Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
1.
Heart Rhythm ; 20(2): 252-260, 2023 02.
Artigo em Inglês | MEDLINE | ID: mdl-36309156

RESUMO

BACKGROUND: In repaired tetralogy of Fallot (TOF), little is known about characteristics of patients with rapid ventricular tachycardia (VT). Also, whether patients with a first episode of nonrapid VT may subsequently develop rapid VT or ventricular fibrillation (VF) has not been addressed. OBJECTIVES: The objectives of this study were to compare patients with rapid VT/VF with those with nonrapid VT and to assess the evolution of VT cycle lengths (VTCLs) overtime. METHODS: Data were analyzed from a nationwide registry including all patients with TOF and implantable cardioverter-defibrillator (ICD) since 2000. Patients with ≥1 VT episode with VTCL ≤250 ms (240 beats/min) formed the rapid VT/VF group. RESULTS: Of 144 patients (mean age 42.0 ± 12.7 years; 104 [72%] men), 61 (42%) had at least 1 VT/VF episode, including 28 patients with rapid VT/VF (46%), during a median follow-up of 6.3 years (interquartile range 2.2-10.3 years). Compared with patients in the nonrapid VT group, those in the rapid VT/VF group were significantly younger at ICD implantation (35.2 ± 12.6 years vs 41.5 ± 11.2 years; P = .04), had more frequently a history of cardiac arrest (8 [29%] vs 2 [6%]; P = .02), less frequently a history of atrial arrhythmia (11 [42%] vs 22 [69%]; P = .004), and higher right ventricular ejection fraction (43.3% ± 10.3% vs 36.6% ± 11.2%; P = .04). The median VTCL of VT/VF episodes was 325 ms (interquartile range 235-429 ms). None of the patients with a first documented nonrapid VT episode had rapid VT/VF during follow-up. CONCLUSION: Patients with TOF and rapid VT/VF had distinct clinical characteristics. The relatively low variation of VTCL over time suggests a room for catheter ablation without a backup ICD in selected patients with well-tolerated VT.


Assuntos
Desfibriladores Implantáveis , Taquicardia Ventricular , Tetralogia de Fallot , Masculino , Humanos , Adulto , Pessoa de Meia-Idade , Feminino , Volume Sistólico , Tetralogia de Fallot/complicações , Tetralogia de Fallot/cirurgia , Seguimentos , Função Ventricular Direita , Taquicardia Ventricular/epidemiologia , Taquicardia Ventricular/etiologia , Taquicardia Ventricular/terapia , Fibrilação Ventricular
2.
JACC Clin Electrophysiol ; 8(10): 1304-1314, 2022 10.
Artigo em Inglês | MEDLINE | ID: mdl-36266008

RESUMO

BACKGROUND: Women with congenital heart disease at high risk for sudden cardiac death have been poorly studied thus far. OBJECTIVES: The aim of this study was to assess sex-related differences in patients with tetralogy of Fallot (TOF) and implantable cardioverter-defibrillators (ICDs). METHODS: Data were analyzed from the DAI-T4F (French National Registry of Patients With Tetralogy of Fallot and Implantable Cardioverter Defibrillator) cohort study, which has prospectively enrolled all patients with TOF with ICDs in France since 2010. Clinical events were centrally adjudicated by a blinded committee. RESULTS: A total of 165 patients (mean age 42.2 ± 13.3 years) were enrolled from 40 centers, including 49 women (29.7%). Among the 9,692 patients with TOF recorded in the national database, the proportion of women with ICDs was estimated to be 1.1% (95% CI: 0.8%-1.5%) vs 2.2% (95% CI: 1.8%-2.6%) in men (P < 0.001). The clinical profiles of patients at implantation, including the number of risk factors for ventricular arrhythmias, were similar between women and men. During a median follow-up period of 6.8 years (IQR: 2.5-11.4 years), 78 patients (47.3%) received at least 1 appropriate ICD therapy, without significant difference in annual incidences between women (12.1%) and men (9.9%) (HR: 1.22; 95% CI: 0.76-1.97; P = 0.40). The risk for overall ICD-related complications was similar in women and men (HR: 1.33; 95% CI: 0.81-2.19; P = 0.30), with 24 women (49.0%) experiencing at least 1 complication. CONCLUSIONS: Our findings suggest that women with TOF at high risk for sudden cardiac death have similar benefit/risk balance from ICD therapy compared with men. Whether ICD therapy is equally offered to at-risk women vs men warrants further evaluation in TOF as well as in other congenital heart disease populations. (French National Registry of Patients With Tetralogy of Fallot and Implantable Cardioverter Defibrillator [DAI-T4F]; NCT03837574).


Assuntos
Desfibriladores Implantáveis , Cardiopatias Congênitas , Tetralogia de Fallot , Humanos , Feminino , Masculino , Adulto , Pessoa de Meia-Idade , Desfibriladores Implantáveis/efeitos adversos , Tetralogia de Fallot/complicações , Estudos de Coortes , Caracteres Sexuais , Morte Súbita Cardíaca/epidemiologia , Morte Súbita Cardíaca/prevenção & controle , Morte Súbita Cardíaca/etiologia , Cardiopatias Congênitas/complicações
3.
JACC Clin Electrophysiol ; 7(10): 1285-1293, 2021 10.
Artigo em Inglês | MEDLINE | ID: mdl-33933408

RESUMO

OBJECTIVES: This study aimed to assess the impact of pulmonary valve replacement (PVR) on ventricular arrhythmias burden in a population of tetralogy of Fallot (TOF) patients with continuous cardiac monitoring by implantable cardioverter-defibrillators (ICDs). BACKGROUND: Sudden cardiac death is a major cause of death in TOF, and right ventricular overload is commonly considered to be a potential trigger for ventricular arrhythmias. METHODS: Data were analyzed from a nationwide French ongoing study (DAI-T4F) including all TOF patients with an ICD since 2000. Survival data with recurrent events were used to compare the burden of appropriate ICD therapies before and after PVR in patients who underwent PVR over the study period. RESULTS: A total of 165 patients (mean age 42.2 ± 13.3 years, 70.1% male) were included from 40 centers. Over a median follow-up period of 6.8 (interquartile range: 2.5 to 11.4) years, 26 patients (15.8%) underwent PVR. Among those patients, 18 (69.2%) experienced at least 1 appropriate ICD therapy. When considering all ICD therapies delivered before (n = 62) and after (n = 16) PVR, the burden of appropriate ICD therapies was significantly lower after PVR (HR: 0.21; 95% confidence interval [CI]: 0.08 to 0.56; p = 0.002). Respective appropriate ICD therapies rates per 100 person-years were 44.0 (95% CI: 35.7 to 52.5) before and 13.2 (95% CI: 7.7 to 20.5) after PVR (p < 0.001). In the overall cohort, PVR before ICD implantation was also independently associated with a lower risk of appropriate ICD therapy in primary prevention patients (HR: 0.29 [95% CI: 0.10 to 0.89]; p = 0.031). CONCLUSIONS: In this cohort of high-risk TOF patients implanted with an ICD, the burden of appropriate ICD therapies was significantly reduced after PVR. While optimal indications and timing for PVR are debated, these findings suggest the importance of considering ventricular arrhythmias in the overall decision-making process. (French National Registry of Patients With Tetralogy of Fallot and Implantable Cardioverter Defibrillator [DAI-T4F]; NCT03837574).


Assuntos
Procedimentos Cirúrgicos Cardíacos , Desfibriladores Implantáveis , Valva Pulmonar , Tetralogia de Fallot , Adulto , Arritmias Cardíacas/terapia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Valva Pulmonar/cirurgia , Tetralogia de Fallot/cirurgia
4.
Circulation ; 142(17): 1612-1622, 2020 10 27.
Artigo em Inglês | MEDLINE | ID: mdl-32998542

RESUMO

BACKGROUND: Tetralogy of Fallot (TOF) is the most common cyanotic congenital heart disease, and sudden cardiac death represents an important mode of death in these patients. Data evaluating the implantable cardioverter defibrillator (ICD) in this patient population remain scarce. METHODS: A Nationwide French Registry including all patients with tetralogy of Fallot with an ICD was initiated in 2010 by the French Institute of Health and Medical Research. The primary time to event end point was the time from ICD implantation to first appropriate ICD therapy. Secondary outcomes included ICD-related complications, heart transplantation, and death. Clinical events were centrally adjudicated by a blinded committee. RESULTS: A total of 165 patients (mean age, 42.2±13.3 years, 70.1% males) were included from 40 centers, including 104 (63.0%) in secondary prevention. During a median (interquartile range) follow-up of 6.8 (2.5-11.4) years, 78 (47.3%) patients received at least 1 appropriate ICD therapy. The annual incidence of the primary outcome was 10.5% (7.1% and 12.5% in primary and secondary prevention, respectively; P=0.03). Overall, 71 (43.0%) patients presented with at least 1 ICD complication, including inappropriate shocks in 42 (25.5%) patients and lead dysfunction in 36 (21.8%) patients. Among 61 (37.0%) patients in primary prevention, the annual rate of appropriate ICD therapies was 4.1%, 5.3%, 9.5%, and 13.3% in patients with, respectively, 0, 1, 2, or ≥3 guidelines-recommended risk factors. QRS fragmentation was the only independent predictor of appropriate ICD therapies (hazard ratio, 3.47 [95% CI, 1.19-10.11]), and its integration in a model with current criteria increased the 5-year time-dependent area under the curve from 0.68 to 0.81 (P=0.006). Patients with congestive heart failure or reduced left ventricular ejection fraction had a higher risk of nonarrhythmic death or heart transplantation (hazard ratio, 11.01 [95% CI, 2.96-40.95]). CONCLUSIONS: Patients with tetralogy of Fallot and an ICD experience high rates of appropriate therapies, including those implanted in primary prevention. The considerable long-term burden of ICD-related complications, however, underlines the need for careful candidate selection. A combination of easy-to-use criteria including QRS fragmentation might improve risk stratification. Registration: URL: https://www.clinicaltrials.gov; Unique identifier: NCT03837574.


Assuntos
Desfibriladores Implantáveis/tendências , Tetralogia de Fallot/epidemiologia , Tetralogia de Fallot/terapia , Adulto , Feminino , Seguimentos , Humanos , Masculino , Sistema de Registros
5.
Arch Cardiovasc Dis ; 102(10): 685-96, 2009 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-19913770

RESUMO

BACKGROUND: Meta-analyses have confirmed the high performance of multislice computed tomography (MSCT) in coronary stenosis detection. Recent reports have described the study of left ventricular anatomy and function and coronary venous anatomy with MSCT. AIMS: We sought to compare, in patients with cardiomyopathy of unknown origin, the performance of MSCT versus angiography for significant coronary artery disease detection and versus transthoracic echocardiography (TTE) for left ventricular anatomy and function evaluation, and to assess its ability to characterize coronary venous anatomy. METHODS: Fifty-nine patients with cardiomyopathy (left ventricular ejection fraction [LVEF] less than or equal to 40%) of unknown origin, in sinus rhythm, underwent MSCT, TTE and coronary angiography. RESULTS: Twenty-four (3%) of 724 analysable coronary segments (97%) and 12 (20%) patients had significant coronary artery disease. MSCT sensitivity, specificity, and positive and negative predictive values for coronary artery disease detection were 87.5%, 98.5%, 67.7% and 99.6% in the per-segment assessment and 100%, 91%, 75% and 100% in the per-patient evaluation, respectively. Statistical analyses showed good agreement between MSCT and TTE in LVEF measurement (33+/-10% vs 32+/-11%, p=0.4, mean difference=0.7%, limits of agreement+/-13.6%) and a small LVED diameter overestimation (65.0+/-9.3mm vs 63.6+/-9.4mm, p=0.03). MSCT allowed detection of the posterolateral vein in 86% of cases. CONCLUSIONS: In selected patients presenting with idiopathic cardiomyopathy, MSCT is accurate for coronary artery disease detection and is a useful coronary venous imaging tool. MSCT studies of left ventricular function and morphology were mostly concordant with TTE measurements.


Assuntos
Cardiomiopatias/diagnóstico por imagem , Angiografia Coronária , Seio Coronário/diagnóstico por imagem , Estenose Coronária/diagnóstico por imagem , Ventrículos do Coração/diagnóstico por imagem , Tomografia Computadorizada por Raios X , Disfunção Ventricular Esquerda/diagnóstico por imagem , Adulto , Idoso , Cardiomiopatias/etiologia , Cardiomiopatias/fisiopatologia , Estenose Coronária/complicações , Estenose Coronária/fisiopatologia , Ecocardiografia , Feminino , Ventrículos do Coração/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Estudos Prospectivos , Sensibilidade e Especificidade , Índice de Gravidade de Doença , Volume Sistólico , Disfunção Ventricular Esquerda/etiologia , Disfunção Ventricular Esquerda/fisiopatologia , Função Ventricular Esquerda , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS