Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
J Biolumin Chemilumin ; 3(4): 169-74, 1989.
Artigo em Inglês | MEDLINE | ID: mdl-2801204

RESUMO

A simple chemiluminescent immunoassay (CLIA) for urinary albumin has been developed based on the use of a chemiluminescent acridinium ester-labelled human albumin and a commercially available antiserum. It includes two incubation steps and a second polyethylene glycol-assisted antibody separation. The sensitivity of detection is 0.016 mg/l, the assay working range is 0.1-5 mg/l, and the inter-assay CVs are less than or equal to 15%. Using 10- and 50-fold sample dilutions in assay buffer, a wide working range (1-250 mg/l) is obtained covering normal and pathological conditions. Timed overnight urine samples (bed rest conditions) were collected on three consecutive days for each patient. Albumin excretion rate (AER) was 4.7 +/- 2.7 micrograms/min (mean +/- SD), range 1-15.9 micrograms/min in 36 healthy subjects (17 male, 19 female, ages 4-56 years), with day-to-day variations of 28.5 +/- 20% (mean +/- SD), range 3.3-76.1%. The use of an acridinium ester as a chemiluminescent (CL) label overcomes the disadvantages of short shelf-life and health and safety hazards associated with radioisotopes. Results compare favourably with those obtained using a commercially available RIA kit.


Assuntos
Albuminúria/urina , Imunoensaio/métodos , Adolescente , Adulto , Criança , Pré-Escolar , Humanos , Medições Luminescentes , Pessoa de Meia-Idade , Radioimunoensaio
2.
J Biolumin Chemilumin ; 2(3): 121-8, 1988.
Artigo em Inglês | MEDLINE | ID: mdl-3213597

RESUMO

In order to establish optimum conditions for the chemiluminescent (CL) reaction of two acridinium ester labelled proteins (human albumin and rabbit anti-human albumin IgG), we investigated the effects of the following factors known to influence the CL emission: pH, presence of proteins, relative concentrations of components of CL reaction and presence of surfactants. Under optimal conditions of pH and hydrogen peroxide concentration, hexadecyl trimethyl ammonium chloride (CTAC) increased the intensity of the CL reaction of the acridinium ester labelled albumin by 42-fold. Triton X-100, Tween-20, 23 lauryl ether (Brij 35) and sodium dodecyl sulphate (SDS) exerted a much smaller effect. In the case of the acridinium ester labelled antibody, the greatest increase was obtained with Triton X-100 (15-fold) followed by CTAC, Brij 35 and Tween 20 (SDS decreased the emission intensity).


Assuntos
Acridinas , Imunoglobulina G/análise , Albumina Sérica/análise , Tensoativos , Animais , Humanos , Indicadores e Reagentes , Medições Luminescentes , Coelhos , Albumina Sérica/imunologia