Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
1.
Cardiovasc Drugs Ther ; 35(2): 309-320, 2021 04.
Artigo em Inglês | MEDLINE | ID: mdl-33515411

RESUMO

PURPOSE: The COMBO biodegradable polymer sirolimus-eluting stent includes endothelial progenitor cell capture (EPC) technology for rapid endothelialization, which may offer advantage in acute coronary syndromes (ACS). We sought to analyze the performance of the COMBO stent by ACS status and ACS subtype. METHODS: The COMBO collaboration (n = 3614) is a patient-level pooled dataset from the MASCOT and REMEDEE registries. We evaluated outcomes by ACS status, and ACS subtype in patients with ST segment elevation myocardial infarction (STEMI) or non-STEMI (NSTEMI) versus unstable angina (UA). The primary endpoint was 1-year target lesion failure (TLF), composite of cardiac death, target vessel myocardial infarction, or clinically driven target lesion revascularization. Secondary outcomes included stent thrombosis (ST). RESULTS: We compared 1965 (54%) ACS and 1649 (46.0%) non-ACS patients. ACS presentations included 40% (n = 789) STEMI, 31% (n = 600) NSTEMI, and 29% (n = 576) UA patients. Risk of 1-year TLF was greater in ACS patients (4.5% vs. 3.3%, HR 1.51 95% CI 1.01-2.25, p = 0.045) without significant differences in definite/probable ST (1.1% vs 0.5%, HR 2.40, 95% CI 0.91-6.31, p = 0.08). One-year TLF was similar in STEMI, NSTEMI, and UA (4.8% vs 4.8% vs. 3.7%, p = 0.60), but definite/probable ST was higher in STEMI patients (1.9% vs 0.5% vs 0.7%, p = 0.03). Adjusted outcomes were not different in MI versus UA patients. CONCLUSIONS: Despite the novel EPC capture technology, COMBO stent PCI was associated with somewhat greater risk of 1-year TLF in ACS than in non-ACS patients, without significant differences in stent thrombosis. No differences were observed in 1-year TLF among ACS subtypes.


Assuntos
Síndrome Coronariana Aguda/cirurgia , Stents Farmacológicos/estatística & dados numéricos , Células Progenitoras Endoteliais/metabolismo , Intervenção Coronária Percutânea/métodos , Síndrome Coronariana Aguda/classificação , Síndrome Coronariana Aguda/complicações , Síndrome Coronariana Aguda/mortalidade , Angina Instável/complicações , Trombose Coronária/epidemiologia , Stents Farmacológicos/efeitos adversos , Humanos , Infarto do Miocárdio/classificação , Infarto do Miocárdio/complicações , Desenho de Prótese , Fatores de Risco , Sirolimo/administração & dosagem , Fatores de Tempo
2.
Catheter Cardiovasc Interv ; 97(5): 797-804, 2021 04 01.
Artigo em Inglês | MEDLINE | ID: mdl-32198837

RESUMO

BACKGROUND: The COMBO drug eluting stent is a novel device with luminal endothelial progenitor cell capture technology for rapid homogeneous endothelialization. METHODS AND RESULTS: We examined for sex differences in 1-year outcomes after COMBO stenting from the COMBO collaboration, a pooled patient-level dataset from the MASCOT and REMEDEE multicenter registries. The primary endpoint was 1-year target lesion failure (TLF), composite of cardiac death, target vessel-myocardial infarction (TV-MI), or clinically driven target lesion revascularization (CD-TLR). Secondary outcomes included stent thrombosis (ST). Adjusted outcomes were assessed using Cox regression methods. The study included 861 (23.8%) women and 2,753 (76.2%) men. Women were older with higher prevalence of several comorbidities including diabetes mellitus. Risk of 1-year TLF was similar in both sexes (3.8% vs. 3.9%, HR 0.92, 95% CI 0.59-1.42, p = .70), without sex differences in the incidence of cardiac death (1.6% vs. 1.5%, p = .78), TV-MI (1.5% vs. 1.1%, p = .32), or CD-TLR (2.0% vs. 2.2%, p = .67). Definite or probable ST occurred in 0.4% women and 1.0% men (HR 0.26, 95% CI 0.06-1.11, p = .069). CONCLUSIONS: Despite greater clinical risks at baseline, women treated with COMBO stents had similarly low 1-year TLF and other ischemic outcomes compared to men.


Assuntos
Doença da Artéria Coronariana , Stents Farmacológicos , Intervenção Coronária Percutânea , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/cirurgia , Feminino , Humanos , Masculino , Intervenção Coronária Percutânea/efeitos adversos , Desenho de Prótese , Fatores de Risco , Caracteres Sexuais , Stents , Fatores de Tempo , Resultado do Tratamento
3.
Int J Cardiol Heart Vasc ; 31: 100605, 2020 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-32953969

RESUMO

BACKGROUND: The COMBO stent is a biodegradable-polymer sirolimus-eluting stent with endothelial progenitor cell capture technology for faster endothelialization. OBJECTIVE: We analyzed COMBO stent outcomes in relation to bleeding risk using the PARIS bleeding score. METHODS: MASCOT was an international registry of all-comers undergoing attempted COMBO stent implantation. We stratified patients as low bleeding-risk (LBR) for PARIS score ≤ 3 and intermediate-to-high (IHBR) for score > 3 based on baseline age, body mass index, anemia, current smoking, chronic kidney disease and need for triple therapy. Primary endpoint was 1-year target lesion failure (TLF), composite of cardiac death, myocardial infarction (MI) not clearly attributed to a non-target vessel or clinically-driven target lesion revascularization (TLR). Bleeding was adjudicated using the Bleeding Academic Research Consortium (BARC) definition. Dual antiplatelet therapy (DAPT) cessation was independently adjudicated. RESULTS: The study included 56% (n = 1270) LBR and 44% (n = 1009) IHBR patients. Incidence of 1-year TLF was higher in IHBR patients (4.1% vs. 2.6%, p = 0.047) driven by cardiac death (1.7% vs. 0.7%, p = 0.029) with similar rates of MI (1.8% vs. 1.1%, p = 0.17), TLR (1.5% vs. 1.6%, p = 0.89) and definite/ probable stent thrombosis (1.2% vs. 0.6%, p = 0.16). Incidence of 1-year major BARC 3 or 5 bleeding was significantly higher in IHBR patients (2.3% vs. 0.9%, p = 0.0094), as was the incidence of DAPT cessation (29.3% vs. 22.8%, p < 0.01), driven by physician-guided discontinuation. CONCLUSIONS: Patients with intermediate-to-high PARIS bleeding risk in the MASCOT registry experienced greater incidence of 1-year TLF, major bleeding and DAPT cessation than LBR patients, without significant differences in stent thrombosis.

4.
Cardiovasc Revasc Med ; 21(12): 1542-1547, 2020 12.
Artigo em Inglês | MEDLINE | ID: mdl-32507695

RESUMO

BACKGROUND: Small vessel diameter is associated with higher risk of target lesion revascularization (TLR) after percutaneous coronary intervention (PCI). The COMBO sirolimus-eluting biodegradable-polymer stent has a proprietary anti-CD34 antibody layer to enhance homogeneous endothelialization, which may be advantageous in treating small vessels. OBJECTIVE: We examined for differences in 1-year clinical outcomes after PCI by maximum implanted stent diameter from the COMBO collaboration. METHODS: The COMBO collaboration (n = 3614) is a patient-level pooled dataset of patients undergoing PCI with COMBO stents in the MASCOT and REMEDEE multicenter registries. Stent diameter was available in 3590 (99.3%) patients. We compared patients receiving COMBO stents <3 mm versus ≥3 mm. The primary endpoint was 1-year target lesion failure (TLF), composite of cardiac death, target vessel-myocardial infarction (TV-MI) or clinically driven TLR. Secondary outcomes included stent thrombosis (ST). Adjusted outcomes were assessed using Cox regression methods. RESULTS: The study included 792 (22%) patients with small stents <3 mm and 2798 (78%) patients with large stents ≥3 mm. Small stent patients included more women with lower body mass index and higher prevalence of diabetes but similar prevalence of acute coronary syndrome. Risk of 1-year TLF was similar in small and large stent groups (4.4% vs. 3.8%, HR 1.12, 95% CI 0.74-1.72, p = 0.58). There were no differences in the rates of cardiac death (1.7% vs. 1.5%, p = 0.74), TV-MI (1.4% vs. 1.2%, p = 0.58) or TLR (2.7% vs. 2.1%, p = 0.31). Definite or probable ST occurred in 1.3% of the small stent and 0.7% of the large stent PCI patients, p = 0.14, HR 2.13, 95% CI 0.93-5.00, p = 0.07. CONCLUSIONS: One-year ischemic outcomes after COMBO PCI were similar irrespective of stent diameter in this all-comers international cohort.


Assuntos
Doença da Artéria Coronariana , Intervenção Coronária Percutânea , Stents , Feminino , Humanos , Desenho de Prótese , Fatores de Risco , Resultado do Tratamento
5.
Am J Cardiol ; 127: 1-8, 2020 07 15.
Artigo em Inglês | MEDLINE | ID: mdl-32418717

RESUMO

Older patients who undergo coronary interventions are at greater risk of ischemic events and less likely to tolerate prolonged dual antiplatelet therapy (DAPT) due to bleeding risk. The COMBO biodegradable polymer sirolimus-eluting stent promotes rapid endothelialization through endothelial progenitor cell capture technology which may be advantageous in elderly patients. We compared 1-year clinical outcomes and DAPT cessation events in patients >75 versus ≤75 years from the MASCOT registry. MASCOT was a prospective, multicenter cohort study of all-comers undergoing attempted COMBO stenting. The primary endpoint was 1-year target lesion failure (TLF), composite of cardiac death, myocardial infarction (MI) not clearly attributed to a nontarget vessel or clinically driven target lesion revascularization. Bleeding was adjudicated using the Bleeding Academic Research Consortium criteria. Adjusted outcomes were analyzed using Cox regression methods. The study included 18% (n = 479) patients >75 years and 72% (n = 2,135) patients ≤75 years. One-year TLF occurred in 4.6% patients >75 years versus 3.1% patients ≤75years of age, p = 0.10; adj hazard ratio 1.36, 95% confidence intervals 0.77 to 2.38, p = 0.29. There were no significant differences in cardiac death (1.7% vs 1.3%, p = 0.55), MI (2.1% vs 1.2%, p = 0.14), target lesion revascularization (1.7% vs 1.4%, p = 0.60) and definite stent thrombosis (0.8% vs 0.4%, p = 0.19). Major Bleeding Academic Research Consortium 3,5 bleeding (3.1% vs 1.5%, p = 0.01) and DAPT cessation rates (32.4% vs 23.0%, p <0.001) were significantly higher in elderly patients. In conclusion, elderly patients >75 years treated with COMBO stents had similar TLF but significantly greater incidence of bleeding than younger patients and DAPT cessation in one-third of patients over 1 year.


Assuntos
Implantes Absorvíveis , Doença da Artéria Coronariana/cirurgia , Stents Farmacológicos , Intervenção Coronária Percutânea/métodos , Polímeros , Complicações Pós-Operatórias/epidemiologia , Sistema de Registros , Idoso , Idoso de 80 Anos ou mais , Angiografia Coronária , Doença da Artéria Coronariana/diagnóstico , Feminino , Saúde Global , Humanos , Incidência , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Desenho de Prótese , Resultado do Tratamento
6.
Int J Cardiol ; 307: 17-23, 2020 05 15.
Artigo em Inglês | MEDLINE | ID: mdl-32111358

RESUMO

BACKGROUND: The COMBO drug-eluting stent combines sirolimus-elution from a biodegradable polymer with an anti-CD34+ antibody coating for early endothelialization. OBJECTIVE: We investigated for geographical differences in outcomes after percutaneous coronary intervention (PCI) with the COMBO stent among Asians and Europeans. METHODS: The COMBO Collaboration is a pooled patient-level analysis of the MASCOT and REMEDEE registries of all-comers undergoing attempted COMBO stent PCI. The primary outcome was 1-year target lesion failure (TLF), composite of cardiac death, target vessel myocardial infarction (TV-MI) and target lesion revascularization (TLR). RESULTS: This study included 604 Asians (17.9%) and 2775 Europeans (82.1%). Asians were younger and included fewer females, with a higher prevalence of diabetes mellitus but lower prevalence of other comorbidities than Europeans. Asians had a higher prevalence of ACC/AHA C type lesions and received longer stent lengths. More Asians than Europeans were discharged on clopidogrel (86.5% vs 62.8%) rather than potent P2Y12 inhibitors. One-year TLF occurred in 4.0% Asians and 4.1% of Europeans, p = 0.93. The incidence of cardiac death was higher in Asians (2.8% vs. 1.3%, p = 0.007) with similar rates of TV-MI (1.5% vs. 1.2%, p = 0.54) and definite stent thrombosis (0.3% vs. 0.5%, p = 0.84) and lower incidence of TLR than Europeans (1.0% vs. 2.5%, p = 0.025). After adjustment, differences for cardiac death and TLR were no longer significant. CONCLUSIONS: In the COMBO collaboration, although 1-year TLF was similar regardless of geography, Asians experienced higher rates of cardiac death and lower TLR than Europeans, while incidence of TV-MI and ST was similar in both regions. Adjusted differences did not reach statistical significance. CLINICALTRIAL. GOV IDENTIFIER-NUMBERS: NCT01874002 (REMEDEE Registry), NCT02183454 (MASCOT registry).


Assuntos
Doença da Artéria Coronariana , Stents Farmacológicos , Intervenção Coronária Percutânea , Ásia/epidemiologia , Doença da Artéria Coronariana/cirurgia , Europa (Continente)/epidemiologia , Feminino , Geografia , Humanos , Intervenção Coronária Percutânea/efeitos adversos , Desenho de Prótese , Fatores de Risco , Stents , Fatores de Tempo , Resultado do Tratamento
7.
Am J Case Rep ; 21: e919766, 2020 Mar 13.
Artigo em Inglês | MEDLINE | ID: mdl-32165609

RESUMO

BACKGROUND Bicuspid aortic valve is the most common congenital heart malformation, encountered in 1-2% of the population, while interventricular septal defect and patent ductus arteriosus are the most common congenital malformations associated with bicuspid aortic valve. Although bicuspid valve can have no clinical manifestation, patients with bicuspid valve are prone to develop vascular abnormalities. Aortic dilatation is the most common of these abnormalities, which in turn can lead to serious complications and often requires surgical treatment. Coexistence of bicuspid aortic valve and interventricular septal aneurysm is very extremely rare. CASE REPORT We present a very rare case of a female patient with combined congenital cardiac pathology. The patient was asymptomatic until age 68 years, and presented with nonspecific persistent cough. The diagnostic work-up for the unexplained cough showed normal function of the bicuspid valve and an ascending aorta aneurysm accompanied with interventricular septal aneurysm. The patient was referred for surgery. The diagnostic work-up and the decision for surgical treatment were thoroughly discussed to determine whether it was a true or a false aneurysm. CONCLUSIONS The presented case is an example of late diagnosis of a congenital cardiac defect. The silent evolution and the scarce clinical presentation led to incidental discovery of the pathology, which was fully assessed only by computed tomography. Although echocardiography is essential for discovering heart defects, non-invasive imaging techniques are required for detailed morphological assessment and for planning optimal surgical treatment.


Assuntos
Aneurisma Aórtico/diagnóstico por imagem , Aneurisma Aórtico/cirurgia , Cardiopatias Congênitas/diagnóstico por imagem , Idoso , Valva Aórtica/anormalidades , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Doença da Válvula Aórtica Bicúspide , Angiografia por Tomografia Computadorizada , Ecocardiografia , Feminino , Doenças das Valvas Cardíacas/diagnóstico por imagem , Doenças das Valvas Cardíacas/cirurgia , Humanos , Achados Incidentais , Transtornos de Início Tardio/diagnóstico por imagem , Transtornos de Início Tardio/cirurgia
9.
Int J Cardiol ; 283: 67-72, 2019 05 15.
Artigo em Inglês | MEDLINE | ID: mdl-30826192

RESUMO

BACKGROUND: The COMBO stent (OrbusNeich Medical, Ft. Lauderdale, Florida) is a new-generation bio-engineered drug eluting stent, combining an abluminal coating of a bioabsorbable polymer matrix for sustained release of sirolimus and luminal anti-CD34 coating for endothelial progenitor cell capture and rapid endothelialization. METHODS: The Multinational Abluminal Sirolimus Coated BiO-Engineered StenT (MASCOT) registry was a prospective post-marketing study conducted from June 2014-May 2017 across 60 centers globally. Patients were eligible if COMBO stent implantation was attempted, and they received dual antiplatelet therapy (DAPT) per local guidelines. Follow-up was conducted by trained research staff at 1, 6 and 12 months by phone or clinic visit to capture clinical events and DAPT cessation events. The primary endpoint was 1-year target lesion failure (TLF), composite of cardiac death, non-fatal myocardial infarction not clearly attributable to a non-target vessel, or ischemia-driven target lesion revascularization. RESULTS: A total of 2614 patients were enrolled over the study period with 96.7% completion of 1-year follow-up. The mean age of enrolled patients was 62.9 ±â€¯11.2 years and 23.0% were female. Diabetes mellitus was present at baseline in 33.5%. A total of 56.1% patients underwent PCI for acute coronary syndrome (ACS). The 1-year primary endpoint of TLF occurred in 3.4% patients (n = 88). Definite stent thrombosis occurred in 0.5% patients (n = 12). CONCLUSION: The MASCOT post marketing registry provides comprehensive safety and efficacy outcomes following contemporary PCI using the novel COMBO stent in an all-comer population. This platform is associated with low rates of 1-year TLF and ST. CLINICALTRIALS. GOV IDENTIFIER: NCT02183454.


Assuntos
Doença da Artéria Coronariana/cirurgia , Stents Farmacológicos , Intervenção Coronária Percutânea/métodos , Vigilância de Produtos Comercializados/estatística & dados numéricos , Sistema de Registros , Sirolimo/farmacologia , Bioengenharia/métodos , Feminino , Seguimentos , Humanos , Imunossupressores/farmacologia , Masculino , Pessoa de Meia-Idade , Desenho de Prótese , Estudos Retrospectivos , Fatores de Tempo , Resultado do Tratamento
10.
BMC Cardiovasc Disord ; 13: 92, 2013 Oct 26.
Artigo em Inglês | MEDLINE | ID: mdl-24160570

RESUMO

BACKGROUND: The aim of the study was to investigate the relationship between the ejection fraction (EF) and the mitral annular systolic velocity (Sm) in patients with preserved left ventricular systolic function (EF>55%). The study task was to evaluate whether the assessment of Sm(avg) can be used as an alternative to the Simpson's method in assessment of the EF. The expected benefit was that Sm could be used to predict EF, when EF is difficult to assess due to poor image quality (IQ). METHOD: Sm was obtained by spectral pulse wave Tissue Doppler Imaging (pwTDI) from the lateral and septal sites of the mitral annulus (MA) and an averaged value was calculated - Sm(avg). EF was assessed using Simpson's rule. Participants were divided into controls (n=70), hypertensive (HTN, n=56), HTN with diastolic dysfunction (HTN/DD, n=65), HTN with diabetes mellitus (HTN/DM, n=52) and HTN with DD and DM (HTN/DD/DM, n=65). RESULTS: Sm(avg) showed strong correlation with EF (r=0.978; p<0.0001). There were no significant differences between the correlation coefficients between the subgroups and the controls. The mathematical model that the study recommended to assess the EF is: EF=45.0 + 2 × Sm(avg). CONCLUSION: The assessment of Sm(avg) could be used as an alternative to EF. This approach may be useful especially when the IQ is poor. The method maintains high accuracy and reproducibility in prediction of the EF.


Assuntos
Valva Mitral/diagnóstico por imagem , Valva Mitral/fisiologia , Volume Sistólico/fisiologia , Função Ventricular Esquerda/fisiologia , Adulto , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Sístole/fisiologia , Ultrassonografia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA