Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 87
Filtrar
1.
Endosc Int Open ; 12(10): E1143-E1149, 2024 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-39398449

RESUMO

Background and study aims Although outcomes of lumen-apposing metal stents (LAMS) placement in native anatomy have been reported, data on LAMS placement in surgically altered anatomy (SAA) are sparse. We aimed to assess outcomes of LAMS placement in patients with SAA for different indications. Patients and methods This was an international, multicenter, retrospective, observational study at 25 tertiary care centers through November 2023. Consecutive patients with SAA who underwent LAMS placement were included. The primary outcome was technical success defined as correct placement of LAMS. Secondary outcomes were clinical success and safety. Results Two hundred and seventy patients (125 males; average age 61 ± 15 years) underwent LAMS placement with SAA. Procedures included EUS-directed transgastric ERCP (EDGE) and EUS-directed transenteric ERCP (EDEE) (n = 82), EUS-guided entero-enterostomy (n = 81), EUS-guided biliary drainage (n = 57), EUS-guided drainage of peri-pancreatic fluid collections (n = 48), and EUS-guided pancreaticogastrostomy (n = 2). Most cases utilized AXIOS stents (n = 255) compared with SPAXUS stents (n = 15). Overall, technical success was 98%, clinical success was 97%, and the adverse event (AE) rate was 12%. Using AGREE classification, five events were rated as Grade II, 21 events as Grade IIIa, and six events as IIIb. No difference in AEs were noted among stent types ( P = 0.52). Conclusions This study shows that placement of LAMS is associated with high technical and clinical success rates in patients with SAA. However, the rate of AEs is noteworthy, and thus, these procedures should be performed by expert endoscopists at tertiary centers.

3.
Dig Liver Dis ; 2024 Jul 18.
Artigo em Inglês | MEDLINE | ID: mdl-39030137

RESUMO

Pancreatic fluid collections (PFCs), including pancreatic pseudocysts (PPs) and walled-off pancreatic necrosis (WON), are common complications of pancreatitis and pancreatic surgery. Historically, the treatment of these conditions has relied on surgical and radiological approaches. The treatment of patients with PFCs has already focused toward an endoscopy-based approach, and with the development of dedicated lumen-apposing metal stents (LAMS), it has almost totally shifted towards interventional Endoscopic Ultrasound (EUS)-guided procedures. However, there is still limited consensus on several aspects of PFCs treatment within the multidisciplinary management. The interventional endoscopy and ultrasound (i-EUS) group is an Italian network of clinicians and scientists with special interest in biliopancreatic interventional endoscopy, especially interventional EUS. This manuscript focuses on the second part of the results of a consensus conference organized by i-EUS, with the aim of providing evidence-based guidance on several intra- and post-procedural aspects of PFCs drainage, such as clinical management and follow-up.

4.
Dig Liver Dis ; 56(10): 1663-1674, 2024 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-39048418

RESUMO

Pancreatic fluid collections (PFCs), including pancreatic pseudocysts (PPs) and walled-off pancreatic necrosis (WON), are common complications of pancreatitis and pancreatic surgery. Historically, the treatment of these conditions has relied on surgical and radiological approaches; however, it has later shifted toward an endoscopy-based approach. With the development of dedicated lumen-apposing metal stents (LAMS), interventional Endoscopic Ultrasound (EUS)-guided procedures have become the standard approach for PFC drainage. However, there is still limited consensus on several aspects of the multidisciplinary management of PFCs. The interventional endoscopy and ultrasound (i-EUS) group is an Italian network of clinicians and scientists with special interest in biliopancreatic interventional endoscopy, especially interventional EUS. This manuscript describes the first part of the results of a consensus conference organized by i-EUS with the aim of providing evidence-based guidance on aspects such as indications for treating PFCs, the timing of intervention, and different technical strategies for managing patients with PFCs.


Assuntos
Drenagem , Endossonografia , Pseudocisto Pancreático , Humanos , Consenso , Drenagem/métodos , Drenagem/normas , Endossonografia/métodos , Endossonografia/normas , Itália , Pseudocisto Pancreático/terapia , Pseudocisto Pancreático/diagnóstico por imagem , Pseudocisto Pancreático/cirurgia , Pancreatite/terapia , Stents , Ultrassonografia de Intervenção/métodos , Ultrassonografia de Intervenção/normas , Conferências de Consenso como Assunto
5.
Endosc Int Open ; 12(4): E467-E473, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38585018

RESUMO

Background and study aims The optimal number of needle passes during endoscopic ultrasound-guided fine-needle biopsy (EUS-FNB) is not yet established. We aimed to perform a per-pass analysis of the diagnostic accuracy of EUS-FNB of solid pancreatic lesions using a 22G Franseen needle. Patients and methods Consecutive patients with solid pancreatic lesions referred to 11 Italian centers were prospectively enrolled. Three needle passes were performed; specimens were collected after each pass and processed individually as standard histology following macroscopic on-site evaluation (MOSE) by the endoscopist. The primary endpoint was diagnostic accuracy of each sequential pass. Final diagnosis was established based on surgical pathology or a clinical course of at least 6 months. Secondary endpoints were specimen adequacy, MOSE reliability, factors impacting diagnostic accuracy, and procedure-related adverse events. Results A total of 504 samples from 168 patients were evaluated. Diagnostic accuracy was 90.5% (85.0%-94.1%) after one pass and 97.6% (94.1%-99.3%) after two passes ( P =0.01). Similarly, diagnostic sensitivity and sample adequacy were significantly higher adding the second needle pass (90.2%, 84.6%-94.3% vs 97.5%, 93.8%-99.3%, P =0.009 and 91.1%, 85.7%-94.9% vs 98.2%, 95.8%-99.3%, P =0.009, one pass vs two passes, respectively). Accuracy, sensitivity, and adequacy remained the same after the third pass. The concordance between MOSE and histological evaluation was 89.9%. The number of passes was the only factor associated with accuracy. One case of mild acute pancreatitis (0.6%) was managed conservatively. Conclusions At least two passes should be performed for the diagnosis of solid pancreatic lesions. MOSE is a reliable tool to predict the histological adequacy of specimens.

7.
Endoscopy ; 56(4): 249-257, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38237633

RESUMO

INTRODUCTION: Endoscopic ultrasound (EUS)-guided drainage of symptomatic pancreatic fluid collections (PFCs) using the Hot-Axios device has recently been associated with a significant risk of bleeding. This adverse event (AE) seems to occur less frequently with the use of a different device, the Spaxus stent. The aim of the current study was to compare the rates of bleeding between the two stents. METHODS: Patients admitted for treatment of PFCs by EUS plus lumen-apposing metal stent in 18 endoscopy referral centers between 10 July 2019 and 28 February 2022 were identified and their outcomes compared using a propensity-matching analysis. RESULTS: 363 patients were evaluated. After a 1-to-1 propensity score match, 264 patients were selected (132 per group). The technical and clinical success rates were comparable between the two groups. Significantly more bleeding requiring transfusion and/or intervention occurred in the Hot-Axios group than in the Spaxus group (6.8% vs. 1.5%; P = 0.03); stent type was a significant predictor of bleeding in both univariate and multivariate regression analyses (P = 0.03 and 0.04, respectively). Bleeding necessitating arterial embolization did not however differ significantly between the two groups (3.0% vs. 0%; P = 0.12). In addition, the Hot-Axios was associated with a significantly higher rate of overall AEs compared with the Spaxus stent (9.8% vs. 3.0%; P = 0.04). CONCLUSION: Our study showed that, in patients with PFCs, bleeding requiring transfusion and/or intervention occurred significantly more frequently with use of the Hot-Axios stent than with the Spaxus stent, although this was not the case for bleeding requiring embolization.


Assuntos
Pâncreas , Pancreatopatias , Humanos , Estudos Retrospectivos , Stents/efeitos adversos , Endossonografia/efeitos adversos , Drenagem/efeitos adversos , Hemorragia/etiologia , Endoscopia Gastrointestinal , Resultado do Tratamento
8.
Gastrointest Endosc ; 99(4): 587-595.e1, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-37951279

RESUMO

BACKGROUND AND AIMS: Ampullary lesions (ALs) of the minor duodenal papilla are extremely rare. Endoscopic papillectomy (EP) is a routinely used treatment for AL of the major duodenal papilla, but the role of EP for minor AL has not been accurately studied. METHODS: We identified 20 patients with ALs of minor duodenal papilla in the multicentric database from the Endoscopic Papillectomy vs Surgical Ampullectomy vs Pancreatitcoduodenectomy for Ampullary Neoplasm study, which included 1422 EPs. We used propensity score matching (nearest-neighbor method) to match these cases with ALs of the major duodenal papilla based on age, sex, histologic subtype, and size of the lesion in a 1:2 ratio. Cohorts were compared by means of chi-square or Fisher exact test as well as Mann-Whitney U test. RESULTS: Propensity score-based matching identified a cohort of 60 (minor papilla 20, major papilla 40) patients with similar baseline characteristics. The most common histologic subtype of lesions of minor papilla was an ampullary adenoma in 12 patients (3 low-grade dysplasia and 9 high-grade dysplasia). Five patients revealed nonneoplastic lesions. Invasive cancer (T1a), adenomyoma, and neuroendocrine neoplasia were each found in 1 case. The rate of complete resection, en-bloc resection, and recurrences were similar between the groups. There were no severe adverse events after EP of lesions of minor papilla. One patient had delayed bleeding that could be treated by endoscopic hemostasis, and 2 patients showed a recurrence in surveillance endoscopy after a median follow-up of 21 months (interquartile range, 12-50 months). CONCLUSIONS: EP is safe and effective in ALs of the minor duodenal papilla. Such lesions could be managed according to guidelines for EP of major duodenal papilla.


Assuntos
Ampola Hepatopancreática , Neoplasias do Ducto Colédoco , Neoplasias Duodenais , Neoplasias Pancreáticas , Humanos , Resultado do Tratamento , Ampola Hepatopancreática/cirurgia , Ampola Hepatopancreática/patologia , Endoscopia Gastrointestinal , Ductos Pancreáticos/patologia , Neoplasias Pancreáticas/patologia , Neoplasias Duodenais/patologia , Neoplasias do Ducto Colédoco/cirurgia , Neoplasias do Ducto Colédoco/patologia , Estudos Retrospectivos
9.
Dig Endosc ; 36(3): 351-358, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-37253185

RESUMO

OBJECTIVES: Endoscopic retrograde cholangiopancreatography (ERCP) represents the gold standard for jaundice palliation in patients with distal malignant biliary obstruction (DMBO). Biliary drainage using electrocautery lumen apposing metal stent (EC-LAMS) is currently a well-established procedure when ERCP fails. In a palliative setting the endoscopic ultrasound-guided gallbladder drainage (EUS-GBD) could represent an easy and valid option. We performed a prospective study with a new EC-LAMS with the primary aim to assess the clinical success rate of EUS-GBD as a first-line approach to the palliation of DMBO. METHODS: In all, 37 consecutive patients undergoing EUS-GBD with a new EC-LAMS were prospectively enrolled. Clinical success was defined as bilirubin level decrease >15% within 24 h and >50% within 14 days after EC-LAMS placement. RESULTS: The mean age was 73.5 ± 10.8 years; there were 17 male patients (45.9%). EC-LAMS placement was technically feasible in all patients (100%) and the clinical success rate was 100%. Four patients (10.8%) experienced adverse events, one bleeding, one food impaction, and two cystic duct obstructions because of disease progression. No stent-related deaths were observed. The mean hospitalization was 7.7 ± 3.4 days. Median overall survival was 4 months (95% confidence interval 1-8). CONCLUSION: Endoscopic ultrasound-guided gallbladder drainage with the new EC-LAMS is a valid option in palliative endoscopic biliary drainage as a first-step approach in low survival patients with malignant jaundice unfit for surgery. A smaller diameter EC-LAMS should be preferred, particularly if the drainage is performed through the stomach, to avoid potential food impaction, which could result in stent dysfunction.


Assuntos
Colestase , Icterícia , Humanos , Masculino , Pessoa de Meia-Idade , Idoso , Idoso de 80 Anos ou mais , Vesícula Biliar , Estudos Prospectivos , Colestase/diagnóstico por imagem , Colestase/etiologia , Colestase/cirurgia , Endossonografia/métodos , Icterícia/complicações , Drenagem/métodos , Stents/efeitos adversos , Colangiopancreatografia Retrógrada Endoscópica/métodos , Ultrassonografia de Intervenção/métodos
10.
Diagnostics (Basel) ; 13(21)2023 Oct 30.
Artigo em Inglês | MEDLINE | ID: mdl-37958236

RESUMO

Aims: Lumen-apposing metal stents (LAMSs) in ultrasonography-guided gallbladder drainage (EUS-GBD) have become increasingly important for high-risk surgical patients. Our study aims to evaluate the technical and clinical success, safety, and feasibility of endoscopic ultrasonography-guided gallbladder drainage using a new dedicated LAMS. Methods: This is a retrospective multicenter study that included all consecutive patients not suitable for surgery who were referred to a tertiary center for EUS-GBD using a new dedicated electrocautery LAMS for acute cholecystitis at eight different centers. Results: Our study included 54 patients with a mean age of 76.48 years (standard deviation: 12.6 years). Out of the 54 endoscopic gallbladder drainages performed, 24 (44.4%) were cholecysto-gastrostomy, and 30 (55.4%) were cholecysto-duodenostomy. The technical success of LAMS placement was 100%, and clinical success was achieved in 23 out of 30 patients (76.67%). Adverse events were observed in two patients (5.6%). Patients were discharged after a median of 5 days post-stenting. Conclusions: EUS-GBD represents a valuable option for high-surgical-risk patients with acute cholecystitis. This new dedicated LAMS has demonstrated a high rate of technical and clinical success, along with a high level of safety.

12.
Neuroendocrinology ; 113(10): 1024-1034, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37369186

RESUMO

INTRODUCTION: Ampullary neuroendocrine neoplasia (NEN) is rare and evidence regarding their management is scarce. This study aimed to describe clinicopathological features, management, and prognosis of ampullary NEN according to their endoscopic or surgical management. METHODS: From a multi-institutional international database, patients treated with either endoscopic papillectomy (EP), transduodenal surgical ampullectomy (TSA), or pancreaticoduodenectomy (PD) for ampullary NEN were included. Clinical features, post-procedure complications, and recurrences were assessed. RESULTS: 65 patients were included, 20 (30.8%) treated with EP, 19 (29.2%) with TSA, and 26 (40%) with PD. Patients were mostly asymptomatic (n = 46; 70.8%). Median tumor size was 17 mm (12-22), tumors were mostly grade 1 (70.8%) and pT2 (55.4%). Two (10%) EP resulted in severe American Society for Gastrointestinal Enterology (ASGE) adverse post-procedure complications and 10 (50%) were R0. Clavien 3-5 complications did not occur after TSA and in 4, including 1 postoperative death (15.4%) of patients after PD, with 17 (89.5%) and 26 R0 resection (100%), respectively. The pN1/2 rate was 51.9% (n = 14) after PD. Tumor size larger than 1 cm (i.e., pT stage >1) was a predictor for R1 resection (p < 0.001). Three-year overall survival and disease-free survival after EP, TSA, and PD were 92%, 68%, 92% and 92%, 85%, 73%, respectively. CONCLUSION: Management of ampullary NEN is challenging. EP should not be performed in lesions larger than 1 cm or with a endoscopic ultrasonography T stage beyond T1. Local resection by TSA seems safe and feasible for lesions without nodal involvement. PD should be preferred for larger ampullary NEN at risk of nodal metastasis.


Assuntos
Ampola Hepatopancreática , Neoplasias do Ducto Colédoco , Neoplasias Duodenais , Tumores Neuroendócrinos , Humanos , Ampola Hepatopancreática/cirurgia , Ampola Hepatopancreática/patologia , Pancreaticoduodenectomia/métodos , Prognóstico , Pancreatectomia , Neoplasias do Ducto Colédoco/cirurgia , Neoplasias do Ducto Colédoco/patologia , Neoplasias Duodenais/cirurgia , Tumores Neuroendócrinos/patologia , Estudos Retrospectivos , Resultado do Tratamento
13.
Diagnostics (Basel) ; 13(12)2023 Jun 14.
Artigo em Inglês | MEDLINE | ID: mdl-37370952

RESUMO

Gastroesophageal reflux disease has a high incidence and prevalence in the general population. Clinical manifestations are heterogenous, and so is the response to medical treatment. Proton pump inhibitors are still the most common agents used to control reflux symptoms and for healing esophagitis, but they are not a one-size-fits-all solution for the disease. Patients with persistent troublesome symptoms despite medical therapy, those experiencing some adverse drug reaction, or those unwilling to take lifelong medications deserve valid alternatives. Anti-reflux Nissen fundoplication is an effective option, but the risk of adverse events has limited its spread. In recent years, advancements in therapeutic endoscopy have been made, and three major endoluminal alternatives are now available, including (1) the delivery of radiofrequency energy to the esophago-gastric junction, (2) transoral incisionless fundoplication (TIF), and (3) anti-reflux mucosal interventions (ARMI) based on mucosal resection (ARMS) and mucosal ablation (ARMA) techniques to remodel the cardia. Endoscopic techniques have shown interesting results, but their diffusion is still limited to expert endoscopists in tertiary centers. This review discusses the state of the art in the endoscopic approach to gastroesophageal reflux disease.

14.
Liver Int ; 43(8): 1783-1792, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-37269164

RESUMO

BACKGROUND: Gastric varices (GVs) are conventionally managed with endoscopic cyanoacrylate (E-CYA) glue injection. Endoscopic ultrasound (EUS)-guided therapy using combination of coils and CYA glue (EUS-CG) is a relatively recent modality. There is limited data comparing the two techniques. METHODOLOGY: This international multicentre study included patients with GV undergoing endotherapy from two Indian and two Italian tertiary care centres. Patients undergoing EUS-CG were compared with propensity-matched E-CYA cases from a cohort of 218 patients. Procedural details such as amount of glue, number of coils used, number of sessions required for obliteration, bleeding after index procedure rates and need for re-intervention were noted. RESULTS: Of 276 patients, 58 (male 42, 72.4%; mean age-44.3 ± 12.1 years) underwent EUS-CG and were compared with 118 propensity-matched cases of E-CYA. In the EUS-CG arm, complete obliteration at 4 weeks was noted in 54 (93.1%) cases. Compared to the E-CYA cohort, EUS-CG arm showed significantly lower number of session (1.0 vs. 1.5; p < 0.0001) requirement, lower subsequent-bleeding episodes (13.8% vs. 39.1%; p < 0.0001) and lower re-intervention (12.1% vs. 50.4%; p < 0.001) rates. On multivariable regression analysis, size of the varix (aOR-1.17; CI 1.08-1.26) and technique of therapy (aOR-14.71; CI 4.32-50.0) were significant predictors of re-bleeding. A maximum GV size >17.5 mm had a 69% predictive accuracy for need for re-intervention. CONCLUSION: Endoscopic ultrasound-guided therapy of GV using coil and CYA glue is a safe technique with better efficacy and lower re-bleeding rates on follow-up compared to the conventional endoscopic CYA therapy.


Assuntos
Varizes Esofágicas e Gástricas , Hemostase Endoscópica , Humanos , Masculino , Varizes Esofágicas e Gástricas/diagnóstico por imagem , Varizes Esofágicas e Gástricas/terapia , Hemorragia Gastrointestinal/diagnóstico por imagem , Hemorragia Gastrointestinal/terapia , Hemostase Endoscópica/métodos , Resultado do Tratamento , Endossonografia/métodos , Cianoacrilatos
15.
J Clin Med ; 12(8)2023 Apr 12.
Artigo em Inglês | MEDLINE | ID: mdl-37109171

RESUMO

Many tumors may secondarily involve the pancreas; however, only retrospective autopic and surgical series are available. We retrospectively collected data from all consecutive patients with histologically confirmed secondary tumors of the pancreas referred to five Italian centers between 2010 and 2021. We described clinical and pathological features, therapeutic approach and treatment outcomes. EUS characteristics of the lesions and the tissue acquisition procedures (needle, passages, histology) were recorded. A total of 116 patients (males/females 69/47; mean age 66.7) with 236 histologically confirmed pancreatic metastases were included; kidney was the most common primary site. EUS was performed to confirm the diagnosis in 205 lesions which presented as predominantly solitary (59), hypoechoic (95) and hypervascular (60), with a heterogeneous (n = 54) pattern and well-defined borders (n = 52). EUS-guided tissue acquisition was performed in 94 patients with an overall accuracy of 97.9%. Histological evaluation was possible in 88.3% of patients, obtaining final diagnosis in all cases. When cytology alone was performed, the final diagnosis was obtained in 83.3% of cases. A total of 67 patients underwent chemo/radiation therapy, and surgery was attempted in 45 (38.8%) patients. Pancreatic metastases are a possible event in the natural history of solid tumors, even long after the diagnosis of the primary site. EUS-guided fine needle biopsy may be suggested to implement the differential diagnosis.

16.
Gastroenterology ; 165(1): 244-251.e3, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-37061169

RESUMO

BACKGROUND & AIMS: Both computer-aided detection (CADe)-assisted and Endocuff-assisted colonoscopy have been found to increase adenoma detection. We investigated the performance of the combination of the 2 tools compared with CADe-assisted colonoscopy alone to detect colorectal neoplasias during colonoscopy in a multicenter randomized trial. METHODS: Men and women undergoing colonoscopy for colorectal cancer screening, polyp surveillance, or clincial indications at 6 centers in Italy and Switzerland were enrolled. Patients were assigned (1:1) to colonoscopy with the combinations of CADe (GI-Genius; Medtronic) and a mucosal exposure device (Endocuff Vision [ECV]; Olympus) or to CADe-assisted colonoscopy alone (control group). All detected lesions were removed and sent to histopathology for diagnosis. The primary outcome was adenoma detection rate (percentage of patients with at least 1 histologically proven adenoma or carcinoma). Secondary outcomes were adenomas detected per colonoscopy, advanced adenomas and serrated lesions detection rate, the rate of unnecessary polypectomies (polyp resection without histologically proven adenomas), and withdrawal time. RESULTS: From July 1, 2021 to May 31, 2022, there were 1316 subjects randomized and eligible for analysis; 660 to the ECV group, 656 to the control group). The adenoma detection rate was significantly higher in the ECV group (49.6%) than in the control group (44.0%) (relative risk, 1.12; 95% CI, 1.00-1.26; P = .04). Adenomas detected per colonoscopy were significantly higher in the ECV group (mean ± SD, 0.94 ± 0.54) than in the control group (0.74 ± 0.21) (incidence rate ratio, 1.26; 95% CI, 1.04-1.54; P = .02). The 2 groups did not differ in term of detection of advanced adenomas and serrated lesions. There was no significant difference between groups in mean ± SD withdrawal time (9.01 ± 2.48 seconds for the ECV group vs 8.96 ± 2.24 seconds for controls; P = .69) or proportion of subjects undergoing unnecessary polypectomies (relative risk, 0.89; 95% CI, 0.69-1.14; P = .38). CONCLUSIONS: The combination of CADe and ECV during colonoscopy increases adenoma detection rate and adenomas detected per colonoscopy without increasing withdrawal time compared with CADe alone. CLINICALTRIALS: gov, Number: NCT04676308.


Assuntos
Adenoma , Neoplasias Colorretais , Masculino , Humanos , Feminino , Colonoscopia , Adenoma/diagnóstico por imagem , Adenoma/patologia , Neoplasias Colorretais/diagnóstico , Neoplasias Colorretais/patologia , Mucosa , Computadores
17.
Gastrointest Endosc ; 98(2): 191-198, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-36990125

RESUMO

BACKGROUND AND AIMS: The role of the newer EUS fine-needle biopsy needles in lymphadenopathies (LAs) is still under evaluation. We aimed to evaluate the diagnostic accuracy and adverse event rate of EUS-guided fine-needle biopsy sampling (EUS-FNB) in diagnosing LAs. METHODS: From June 2015 to June 2022, all patients referred to 4 institutions for EUS-FNB of mediastinal and abdominal LAs were enrolled. Twenty-two-gauge Franseen tip or 25-gauge fork-tip needles were used. The criterion standard for positive results was surgery or imaging and clinical evolution over a follow-up of at least 1 year. RESULTS: One hundred consecutive patients were enrolled, consisting of those with a new diagnosis of LA (40%), presence of LA with a previous history of neoplasia (51%), or suspected lymphoproliferative disease (9%). EUS-FNB was technically feasible in all LA patients with 2 to 3 passes (mean, 2.62 ± .93). The overall sensitivity, positive predictive value, specificity, negative predictive value, and accuracy for EUS-FNB were 96.20%, 100%, 100%, 87.50%, and 97.00%, respectively. Histologic analysis was feasible in 89% of cases. Cytologic evaluation was performed in 67% of specimens. A statistical difference between the accuracy of the 22-gauge or 25-gauge needle (P = .63) was not found. A subanalysis on lymphoproliferative disease revealed a sensitivity and accuracy of 89.29% and 90.0%, respectively. No adverse events were recorded. CONCLUSIONS: EUS-FNB with new end-cutting needles is a valuable and safe method to diagnose LAs. The high quality of histologic cores and the good amount of tissue allowed a complete immunohistochemical analysis of metastatic LAs and precise subtyping of the lymphomas. (Clinical trial registration number: NCT02855151.).


Assuntos
Linfadenopatia , Linfoma , Neoplasias , Neoplasias Pancreáticas , Humanos , Estudos Prospectivos , Aspiração por Agulha Fina Guiada por Ultrassom Endoscópico/efeitos adversos , Aspiração por Agulha Fina Guiada por Ultrassom Endoscópico/métodos , Linfadenopatia/diagnóstico , Linfoma/diagnóstico , Linfoma/patologia , Neoplasias Pancreáticas/patologia
18.
Dig Liver Dis ; 55(5): 644-648, 2023 05.
Artigo em Inglês | MEDLINE | ID: mdl-36890050

RESUMO

BACKGROUND AND AIM: Endoscopic ultrasound-guided gastroenterostomy (EUS-GE) for the treatment of gastric outlet obstruction (GOO) has been actually performed only with one type of electrocautery lumen-apposing metal stents (EC-LAMS). We aimed to evaluate the safety, technical and clinical effectiveness of EUS-GE using a newly available EC-LAMS in patients with malignant and benign GOO. MATERIALS AND METHODS: Consecutive patients who underwent EUS-GE for GOO using the new EC-LAMS at five endoscopic referral centers were retrospectively evaluated. Clinical efficacy was determined utilizing the Gastric Outlet Obstruction Scoring System (GOOSS). RESULTS: Twenty-five patients (64% male, mean age 68.7 ± 9.3 years) met the inclusion criteria; 21 (84%) had malignant etiology. Technically, EUS-GE was successful in all patients, with a mean procedural time of 35 ± 5 min. Clinical success was 68% at 7 days and 100% at 30 days. The mean time to resume oral diet was 11.4 ± 5.8 h, with an improvement of at least one point of GOOSS score observed in all patients. The median hospital stay was 4 days. No procedure-related adverse events occurred. After a mean follow-up of 7.6 months (95% CI 4.6-9.2), no stent dysfunctions were observed. CONCLUSION: This study suggests EUS-GE can be performed safely and successfully using the new EC-LAMS. Future large multicenter prospective studies are needed to confirm our preliminary data.


Assuntos
Obstrução da Saída Gástrica , Ultrassonografia de Intervenção , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Eletrocoagulação/efeitos adversos , Endossonografia , Obstrução da Saída Gástrica/etiologia , Obstrução da Saída Gástrica/cirurgia , Gastroenterostomia/efeitos adversos , Estudos Retrospectivos , Stents/efeitos adversos
19.
Cancers (Basel) ; 15(2)2023 Jan 12.
Artigo em Inglês | MEDLINE | ID: mdl-36672438

RESUMO

Malignant biliary obstruction (MBO) is a challenging medical problem that often negatively impacts the patient's quality of life (QoL), postoperative complications, and survival rates. Endoscopic approaches to biliary drainage are generally performed by ERCP or, in selected cases, with a percutaneous transhepatic biliary drainage (PTBD). Recent advances in therapeutic endoscopic ultrasound (EUS) allow drainage where previous methods have failed. EUS has evolved from a purely diagnostic technique to one that allows a therapeutic approach in the event of ERCP failure in distal MBO. Moreover, the introduction of dedicated accessories and prostheses for EUS-guided transmural biliary drainage (EUS-BD) made these procedures more successful with regard to technical success, clinical outcomes and reduction of adverse events (AEs). Finally, lumen-apposing metal stents (LAMS) have improved the therapeutic role of the EUS. Subsequently, the electrocautery enhanced tip of the LAMS (EC-LAMS) allows a direct access of the delivery system to the target lumen, thereby simplifying and reducing the EUS-BD procedure time. EUS-BD using LAMS and EC-LAMS has proven effective and safe with a low rate of AEs. This review aims to evaluate biliary drainage techniques in malignant obstruction, focusing on the role of EUS biliary drainage by LAMS.

20.
Diagnostics (Basel) ; 13(2)2023 Jan 09.
Artigo em Inglês | MEDLINE | ID: mdl-36673049

RESUMO

Pancreatic neuroendocrine tumor (PNET) behavior assessment is a daily challenge for physicians. Modern PNET management varies from a watch-and-wait strategy to surgery depending on tumor aggressiveness. Therefore, the aggressiveness definition plays a pivotal role in the PNET work-up. The aggressiveness of PNETs is mainly based on the dimensions and histological grading, with sometimes a lack of specificity and sensibility. In the last twenty years, EUS has become a cornerstone in the diagnostic phase of PNET management for its high diagnostic yield and the possibility of obtaining a histological specimen. The number of EUS applications in the PNET work-up has been rapidly increasing with new and powerful possibilities. The application of contrast has led to an important step in PNET detection; in recent years, it has been gaining interesting applications in aggressiveness assessment. In this review, we underline the latest experiences and opportunities in the behavior assessment of PNETs using contact-enhanced EUS and contested enhanced harmonic EUS with a particular focus on the future application and possibility that these techniques could provide.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA