Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
Sci Rep ; 14(1): 16313, 2024 07 15.
Artigo em Inglês | MEDLINE | ID: mdl-39009630

RESUMO

In 67Ga-citrate scintigraphy (Ga-S), visual assessment is used by evaluating renal-uptake comparison with liver and spine and is simple and objective. We adopted the standardized uptake value (SUV) for 67Ga-citrate and proposed two quantitative indices, active nephritis volume (ANV) and total nephritis uptake (TNU). This study clarified the utility of new Ga-S-based quantitative indices in nephritis management. Before SUV measurement, the Becquerel calibration factor of 67Ga-citrate was obtained using a phantom experiment. Seventy patients who underwent SPECT/CT imaging were studied. SUV, ANV, and TNU were calculated using a quantitative analysis software for bone SPECT. SUVmean, ANV, and TNU were analyzed using the (1) threshold method (set 40%) and constant-value method for (2) vertebral SUVmax, and (3) vertebral SUVmean. ROC analysis was used to evaluate SUV, ANV, and TNU diagnostic abilities to distinguish nephritis presence and absence as well as interstitial nephritis (IN) and non-IN. The area under the curve (AUC) for nephritis presence or absence had a good value (0.80) for SUVmean (1), ANV (3), and TNU (3). The AUC for differentiation between IN and non-IN groups had a good value (0.80) for SUVmean (1). Thus, the new Ga-S-based quantitative indices were useful to evaluate nephritis and distinguish IN and non-IN.


Assuntos
Radioisótopos de Gálio , Gálio , Humanos , Masculino , Feminino , Pessoa de Meia-Idade , Idoso , Adulto , Nefrite/diagnóstico por imagem , Citratos , Curva ROC , Idoso de 80 Anos ou mais , Compostos Radiofarmacêuticos , Tomografia Computadorizada com Tomografia Computadorizada de Emissão de Fóton Único/métodos
2.
Jpn J Radiol ; 42(5): 519-535, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38345724

RESUMO

PURPOSE: Somatostatin receptor scintigraphy (SRS) using 111In-DTPA-DPhe1-octreotide (pentetreotide) has become an integral part of neuroendocrine neoplasm management. The lack of precise quantification is a disadvantage of SRS. This study aimed to adapt the standardized uptake value (SUV) to SRS, establish the SUV range for physiological uptake in the liver, kidney, and spleen, and elucidate the utility of combined visual and quantitative SRS assessment for staging and restaging of neuroendocrine tumors (NETs). MATERIALS AND METHODS: This study included 21 patients with NETs who underwent 111In-pentetreotide SRS. The SUV of physiological and pathological uptake was calculated using bone single-photon emission computed tomography (SPECT) quantitative analysis software (GI-BONE). For visual analysis, the primary and metastatic lesions were scored visually on planar and SPECT images using a five-point scale. We assessed the relationships between the SUVs of the liver, kidney, and spleen in the dual phase, and among quantitative indices, visual score, and pathological lesions classification. RESULTS: Sixty-three NEN lesions were evaluated. The mean ± standard deviation maximum SUVs (SUVmax) were liver: 4 h, 2.6 ± 1.0; 24 h, 2.2 ± 1.0; kidney: 4 h, 8.9 ± 1.8; 24 h, 7.0 ± 2.0; and spleen; 4 h, 11.3 ± 4.5; 24 h, 11.5 ± 7.6. Higher SUVmax was significantly associated with higher visual scores on dual-phase SPECT (4 h, p < 0.001; 24 h, p < 0.001) (4 h: scores 3 and 4, p < 0.05; scores 3 and 5: p < 0.01; scores 4 and 5: p < 0.01; 24 h: scores 3 and 4, p = 0.0748; scores 3 and 5: p < 0.01; scores 4 and 5: p < 0.01). CONCLUSION: We adapted the SUV to SRS and established the range of SUV for physiological uptake in the liver, kidney, and spleen. Combined visual and quantitative assessment is useful for imaging individual lesions in greater detail, and may serve as a new tumor marker of SRS for staging and restaging of NETs.


Assuntos
Estadiamento de Neoplasias , Tumores Neuroendócrinos , Compostos Radiofarmacêuticos , Receptores de Somatostatina , Somatostatina/análogos & derivados , Humanos , Tumores Neuroendócrinos/diagnóstico por imagem , Tumores Neuroendócrinos/patologia , Masculino , Feminino , Pessoa de Meia-Idade , Idoso , Adulto , Receptores de Somatostatina/metabolismo , Tomografia Computadorizada de Emissão de Fóton Único/métodos , Estudos Retrospectivos , Idoso de 80 Anos ou mais
3.
Jpn J Radiol ; 41(4): 428-436, 2023 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-36449252

RESUMO

PURPOSE: Amyloid light chain (AL) and transthyretin (ATTR) are the major subtypes of cardiac amyloidosis (CA). 99mTc-pyrophosphate (PYP) scintigraphy is used to differentiate ATTR from other CA subtypes. We adapted the standardized uptake value (SUV) for 99mTc-PYP and proposed two quantitative indices, amyloid deposition volume (AmyDV) and total amyloid uptake (TAU). This study aimed to evaluate the utility of these quantitative indices in differentiating ATTR from non-ATTRs. MATERIALS AND METHODS: Before the SUV measurement, the Becquerel calibration factor (BCF) of 99mTc was obtained by a phantom experiment. Thirty-two patients who had undergone hybrid SPECT/CT imaging 3 h after injection of 99mTc-PYP (370 MBq) were studied. CT attenuation correction for image reconstruction was applied in all. We calculated SUV, AmyDV, and TAU using a quantitative analysis software program for bone SPECT (GI-BONE) and analyzed AmyDV using two methods: threshold method (set 40%); and constant value method (average SUVmax of ribs). We assessed the diagnostic ability of heart-to-contralateral lung (H/CL) ratio, SUV, AmyDV, and TAU to differentiate ATTR from non-ATTR using receiver operating characteristic (ROC) analysis. RESULTS: Statistically significant differences in all quantitative indices were observed between ATTR and non-ATTR. The area under the curve of each quantitative index for discriminating between ATTR and non-ATTR were as follows: H/CL, 0.997; SUVmax, 0.953; SUVmean (M1), 0.964; SUVmean (M2), 0.969; AmyDV (M1), 0.875; AmyDV (M2), 0.974; and TAU, 0.974. The AmyDV (M2) had higher diagnostic ability than AmyDV (M1). Thus, TAU was calculated as AmyDV (M2) × SUVmean (M2). In the ROC curve, SUV, AmyDV, and TAU had almost the same diagnostic ability as H/CL in distinguishing ATTR from non-ATTRs. CONCLUSIONS: We propose two novel 3D-based quantitative parameters (AmyDV and TAU) that have almost equal ability to discriminate ATTR from non-ATTR.


Assuntos
Amiloidose , Cardiomiopatias , Humanos , Difosfatos , Pirofosfato de Tecnécio Tc 99m , Cardiomiopatias/diagnóstico por imagem , Amiloidose/diagnóstico por imagem , Cintilografia , Amiloide
4.
Ann Nucl Med ; 35(9): 1004-1014, 2021 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-34046870

RESUMO

OBJECTIVE: The recommended start time for 18F-flutemetamol amyloid positron emission tomography (PET) examination is 60-120 min after 18F-flutemetamol injection, while an acquisition time of 10-30 min is generally recommended. We aimed to elucidate the effects of different examination conditions on image quality, diagnostic ability, and quantitative value of amyloid PET using 18F-flutemetamol. METHODS: We acquired data on a Discovery PET/computed tomography 710 scanner using Hoffman brain and pillar phantoms with 20 MBq of 18F for 30 min. The images were reconstructed into 10-, 20-, and 30-min periods. The ordered subset-expectation maximization algorithm was used for image reconstruction, which uses a 2- or 4-mm Gaussian filter and a combination of iteration and subset numbers. The percentage contrast and coefficient of variation (CV; as the image noise) were used as physical evaluation indices for reconstructed images, and images with superior contrast and low image noise were selected for clinical evaluation. The imaging data of 15 symptomatic patients (n = 7 and n = 8 for positive and negative diagnoses of Alzheimer's disease, respectively) were reconstructed under the phantom study conditions. Radiographers visually evaluated and ranked the clinical images based on the overall contrast and image noise, and nuclear medicine specialists diagnosed Alzheimer's disease. We compared the standardized uptake value ratio (SUVR) obtained with different acquisition conditions. RESULTS: The basic study using the phantom revealed high convergence of contrast and image noise in five patterns of acquisition time and filter strengths. Regarding visual evaluation, the use of a 2-mm Gaussian filter caused difficulties in diagnosis because the brain parenchymal accumulation was mottled with high image noise. Differences in image quality and diagnostic ability due to different examination times were not significant. Differences in the SUVR were not significant in patients with a negative Alzheimer's disease diagnosis; in patients with a positive diagnosis, the SUVR showed significant fluctuation depending on the acquisition conditions. CONCLUSION: The differences in image quality and diagnostic performance due to the differences in 10-min acquisition time were not significant; however, of note, SUVR showed significant fluctuation depending on the acquisition conditions in patients diagnosed with Alzheimer's disease.


Assuntos
Compostos de Anilina , Benzotiazóis , Tomografia por Emissão de Pósitrons , Amiloide , Humanos
5.
Ann Nucl Med ; 35(4): 504-513, 2021 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-33630226

RESUMO

OBJECTIVE: Dopamine transporter single-photon emission computed tomography (DAT SPECT) has been widely used to diagnose Parkinson syndrome. Using the standardized uptake value (SUV) of DAT SPECT, we propose "functional dopamine transporter volume (f-DTV)" as a new quantitative index to evaluate the three-dimensional volume of functional dopamine transporters and assess its diagnostic ability in differentiating dopaminergic neurodegenerative diseases (dNDD) from non-dNDD. METHODS: Seventy-nine patients were enrolled (42 dNDD, 37 non-dNDD; 38 men; age 24-88 years). We analyzed seven quantitative indices. The specific binding ratio (SBR) was calculated using a program specialized for DAT SPECT (SBR_Bolt). The SUVmax, SUVpeak, and SUVmean were calculated using a quantification program for bone SPECT. SBR_SUV was calculated by dividing striatal SUVmean by the average of background SUVmean. The cutoff value of the active dopamine transporter level was examined using three methods (threshold of 40% of SUVmax, SUV 2, and SUV 3) to calculate the active dopamine transporter volume (ADV). The f-DTV was calculated by multiplying ADV and SUVmean. We assessed the correlations between SBR_Bolt and SBR_SUV, and compared the mean value of each index between the dNDD and non-dNDD groups. The abilities of SBR_Bolt, SBR_SUV, SUVmax, SUVpeak, SUVmean, ADV, and f-DTV in differentiating dNDD from non-dNDD were determined by the area under the receiver operating curve (AUC) generated by the receiver operating characteristics analysis. RESULTS: The SBR_Bolt and SBR_SUV highly correlated with each other (r = 0.71). The cutoff value of the active dopamine transporter level was determined as SUV 3. All seven quantitative indices showed lower values in the dNDD group than in the non-dNDD group, and the difference between the two groups was statistically significant (p < 0.05). Sensitivity, specificity, and AUC of f-DTV were slightly lower than those of SBR_Bolt (71%, 79%, and 0.81, respectively, for f-DTV, and 81%, 84%, 0.88, respectively, for SBR_Bolt). The difference in AUC between f-DTV and SBR_Bolt was not statistically significant. CONCLUSIONS: This study demonstrates the utility of f-DTV as a novel quantitative index for evaluating the three-dimensional volume of functional dopamine transporters, and that f-DTV has almost the same diagnostic ability to differentiate dNDD from non-dNDD using DAT SPECT.


Assuntos
Proteínas da Membrana Plasmática de Transporte de Dopamina/metabolismo , Radioisótopos do Iodo/química , Nortropanos/química , Doença de Parkinson/diagnóstico por imagem , Tomografia Computadorizada de Emissão de Fóton Único/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Transporte Biológico , Diagnóstico Diferencial , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Doença de Parkinson/classificação , Imagens de Fantasmas , Curva ROC , Estudos Retrospectivos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA