Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
Cureus ; 14(12): e32229, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-36620783

RESUMO

Myxedema coma and its treatment are potent physical stressors that likely predispose patients to develop Takotsubo cardiomyopathy (TCM). We postulate a multifactorial pathophysiology for TCM that includes a mechanism involving catecholamine-induced potentiation of cardiac adrenoreceptors during thyroid hormone replacement in the setting of severe hypothyroidism. Furthermore, TCM can be difficult to anticipate when presenting as a complication of another diagnosis. In this case report, we aim to improve awareness of TCM as a consequence of extreme hypothyroid states.

2.
J Med Case Rep ; 15(1): 548, 2021 Nov 04.
Artigo em Inglês | MEDLINE | ID: mdl-34732250

RESUMO

BACKGROUND: Over-the-counter medication overdose is a difficult diagnostic challenge for many physicians as common drug screening assays cannot detect these substances. We present a case of acute psychosis, serotonin syndrome, and anticholinergic overdose-like properties in the setting of Coricidin HBP Cough & Cold tablets, known by their street name Triple-C. This is the first case report we are aware of involving a patient presenting with these symptoms and requiring critical-care-level support. CASE PRESENTATION: A 31-year-old African American female with a past medical history of anxiety, childhood asthma, previous methamphetamine abuse, and coronavirus disease 2019 infection in August 2020 was brought to the emergency department by the local police department with altered mental status. Initial blood work, including extended drug screens, were unremarkable for a definitive diagnosis. This patient required critical-care-level support and high sedation because of her symptoms. Collateral history revealed the patient regularly consumed Triple-C daily for the 6 weeks prior to admission. A trial off sedation was attempted after 24 hours with no complications. The patient admitted to regular Triple-C consumption and auditory hallucinations since adolescence. She was discharged safely after 48 hours back into the community. She was lost to follow-up with psychiatry and internal medicine; however, she was evaluated in the emergency room 1 month later with a similar psychiatric presentation. CONCLUSION: Overdose of Triple-C should be kept in the differential diagnosis of patients presenting with a triad of psychosis, serotonin syndrome, and anticholinergic overdose, in the setting of unknown substance ingestion.


Assuntos
COVID-19 , Overdose de Drogas , Transtornos Psicóticos , Síndrome da Serotonina , Adolescente , Adulto , Criança , Overdose de Drogas/complicações , Overdose de Drogas/diagnóstico , Feminino , Humanos , Transtornos Psicóticos/diagnóstico , Transtornos Psicóticos/tratamento farmacológico , SARS-CoV-2 , Síndrome da Serotonina/induzido quimicamente , Síndrome da Serotonina/diagnóstico
3.
BMJ Evid Based Med ; 2021 Mar 30.
Artigo em Inglês | MEDLINE | ID: mdl-33785511

RESUMO

OBJECTIVES: Systematic reviews are often considered among the highest quality of evidence. Completely reported systematic reviews, however, are required so readers can assess for generalisability of the research to practice and risk of bias. The objective of this study was to assess the completeness of reporting for systematic reviews assessing the diagnostic accuracy of point-of-care ultrasound (POCUS) using the Preferred Reporting Items for Systematic Reviews and Meta-analyses for Diagnostic Test Accuracy (PRISMA-DTA) checklist that was published in 2018. DESIGN AND SETTING: In this meta-research study, MEDLINE, EMBASE and Cochrane Library databases were searched, with no date restriction, on March 1st, 2020 for systematic reviews assessing the diagnostic accuracy of POCUS. Adherence to PRISMA-DTA for the main text and abstract was scored independently and in duplicate using a modified checklist. Prespecified subgroup analyses were performed. MAIN OUTCOME MEASURES: The primary outcome was the mean PRISMA-DTA checklist adherence for the full-text and abstract. RESULTS: A total of 71 studies published from 2008 to 2020 met the inclusion criteria. The overall adherence for the full-text was moderate: 19.8 out of 26.0 items (76%) and for the abstract was 7.0 out of 11.0 items (64%). Although many items in the PRISMA-DTA checklist were frequently reported, several were r infrequently reported (<33% of studies), including item 5 (protocol registration), item D2 (minimally acceptable test accuracy) and item 14 (variability in target condition, index test and reference standards). Subgroup analyses showed a higher PRISMA-DTA mean adherence (SD) for high impact journals (20.9 (2.52) vs 18.9 (1.95); p<0.001), studies including supplemental materials (20.6 (2.48) vs 18.9 (2.28); p=0.004), studies citing adherence to PRISMA reporting guidelines (20.4 (1.95) vs 19.0 (3.00); p=0.038) and studies published in journals endorsing PRISMA guidelines (20.2 (2.47) vs 18.6 (2.37); p=0.025). There was variable adherence based on journal of publication (p=0.006), but not for study population (adult vs paediatric vs mixed) (p=0.62), year of publication (p=0.94), body region (p=0.78) or country (p=0.40). There was no variability in abstract adherence based on whether the abstract was structured with subheadings or not (p=0.25). A Spearman's correlation found moderate correlation between higher word counts and abstractand full-text adherence (R=0.45, p<0.001 and R=0.38, p=0.001), respectively. CONCLUSIONS: Overall, the reporting of POCUS diagnostic accuracy systematic reviews and meta-analyses was moderate. We identified deficits in several key areas including the preregistration of systematic reviews in an online repository, handling of multiple definitions of target conditions, index tests and reference standards and specifying minimally acceptable test accuracy. Prospective registration of reviews and detailed reporting as per PRISMA-DTA during the research process could improve reporting completeness. At an editorial level, word count and supplemental material limitations may impede reporting completeness, whereas endorsement of reporting guidelines on journal websites could improve reporting.

4.
BMJ Evid Based Med ; 26(3): 110-111, 2021 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-33177166

RESUMO

OBJECTIVES: Point-of-care ultrasound (POCUS) diagnostic accuracy research has significant variation in blinding practices. This study characterises the blinding practices during acute POCUS research to determine whether research methodology adequately reflects POCUS use in routine clinical practice. DESIGN, SETTINGS AND PARTICIPANTS: A search for POCUS diagnostic accuracy studies published in Emergency Medicine, Anaesthesia and Critical Care journals from January 2016 to January 2020 was performed. Studies were included if they were primary diagnostic accuracy studies. The study year, journal impact factor, population, hospital area, body region, study design, blinding of the POCUS interpreter to clinical information, whether the person performing the POCUS scan was the same person interpreting the scan, and whether the study reported incremental diagnostic yield were extracted in duplicate by two authors. Descriptive statistics were provided and prespecified subgroup analysis was performed. MAIN OUTCOME MEASURES: The primary outcome was the number of studies that blinded the POCUS interpreter to at least some part of the clinical information. Secondary outcomes included whether the person performing the POCUS scan was the same person interpreting it and whether the study reported incremental diagnostic yield. RESULTS: 520 abstracts were screened with 97 studies included. The POCUS interpreter was blinded to clinical information in 37 studies (38.1%), not blinded in 34 studies (35.1%) and not reported in 26 studies (26.8%). The POCUS interpreter was the same person obtaining the images in 72 studies (74.2%), different in 14 studies (14.4%) and not reported in 11 studies (11.3%). Only four studies (4.1%) reported incremental diagnostic yield for POCUS. Inter-rater reliability was moderate (k=0.64). Subgroup analysis based on impact factor, body region, hospital area, patient population and study design did not show significant differences after completing pairwise comparisons. CONCLUSIONS: Although blinding the POCUS interpreter to clinical information may be done in a perceived attempt to limit bias, this may result in accuracy estimates that do not reflect routine clinical practice. Similarly, having a different clinician perform and interpret the POCUS scan significantly limits generalisability to practice as it does not truly reflect 'point-of-care' ultrasound at all. Reporting incremental diagnostic yield from implementing POCUS into a diagnostic pathway better reflects the value of POCUS; however, this methodology was infrequently used. TRIAL REGISTRATION NUMBER: The study protocol was registered on Open Science Framework (https://osf.io/h5fe7/).


Assuntos
Testes Diagnósticos de Rotina , Sistemas Automatizados de Assistência Junto ao Leito , Humanos , Reprodutibilidade dos Testes , Ultrassonografia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA