Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
J Clin Med ; 13(8)2024 Apr 19.
Artigo em Inglês | MEDLINE | ID: mdl-38673669

RESUMO

(1) Background: DIEP-based breast reconstruction necessitates wide undermining at the abdominal donor site, creating large wound areas. Flap harvesting is usually conducted using electrosurgical dissection devices. This study sought to compare the clinical outcomes in patients after using the PEAK PlasmaBlade (PPB) versus monopolar electrocautery (MPE). (2) Methods: This retrospective cohort study included 128 patients with DIEP-based breast reconstruction. Patient characteristics and information on the postoperative course were collected and a comparative evaluation was conducted. (3) Results: The MPE group exhibited significantly (p* = 0.0324) higher abdominal drainage volume (351.11 ± 185.96 mL) compared to the PPB group (279.38 ± 183.38 mL). A subgroup analysis demonstrated that PPB significantly reduced postoperative wound fluid in patients with BMI > 30 kg/m2 (p* = 0.0284), without prior neoadjuvant chemotherapy (p** = 0.0041), and among non-smokers (p = 0.0046). Furthermore, postoperative pain was significantly (p**** < 0.0001) lower in the PPB cohort. (4) Conclusions: This study confirms the non-inferiority of the PEAK PlasmaBlade to conventional electrocautery for abdominal flap harvesting. The PPB demonstrated advantages, notably reduced drainage volume and lower postoperative pain levels. Recognizing patient subsets that benefit more from the PPB highlights the importance of personalized device selection based on patient characteristics.

2.
Cancers (Basel) ; 15(9)2023 Apr 25.
Artigo em Inglês | MEDLINE | ID: mdl-37173928

RESUMO

The globally increasing incidence of cutaneous malignancies leads, in parallel, to increasing numbers of locally advanced skin cancer resulting in reconstructive surgery. Reasons for locally advanced skin cancer may be a patient's neglect or aggressive tumor growth, such as desmoplastic growth or perineural invasion. This study investigates characteristics of cutaneous malignancies requiring microsurgical reconstruction with the aim of identifying possible pitfalls and improving diagnostic and therapeutic processes. A retrospective data analysis from 2015 to 2020 was conducted. Seventeen patients (n = 17) were included. The mean age at reconstructive surgery was 68.5 (±13) years. The majority of patients (14/17, 82%) presented with recurrent skin cancer. The most common histological entity was squamous cell carcinoma (10/17, 59%). All neoplasms showed at least one of the following histopathological characteristics: desmoplastic growth (12/17, 71%), perineural invasion (6/17, 35%), or tumor thickness of at least 6 mm (9/17, 53%). The mean number of surgical resections until cancer-free resection margins (R0) were achieved was 2.4 (±0.7). The local recurrence rate and the rate of distant metastases were 36%. Identified high-risk neoplastic characteristics, such as desmoplastic growth, perineural invasion, and a tumor depth of at least 6 mm, require a more extensive surgical treatment without concerns about defect size.

3.
J Clin Med ; 12(3)2023 Jan 17.
Artigo em Inglês | MEDLINE | ID: mdl-36769386

RESUMO

(1) Background: This work aimed to conduct a comparative study, providing long-term data about patient-reported outcome measures and donor site scar assessments, as well as an aesthetic evaluation of the reconstructed breasts in patients with DIEP versus PAP flap breast reconstruction. (2) Methods: This prospective, single-center, matched cohort study included a total of 36 patients after DIEP and PAP flap breast reconstruction. The evaluation was carried out using the Breast-Q and POSAS questionnaire, as well as the Breast Aesthetic Scale for cosmetic analysis, by four plastic surgeons. (3) Results: The postoperative Breast-Q evaluation revealed no significant differences between both patient groups for the categories of the physical well-being of the donor site, the physical well-being of the breast, and satisfaction with the breast. A scar evaluation of the donor site region showed equivalent results for the thigh and abdomen regions, concerning the overall opinion of the patients and the observers. There was no significant difference between both methods of reconstruction for all aspects of breast aesthetics. (4) Conclusions: Similar results for donor site morbidity, scar quality, and the aesthetic outcome of the breasts in both the DIEP and PAP patient groups have been demonstrated. Hence, in those cases suitable for both types of reconstruction, the decision can be based on factors such as patients' lifestyles, leisure activities, and preferences.

4.
J Clin Med ; 12(4)2023 Feb 07.
Artigo em Inglês | MEDLINE | ID: mdl-36835850

RESUMO

The most common long-term complication of silicone breast implants (SMI) remains capsular fibrosis. The etiology of this exaggerated implant encapsulation is multifactorial but primarily induced by the host response towards the foreign material silicone. Identified risk factors include specific implant topographies. Of note, breast implant-associated anaplastic large cell lymphoma (BIA-ALCL) has only been observed in response to textured surface implants. We hypothesize that reduction of SMI surface roughness causes less host response and, hence, better cosmetic outcomes with fewer complications for the patient. A total of 7 patients received the routinely used CPX®4 breast expander (~60 µM Ra) and the novel SmoothSilk® (~4 µM Ra), fixed prepectoral with a titanized mesh pocket and randomized to the left or right breast after bilateral prophylactic NSME (nipple-sparing mastectomy). We aimed to compare the postoperative outcome regarding capsule thickness, seroma formation, rippling, implant dislocation as well as comfortability and practicability. Our analysis shows that surface roughness is an influential parameter in controlling fibrotic implant encapsulation. Compared intra-individually for the first time in patients, our data confirm an improved biocompatibility with minor capsule formation around SmoothSilk® implants with an average shell roughness of 4 µM and in addition an amplification of host response by titanized implant pockets.

5.
Curr Oncol ; 29(8): 5682-5697, 2022 08 11.
Artigo em Inglês | MEDLINE | ID: mdl-36005186

RESUMO

The transverse myocutaneous gracilis (TMG) and the profunda artery perforator (PAP) flap are both safe choices for autologous breast reconstruction originating from the same donor region in the upper thigh. We aimed to compare the post-operative outcome regarding donor-site morbidity and quality of life. We included 18 patients who had undergone autologous breast reconstruction with a PAP flap (n = 27 flaps). Prospective evaluation of donor-site morbidity was performed by applying the same questionnaire that had already been established in a previous study evaluating TMG flap (n = 25 flaps) outcome, and results were compared. Comparison of the two patient groups showed equivalent results concerning patient-reported visibility of the donor-site scar and thigh symmetry. Still, the TMG group was significantly more satisfied with the scar (p = 0.015) and its position (p = 0.001). No difference was found regarding the ability to sit for prolonged periods. Donor-site wound complications were seen more frequently in the PAP group (29.6%) than in the TMG group (4.0%). Both groups expressed rather high satisfaction with their quality of life. Both flaps show minimal functional donor-site morbidity and high patient satisfaction. To minimize wound healing problems in PAP patients, thorough planning of the skin paddle is necessary.


Assuntos
Mamoplastia , Retalho Miocutâneo , Cicatriz , Humanos , Mamoplastia/métodos , Morbidade , Retalho Miocutâneo/transplante , Qualidade de Vida
6.
Breast Care (Basel) ; 17(5): 450-459, 2022 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-36684404

RESUMO

Introduction: The profunda artery perforator (PAP) flap represents a valuable alternative to the deep inferior epigastric artery perforator flap which, nowadays, is considered the golden standard for autologous breast reconstruction. The goal of this study was to evaluate the long-term satisfaction, functional outcomes of the donor site following PAP flap-based breast reconstruction and to present our personal learning experience along with suggestions for technique refinements. Methods: In this prospective single-center appraisal, 18 patients who underwent PAP flap-based breast reconstruction between January 2016 and November 2019 were enrolled. The Patient and Observer Scar Assessment Scale (POSAS) and the Breast-Q questionnaire were employed to evaluate the results 12 months postoperative. Data were analyzed with the Q-Score program. Complications were recorded in the medical database and classified with the Clavien-Dindo classification. Results: In the questionable time frame, 164 female patients underwent free flap breast reconstruction. Of those, 18 patients that received PAP flaps (9 bilateral) were included in this study. We recorded one flap loss because of venous failure. Most complications concerned the donor site, including hematoma, seroma, and wound healing problems. Patients' satisfaction was high at 12 months post-surgery, despite critical evaluation of the donor site scar. Conclusion: The PAP flap serves as an excellent option for breast reconstruction in patients who do not have abundant abdominal tissue. The overall clinical outcome was good and patients' evaluation showed high satisfaction after 12 months despite high complication rates. Modifications in planning and flap harvesting might improve the donor site outcome and the overall complication rate.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA