Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
Int J Infect Dis ; 136: 77-80, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37660726

RESUMO

We report the isolation of a rare Gram-positive coccobacillary bacterium from synovial fluids of a patient with periprosthetic joint infection on three occasions over an 8-month period. As routine microbiological methods were not able to identify the isolate definitely, sequence analyses of the bacterial 16S ribosomal RNA gene and whole genome were performed. Analysis of the bacterial 16S ribosomal RNA gene showed the highest similarity (98.1%) with that of Falsarthrobacter (previously known as Arthrobacter) nasiphocae, which was first isolated from the nasal cavities of common seals (Phoca vitulina). The genome size of the strain (designated as UM1) is 2.4 Mb. With a high G+C content (70.4 mol%), strain UM1 is phylogenetically most closely related to F. nasiphocae based on whole genome analysis. Strain UM1 was susceptible to vancomycin, linezolid, trimethoprim-sulfamethoxazole, doxycycline, and intermediate to penicillin and ciprofloxacin. Ceftriaxone resistance was noted. The patient who was also on hemodialysis for his end stage kidney disease died approximately 3 weeks following implant removal and fusion with an external fixator. This study describes the first isolation of F. nasiphocae from human clinical samples. The use of emerging technologies has supported more definitive etiological diagnosis associated with rarely encountered organisms in periprosthetic joint infection.


Assuntos
Artrite Infecciosa , Micrococcaceae , Infecções Relacionadas à Prótese , Humanos , Infecções Relacionadas à Prótese/diagnóstico , Infecções Relacionadas à Prótese/microbiologia , Bactérias , Artrite Infecciosa/diagnóstico , Artrite Infecciosa/tratamento farmacológico , Bactérias Gram-Positivas
2.
Front Med (Lausanne) ; 9: 904721, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36106324

RESUMO

Objective: Synovitis with increased infiltration of immune cells is observed in osteoarthritis (OA). Given the inflammatory condition of synovitis, we explored the protein profile of OA synovium (OAS) and its effect on circulating monocytes activation, migration, and functional commitments. Methods: Knee-synovium was acquired from end-stage OA (N = 8) and trauma patients (Trauma baseline control: TBC; N = 8) for characterization using H&E histology, IHC (iNOS), LCMS-QTOF, and MALDI-imaging. Response of peripheral blood monocytes to OAS conditioned-media (OACM) was observed using transwell (n = 6). The migrated cells were captured in SEM, quantified using phase-contrast microphotographs, and their activation receptors (CCR2, CXCR2, CX3CR1, and CD11b), pro-inflammatory genes, and phagocytic potential were studied using flow cytometry, gene expression array/qPCR, and latex beads (LB) phagocytosis assay, respectively. Results: The Venn diagram displayed 119 typical proteins in OAS, while 55 proteins in TBCS. The STRING protein network analysis indicated distinctive links between proteins and gene ontology (GO) and revealed proteins associated with leukocyte-mediated immunity in OAS as compared to TBC. The MALDI-imaging showed typical localized proteins at 2234.97, 2522.61, 2627.21, 3329.50, and 3539.69 m/z and IHC confirmed pro-inflammatory iNOS expression in OA synovium. CD14++CD16- classical monocytes significantly migrated in OACM and expressed CCR2, CXCR2, and CD11b receptors, TNFRSF11A, MAPK1, S100A8, HSPB1, ITGAL, NFATC1, IL13RA1, CD93, IL-1ß, TNF-α, and MYD88 genes and increased LB uptake as compared to SFM. Conclusion: Our findings suggest that the differential protein profile of OA synovium and the classical monocytes migrated, activated, and functionally committed in response to these mediators could be of therapeutic advantage.

3.
Jt Dis Relat Surg ; 33(1): 225-229, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35361099

RESUMO

Knee arthroplasties are successful procedures that allow patients to return to their pre-arthritic functional levels. However, the success rates can be blemished by prosthetic joint infections, which are devastating complications that commonly render patients worse off than before the index surgery. Inoculation of the pathogens is frequently from the index surgery, or through the bloodstream. Herein, we report a case of a prosthetic joint infection by which the pathogens were most likely inoculated from direct contact, through a traumatic open knee wound occurring from a road traffic accident. Management of the infection, involving an incision & drainage with modular parts exchange, as well as the challenges with the soft tissue envelope is highlighted. At one year of follow-up, the infection seemed to be curtailed. Currently, the patient is very satisfied with the condition of his knee, which has a range of motion of 0 to 135 and his pre-morbid function has been regained. This case denotes the importance of early identification, soft tissue management, as well as a multidisciplinary approach in managing such conditions.


Assuntos
Artroplastia do Joelho , Articulação do Joelho , Artroplastia do Joelho/efeitos adversos , Humanos , Articulação do Joelho/cirurgia , Amplitude de Movimento Articular
4.
J Orthop Surg (Hong Kong) ; 29(1): 2309499021992618, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33632009

RESUMO

BACKGROUND: There is a common perception among surgeons that Asian tibiae are significantly more varus compared to non-Asians, contributed both by an acute medial tibial proximal angle (MPTA) and diaphyseal bowing. Insight into the normative morphology of the tibia allows generation of knowledge towards disease processes and subsequently planning for corrective surgeries. METHODS: Computed tomography (CT) scans of 100 normal adult knees, aged 18 years and above, were analysed using a 3-dimensional (3D) analysis software. All tibiae were first aligned to a standard frame of reference and then rotationally aligned to the tibial centroid axis (TCAx) and the transmalleolar axis (tmAx). MPTA was measured from best-fit planes on the surface of the proximal tibia for each rotational alignment. Diaphyseal bowing was assessed by dividing the shaft to three equal portions and establishing the angle between the proximal and distal segments. RESULTS: The mean MPTA was 87.0° ± 2.2° (mean ± SD) when rotationally aligned to TCAx and 91.6° ± 2.7° when aligned to tmAx. The mean diaphyseal bowing was 0.1° ± 1.9° varus when rotationally aligned to TCAx and 0.3° ± 1.6° valgus when aligned to tmAx. The mean difference when the MPTA was measured with two different rotational alignments (TCAx and tmAx) was 4.6° ± 2.3°. No statistically significant differences were observed between males and females. Post hoc tests revealed statistically significant difference in MPTA between different ethnic sub-groups. CONCLUSION: The morphology of the proximal tibiae in the disease-free Asian knee is inherently varus but not more so than other reported populations. The varus profile is contributed by the MPTA, with negligible diaphyseal bowing. These implications are relevant to surgical planning and prosthesis design.


Assuntos
Povo Asiático , Doenças do Desenvolvimento Ósseo/diagnóstico por imagem , Doenças do Desenvolvimento Ósseo/etnologia , Osteocondrose/congênito , Tíbia/diagnóstico por imagem , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Articulação do Joelho/diagnóstico por imagem , Malásia , Masculino , Pessoa de Meia-Idade , Osteocondrose/diagnóstico por imagem , Osteocondrose/etnologia , Estudos Retrospectivos , Tomografia Computadorizada por Raios X , Adulto Jovem
5.
Jt Dis Relat Surg ; 32(1): 239-244, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33463444

RESUMO

Injuries to the pelvic vasculature during total hip arthroplasties are rare but have serious consequence. They demand urgent and early identification so that appropriate treatment can be instituted. If the bleeding is severe, cardiovascular compromise occurs intraoperatively and this will alert the surgeon of this possibility during acetabular screw placement. Alternatively, a delay in diagnosis can occur because the bleeding and the injured vessel are in the pelvic cavity and not visualized during the surgery. In this article, we report two cases from our center occurring within a six-month interval that sustained a vascular injury during acetabular drilling for screw placement for cementless cup fixation. Each case had a different vessel injury and different lessons can be learned from these rare injuries. The first case had an injury of the inferior gluteal artery following a breach of the sciatic notch. The vessel was treated with percutaneous embolization. The second case demonstrated a venous injury, following a medial protrusio technique for congenital hip dysplasia and a short anterosuperior screw, transecting the external iliac vein. This was subsequently repaired using an endovascular technique. We conclude the reasons for these vessel injuries after analyzing advanced imaging, discuss measures to avoid vessel injury and detail the minimally invasive method for their treatment.


Assuntos
Acetábulo , Artroplastia de Quadril , Embolização Terapêutica/métodos , Procedimentos Endovasculares/métodos , Complicações Intraoperatórias , Pelve , Lesões do Sistema Vascular , Acetábulo/diagnóstico por imagem , Acetábulo/cirurgia , Artroplastia de Quadril/efeitos adversos , Artroplastia de Quadril/instrumentação , Artroplastia de Quadril/métodos , Parafusos Ósseos , Feminino , Humanos , Complicações Intraoperatórias/diagnóstico , Complicações Intraoperatórias/etiologia , Complicações Intraoperatórias/prevenção & controle , Complicações Intraoperatórias/terapia , Masculino , Pessoa de Meia-Idade , Pelve/irrigação sanguínea , Pelve/cirurgia , Cuidados Pré-Operatórios/métodos , Risco Ajustado/métodos , Lesões do Sistema Vascular/diagnóstico , Lesões do Sistema Vascular/etiologia , Lesões do Sistema Vascular/prevenção & controle , Lesões do Sistema Vascular/terapia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA