Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
1.
Sci Rep ; 11(1): 17315, 2021 08 27.
Artigo em Inglês | MEDLINE | ID: mdl-34453096

RESUMO

This study was aimed to compare the vascular healing process of a SYNERGY stent with that of a PROMUS PREMIER stent in patients with acute coronary syndrome (ACS). In 71 patients with ACS, undergoing coronary stent implantation using the SYNERGY stent (n = 52) or PROMUS PREMIER stent (n = 19), we measured circulating CD34+/CD133+/CD45null cells and CD34+/KDR+ cells and observed vascular healing at the stented sites using optical coherence tomography (OCT) and coronary angioscopy. On the day 7, circulating CD34+/CD133+/CD45null cells increased in SYNERGY group (P < 0.0001), while it did not change in PROMUS group. The CD34+/KDR+ cells also increased in SYNERGY group (P < 0.0001) but less significantly in the PROMUS group (P < 0.05). The OCT-based neointimal thickness (P < 0.0005) and neointimal coverage rate (P < 0.05) at 12 months were greater in SYNERGY group, compared with PROMUS group. The coronary angioscopy-based neointimal coverage grade at 12 months was also greater in SYNERGY group (P < 0.001). In overall patients, the change in CD34+/KDR+ cells on the day 7 correlated with the OCT-based neointimal thickness at 12 months (R = 0.288, P < 0.05). SYNERGY stent seems to have potential advantages over PROMUS PREMIER stent for ACS patients in terms of vascular healing process at the stented sites.


Assuntos
Síndrome Coronariana Aguda/terapia , Implantação de Prótese/métodos , Células-Tronco/metabolismo , Cicatrização/efeitos dos fármacos , Idoso , Antígenos CD/metabolismo , Ensaios Clínicos como Assunto , Angiografia Coronária , Vasos Coronários , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Neointima/metabolismo , Stents , Tomografia de Coerência Óptica , Resultado do Tratamento
2.
Int J Cardiovasc Imaging ; 35(11): 1971-1978, 2019 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-31218524

RESUMO

Normalized optical density (NOD) measured by optical coherence tomography represents neointimal maturity after coronary stent implantation and is correlated with morphologic information provided by both light and electron microscopy. We aimed to test the hypothesis that even second generation drug-eluting stents (DESs) are problematic in terms of neointimal maturity. We implanted bare-metal stents (BMS: n = 14), everolimus-eluting stents (EESs: n = 15) or zotarolimus-eluting stents (ZESs: n = 12) at 41 sites in 32 patients with stable coronary artery disease. OCT was performed at up to 12 months of follow-up, and the average optical density of neointima covering struts was evaluated. NOD was calculated as the optical density of stent-strut covering tissue divided by the optical density of the struts. We also measured circulating CD34+ /CD133+ /CD45low cells, and serum levels of stromal cell-derived factor (SDF)-1, interleukin (IL)-8 and matrix metalloproteinase (MMP)-9 at baseline and follow-up. NOD was lower in the EES (0.70 ± 0.06) group than in the BMS (0.76 ± 0.07, P < 0.05) and ZES (0.76 ± 0.06, P < 0.05) groups. The mean neointimal area (R = 0.33, P < 0.05) and mean neointimal thickness (R = 0.37, P < 0.05) were correlated with NOD. Although NOD was not correlated with percent changes in circulating endothelial progenitor cells, and the levels of SDF-1 and IL-8, it was negatively correlated with the change in MMP-9 level (R = - 0.51, P < 0.01). Neointimal maturity might be lower at EES sites than BMS or ZES sites. This might lead to impaired neointimal tissue growth and matrix degradation. These results suggest a specific pathophysiology after DES implantation.


Assuntos
Doença da Artéria Coronariana/terapia , Vasos Coronários/diagnóstico por imagem , Stents Farmacológicos , Neointima , Intervenção Coronária Percutânea/instrumentação , Tomografia de Coerência Óptica , Idoso , Idoso de 80 Anos ou mais , Fármacos Cardiovasculares/administração & dosagem , Quimiocina CXCL12/sangue , Doença da Artéria Coronariana/sangue , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/fisiopatologia , Vasos Coronários/metabolismo , Vasos Coronários/fisiopatologia , Células Progenitoras Endoteliais/metabolismo , Células Progenitoras Endoteliais/patologia , Everolimo/administração & dosagem , Feminino , Humanos , Interleucina-8/sangue , Masculino , Metaloproteinase 9 da Matriz/sangue , Pessoa de Meia-Idade , Intervenção Coronária Percutânea/efeitos adversos , Valor Preditivo dos Testes , Desenho de Prótese , Sirolimo/administração & dosagem , Sirolimo/análogos & derivados , Fatores de Tempo , Resultado do Tratamento , Remodelação Vascular
3.
J Am Coll Cardiol ; 70(22): 2752-2763, 2017 Dec 05.
Artigo em Inglês | MEDLINE | ID: mdl-29191323

RESUMO

BACKGROUND: Limited data exist about safety and efficacy of transcatheter aortic valve replacement (TAVR) in patients with pure native aortic regurgitation (AR). OBJECTIVES: This study sought to compare the outcomes of TAVR with early- and new-generation devices in symptomatic patients with pure native AR. METHODS: From the pure native AR TAVR multicenter registry, procedural and clinical outcomes were assessed according to VARC-2 criteria and compared between early- and new-generation devices. RESULTS: A total of 331 patients with a mean STS score of 6.7 ± 6.7 underwent TAVR. The early- and new-generation devices were used in 119 patients (36.0%) and 212 patients (64.0%), respectively. STS score tended to be lower in the new-generation device group (6.2 ± 6.7 vs. 7.6 ± 6.7; p = 0.08), but transfemoral access was more frequently used in the early-generation device group (87.4% vs. 60.8%; p < 0.001). Compared with the early-generation devices, the new-generation devices were associated with a significantly higher device success rate (81.1% vs. 61.3%; p < 0.001) due to lower rates of second valve implantation (12.7% vs. 24.4%; p = 0.007) and post-procedural AR ≥ moderate (4.2% vs. 18.8%; p < 0.001). There were no significant differences in major 30-day endpoints between the 2 groups. The cumulative rates of all-cause and cardiovascular death at 1-year follow-up were 24.1% and 15.6%, respectively. The 1-year all-cause mortality rate was significantly higher in the patients with post-procedural AR ≥ moderate compared with those with post-procedural AR ≤ mild (46.1% vs. 21.8%; log-rank p = 0.001). On multivariable analysis, post-procedural AR ≥ moderate was independently associated with 1-year all-cause mortality (hazard ratio: 2.85; 95% confidence interval: 1.52 to 5.35; p = 0.001). CONCLUSIONS: Compared with the early-generation devices, TAVR using the new-generation devices was associated with improved procedural outcomes in treating patients with pure native AR. In patients with pure native AR, significant post-procedural AR was independently associated with increased mortality.


Assuntos
Insuficiência da Valva Aórtica , Valva Aórtica/cirurgia , Artéria Femoral/cirurgia , Próteses Valvulares Cardíacas , Complicações Pós-Operatórias , Substituição da Valva Aórtica Transcateter , Idoso , Idoso de 80 Anos ou mais , Insuficiência da Valva Aórtica/diagnóstico , Insuficiência da Valva Aórtica/mortalidade , Insuficiência da Valva Aórtica/cirurgia , Cateterismo Periférico/métodos , Cateterismo Periférico/estatística & dados numéricos , Feminino , Próteses Valvulares Cardíacas/efeitos adversos , Próteses Valvulares Cardíacas/normas , Humanos , Cooperação Internacional , Masculino , Mortalidade , Avaliação de Processos e Resultados em Cuidados de Saúde , Complicações Pós-Operatórias/diagnóstico , Complicações Pós-Operatórias/epidemiologia , Desenho de Prótese/tendências , Melhoria de Qualidade , Sistema de Registros/estatística & dados numéricos , Medição de Risco , Índice de Gravidade de Doença , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/instrumentação , Substituição da Valva Aórtica Transcateter/métodos , Substituição da Valva Aórtica Transcateter/estatística & dados numéricos
4.
J Am Coll Cardiol ; 70(9): 1121-1131, 2017 Aug 29.
Artigo em Inglês | MEDLINE | ID: mdl-28838360

RESUMO

BACKGROUND: Limited data exist regarding transcatheter mitral valve replacement (TMVR) for patients with failed mitral valve replacement and repair. OBJECTIVES: This study sought to evaluate the outcomes of TMVR in patients with failed mitral bioprosthetic valves (valve-in-valve [ViV]) and annuloplasty rings (valve-in-ring [ViR]). METHODS: From the TMVR multicenter registry, procedural and clinical outcomes of mitral ViV and ViR were compared according to Mitral Valve Academic Research Consortium criteria. RESULTS: A total of 248 patients with mean Society of Thoracic Surgeons score of 8.9 ± 6.8% underwent TMVR. Transseptal access and the balloon-expandable valve were used in 33.1% and 89.9%, respectively. Compared with 176 patients undergoing ViV, 72 patients undergoing ViR had lower left ventricular ejection fraction (45.6 ± 17.4% vs. 55.3 ± 11.1%; p < 0.001). Overall technical and device success rates were acceptable, at 92.3% and 85.5%, respectively. However, compared with the ViV group, the ViR group had lower technical success (83.3% vs. 96.0%; p = 0.001) due to more frequent second valve implantation (11.1% vs. 2.8%; p = 0.008), and lower device success (76.4% vs. 89.2%; p = 0.009) due to more frequent reintervention (16.7% vs. 7.4%; p = 0.03). Mean mitral valve gradients were similar between groups (6.4 ± 2.3 mm Hg vs. 5.8 ± 2.7 mm Hg; p = 0.17), whereas the ViR group had more frequent post-procedural mitral regurgitation moderate or higher (19.4% vs. 6.8%; p = 0.003). Furthermore, the ViR group had more frequent life-threatening bleeding (8.3% vs. 2.3%; p = 0.03), acute kidney injury (11.1% vs. 4.0%; p = 0.03), and subsequent lower procedural success (58.3% vs. 79.5%; p = 0.001). The 1-year all-cause mortality rate was significantly higher in the ViR group compared with the ViV group (28.7% vs. 12.6%; log-rank test, p = 0.01). On multivariable analysis, failed annuloplasty ring was independently associated with all-cause mortality (hazard ratio: 2.70; 95% confidence interval: 1.34 to 5.43; p = 0.005). CONCLUSIONS: The TMVR procedure provided acceptable outcomes in high-risk patients with degenerated bioprostheses or failed annuloplasty rings, but mitral ViR was associated with higher rates of procedural complications and mid-term mortality compared with mitral ViV.


Assuntos
Bioprótese/efeitos adversos , Cateterismo Cardíaco/métodos , Doenças das Valvas Cardíacas/cirurgia , Implante de Prótese de Valva Cardíaca/métodos , Anuloplastia da Valva Mitral/efeitos adversos , Valva Mitral/cirurgia , Idoso , Europa (Continente)/epidemiologia , Feminino , Humanos , Masculino , América do Norte/epidemiologia , Desenho de Prótese , Falha de Prótese , Reoperação , Estudos Retrospectivos , Taxa de Sobrevida/tendências , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA