Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
JACC Cardiovasc Interv ; 17(17): 2054-2066, 2024 Sep 09.
Artigo em Inglês | MEDLINE | ID: mdl-39260962

RESUMO

BACKGROUND: Fluid overload (FO) subjects patients with severe aortic stenosis (AS) to increased risk for heart failure and death after valve replacement and can be objectively quantified using bioimpedance spectroscopy (BIS). OBJECTIVES: The authors hypothesized that in AS patients with concomitant FO, BIS-guided decongestion could improve prognosis and quality of life following transcatheter aortic valve replacement (TAVR). METHODS: This randomized, controlled trial enrolled 232 patients with severe AS scheduled for TAVR. FO was defined using a portable whole-body BIS device according to previously established cutoffs (≥1.0 L and/or ≥7%). Patients with FO (n = 111) were randomly assigned 1:1 to receive BIS-guided decongestion (n = 55) or decongestion by clinical judgment alone (n = 56) following TAVR. Patients without FO (n = 121) served as a control cohort. The primary endpoint was the composite of hospitalization for heart failure and/or all-cause death at 12 months. The secondary endpoint was the change from baseline to 12 months in the Kansas City Cardiomyopathy Questionnaire. RESULTS: The occurrence of the primary endpoint at 12 months was significantly lower in the BIS-guided vs the non-BIS-guided decongestion group (7/55 [12.7%, all deaths] vs 18/56 [32.1%, 9 hospitalizations for heart failure and 9 deaths]; HR: 0.36; 95% CI: 0.15-0.87; absolute risk reduction = -19.4%). Outcomes in the BIS-guided decongestion group were identical to the euvolemic control group (log-rank test, P = 0.7). BIS-guided decongestion was also associated with a higher increase in the Kansas City Cardiomyopathy Questionnaire score from baseline compared to non-BIS-guided decongestion (P = 0.001). CONCLUSIONS: In patients with severe AS and concomitant FO, quantitatively guided decongestive treatment and associated intensified management post-TAVR was associated with improved outcomes and quality of life compared to decongestion by clinical judgment alone. (Management of Fluid Overload in Patients Scheduled for Transcatheter Aortic Valve Replacement [EASE-TAVR]; NCT04556123).


Assuntos
Estenose da Valva Aórtica , Insuficiência Cardíaca , Qualidade de Vida , Índice de Gravidade de Doença , Substituição da Valva Aórtica Transcateter , Humanos , Estenose da Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/mortalidade , Feminino , Masculino , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/mortalidade , Substituição da Valva Aórtica Transcateter/instrumentação , Resultado do Tratamento , Idoso , Idoso de 80 Anos ou mais , Fatores de Risco , Fatores de Tempo , Insuficiência Cardíaca/fisiopatologia , Insuficiência Cardíaca/mortalidade , Insuficiência Cardíaca/terapia , Insuficiência Cardíaca/diagnóstico , Espectroscopia Dielétrica , Desequilíbrio Hidroeletrolítico/fisiopatologia , Desequilíbrio Hidroeletrolítico/terapia , Desequilíbrio Hidroeletrolítico/diagnóstico , Desequilíbrio Hidroeletrolítico/mortalidade , Desequilíbrio Hidroeletrolítico/etiologia , Valva Aórtica/cirurgia , Valva Aórtica/fisiopatologia , Valva Aórtica/diagnóstico por imagem , Valor Preditivo dos Testes , Recuperação de Função Fisiológica , Estudos Prospectivos
3.
Eur J Heart Fail ; 25(10): 1808-1818, 2023 10.
Artigo em Inglês | MEDLINE | ID: mdl-37462329

RESUMO

AIMS: Cardiac decompensation in aortic stenosis (AS) involves extra-valvular cardiac damage and progressive fluid overload (FO). FO can be objectively quantified using bioimpedance spectroscopy. We aimed to assess the prognostic value of FO beyond established damage markers to guide risk stratification. METHODS AND RESULTS: Consecutive patients with severe AS scheduled for transcatheter aortic valve implantation (TAVI) underwent prospective risk assessment with bioimpedance spectroscopy (BIS) and echocardiography. FO by BIS was defined as ≥1.0 L (0.0 L = euvolaemia). The extent of cardiac damage was assessed by echocardiography according to an established staging classification. Right-sided cardiac damage (rCD) was defined as pulmonary vasculature/tricuspid/right ventricular damage. Hospitalization for heart failure (HHF) and/or death served as primary endpoint. In total, 880 patients (81 ± 7 years, 47% female) undergoing TAVI were included and 360 (41%) had FO. Clinical examination in patients with FO was unremarkable for congestion signs in >50%. A quarter had FO but no rCD (FO+/rCD-). FO+/rCD+ had the highest damage markers, including N-terminal pro-B-type natriuretic peptide (NT-proBNP) levels. After 2.4 ± 1.0 years of follow-up, 236 patients (27%) had reached the primary endpoint (29 HHF, 194 deaths, 13 both). Quantitatively, every 1.0 L increase in bioimpedance was associated with a 13% increase in event hazard (adjusted hazard ratio 1.13, 95% confidence interval 1.06-1.22, p < 0.001). FO provided incremental prognostic value to traditional risk markers (NT-proBNP, EuroSCORE II, damage on echocardiography). Stratification according to FO and rCD yielded worse outcomes for FO+/rCD+ and FO+/rCD-, but not FO-/rCD+, compared to FO-/rCD-. CONCLUSION: Quantitative FO in patients with severe AS improves risk prediction of worse post-interventional outcomes compared to traditional risk assessment.


Assuntos
Estenose da Valva Aórtica , Insuficiência Cardíaca , Substituição da Valva Aórtica Transcateter , Humanos , Feminino , Masculino , Insuficiência Cardíaca/etiologia , Estudos Prospectivos , Prognóstico , Substituição da Valva Aórtica Transcateter/métodos , Estenose da Valva Aórtica/complicações , Estenose da Valva Aórtica/diagnóstico , Estenose da Valva Aórtica/cirurgia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA