to a lesser extent urbanization level. Donor profiles do provide the blood bank with knowledge on their donor population, which may be used as valuable information for donor recruitment and retention policies.


Assuntos
Doadores de Sangue/estatística & dados numéricos , Coleta de Dados , Etnicidade , Feminino , Humanos , Masculino , Países Baixos , Classe Social , Urbanização
5.
J Clin Epidemiol ; 61(6): 572-9, 2008 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-18471661

RESUMO

OBJECTIVE: To assess reproducibility of coronary calcium measurements with Multi Detector-Row Computed Tomography (MDCT) imaging and to evaluate whether different measurement protocols, slice thickness, and cardiovascular risk factors affect inter and intra-observer reproducibility. STUDY DESIGN AND SETTING: In a cross-sectional design, the study population comprised 199 healthy postmenopausal women. Coronary calcium was assessed using a 16-MDCT (Philips Mx 8000 IDT 16). Images were made using 1.5 and 3.0mm slice thicknesses. To assess inter and intra-observer reproducibility, the images were read by two observers. One observer read the images of 52 subjects twice. The Agatston score, a volume, and a mass measurement were used to quantify coronary calcium. Reproducibility was determined by estimation of mean, absolute, and relative differences between scores of the observers and by estimation of intraclass correlation coefficients (ICC). RESULTS: 60.3% participants (n=120) had a positive calcium score. Median Agatston score for the first observer was 2.20 with a range of 0-2,019. The reproducibility of coronary calcium measurements between and within observers was excellent with ICC of >0.95, and small mean, absolute, and relative differences. Reproducibility findings were similar for 1.5mm slices as for 3.0mm slices, and equal for Agatston, volume, and mass measurements. CONCLUSION: Reproducibilility of coronary calcium measurement using MDCT is excellent, irrespective of slice thickness and type of calcium parameter.


Assuntos
Calcinose/diagnóstico por imagem , Doença da Artéria Coronariana/diagnóstico por imagem , Idoso , Doenças Cardiovasculares/etiologia , Angiografia Coronária/métodos , Feminino , Humanos , Pessoa de Meia-Idade , Variações Dependentes do Observador , Reprodutibilidade dos Testes , Fatores de Risco , Tomografia Computadorizada por Raios X/métodos
6.
Eur J Epidemiol ; 22(4): 235-43, 2007.
Artigo em Inglês | MEDLINE | ID: mdl-17427036

RESUMO

PURPOSE: To assess inter-scan reproducibility of coronary calcium measurements obtained from Multi Detector-Row CT (MDCT) images and to evaluate whether this reproducibility is affected by different measurement protocols, slice thickness, cardiovascular risk factors and/or technical variables. DESIGN: Cross-sectional study with repeated measurements. MATERIALS AND METHODS: The study population comprised 76 healthy women. Coronary calcium was assessed in these women twice in one session using 16-MDCT (Philips Mx 8000 IDT 16). Images were reconstructed with 1.5 mm slice thickness and 3.0 mm slice thickness. The 76 repeated scans were scored. The Agatston score, a volume measurement and a mass measurement were assessed. Reproducibility was determined by estimation of mean, absolute, relative difference, the weighted kappa value for agreement and the Intra-class correlation coefficient (ICCC). RESULTS: Fifty-five participants (72.4%) had a coronary calcification of more than zero in Agatston (1.5 mm slice thickness). The reproducibility of coronary calcium measurements between scans in terms of ranking was excellent with Intra-class correlation coefficients of >0.98, and kappa values above 0.80. The absolute difference in calcium score between scans increased with increasing calcium levels, indicating that measurement error increases with increasing calcium levels. However, no relation was found between the mean difference in scores and calcium levels, indicating that the increase in measurement error is likely to result in random misclassification in calcium score. Reproducibility results were similar for 1.5 mm slices and for 3.0 mm slices, and equal for Agatston, volume and mass measurements. CONCLUSION: Inter-scan reproducibilility of measurement of coronary calcium using images from MDCT is excellent, irrespective of slice thickness and type of calcium parameter.


Assuntos
Calcinose/diagnóstico por imagem , Cálcio/análise , Doença da Artéria Coronariana/diagnóstico por imagem , Tomografia Computadorizada por Raios X , Idoso , Angiografia Coronária/métodos , Vasos Coronários , Estudos Transversais , Diagnóstico por Imagem/métodos , Feminino , Humanos , Pessoa de Meia-Idade , Países Baixos , Reprodutibilidade dos Testes
7.
Urology ; 58(3): 367-71, 2001 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-11549482

RESUMO

OBJECTIVES: To study the diagnostic performance of the ImmunoCyt test in patients in follow-up for superficial urothelial cell carcinoma (UCC) of the bladder. METHODS: Voided urine samples were collected from all included patients. Samples were processed with the ImmunoCyt test. The ImmunoCyt slides were scored under a fluorescence microscope by 3 observers. The ImmunoCyt test was considered positive if one or more observers scored the test positive. Urethrocystoscopy (and additional histologic examination in the case of suspicious cystoscopic findings) was used as the reference standard. To investigate the validity of ImmunoCyt, sensitivity, specificity, positive predictive value, negative predictive value, area under the receiver operating characteristic curve, and diagnostic odds ratios were determined. To investigate the reproducibility of ImmunoCyt, kappa values (measure of agreement) were computed. The observers' findings were analyzed in pairs. RESULTS: One hundred four patients in follow-up after primary superficial UCC of the bladder were included. Samples of 18 patients had to be excluded because of low cellularity (ie, insufficient assessable urothelial cells). Tumor recurrence was found in 22 of the remaining 86 patients (17 pTa, 3 pT1, 1 carcinoma in situ, 1 pT2 or higher). The test had a sensitivity of 50%, specificity of 73%, positive predictive value of 39%, and negative predictive value of 81%. The diagnostic odds ratio was 2.8 (95% confidence interval 1.0 to 7.5). The area under the curve for the different observers varied between 0.54 and 0.60. The kappa values were low (0.05 to 0.45), representing high interobserver variability. CONCLUSIONS: The promising results from other studies could not be confirmed in this specific group of patients in follow-up for superficial UCC of the bladder. The validity of ImmunoCyt was insufficient to justify the omission of cystoscopy in patients in follow-up for superficial UCC.


Assuntos
Biomarcadores Tumorais , Carcinoma de Células de Transição/urina , Imuno-Histoquímica/métodos , Neoplasias da Bexiga Urinária/urina , Adulto , Idoso , Carcinoma de Células de Transição/diagnóstico , Intervalos de Confiança , Cistoscopia , Feminino , Imunofluorescência/métodos , Seguimentos , Humanos , Imuno-Histoquímica/estatística & dados numéricos , Masculino , Pessoa de Meia-Idade , Razão de Chances , Valor Preditivo dos Testes , Curva ROC , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Neoplasias da Bexiga Urinária/diagnóstico , Neoplasias da Bexiga Urinária/cirurgia , Urina/citologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA