Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
Sci Rep ; 13(1): 18457, 2023 Oct 27.
Artigo em Inglês | MEDLINE | ID: mdl-37891377

RESUMO

A new practical imaging technique was presented for metamaterial characterization and investigation by visualizations of the magnetic microwave near-field (H-MWNF) distributions on a metamaterial's surface using the method of thermo-elastic optical indicator microscopy (TEOIM). ITO-based transparent and ceramic-based opaque metamaterial structures were designed for magnetic near-field visualization. Depending on the incident microwave field polarization, the TEOIM system allows the characterization of the metamaterial properties and microwave interaction behavior. The working principle of the periodic structures was investigated through numerical simulations, and the obtained results exhibited strong agreement when compared with experimental observations. Moreover, the visualization of the H-MWNF revealed the potential to characterize and evaluate the absorption and transmission properties effectively.

2.
Sci Rep ; 12(1): 6150, 2022 Apr 12.
Artigo em Inglês | MEDLINE | ID: mdl-35414676

RESUMO

Visualizations of the microwave electric and magnetic near-field distributions of radio-frequency (RF) filters were performed using the technique of thermoelastic optical indicator microscopy (TEOIM). New optical indicators based on periodic dielectric-metal structures were designed for electric field visualization. Depending on the structure orientation, such metasurface-based indicators allow separately visualization of the Ex and Ey components of the in-plane electric field. Numerical simulations were conducted to examine the working principle of the designed indicator structures, and the results were compared to the experimental, showing good agreement. In addition, the 3D visualization of the microwave near-field distribution was built, to show the field intensity and distribution dependencies on the distance from the RF filter.

3.
Sci Rep ; 11(1): 2589, 2021 01 28.
Artigo em Inglês | MEDLINE | ID: mdl-33510224

RESUMO

In this study, a new optical method is presented to determine the concentrations of NaCl and glucose aqueous solutions by using a thermo-elastic optical indicator microscope. By measuring the microwave near-field distribution intensity, concentration changes of NaCl and glucose aqueous solutions were detected in the 0-100 mg/ml range, when exposed to microwave irradiation at 12 GHz frequency. Microwave near-field distribution intensity decreased as the NaCl or glucose concentration increased due to the changes of the absorption properties of aqueous solution. This method provides a novel approach for monitoring NaCl and glucose in biological liquids by using a CCD sensor capable of visualizing NaCl and glucose concentrations without scanning.

4.
Sensors (Basel) ; 19(24)2019 Dec 13.
Artigo em Inglês | MEDLINE | ID: mdl-31847275

RESUMO

We developed a microwave glucose sensor based on the modified first-order Hilbert curve design and measured glucose concentration in aqueous solutions by using a real-time microwave near-field electromagnetic interaction technique. We observed S21 transmission parameters of the sensor at resonant frequencies depend on the glucose concentration. We could determine the glucose concentration in the 0-250 mg/dL concentration range at an operating frequency of near 6 GHz. The measured minimum detectable signal was 0.0156 dB/(mg/dL) and the measured minimum detectable concentration was 1.92 mg/dL. The simulation result for the minimum detectable signal and the minimum detectable concentration was 0.0182 dB/(mg/dL) and 1.65 mg/dL, respectively. The temperature instability of the sensor for human glycemia in situ measurement range (27-34 °C for fingers and 36-40 °C for body temperature ranges) can be improved by the integration of the temperature sensor in the microwave stripline platform and the obtained data can be corrected during signal processing. The microwave signal-temperature dependence is almost linear with the same slope for a glucose concentration range of 50-150 mg/dL. The temperature correlation coefficient is 0.05 dB/°C and 0.15 dB/°C in 27-34 °C and 36-40 °C temperature range, respectively. The presented system has a cheap, easy fabrication process and has great potential for non-invasive glucose monitoring.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA