1.
Osong Public Health Res Perspect ; 15(1): 45-55, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38481049

RESUMO

BACKGROUND: We examined factors contributing to the transmission of an acute respiratory virus within multi-use facilities, focusing on an outbreak of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) in a movie theater in the Republic of Korea. METHODS: This retrospective cohort study involved a descriptive analysis of 48 confirmed cases. Logistic regression was applied to a cohort of 80 theater attendees to identify risk factors for infection. The infection source and transmission route were determined through gene sequencing data analysis. RESULTS: Of the 48 confirmed cases, 35 were theater attendees (72.9%), 10 were family members of attendees (20.8%), 2 were friends (4.2%), and 1 was an employee (2.1%). Among the 80 individuals who attended the 3rd to 5th screenings of the day, 35 became infected, representing a 43.8% attack rate. Specifically, 28 of the 33 third-screening attendees developed confirmed SARSCoV-2, constituting an 84.8% attack rate. Furthermore, 11 of the 12 cases epidemiologically linked to the theater outbreak were clustered monophyletically within the AY.69 lineage. At the time of the screening, 35 individuals (72.9%) had received 2 vaccine doses. However, vaccination status did not significantly influence infection risk. Multivariate analysis revealed that close contacts had a 15.9-fold higher risk of infection (95% confidence interval, 4.37-78.39) than casual contacts. CONCLUSION: SARS-CoV-2 transmission occurred within the theater, and extended into the community, via a moviegoer who attended the 3rd screening during the viral incubation period after contracting the virus from a family member. This study emphasizes the importance of adequate ventilation in theaters.

2.
J Clin Virol ; 165: 105502, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-37327553

RESUMO

BACKGROUND: This study aimed to investigate ventilation strategies to prevent nosocomial transmission of coronavirus disease 2019 (COVID-19). METHODS: We conducted a retrospective epidemiological investigation of a severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) outbreak in a teaching hospital (February-March 2021). The largest outbreak ward was studied, and measurements were taken to determine the pressure difference and air change per hour (ACH) of the rooms. Airflow dynamics were assessed using an oil droplet generator, indoor air quality sensor, and particle image velocimetry in the index patient's room, corridor, and opposite rooms, by varying the opening and closing of windows and doors. RESULTS: During the outbreak, 283 COVID-19 cases were identified. The SARS-CoV-2 spread occurred sequentially from the index room to the nearest room, especially the opposite. The aerodynamic study demonstrated that droplet-like particles in the index room diffused through the corridor and the opposite room through the opening door. The mean ACH of the rooms was 1.44; the air supply volume was 15.9% larger than the exhaust volume, forming a positive pressure. Closing the door prevented diffusion between adjacent rooms facing each other, and natural ventilation reduced the concentration of particles within the ward and minimised their spread to adjacent rooms. CONCLUSIONS: Spread of droplet-like particles between rooms could be attributed to the pressure difference between the rooms and corridor. To prevent spread of SARS-CoV-2 between rooms, increasing the ACH in the room by maximising ventilation and minimising the positive pressure through supply/exhaust control and closing the room door are essential.


Assuntos
COVID-19 , SARS-CoV-2 , Humanos , COVID-19/epidemiologia , Estudos Retrospectivos , Hospitais de Ensino , Surtos de Doenças
3.
Osong Public Health Res Perspect ; 13(4): 263-272, 2022 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-36097748

RESUMO

OBJECTIVES: It is crucial to establish the characteristics of coronavirus disease 2019 (COVID-19) outbreaks at army training centers to develop preventive measures. Therefore, this study aimed to determine the COVID-19 transmission patterns and risk factors in a sequence of outbreaks at an army training center from June to August 2021. METHODS: This study included 1,324 trainees at an army training center where outbreaks occurred from June to August 2021. The outbreak was qualitatively analyzed according to the period, attack rate, demographic characteristics, vaccination history, and living areas. An aerodynamic experiment was performed to evaluate aerosol transmission in living areas. RESULTS: Three outbreaks occurred at the army training center from June to August 2021. The first, second, and third outbreaks lasted for 32, 17, and 24 days, and the attack rates were 12.8%, 18.1%, and 8.9%, respectively. Confirmed cases were distributed in all age groups. Recruits and the unvaccinated were at higher risk for COVID-19. The aerodynamic experiment verified the possibility of aerosol transmission within the same living area. CONCLUSION: COVID-19 transmission at army training centers should be minimized through quarantine and post-admission testing during the latency period as part of integrated measures that include facility ventilation, vaccination, indoor mask-wearing, and social distancing.

4.
Environ Res ; 212(Pt B): 113318, 2022 09.
Artigo em Inglês | MEDLINE | ID: mdl-35461843

RESUMO

During the last two years, hundreds of millions of people in the world have been infected with SARS-CoV-2 due to recurrent waves and closed spaces. Daycare centers are critical infrastructures that cannot be replaced, even during the COVID-19 period. However, the existing settings in daycare centers may pose risks of inevitable close contact between teachers and children, as well as fomite and airborne transmission during care hours. Therefore, reinforced mitigation strategies have been applied in daycare centers to reduce potential indoor virus transfer in many countries. However, numerous outbreaks of COVID-19 have been reported in daycare centers. Therefore, in this study, researchers focused on the risk and behavior of long-distance virus transmission based on the detected viruses on air purifier filter sampling in a daycare center outbreak in Korea. Various experiments of possible situations were conducted in nursing rooms based on field interviews. The experiments monitored the long-distance transmission behavior of aerosol-sized particles and visualized particle behavior at the daycare center. The results of this study revealed that long-distance virus transmission is possible under the current settings in the daycare center, and flush-out can be an important countermeasure with reinforced ventilation methods to prevent potential airborne spread in the daycare center. The results of air purifiers represented that air purifiers should be properly installed and operated in the daycare center to prevent airborne virus spread by airflow during occupied hours. The findings of this study will contribute to the understanding of airborne virus risk and the development of customized virus measures for daycare centers.


Assuntos
COVID-19 , Creches , Surtos de Doenças , Partículas e Gotas Aerossolizadas , COVID-19/epidemiologia , COVID-19/transmissão , Criança , Surtos de Doenças/prevenção & controle , Humanos , República da Coreia , SARS-CoV-2
5.
Build Environ ; 200: 107951, 2021 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-36570050

RESUMO

The world is having an unprecedented time due to the pandemic. Currently, more than 93 million people have been infected, and over 2 million people have passed away since 2020. SARS-CoV-2 has forced people to change their lifestyles and patterns. Under the pandemic, buildings are no longer safe shelters. The infected transmit infectious viruses to other occupants by direct contact or indirect contact (i.e., indoor airflow). In addition, the airflow from electric heat pump systems can propel indirect contact in indoor spaces. However, the impact of airflow is still not sufficiently identified to develop virus control strategies in buildings. Therefore, this study selected a restaurant in Seoul, Korea, to experiment with airborne virus transmission of direct airflow in winter using virus-similar particles. The results of this study verified the potential exposure of droplets or aerosols to occupants that can be delivered by air current from heating systems in winter. The effect of kitchen hoods was also confirmed as additional ventilation equipment without additional budget investment in restaurants. The recommendations of this study are expected to improve the guidelines for restaurants to ensure occupant's safety during the COVID-19 period.