Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
J Clin Med ; 12(6)2023 Mar 09.
Artigo em Inglês | MEDLINE | ID: mdl-36983139

RESUMO

Transcatheter aortic valve implantation (TAVR) is the first therapeutic option for elderly patients with severe symptomatic aortic stenosis, and indications are steadily expanding to younger patients and subjects with lower surgical risk and longer life expectancy. Commissural alignment between native and transcatheter valves facilitates coronary access after TAVR and is thus considered a procedural goal, allowing long-term management of coronary artery disease. Moreover, commissural alignment may potentially have a positive impact on transvalvular hemodynamic and valve durability. This review focus on technical hints to achieve commissural alignment and current evidence for different transcatheter aortic valves.

2.
Catheter Cardiovasc Interv ; 98(2): E282-E290, 2021 08 01.
Artigo em Inglês | MEDLINE | ID: mdl-33241627

RESUMO

AIMS: Early discharge after transcatheter aortic valve implantation (TAVI) may potentially impact post-procedural safety of the patient. The study aim was to compare safety of TAVI in patients planned for fast track hospital stay with patients planned for standard hospital stay. METHODS AND RESULTS: All-comers patients undergoing transfemoral TAVI between 2011 and 2017 were allocated to two matched groups depending whether the procedure was performed before or after transition from standard to fast track course. Data on vital status and hospitalizations were obtained through national registries. Three hundred and nineteen matched pairs were eligible for analysis. The median length of post-procedural stay was 3 days (IQR: 2-4) for patients in the fast track group compared to 6 days (IQR: 4-8) in the standard approach group (p < .0001). There was no difference in all-cause mortality between groups at 30-day (1.3% vs. 1.9%, p = .52) or 90-day follow-up (2.9% vs. 4.1%, p = .42). There was no difference in the risk of new permanent pacemaker implantation (PPI) in pacemaker naïve patients between groups at 30-day (15.8% vs. 21.2%, p = .16) or 90-day follow-up (15.8% vs. 21.9%, p = .12). There was no difference in the rate of rehospitalization between groups between discharge and 90-day follow-up (2.09 per patient-year vs. 2.09 per patient-year, p = .99). CONCLUSIONS: Early discharge in an all-comers population undergoing transfemoral TAVI is safe with regards to all-cause mortality, need for PPI, and rehospitalization.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Hospitais , Humanos , Alta do Paciente , Complicações Pós-Operatórias , Fatores de Risco , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA