Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 17 de 17
Filtrar
1.
Can Assoc Radiol J ; : 8465371241253254, 2024 May 25.
Artigo em Inglês | MEDLINE | ID: mdl-38795027

RESUMO

Objective: To investigate the features and outcomes of breast cancer in high-risk subgroups. Materials and Methods: REB approved an observational study of women diagnosed with breast cancer from 2010 to 2019. Three radiologists, using the BI-RADS lexicon, blindly reviewed mammogram and MRI screenings without a washout period. Consensus was reached with 2 additional reviewers. Inter-rater agreement was measured by Fleiss Kappa. Statistical analysis included Mann-Whitney U, Chi-square tests for cohort analysis, and Kaplan-Meier for survival rates, with a Cox model for comparative analysis using gene mutation as a reference. Results: The study included 140 high-risk women, finding 155 malignant lesions. Significant age differences noted: chest radiation therapy (median age 44, IQR: 37.0-46.2), gene mutation (median age 49, IQR: 39.8-58.0), and familial risk (median age 51, IQR: 44.5-56.0) (P = .007). Gene mutation carriers had smaller (P = .01), higher-grade tumours (P = .002), and more triple-negative ER- (P = .02), PR- (P = .002), and HER2- (P = .02) cases. MRI outperformed mammography in all subgroups. Substantial to near-perfect inter-rater agreement observed. Over 10 years, no deaths occurred in chest radiation group, with no significant survival difference between gene mutation and familial risk groups, HR = 0.93 (95% CI: 0.27, 3.26), P = .92. Conclusion: The study highlights the importance of age and specific tumour characteristics in identifying high-risk breast cancer subgroups. MRI is confirmed as an effective screening tool. Despite the aggressive nature of cancers in gene mutation carriers, early detection is crucial for survival outcomes. These insights, while necessitating further validation with larger studies, advocate for a move toward personalized medical care, strengthening the existing healthcare guidelines.

2.
Eur Radiol ; 2024 Mar 16.
Artigo em Inglês | MEDLINE | ID: mdl-38491128

RESUMO

OBJECTIVE: This study aims to determine whether persistent T1-weighted lesions signify a complete pathological response (pCR) in breast cancer patients treated with neoadjuvant chemotherapy and surgery, and to evaluate their correlation with imaging responses on MRI. MATERIALS AND METHODS: A retrospective review was conducted on data from breast cancer patients treated between January 2011 and December 2018. Patients who underwent breast MRI and pre- and post-neoadjuvant chemotherapy followed by surgery were included. Those with distant metastasis, no planned surgery, pre-surgery radiation, ineligibility for neoadjuvant chemotherapy, or unavailable surgical pathology were excluded. Groups with and without persistent T1-weighted lesions were compared using the chi-square test for categorical variables and the Student t test or Wilcox rank sum test for continuous variables. Univariate logistic regression was used to evaluate the association of the final pathological response with the presence of T1-persistent lesion and other characteristics. RESULTS: Out of 319 patients, 294 met the inclusion criteria (breast cancer patients treated with neoadjuvant chemotherapy and subsequent surgery); 157 had persistent T1 lesions on post-chemotherapy MRI and 137 did not. A persistent T1 lesion indicated reduced likelihood of complete pathological response (14% vs. 39%, p < 0.001) and imaging response (69% vs. 93%, p < 0.001). Multivariable analysis confirmed these findings: OR 0.37 (95% CI 0.18-0.76), p = 0.007. No other characteristics correlated with T1 residual lesions. CONCLUSION: Persistent T1-weighted lesions without associated abnormal enhancement on post-treatment breast MRI correlate with lower complete pathological and imaging response rates. CLINICAL RELEVANCE STATEMENT: The study underscores the importance of persistent T1-weighted lesions on breast MRI as vital clinical markers, being inversely related to a complete pathological response following neoadjuvant chemotherapy; they should be a key factor in guiding post-neoadjuvant chemotherapy treatment decisions. KEY POINTS: • Persistent T1 lesions on post-chemotherapy breast MRI indicate a reduced likelihood of achieving a complete pathological response (14% vs. 39%, p < 0.001) and imaging response (69% vs. 93%, p < 0.001). • Through multivariable analysis, it was confirmed that the presence of a persistent T1 lesion on breast MRI post-chemotherapy is linked to a decreased likelihood of complete pathological response, with an odds ratio (OR) of 0.37 (95% CI 0.18-0.76; p = 0.007). • In addition to the convention of equating the absence of residual enhancement to complete imaging response, our results suggest that the presence or absence of residual T1 lesions should also be considered.

3.
Radiol Imaging Cancer ; 6(2): e230020, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38334470

RESUMO

Purpose To investigate the feasibility of low-dose positron emission mammography (PEM) concurrently to MRI to identify breast cancer and determine its local extent. Materials and Methods In this research ethics board-approved prospective study, participants newly diagnosed with breast cancer with concurrent breast MRI acquisitions were assigned independently of breast density, tumor size, and histopathologic cancer subtype to undergo low-dose PEM with up to 185 MBq of fluorine 18-labeled fluorodeoxyglucose (18F-FDG). Two breast radiologists, unaware of the cancer location, reviewed PEM images taken 1 and 4 hours following 18F-FDG injection. Findings were correlated with histopathologic results. Detection accuracy and participant details were examined using logistic regression and summary statistics, and a comparative analysis assessed the efficacy of PEM and MRI additional lesions detection (ClinicalTrials.gov: NCT03520218). Results Twenty-five female participants (median age, 52 years; range, 32-85 years) comprised the cohort. Twenty-four of 25 (96%) cancers (19 invasive cancers and five in situ diseases) were identified with PEM from 100 sets of bilateral images, showcasing comparable performance even after 3 hours of radiotracer uptake. The median invasive cancer size was 31 mm (range, 10-120). Three additional in situ grade 2 lesions were missed at PEM. While not significant, PEM detected fewer false-positive additional lesions compared with MRI (one of six [16%] vs eight of 13 [62%]; P = .14). Conclusion This study suggests the feasibility of a low-dose PEM system in helping to detect invasive breast cancer. Though large-scale clinical trials are essential to confirm these preliminary results, this study underscores the potential of this low-dose PEM system as a promising imaging tool in breast cancer diagnosis. ClinicalTrials.gov registration no. NCT03520218 Keywords: Positron Emission Digital Mammography, Invasive Breast Cancer, Oncology, MRI Supplemental material is available for this article. © RSNA, 2024 See also commentary by Barreto and Rapelyea in this issue.


Assuntos
Neoplasias da Mama , Humanos , Feminino , Pessoa de Meia-Idade , Neoplasias da Mama/diagnóstico por imagem , Fluordesoxiglucose F18 , Tomografia por Emissão de Pósitrons/métodos , Estudos Prospectivos , Elétrons , Compostos Radiofarmacêuticos , Tomografia Computadorizada por Raios X , Mamografia
4.
Breast Cancer Res Treat ; 205(1): 159-168, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38305940

RESUMO

PURPOSE: To determine the malignancy rate for MRI-guided breast biopsies performed for T2 hyperintense breast lesions and to assess additional clinical and MRI characteristics that can predict benign and malignant outcomes. METHODS: A retrospective chart review of consecutive MRI-guided breast biopsies performed in two tertiary hospitals was conducted over two years. Biopsies performed for T2 hyperintense lesions were selected, and further lesion imaging characteristics and patient risk factors were collected. Univariate and multivariate modeling regression were used to determine additional imaging and patient factors associated with malignant outcomes for biopsies of T2 hyperintense lesions. RESULTS: Out of 369 MRI-guided breast biopsies, 100 (27%) were performed for T2 hyperintense lesions. Two biopsy-proven benign lesions were excluded as the patient was lost on follow-up. With a study cohort of 98 lesions, the final pathology results were benign for 80 (80%) of these lesions, while 18 (18%) were malignant. Using multivariate logistic modeling, patient age > 50 (OR 5.99 (1.49, 24.08 95% CI), p < 0.05) and lesion size > 3 cm (OR 5.54 (1.54-18.7), p < 0.01) were found to be important predictors of malignant outcomes for MRI biopsies performed for T2 hyperintense lesions. CONCLUSION: Our study observed a high malignancy rate, challenging the assumption that T2 hyperintensity can be considered a benign imaging characteristic for otherwise suspicious MRI-detected lesions. Decision-making regarding tissue sampling should be made based on a thorough evaluation of more reliable additional demographic and imaging factors, including patient age and lesion size.


Assuntos
Neoplasias da Mama , Biópsia Guiada por Imagem , Imageamento por Ressonância Magnética , Humanos , Feminino , Neoplasias da Mama/patologia , Neoplasias da Mama/diagnóstico por imagem , Pessoa de Meia-Idade , Imageamento por Ressonância Magnética/métodos , Estudos Retrospectivos , Adulto , Idoso , Biópsia Guiada por Imagem/métodos , Mama/patologia , Mama/diagnóstico por imagem , Fatores de Risco
5.
Clin Imaging ; 99: 41-46, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-37060681

RESUMO

OBJECTIVE: To determine the frequency and distinguishing imaging characteristics of breast cancers detected on screening mammography which was initially evaluated as a probably benign lesion and the workup was delayed due to the COVID-19 pandemic. MATERIALS AND METHODS: REB-approved multicenter retrospective screening mammography studies and patient's chart review carried out between February 2020 and March 2020. According to an institutional decision, the frequency and imaging findings deemed probably benign on screening mammography after review by a breast fellowship-trained radiologist with workup deferred until after the first pandemic wave plateau in late July 2020 were recorded. Results were correlated with histopathology if tissue sample performed or an uneventful 2 years follow-up. Descriptive statistical analysis was used to describe the retrieved data set. RESULTS: Out of 1816 mammography screening between February 2020 and March 2020, 99 women, median age 58 years (range 35-84), 99 mammography had possibly benign findings with workup delayed, and two patients, age 49 and 56, had cancers (2.02%), misinterpreted as benign findings. Both malignant cases were focal asymmetries, with pathology of invasive ductal carcinoma, 12 mm and 9 mm in size. No in-situ carcinoma was detected. CONCLUSION: The low rate of cancer detected suggests that a delay callback may be a reasonable option for some likely benign findings when immediate callback is not an option, such as during a pandemic. Larger studies would be helpful to support our findings and may allow us to translate the adoption of such a model during potential future pandemic. CLINICAL RELEVANCE: The results of this study may be helpful for a future situation when delaying a call back from screening mammography is again required.


Assuntos
Neoplasias da Mama , COVID-19 , Feminino , Humanos , Adulto , Pessoa de Meia-Idade , Idoso , Idoso de 80 Anos ou mais , Mamografia/métodos , Neoplasias da Mama/diagnóstico por imagem , Neoplasias da Mama/epidemiologia , Pandemias , Estudos Retrospectivos , Detecção Precoce de Câncer , COVID-19/epidemiologia , Programas de Rastreamento
6.
Breast Cancer Res Treat ; 198(2): 321-334, 2023 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-36740611

RESUMO

PURPOSE: To identify demographic and imaging features of MRI-detected enhancing lesions without clinical, ultrasound, and mammographic correlation associated with false-positive outcomes, impacting patient care. MATERIALS AND METHODS: A retrospective multi-institutional study of imaging studies and patient's chart review of consecutive women with MRI-detected enhancing lesions without clinical, mammogram, or ultrasound correlation between January and December 2018, who underwent MRI-guided biopsy. According to the BI-RADS lexicon, lesions' frequency and imaging features were recorded. The demographic and imaging characteristics variables were correlated with histopathology as the gold standard and an uneventful follow-up of at least one year. Univariate logistic regression analysis was used to explore the correlation between the baseline variables such as age, genetic mutation, family history of breast cancer, personal history of breast cancer, MRI indication, background parenchymal enhancement, and MRI characteristic of the lesion with the false-positive results in main data and subgroup analysis. RESULTS: Two hundred nineteen women (median age 49 years; range 26-85 years) with 219 MRI-detected enhancing lesions that underwent MRI-guided vacuum-assisted biopsy during the study period fulfilled the study criteria and formed the study cohort. Out of 219, 180 lesions (82.2%) yielded benign pathology results, including 137 benign outcomes (76%) and 43 high-risk lesions (24%). Most demographic and imaging characteristics variables did not help to differentiate malignant from benign lesions. The variables that showed statistically significant association with true-positive results in univariate analyses were age (OR 1.05; 95% CI 1.02-1.08; p = 0.0015), irregular mass-lesion shape when compared with oval/round mass lesion (OR 11.2; 95% CI 1.6-78.4; p = 0.015), and clumped and clustered ring of enhancement when compared with homogeneous (OR 3.22, 95% CI 1.40-7.40; p = 0.0058). For participants with mass breast lesion, the hyperintense signal on the T2-weighted sequence (compared to the normal fibroglandular signal) was significantly related to the false-positive result (OR 0.13; 95% CI 0.02-0.76; p = 0.024). CONCLUSION: Young patients, oval/round mass-lesion shape, and homogeneous pattern of non-mass enhancement showed the strongest association with false-positive results of enhancing lesions depicted by MRI. For participants with mass breast lesion, T2-bright mass lesion showed significant association with false-positive result. It may impact the patient's management with a suggestion of follow-up rather than interventional procedure when these demographic and imaging parameters are present, consequently decreasing the patient's anxiety and health care costs.


Assuntos
Neoplasias da Mama , Feminino , Humanos , Pessoa de Meia-Idade , Mama/diagnóstico por imagem , Mama/patologia , Neoplasias da Mama/diagnóstico por imagem , Neoplasias da Mama/patologia , Imageamento por Ressonância Magnética/métodos , Estudos Retrospectivos , Sensibilidade e Especificidade
7.
Radiology ; 306(3): e221785, 2023 03.
Artigo em Inglês | MEDLINE | ID: mdl-36719288

RESUMO

Background The best supplemental breast cancer screening modality in women at average risk or intermediate risk for breast cancer with dense breast and negative mammogram remains to be determined. Purpose To conduct systematic review and meta-analysis comparing clinical outcomes of the most common available supplemental screening modalities in women at average risk or intermediate risk for breast cancer in patients with dense breasts and mammography with negative findings. Materials and Methods A comprehensive search was conducted until March 12, 2020, in Medline, Epub Ahead of Print and In-Process and Other Non-Indexed Citations; Embase Classic and Embase; Cochrane Central Register of Controlled Trials; and Cochrane Database of Systematic Reviews, for Randomized Controlled Trials and Prospective Observational Studies. Incremental cancer detection rate (CDR); positive predictive value of recall (PPV1); positive predictive value of biopsies performed (PPV3); and interval CDRs of supplemental imaging modalities, digital breast tomosynthesis, handheld US, automated breast US, and MRI in non-high-risk patients with dense breasts and mammography negative for cancer were reviewed. Data metrics and risk of bias were assessed. Random-effects meta-analysis and two-sided metaregression analyses comparing each imaging modality metrics were performed (PROSPERO; CRD42018080402). Results Twenty-two studies reporting 261 233 screened patients were included. Of 132 166 screened patients with dense breast and mammography negative for cancer who met inclusion criteria, a total of 541 cancers missed at mammography were detected with these supplemental modalities. Metaregression models showed that MRI was superior to other supplemental modalities in CDR (incremental CDR, 1.52 per 1000 screenings; 95% CI: 0.74, 2.33; P < .001), including invasive CDR (invasive CDR, 1.31 per 1000 screenings; 95% CI: 0.57, 2.06; P < .001), and in situ disease (rate of ductal carcinoma in situ, 1.91 per 1000 screenings; 95% CI: 0.10, 3.72; P < .04). No differences in PPV1 and PPV3 were identified. The limited number of studies prevented assessment of interval cancer metrics. Excluding MRI, no statistically significant difference in any metrics were identified among the remaining imaging modalities. Conclusion The pooled data showed that MRI was the best supplemental imaging modality in women at average risk or intermediate risk for breast cancer with dense breasts and mammography negative for cancer. © RSNA, 2023 Supplemental material is available for this article. See also the editorial by Hooley and Butler in this issue.


Assuntos
Neoplasias da Mama , Feminino , Humanos , Neoplasias da Mama/patologia , Mamografia/métodos , Densidade da Mama , Detecção Precoce de Câncer/métodos , Mama/diagnóstico por imagem , Mama/patologia , Programas de Rastreamento/métodos , Estudos Observacionais como Assunto
8.
Altern Ther Health Med ; 29(8): 12-19, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-35139488

RESUMO

Context: Eight-section Brocades, a qigong protocol, has been shown to reduce depressive symptoms in older adults with chronic physical illness, but its positive effects on quality of life, such as subjective well-being, aren't known. Objective: This study intended to evaluate the efficacy of qigong for increasing subjective well-being in older adults with chronic physical illness. Design: A randomized controlled trial was conducted. Setting: A governmental family clinic in Hong Kong. Participants: Participants were 47 older adults, 19 males and 28 females, with chronic physical illness. Intervention: Participants were randomly assigned to an Eight-section Brocades group (n = 25) or a cognitive training group (n = 22). The groups received 12 weeks of the Eight-section Brocades intervention or of cognitive training, respectively. Outcome Measures: The primary outcome-subjective well-being-and the secondary outcomes-functional independence, sleep quality, mobility, and hand grip strength-were assessed at baseline, postintervention, and at a one-month follow-up. Results: No significant between-group differences were observed in improvements in subjective well-being or any of the secondary outcomes. Significant improvements in subjective sleep quality and decreases in daytime dysfunction over time were reported by participants in both groups. Conclusions: The findings didn't support 12 weeks of Eight-section Brocades qigong as an effective treatment to enhance the subjective well-being of older adults with chronic physical illness. These null findings may be due to the possibilities that: (1) the treatment may have minimal effects on positive psychology outcomes; (2) the primary outcome measure showed possible ceiling effects for the groups; (3) the current study used an active control condition that may have had more benefits than the control conditions used in previous studies; (4) the current study may have been underpowered; (5) more than 12 weeks (24 sessions) of qigong may be required to impact well-being; or (6) some combination of these factors may have affected the results.


Assuntos
Qigong , Masculino , Feminino , Humanos , Idoso , Qigong/métodos , Hong Kong , Qualidade de Vida , Força da Mão , Doença Crônica
9.
Radiology ; 304(2): 297-307, 2022 08.
Artigo em Inglês | MEDLINE | ID: mdl-35471109

RESUMO

Background The diagnostic value of screening the contralateral breast with MRI in patients with newly diagnosed breast cancer is poorly understood. Purpose To assess the impact of MRI for screening the contralateral breast on long-term outcomes in patients with newly diagnosed breast cancer and to determine whether subgroups with unfavorable prognoses would benefit from MRI in terms of survival. Materials and Methods Data on consecutive patients with newly diagnosed breast cancer seen from January 2008 to December 2010 were reviewed retrospectively. Patients with neoadjuvant chemotherapy, previous breast cancer, distant metastasis, absence of contralateral mammography at diagnosis, and no planned surgical treatment were excluded. Groups that did and did not undergo preoperative MRI were compared. Survival analysis was performed using the Kaplan-Meier method for propensity score-matched groups to estimate cause-specific survival (CSS) and overall survival (OS). A marginal Cox proportional hazards model was used to evaluate association of MRI and clinicopathologic variables with OS. Results Of 1846 patients, 1199 fulfilled the inclusion criteria. Median follow-up time was 10 years (range, 0-14 years). The 2:1 matched sample comprised 705 patients (470 in the MRI group and 235 in the no-MRI group); median ages at surgery were 59 years (range, 31-87 years) and 64 years (range, 37-92 years), respectively. MRI depicted contralateral synchronous disease more frequently (27 of 470 patients [5.7%] vs five of 235 patients [2.1%]; P = .047) and was associated with a higher OS (hazard ratio [HR], 2.51; 95% CI: 1.25, 5.06; P = .01). No differences were observed between groups in metachronous disease rate (MRI group: 21 of 470 patients [4.5%]; no-MRI group: 10 of 235 patients [4.3%]; P > .99) or CSS (HR, 1.34; 95% CI: 0.56, 3.21; P = .51). MRI benefit was greater in patients with larger tumor sizes (>2 cm) (HR, 2.58; 95% CI: 1.11, 5.99; P = .03) and histologic grade III tumors (HR, 2.94; 95% CI: 1.18, 7.32; P = .02). Conclusion Routine MRI screening of the contralateral breast after first diagnosis of breast cancer improved overall survival; the most pronounced benefit was found in patients with larger primary tumor size and primary tumors of histologic grade III. © RSNA, 2022 Online supplemental material is available for this article. See also the editorial by Taourel in this issue.


Assuntos
Neoplasias da Mama , Mama/diagnóstico por imagem , Mama/patologia , Mama/cirurgia , Neoplasias da Mama/diagnóstico por imagem , Neoplasias da Mama/cirurgia , Detecção Precoce de Câncer , Feminino , Humanos , Mamografia/métodos , Estudos Retrospectivos
10.
Radiol Case Rep ; 17(3): 775-778, 2022 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-34976267

RESUMO

Worldwide, many vaccines have been developed in response to the COVID-19 pandemic. Unilateral reactive axillary adenopathy related to the COVID-19 vaccine is a well-known occurrence. In addition, axillary edema has also been observed following COVID-19 vaccinations in patients undergoing breast MRI, and radiologists need to be aware of this possibility to avoid performing unnecessary work-up that can be costly to the health care system and be stressful for patients.

11.
Eur J Radiol Open ; 7: 100265, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32905013

RESUMO

The pandemic caused by the new Coronavirus has changed the way patient care is provided worldwide. This review focuses on the description of the operational measures implemented in a breast imaging department in accordance with existing recommendations for the treatment of breast cancer during the COVID-19 pandemic to make optimal use of finite resources without interruption of essential imaging services for breast cancer patients. It will also apply during a second-wave of the pandemic, which, according to experts, is inevitable and requires us to be better prepared.

12.
J Ultrasound Med ; 38(9): 2395-2406, 2019 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-30666681

RESUMO

OBJECTIVES: To determine the value of shear wave elastography (SWE) added to targeted ultrasound (US) after breast magnetic resonance imaging (MRI). METHODS: From July 2015 to October 2017, 40 patients who underwent targeted US evaluations of suspicious MRI-detected American College of Radiology Breast Imaging Reporting and Data System category 4 lesions (mass or nonmass enhancement) were enrolled in this prospective study. B-mode US and SWE examinations were performed to detect US correlates to MRI-detected lesions; their Breast Imaging Reporting and Data System categories were recorded; lesions that were dark blue on a 6-point color scale or had maximum elasticity of 30 kPa or less were categorized as soft. Biopsy was performed with US or MRI guidance, with the pathologic findings correlated with MRI, US, and SWE findings. The value of SWE for lesion detection and identification of benign lesions was determined. RESULTS: The mean age of the 40 patients was 51.1 years. There were 48 MRI-detected lesions (20 cancers, 3 high-risk lesions, and 25 benign lesions). Ultrasound correlates (8 category 3 and 25 category 4) were shown for 33 lesions (69%; P < .0001), with 16 cancers (80%; P < .0001) and 17 benign lesions. Shear wave elastography assisted detection of 3 (19%) cancers on US imaging. All 7 soft US category 3 lesions were benign (7 of 33 [21%]; P = .0014). CONCLUSIONS: Shear wave elastography was useful with targeted US after breast MRI to increase cancer detection by US. A significant number of US correlates to MRI-detected lesions could have been identified as benign (category 3 and soft) before biopsy, with the potential of short-interval follow-up of MRI-detected lesions with benign US correlates instead of biopsy.


Assuntos
Neoplasias da Mama/diagnóstico por imagem , Técnicas de Imagem por Elasticidade/métodos , Imageamento por Ressonância Magnética/métodos , Ultrassonografia Mamária/métodos , Adulto , Idoso , Mama/diagnóstico por imagem , Diagnóstico Diferencial , Feminino , Humanos , Pessoa de Meia-Idade , Estudos Prospectivos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
13.
J Ultrasound Med ; 36(9): 1883-1894, 2017 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-28556296

RESUMO

OBJECTIVES: The purpose of this study is to correlate various features of breast cancers on ultrasound to their histological grade and immunohistochemical biomarkers. METHODS: Seventy-three patients with 77 invasive breast cancers, diagnosed between August 2011 and December 2014, were included in this prospective analysis. Margin, posterior features, shape, and vascularity were determined from ultrasound and classified according to the Breast Imaging Reporting and Data System lexicon. Histological grade, estrogen receptor (ER), progesterone receptor (PR), and human epidermal growth factor receptor 2 (HER2) status (positive [+] or negative [-]) were determined from surgical pathology reports. The cancers were categorized into low grade (grades 1 or 2) and high grade (grade 3). Correlation of ultrasound features of the cancers to their histological grade and receptor status was performed. RESULTS: There were 47 low-grade and 29 high-grade cancers. There was a significant difference in margin and posterior features between the low and high grade, ER + and ER-, and PR + and PR- (all P < .05), but not between HER2 + and HER2- cancers (both P > .05). There was no significant difference in shape and vascularity among the different subtypes (all P > .05). Spiculated margin was significantly associated with low-grade, ER+, PR + status; angular margin with high grade; microlobulated margin with ER- status; shadowing with PR + status; and enhancement with high grade, ER- status (all P < .05, all odds ratios ≥ 3.94). CONCLUSIONS: There was significant association of margin and posterior features of breast cancers with their histological grade and receptor status.


Assuntos
Neoplasias da Mama/sangue , Neoplasias da Mama/diagnóstico por imagem , Receptor ErbB-2/sangue , Receptores de Estrogênio/sangue , Receptores de Progesterona/sangue , Ultrassonografia Mamária/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Biomarcadores Tumorais/sangue , Mama/diagnóstico por imagem , Mama/patologia , Neoplasias da Mama/patologia , Feminino , Humanos , Pessoa de Meia-Idade , Gradação de Tumores , Estudos Prospectivos
14.
J Am Geriatr Soc ; 65(2): 364-372, 2017 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-27858951

RESUMO

OBJECTIVES: To investigate the effects of an occupational therapy fall reduction home visit program for older adults admitted to the emergency department (ED) for a fall and discharged directly home. DESIGN: Single-blind, multicenter, randomized, controlled trial. SETTINGS: EDs in three acute care hospitals in Hong Kong. PARTICIPANTS: Individuals aged 65 and older who had fallen (N = 311). INTERVENTIONS: After screening for eligibility, 204 consenting individuals were randomly assigned to an intervention group (IG) and received a single home visit from an occupational therapist (OT) within 2 weeks after discharge from the hospital or a control group (CG) and received a well-wishing visit from a research assistant not trained in fall prevention. MEASUREMENTS: Both groups were followed for 12 months through telephone calls made every 2 weeks by blinded assessors with a focus on the frequency of falls. Another blinded assessor followed up on their status with telephone calls 4, 8, and 12 months after ED discharge. Prospective fall records on hospital admissions were retrieved from electronic databases; 198 individuals were followed for 1 year on an intention-to-treat basis. RESULTS: The percentage of fallers over 1 year was 13.7% in the IG (n = 95) and 20.4% in the CG (n = 103). There were significant differences in the number of fallers (P = .03) and the number of falls (P = .02) between the two groups over 6 months. Significant differences were found in survival analysis for first fall at 6 months (log-rank test 5.052, P = .02) but not 9 or 12 months. CONCLUSION: One OT visit after a fall was more effective than a well-wishing visit at reducing future falls at 6 months. A booster OT visit at 6 months is suggested.


Assuntos
Acidentes por Quedas/prevenção & controle , Acidentes por Quedas/estatística & dados numéricos , Visita Domiciliar , Terapia Ocupacional , Prevenção Secundária , Idoso , Serviço Hospitalar de Emergência , Feminino , Seguimentos , Hong Kong , Humanos , Masculino , Método Simples-Cego
15.
Acad Radiol ; 22(3): 269-77, 2015 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-25666048

RESUMO

RATIONALE AND OBJECTIVES: To correlate prognostic histologic features and immunohistochemical biomarkers of breast cancer with quantitative shear wave elastography (SWE) parameters. MATERIALS AND METHODS: B-mode ultrasound (US) and SWE were performed before core biopsy on 72 cancers in 68 patients. Mean cancer size was determined from US. Histologic grade, lymph node status, lymphovascular invasion (LVI), histologic type, and immunohistochemical biomarkers (estrogen receptor, progesterone receptor, human epidermal growth factor receptor 2 [HER2]) were determined from surgical pathology reports. Correlation between these features and quantitative SWE parameters (mean elasticity [E mean], maximum elasticity [E max], and elasticity ratio [E ratio]) was made. RESULTS: There was significant correlation of mean cancer size with E mean, E max, and E ratio (correlation, 0.492, 0.500, and 0.435, respectively; all P < .001). Lymph node involvement was associated with significantly higher E max (P = .040). LVI was associated with significantly higher E mean, E max, and E ratio (P = .002, .004, and .042, respectively). There was no significant correlation of histologic grade with SWE parameters. HER2+ cancers were associated with significantly higher E ratio (P = .030). In multivariate analysis, only mean cancer size was significantly correlated with E mean and E max (P < .001). CONCLUSIONS: There was significant correlation of cancer size with SWE parameters. There was significant correlation of lymph node status and LVI with SWE, but only on univariate analysis. SWE has the potential to provide prognostic information of breast cancer in a noninvasive manner, but further study is required.


Assuntos
Neoplasias da Mama/diagnóstico por imagem , Neoplasias da Mama/metabolismo , Técnicas de Imagem por Elasticidade , Ultrassonografia Mamária , Adulto , Idoso , Idoso de 80 Anos ou mais , Biomarcadores/metabolismo , Biópsia , Neoplasias da Mama/patologia , Feminino , Humanos , Pessoa de Meia-Idade , Prognóstico , Estudos Prospectivos , Receptor ErbB-2/metabolismo , Receptores de Estrogênio/metabolismo , Receptores de Progesterona/metabolismo , Reprodutibilidade dos Testes
16.
AJR Am J Roentgenol ; 204(1): 49-58, 2015 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-25539237

RESUMO

OBJECTIVE: The purposes of this article are to review the anatomy of the upper gastrointestinal tract; review techniques and contrast agents used in the fluoroscopic examination of the oropharynx and hypopharynx; provide a pictorial review of some important causes of oropharyngeal dysphagia; and link these causes to key findings in the clinical history to assist in establishing a clinical diagnosis. CONCLUSION: Many important causes and presentations of oropharyngeal dysphagia are sometimes overlooked during conventional upper gastrointestinal studies. Videofluoroscopic evaluation for assessment of both structural abnormalities and motility disorders of the oropharynx by use of various compositions of barium contrast medium is the standard of practice. Using best-practices radiographic techniques and having knowledge of swallowing mechanisms and various diseases are important for assessment of dysphagia. Dynamic fluoroscopic imaging remains an essential tool for assessing functional disorders of swallowing. Detailed videofluoroscopic assessment can guide treatment decisions with the goal of decreasing the secondary complications of dysphagia.


Assuntos
Transtornos de Deglutição/diagnóstico por imagem , Transtornos de Deglutição/etiologia , Fluoroscopia/métodos , Intensificação de Imagem Radiográfica/métodos , Adulto , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade
17.
AJR Am J Roentgenol ; 203(3): W328-36, 2014 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-25148191

RESUMO

OBJECTIVE: The purpose of this article is to assess the diagnostic performance of quantitative shear wave elastography in the evaluation of solid breast masses and to determine the most discriminatory parameter. SUBJECTS AND METHODS: B-mode ultrasound and shear wave elastography were performed before core biopsy of 123 masses in 112 women. The diagnostic performance of ultrasound and quantitative shear wave elastography parameters (mean elasticity, maximum elasticity, and elasticity ratio) were compared. The added effect of shear wave elastography on the performance of ultrasound was determined. RESULTS: The mean elasticity, maximum elasticity, and elasticity ratio were 24.8 kPa, 30.3 kPa, and 1.90, respectively, for 79 benign masses and 130.7 kPa, 154.9 kPa, and 11.52, respectively, for 44 malignant masses (p < 0.001). The optimal cutoff value for each parameter was determined to be 42.5 kPa, 46.7 kPa, and 3.56, respectively. The AUC of each shear wave elastography parameter was higher than that of ultrasound (p < 0.001); the AUC value for the elasticity ratio (0.943) was the highest. By adding shear wave elastography parameters to the evaluation of BI-RADS category 4a masses, about 90% of masses could be downgraded to BI-RADS category 3. The numbers of downgraded masses were 40 of 44 (91%) for mean elasticity, 39 of 44 (89%) for maximum elasticity, and 42 of 44 (95%) for elasticity ratio. The numbers of correctly downgraded masses were 39 of 40 (98%) for mean elasticity, 38 of 39 (97%) for maximum elasticity, and 41 of 42 (98%) for elasticity ratio. There was improvement in the diagnostic performance of ultrasound of mass assessment with shear wave elastography parameters added to BI-RADS category 4a masses compared with ultrasound alone. Combined ultrasound and elasticity ratio had the highest improvement, from 35.44% to 87.34% for specificity, from 45.74% to 80.77% for positive predictive value, and from 57.72% to 90.24% for accuracy (p < 0.0001). The AUC of combined ultrasound and elasticity ratio (0.914) was the highest compared with the other combined parameters. CONCLUSION: There was a statistically significant difference in the values of the quantitative shear wave elastography parameters of benign and malignant solid breast masses. By adding shear wave elastography parameters to BI-RADS category 4a masses, we found that about 90% of them could be correctly downgraded to BI-RADS category 3, thereby avoiding biopsy. Elasticity ratio (cutoff, 3.56) appeared to be the most discriminatory parameter.


Assuntos
Neoplasias da Mama/diagnóstico por imagem , Técnicas de Imagem por Elasticidade/métodos , Aumento da Imagem/métodos , Interpretação de Imagem Assistida por Computador/métodos , Ultrassonografia Mamária/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Algoritmos , Neoplasias da Mama/fisiopatologia , Análise Discriminante , Módulo de Elasticidade , Feminino , Humanos , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA